technical features

Download TECHNICAL FEATURES

If you can't read please download the document

Upload: xarles

Post on 10-Jan-2016

32 views

Category:

Documents


0 download

DESCRIPTION

TECHNICAL FEATURES. Course Layout. DUOX Technical Department. System Summary. Why DUOX?. Introduction. Technical Manuals. How to make a material list. Catalogue. Audio. Riser Splitter Switcher. Programmer tool. The Riser. Riser Basics. Auto Switch-ON. 1 to n panels. - PowerPoint PPT Presentation

TRANSCRIPT

  • TECHNICAL FEATURES

  • The Technical BookAt a GlanceHow to SellTechnical AspectsDUOXTechnical Department Course Layout Catalogue

  • The target of the DUOX development is to implement a system on two non polarized wires with digital audio that has to be in a similar cost level like VDS. DUOX will offer the functionalities of the existing systems (4+N, VDS, Bus2, MDS).The DUOX is the first full digital system in the market that requires two non-polarized wires for: power, audio, video & data transmission

    In this new technology, the best characteristics of the previous systems converge:

    MDS: High performance and great capacity.VDS: Competitive price. Wiring flexibility.BUS2: 2 non polarized wires.

    And the result is DUOX, a GLOBAL SYSTEM FOR ALL THE MARKETS.

    Its main objective is to substitute all the previous systems in a 3 years period.DUOXTechnical Department Introduction

  • FeaturesInstallation Complexity4+NDirect & CityCall becomes DigitalMany ApartmentsMany Panels (up to 7)Thousands of apartmentsThousands of panelsDigitalMDSDuox: System of systems Historically, manufacturers have sold installation simplicity. MDS put apart the 4+N call wires, adding advanced features such as access control, electronic directory and automation. Installation complexity was kept similar to its antecesor. VDS has kept a capacity big enough to satisfy the most common installations, achieving at the same time a dramatic wiring reduction. BUS2 reduced installation to its minimum expression, offering added-value functions such as bus-command relay activation, diagnose tooling and installation simplicity.

    DUOX keeps the simplicity of Bus2 (2 non-polarized wires), introducing the advantages of the digital audio (Improvement of audio quality, less noises and feedback,), and extending the capabilities of the system from villas kits to big condominiums (like MDS).VDSFew WiresMany apartmentsMinimum WiringDigital audioThousands of apartmentsMicroprocessor TerminalsFrequencyMultiplexingDUOXBUS2Digital AudioMinimum WiringMany apartmentsDUOXTechnical Department Why DUOX?

  • Up to 10 panels and 10 guard units at the General entrance and at each block. Up to 10 panels at each Sub-block. Up to 2 simultaneous conversation channels in the same bus. FeaturesFrom villas kit to big condominiumsDUOXTechnical Department System Summary (1)

    - Up to 3 terminals in the same apartment. Same programming as in VDS and Bus 2. 3 LEVELS:- General entrance. Block entrances. Up to 99 blocks. Sub-Block entrances. Up to 99 Sub-Blocks per block.

    ADDRESSING- Up to 999.999 addresses (apartments). - Telephone address format: 6 digits, from 000.001 to 999.999.

  • DUOXTechnical Department System Summary (2)Max. 4 risers at busTelephone riserTelephone risersTelephone riserMax. 5 apartment splits at each riser point

  • Power for audio BUILDING InstallationsDUOXTechnical Department System Summary (3)(i) For 12 Vdc door lock max. 250 mA supplied from amplifier.(ii) Each additional PSU+filter allow to expand the system in distance and terminals according to the table.(iii) Longer distances than 300m can be reached via regenerators.

  • Power for audio 1 WAY KIT InstallationsDUOXTechnical Department System Summary (4)(i) For 12 Vdc door lock max. 250 mA supplied from amplifier.

  • WIRES SUPPORTED

    PARALLEL (RED & BLACK). min 0,14mm2.UTP.UTP CAT-5.REFURBISHMENT:5 WIRES CABLEDOOR BELL 2 WIRESOLD 4+N CABLE

    Remarks:With each type of cable, distance will depend on the load of terminals, topology, number of PSUs, and active telephones at the same time (In the same or different apartments in case of 2 communications at the same time).It is recommended to use a parallel cable with cross section thicker than 0,25mm2, especially due to the drop voltage in the long distances.It is possible to use other type of cables as alternative, such as Cat-5 or twisted pair, taking into consideration that the maximum distance will be reduced.

    DUOXTechnical Department System Summary (5)Parallel CableTwisted PairRefurbishment9/10me (3 rolled pairs)UTP (CAT-5)

  • Block 00PSU3243General Entrance (GE)GE , Panel 0GE, Panel 2GE, Panel 3DUOXTechnical Department General Entrance / Block / Sub-BlockBlock 01Block 99Sub-Block 04GE , Panel 1Sub-Block 00System Summary (6)

  • DUOXFull digital system on 2 non polarised wires 222BUSdriven RelayDuox: The evolution. BUS22 non polarised wires 222Panels SwitcherSignal DistributorBUSdriven RelayDUOXTechnical Department 3 + Cx3 + CoaxVDS3 + Coax3SConnectionVideo DistributorPanels SwitcherRelay with additional wiringSystem Summary (7)Line termination at last split to avoid reflections

  • Systems comparison DUOXTechnical Department System Summary (8)

    VDSBUS 2DUOXAddresses199199999.999 Panels2210 at General Entrance / 10 per Block and Sub-block Guard units1None, only via MDS10 at General Entrance / 10 per Block Distance200 m200 m 300 m per branch without regenerator (Expandable)PrivacyYesYesYesPower18 Vdc for all signals24 Vdc for all signals + Filter Ref.324318 Vdc for all signals + Filter Ref.3243Type of audioAnalogAnalogDigitalInmunity against noises and feedbackLow MediumHighWiring3 wires + Coaxial Wiring flexibility (Several type of cables)2 non polarized wires Restricted cables applicable (Parallel, twisted pair) to keep impedance for proper signal transmission2 non polarized wires Wiring flexibility (Several type of cables)PriceCompetitiveHighCompetitiveTransmission mediaSignals delivered in different physical media ("L", "+", "-", "M", "V")All signals : Supply, commands, audio and video delivered in the same physical media, 2 wiresAll signals : Supply and data (Commands, audio, video) delivered in the same physical media, 2 wiresEnd of line termination75 Ohm resistor between "M", "V" for video impedance. 10 KOhm resistor between "L", "+" for pull-up.Line termination to avoid reflections, set via jumpers located at riser devices.Line termination to avoid reflections, set via device located at last riser split.Relay, Additional featuresRef.2013 via additional wiringBus2 relay without additional wiring managed via commands ("F1", "F2", opening,)DUOX relay without additional wiring managed via commands ("F1", "F2", opening,)Converstation channels112 (Expandable via Switchers)Troubleshooting and programming toolNoYesYes

  • Main Duox characteristicsThe DUOX electronics allows that supply, data and audio (and video when available) are delivered in the same bus with 2 non polarized wires.

    Supplied with 18 Vdc for all signals via a coupling module (Minimum functional voltage 15 Vdc at terminal and amplifier).

    Full Digital system (Audio and commands)

    Two simultaneous conversation channels on the same 2 wires thanks to the multiplexing.

    Privacy in communications.

    DUOXTechnical Department System Summary (9)

  • DUOX Advantages:

    Additionally to the advantages of the digital audio, DUOX system offers by itself other improvements in comparison with the existing systems:

    A more stable system regarding to signal transmission (to avoid reflections) and to achieve further distances (in the same circumstances: Type of cable, topology,). This fact allows that devices that were required in Bus2 (as signal distributors or end of line jumpers at terminals), are no longer necessary in DUOX, as the signal transmission is more robust with respect to reflections and interferences. Only a Line termination will be used at last riser split to avoid reflections.

    As well the recognition of data is better in a digital system than in other systems like VDS where pull-up resistors were necessary due to the signal deformation because of the capacitor effect of the conductors.

    Two communication channels available at the same time.

    It collects the best features from other systems: High performance, wiring flexibility, competitive price and installation simplicity.

    DUOXTechnical Department System Summary (10)End of line termination used in DUOX: To avoid reflections.Connected at last riser bus split.

    End of Line Termination

  • Basics18 VDCPSUPower supply Adaptor 32432218 VDCPSUPower supply adaptor324322 simultaneous conversation channelsUp to 300 m10 panels and 10 guard units per sub-block

    18 VDCPSUPower supply Adaptor 32432KitSimple BuildingMultiple accesses18 VDCPSU3243DUOXTechnical Department The riser (1)End of Line Termination

  • Basics: Kits18 VDCPSUPower supply Adaptor 32432With regards to the line termination in Kits, in case that there is only one telephone, no line termination is necessary (as reflections cannot affect other telephones). But when additional telephones are installed as well the line termintation has to be foreseen.

    Kit with one telephoneDUOXTechnical Department The riser (2)Power supply Adaptor 32432Kit with addtional telephonesLine Termination18 VDCPSUCascade

  • Basics with general entrance18 VDC324318 VDC32432General entrance to villasGeneral entrance and panels at each floor18 VDC324318 VDC32432DUOXTechnical Department The riser (3)2 simultaneous conversation channelsUp to 300 m10 panels and 10 guard units per sub-block

    End of Line Termination

  • Risers Distributor Ref.3258 FUNCTIONS:

    1._ REGENERATOR:Each output of the distributor delivers a regenerated signal to develop bigger installations, allowing to increase the NUMBER OF RISERS: Max.16 outputs in total.

    2._ ISOLATOR:The 2 outputs of the distribuor remain electrically isolated. A short-circuit in one of them will not affect the rest.

    DUOXTechnical Department The riser (4)18 VDC3243End of Line TerminationRisers distributor

  • Risers Distributor Ref.3258 SUPPLY MODES:DUOXTechnical Department The riser (5)1._ ONLY RISERS 2._ RISERS + PANELS: Additionally to the risers, the panel is as well supplied.Notes:PSU 18Vdc connected directly without filter Ref.3243.1 x PSU can supply Max.24 Telephones per riser and 1 panel. For more loads, additional PSU to be used (Max.6xPSUs per riser). Up to 4 distributors can be concatenated in parallel and on each output a new splitter can be inserted (Maximum 2 levels: 16 outputs in total).

  • Risers Distributor Ref.3258 CONNECTIONS AND SIGNALIZATION:DUOXTechnical Department The riser (6)

  • Risers Distributor Ref.3258 TECHNICAL FEATURES:DUOXTechnical Department The riser (7)

  • Switcher (Block isolator)The switcher converts each branch in a different bus, allowing two additional conversation channels after the switcher. General entrance18 VDC32432DUOXTechnical Department The riser (8)324318 VDCEach bus has 2 conversation channels available

  • Power Supply unit + Power FilterDUOXTechnical Department The riser (9)220Vac18VdcThe output capacitor behaves like a shortcircuit for DUOX signalsDUOXRiserCouples DC current (power) to the DUOX BUSDUOX Power Supply Filter Ref.3243Prevents DUOX signals to traverseNETNETPower is coupled by mean of inductances.It is used the same filter module Ref.3243 as in Bus2.Not any power supply is valid, as the used power supply has not to introduce common noise in the DUOX bus. Fermax references:Ref.4812, 18 Vdc, 1,5 A. Version 2.0.Ref.4830, 18 Vdc, 3,5 A. Version 3.0.The DUOX signal will not leave the bus due to the high impedance presented by the filter.

  • Why not any power supply unit is valid?DUOXTechnical Department The riser (10)As explained before, DUOX system requires a controlled power supply unit, that means a power supply units that does not generate high frequency noises that may be induced in the system, bloking the supply and the proper working of the installation. The high frequency noises enter in resonance with the filter, avoiding the correct working of the system..Our power supply units Ref.4812 v.2.0 (18 Vdc, 1,5 A) and Ref.4830 v.3.0 (18 Vdc, 3,5 A) are controlled units that do not present high frequency noise.

    Standard non controlled power supply unit that presents high frequency noiseControlled power supply units Ref.4812 v.2.0 and Ref.4830 v.3.0 that show only the standard 50 Hz noise but no high frequency noise

  • DUOX Programmer Ref.3254It will be used to make easier the configuration and to identify problems in an installation. The format of the tool will be like the Loft access control readers (Simple display and keypad).Same programmer tool for all DUOX devices (current and futures).The information is managed by the programmed device.

    Operation modes:1._ Configurator ModeIt allows programming of:Telephones (Address, melody, door matic).Panel amplifier (Number, mode, opening times, guard units modes).

    2._ Analyzer ModeIt allows different functions:Devices detection (Telephones, amplifiers, guard units).Analysis of frames.Call to apartments.Channels in use detection.Meassuring of signals (Voltage,).Status of telephone (Existance, hook, occupied, do no disturt, doormatic,).DUOXTechnical Department The riser (11)

  • ModelsKIT 1-2 WAY: Internal pushbuttons.Inverse programming to allow no limitation of panels according to telephone address (Useful for villas).

    DIRECT :999.999 addresses.One Access code for door opening.Keypad used for system configuration.

    PUSHBUTTONS: 99 addresses.Continuous profile with call extension pack.Skyline with pushbuttons modules.One to one module adaptable.DIGITAL :Text and graphical display.DUOX programming software.Access codes for door opening.

    DUOXTechnical Department Panel (1)Panels with combination of keypad + pushbuttons (Dentist,).

  • DUOX Amplifier: ConnectionsDUOXTechnical Department Panel (2)One To One connection for informationmoduleConnection of call extension packor keypad, or pushbutton modulesTamper connection against manipulation of panel: A sensor will control if someone tries to remove the panel screws sending an event to the guard unitPGR Button for Master and mapping configurationVoice synthesizer:29 different languagesAudio volume potentiometers:UplinksDownlinksVoice synthesizerStatus led:Off: Night mode for guard unit2 blinks per second: Day or mixed mode for guard unit1 blink per second: Inverse and Sequential programming

    SymbolDescriptionP1Connection of right pushbutton to call extension packB,BDUOX Bus : Audio-video, data and supplyC, NO, NCDoor opener relay contact. 2A @12Vdc+12Output 12Vdc to supply access control or DC door opener. Max.500mABSExit button-Negative of amplifier. (For Bs, S,)SInput for door sensor. Connected to - means door closed.+18,GNDInput of supply 18Vdc. For small installations without filter.P2Connection of left pushbutton to call extension pack

  • DUOX Amplifier: Supplied via filter module through B, BDUOXTechnical Department Panel (3)220 Vac18 Vdc4812

  • DUOX Amplifier: Supplied without filter module, directly through +, GNDDUOXTechnical Department Panel (4)220 Vac18 VdcNote that in case of small installations (1 panel and up to 24 telephones), it is possible not to use the filter module Ref.3243, as the amplifier has as well a small internal filter.Supplying directly the amplfier through the + and GND terminals with the 18 Vdc power supply unit Ref.4812 v.2.0 / 4830 v.3.0.

  • DUOX Technical Department

    220 Vac18 Vdc4812Amplifier 1Amplifier 24812 PSU3243 FilterDUOX: 2 x amplifier / 1 x PSU / 1 x FilterPanel (5)

  • DUOX Technical Department

    DUOX: 2 x amplifier / 2 x PSU / 2 x Filter220 Vac18 Vdc4812Amplifier 1Amplifier 24812 PSU3243 Filter220 Vac18 Vdc48124812 PSU3243 FilterPanel (6)

  • DUOX Technical Department

    220 Vac18 Vdc4812Amplifier 1Amplifier 24812 PSUDUOX: 2 x amplifier / 1 x PSU (no filter)Panel (7)

  • DUOX Technical Department

    220 Vac18 Vdc4812Amplifier 1Amplifier 24812 PSUDUOX: 2 x amplifier / 2 x PSU (no filters)220 Vac18 Vdc4812CONNECTION AMP1 AMP2Same polarity must be applied when linking both B,B terminals to each other between the amplifier modules. 4812 PSUPanel (8)

  • Panel configuration (1)DUOXTechnical Department Panel (9)At each panel we have to configure:

    1._ The mode:1.1_ As General Entrance.1.2_ As Block / If this is the case, additionally the number of the Block.1.3_ As Sublock / If this is the case, additionally the number of the Sub- Block.

    2._ The number of the panel.

    MODE Number of Block or Sub-blockNumber of PanelPanel can call to RANGE of telephones:GENERA ENTRANCE (GE)NoneFrom 0 to 900 00 01 to 99 99 99BLOCK (B)From 00 to 99From 0 to 900 01 to 99 99SUB-BLOCK (S) From 00 to 99From 0 to 901 to 99

  • Panel configuration (2)DUOXTechnical Department Panel (10)Power supply Adaptor 3243

  • Panel configuration (3)DUOXTechnical Department Panel (11)Example 2Panel configurationMode: General Entrance (Dial at panel: telephone TT TT TT. For example 00 00 03)Panel Number: 0Telephone address: 01 00 03 18 VDC32432324318 VDCPanel configurationMode: Block / Block Number: 00 (Dial at panel: teleph. TT TT. For example 00 03)Panel Number: 0Telephone address: 00 00 03Panel configurationMode: Block / Block Number: 01 (Dial at panel: teleph. TT TT. For example 00 03)Panel Number: 0

  • Block 00PSU3243General Entrance (GE)GE , Panel 0GE, Panel 2GE, Panel 3DUOXTechnical Department Panel configuration (4)Panel (12)Panel configurationMode: General Entrance (Dial at panel: telephone BB SS TT. For example 01 04 07)Panel Number: 1Telephone address: 01 04 07 Block 01Block 02Sub-Block 04Panel Number: 0Panel configurationMode: Block, Number 01 Panel Number: 0GE , Panel 1Panel configurationMode: Block, Number 02 Panel Number: 0Panel configurationMode: Block, Number 00 Panel Number: 0Example 3

  • DUOXTechnical Department Panel (13)The parameters of the outdoor panel can be programmed from keypad, by entering the configuration mode: A + 4444 (Confirmation tone beep-beep is heard) + Command number (See table) + Value.Dial A to quit configuration mode.Panel configuration from Direct Keypad

    Command NumberParameterPossible values [By default]Comment01Door Opening time01-99. Opening from telephone or access control[03]02Door Opening time from Exit button00-99.Door Relay activation from exit button (Terminal "BS")[06]03Mode of panel 0-Sub-BlockMode of panel configuration[1]-Block 2- General Entrance04Block Number00..99The panel belongs to this block number[00]05Sub-Block Number00..99The panel belongs to this Sub-block number[00]06Panel Number0..9Panel Number[0]07Sensor Door Time00..99Max.time that door can remain released since opening[00] (not acitve)08Openinig Code0000..9999Opening code from keypad[AAAA](not active)09Programming access code0000..9999Programming access code[4444]10Master panel mode[0]- NoTo program telephones1- Si11Guard unit mode0Resets to night mode when this option is selected12Volume of confirmation tone at panel0..9Adjustment of the confirmation tone at panel[5]13Parameters Reset [0] No reset1 ResetIt recovers the default values when this option is selected

  • DUOXTechnical Department Panel (14)How to program the Mapping Call Code: Inverse programmingMapping is an advanced programming function available in panels with pushbuttons. It allows the modification of the call code assigned based on their position on the call extension module or button module. BeepDUOX address stored at terminal memoryProgramming tonePress the PGR button, 10Led blinks

    STEPACTIONPICTURERESULT1Firstly program the telephone from the Master panel. (See slide Telephone programming)2Select the inverse programming' mode on the DUOX by keeping pressed PGR button during 10 sec, until 1 beep is heard and the led blinks once per second.3Assign the new addresses to each button:3.1Press the programming button at telephone

  • DUOXTechnical Department Panel (15)How to program the Mapping Call Code: Inverse programming (Continuation)Remark: In order to program the rest of monitors, repeat steps from 3.1 to 3.2.Remember that the default call order is from bottom to top and from right to left.Mapping code stored at amplifierPanel at stand-by statusPress the PGR button

    STEPACTIONPICTURERESULT3.2Press the call button associated with this telephone (apartment) on the entry panel.

    The address previously programmed on that telephone will be assigned to the button (it will be stored onthe amplifier).4Exit Programming:Press the PGR button again.Anyway the amplifier will automatically exit the programming mode after 5 minutes of inactivity.

  • DUOXTechnical Department Panel (16)How to program the Mapping Call Code: Sequential programmingMapping code stored at amplifierPanel at stand-by statusDUOX address stored at terminal memoryPress the PGR buttonBeepBeepLed blinksPress the PGR button

    STEPACTIONPICTURERESULT1Firstly program the telephone from the Master panel. (See slide, Telephone programming)

    2Select the sequential programming mode by keeping pressed PGR button. After 10 seconds a first beep is heard, keep pressing during still 5 sec. until 2 beeps are heard and the led blinks once per second.3Assign the new addresses to each button:Press the call buttons in whatever order you wish, to assign the codes on the entry panel, starting with 1, and running sequentially to the last required number.4Exit Programming:Press the PGR button again.Anyway the amplifier will automatically exit the programming mode after 1 minute of inactivity.

  • DUOXTechnical Department Telephone (1)

    CITYMAX BasicDUOX TelephoneLOFT BasicDUOX TelephoneLOFT Basic Plus DUOX TelephoneLOFT ExtraDUOX TelephoneRef. 3425Ref. 3420Ref. 3421Ref. 3422Terminals: B , BTerminals: B , BB , B , T , A , -B , B , T , A , - , F1, F2Melody selectionMelody selectionMelody selectionDoor bellCall ExtenderLight&Buzzer activatorMelody selectionDoor bellCall ExtenderLight&Buzzer activatorCall volume regulatorMute modeF1 and F2 buttonsStand-by Cons.: 16mAStand-by Cons.: 16mAStand-by Cons.

  • Telephone ProgrammingDUOXTechnical Department Telephone (2)Note that the programming of the telephones will be performed from the Master panel.The procedure to set a panel as Master is following:Press 3 times consecutively the PGR button at the rear side of the amplifier, a confirmation tone (beep-beep) will be heard.

    To remove the Master mode, just press again 3 times consecutively the PGR button and a Bop tone will confirm it.

    In an installation only one panel at the same time can be Master.In case there is already a Master panel in the system, when another panel is set as Master, the previous one will be automatically removed from Master mode.

    BeepBeepPress 3 times consecutively the PGR buttonStep 1Step 2To set the panel as MasterBopPress 3 times consecutively the PGR buttonStep 1Step 2To remove the panel of Master Mode

  • Loft Telephone Programming

    Press the programming button and released it. Confirmation tone is heard.

    Press the corresponding pushbutton at the Master panel (or dial the apartment number in the keypad).

    The confirmation tone is heard again.

    The telephone will store the 6 digits of the panel call as DUOX address.DUOXTechnical Department Telephone (3)

  • DUOXTechnical Department Telephone (4)

    Melody Selection by installer at Loft Basic

    The telephone allows to select a different melody to distinguish when it is called from the outdoor panel or from the guard unit.The selection is done by the installer.

    MELODIES available:Bitone Fermax.Monotone Fermax.Monophonical Ding-Dong-Dang.Following steps to select the melody for panel call (All panels same melody):At the telephone, press simultaneously the programming and the door opening button: The current telephone melody for a panel call is heard.Pressing sequentially the programming button, the rest of melodies are heard.After 10 sec.without presssing any button, the last melody performed will be stored.The exit of configuration is confirmed by a beep.Following steps to select the melody for guard unit call:At telephone press simultaneously the programming and the door opening button during 5 seconds: The current telephone melody for a guard unit call is heard.Pressing sequentially the programming button, the rest of melodies are heard.After 10 sec.without presssing any button, the last melody performed will be stored.The exit of configuration is confirmed by a beep.5 Sec.

  • Pick up the handset and after few seconds automatic communication is established with panel.DUOXTechnical Department Telephone (5)

    Just after picking up the handset, any telephone programmed with a valid address TT TT TT will establish communication with the panel number 0 of its block.Under the condition that there is a free channel in that block and the panel 0 is available.From this moment, the behaviour will be the same as in an accepted call (Door opening available, 90 sec.of max.conversation time,)If this feature is not wished, just change the number of the panel to a number different from 0.

    If after picking up the telephone handset, the panel 0 is in communication with other telephone or there is another telephone of the same apartment in communication, a busy tone will be heard at the telephone.

    Autoswitch-on from the telephone to the panel number 0 of its Block

    PANEL 0

  • Audio InstallationsChoose a Panel. City / Skyline / Marine Buttons / Direct / Digital.Digital with text or graphical display Block EntranceRisersApartmentsAdd to the list of materials the necessary common items according to the toplogy and requirements (Supply and filters, Risers distributor, terminations,).First step! Sketch the installation!Up to 3 telephones per apartment.DUOXTechnical Department How to make a material list (1)

  • Example 1 General Entrance City Digital Audio panel to 4 Interior Blocks with 1 Audio City direct panel to 60 Citymax basic telephones on each. General Entrance: 1 x 7384 DUOX City Digital Audio Panel S7 1 x 8857 S7 Flush Mounted Box 1 x 3243 DUOX Power Supply adapter module 1 x 4812 18 Vdc Power Supply Each Interior Block x 4Accesses 1 x 7361 DUOX Direct City Audio Panel S5 1 x 7309 CityLine Directory Panel S5 2 x 8855 S5 Flush Mounted Box 1 x 8829 Set of Separators 2 x 3243 DUOX Power Supply adapter module 2 x 4812 18 Vdc Power Supply Backbone 60 x 3425 DUOX Citymax Basic Telephone1 x 3255 DUOX Line termination How to make a material list (2)DUOXTechnical Department

  • Example 2 General Entrance 3 x Audio City direct panels to 5 Interior Blocks with Skyline Audio 40 buttons panel to 40 Loft extra telephones on each. General Entrance: 3 x 7361 DUOX Direct City Audio Panel S5 3 x 7309 CityLine Directory Panel S5 6 x 8855 S5 Flush Mounted Box 3 x 8829 Set of Separators 1 x 3243 DUOX Power Supply adapter module 1 x 4812 18 Vdc Power Supply

    3 x 3258 DUOX Risers distributor3 x 4812 18 Vdc Power Supply Each Interior Block: x 5Accesses 1 x 7390 DUOX Skyline audio amplifier 5 x 7371 Skyline DUOX/VDS 8 buttons module 2 x 7336 Skyline Frame 6V (S7)2 x 8857 S7 Flush Mounted Box 1 x 8829 Set of Separators 1 x 3243 DUOX Power Supply adapter module 1 x 4812 18 Vdc Power Supply Backbone 40 x 3422 DUOX Loft Extra Telephone1 x 3255 DUOX Line termination How to make a material list (3)DUOXTechnical Department

  • DUOXTechnical Department Questions?

    *********************************************