technical design guide for waterproofing
DESCRIPTION
WaterproofingTRANSCRIPT
Technical design guide
for WATERPROOFING
1
6
7
34
5
4
1
2 3
7
8
8
ADHESIVES • SEALANTS • CHEMICAL PRODUCTS FOR BUILDING
1
Technical design guidefor WATERPROOFING
INTRODUCTION
MAPEI, world leader in the production of adhesives and chemical products for the building industry, has always
invested considerable resources into research and development with the aim of constantly developing cutting-edge
solutions to be integrated into executive projects.
And this is what convinced MAPEI to make their technological know-how available in a simple, clear and readily
available format to guide their customers through the maze of their product ranges, and illustrate their characteristics,
functions and application methods.
With this aim in mind, this document is intended to be a handy guide and support for designers and clients alike, to
reduce problems caused by either incorrect or inaccurate technical specifications during the design phase and by
errors during application or a lack of attention to detail. In fact, with their eye for detail, MAPEI clearly demonstrates
their know-how by offering simple, sound technical solutions.
To make it easier to consult this manual, there are two images at the start of the document that show the various
areas of intervention and an index of the details. The manual is then sub-divided into two sections. The first,
indicated with a red bookmark, discusses construction details for waterproofing new buildings, while the second
section, indicated with a yellow bookmark, covers repair work. At the end of the manual, there is also an overview
of all the products from the range which are used.
For further information about each of the products mentioned in the technical specifications, consult the relative
Technical Data Sheet on the MAPEI website www.mapei.it.
NOTE: The products presented below are those used for waterproofing new and existing constructions. For products not covered by this waterproofing
range manual, please refer to the general products catalogue. The Company’s Technical Services Department is at your complete disposal for
further information on the characteristics and application techniques applicable to our products, and for suggestions on how to solve a wide range
of technical problems, including the design of construction details.
2
Technical design guidefor WATERPROOFING
List of Drawings
NEW CONSTRUCTIONSBELOW GROUND LEVEL
SEALING OF WELL PUMPING ATE N SQ 001 page 10
PILES WATERPROOFING ATE N SQ 002 page 11
PIPE PENETRATION DETAILING ATE N SQ 003 page 12
WATERPROOFING CONCRETE SLAB (CONNECTED WITH SOIL RETAINING WALLS) AND WALLS ATE N SQ 004 page 13
WATERPROOFING CONCRETE SLAB AD WALLS ATE N SQ 005 page 14
ELEVATOR SHAFT ATE N SQ 006 page 15
FOUNDATION PILES - SOLUTION 1 ATE N SQ 007 page 16
FOUNDATION PILES - SOLUTION 2 ATE N SQ 008 page 17
MAPEPROOF POST-CASTING ATE N SQ 009 page 18
CONSTRUCTION JOINT ATE N SQ 010 page 19
MAPEPROOF ON SLAB AND MAPELASTIC FOUNDATION ON WALL ATE N SQ 011 page 20
SLAB CAST WITH FORMWORKS ATE N SQ 012 page 21
SEALING OF PENETRATION PIPE ATE N SQ 013 page 22
PILES WATERPROOFING: TOP BEAM DETAIL ATE N SQ 014 page 23
CONNECTION BETWEEN IDROSTOP B25 AND IDROSTOP PVC BI ATE N SQ 015 page 24
STRUCTURAL JOINT WATERPROOFED WITH IDROSTOP PVC BE ATE N SQ 016 page 25
STRUCTURAL JOINT WATERPROOFED WITH IDROSTOP PVC BI ATE N SQ 017 page 26
CONSTRUCTION JOINT ATE N SQ 018 page 27
SMALL COURTYARD ATE N SQ 019 page 28
CAR PARKS RAMP ATE N SQ 020 page 29
WATERPROOFED INTERMEDIATE FLOOR - TOPDOWN CONSTRUCTION ATE N SQ 021 page 30
WELLPOINT SEALING ATE N SQ 022 page 31
MAPEPROOF ON SLAB AND PLASTIMUL ON WALL ATE N SQ 023 page 32
MAPEPROOF - INVERTED BEAM ATE N SQ 024 page 33
WATERPROOFING ON COFFERDAMS - BY USING OSB PANELS ATE N SQ 025 page 34
3
NE
W C
ON
STR
UC
TIO
NS
ATE N FQ 019
ATE N SQ 001
ATE N SQ 002
ATE N SQ 004
ATE N SQ 025
ATE N SQ 015
ATE N SQ 016
ATE N SQ 017
ATE N SQ 018
ATE N SQ 010
ATE N SQ 012
ATE N SQ 024
ATE N SQ 009
ATE N SQ 011
ATE N SQ 023
ATE N SQ 003
4
Technical design guidefor WATERPROOFING
List of Drawings
NEW CONSTRUCTIONSABOVE GROUND LEVEL
FRONT EDGE OF A BALCONY - MARBLE SILL ATE N FQ 001 page 35
FRONT EDGE OF A BALCONY - CERAMIC SILL ATE N FQ 002 page 36
FRONT EDGE OF A BALCONY - PARAPET ON FLOOR SLAB ATE N FQ 003 page 37
FRONT EDGE OF A BALCONY - PARAPET ATE N FQ 004 page 38
BALCONY SILL - SILL FRAME ATE N FQ 005 page 39
FLOOR - WALL FILLET ATE N FQ 006 page 40
FLOOR - BITUMINOUS FILLET ATE N FQ 007 page 41
FLOORING - INSULATING PANEL ATE N FQ 008 page 42
SEALING STRUCTURAL JOINT - MAPEBAND TPE ATE N FQ 009 page 43
SEALING A CHECK JOINT - MAPEBAND ATE N FQ 010 page 44
STRUCTURAL JOINT FLOORING - WALL ATE N FQ 011 page 45
DRAIN LATERAL ATE N FQ 012 page 46
DRAIN VERTICAL ATE N FQ 013 page 47
DRAIN FRONT ATE N FQ 014 page 48
FRONT EDGE OF A BALCONY - THERMAL INSULATION ATE N FQ 015 page 49
5
NE
W C
ON
STR
UC
TIO
NS
ATE N FQ 007
ATE N FQ 010
ATE N FQ 011
ATE N FQ 012ATE N FQ 005
ATE N FQ 013
ATE N FQ 001
ATE N FQ 002
ATE N FQ 003
ATE N FQ 004
ATE N FQ 006
ATE N FQ 008
ATE N FQ 010
ATE N FQ 014
6
Technical design guidefor WATERPROOFING
INTERNAL LINING - MAPEPROOF AND MAPELASTIC FOUNDATION ATE R SQ 001 page 50
INTERNAL LINING ON A FOUNDATION SLAB AND WALL - MAPEPROOF ATE R SQ 002 page 51
SEALING PENETRATIONS WITHOUT WATER IN PRESSURE ATE R SQ 003 page 52
STRUCTURAL JOINT - WALL AND SLAB ATE R SQ 004 page 53
INTERNAL LINING - MAPEPROOF AND MAPELASTIC FOUNDATION ATE R SQ 005 page 54
List of Drawings
REPAIRINGBELOW GROUND LEVEL
7
RE
PA
IRIN
G
ATE R SQ 001
ATE R SQ 004
ATE R SQ 002
ATE R SQ 003
8
Technical design guidefor WATERPROOFING
List of Drawings
REPAIRINGABOVE GROUND LEVEL
FRONT EDGE OF A BALCONY WITH SILL -WATERPROOFING ON EXISTING FLOORING ATE R FQ 001 page 55
JUNCTION INTERNAL SILL - FLOORINGWATERPROOFING ON EXISTING FLOORING ATE R FQ 002 page 56
FRONT EDGE OF A BALCONY - PARAPETWATERPROOFING ON EXISTING FLOORING ATE R FQ 003 page 57
JUNCTION FLOORING - WALLWATERPROOFING ON EXISTING FLOORING ATE R FQ 004 page 58
CHECK JOINT -WATERPROOFING ON EXISTING FLOORING ATE R FQ 005 page 59
DRAIN VERTICALWATERPROOFING ON EXISTING FLOORING ATE R FQ 006 page 60
9
RE
PA
IRIN
G
ATE R FQ 001
ATE R FQ 002
ATE R FQ 004
ATE R FQ 006
ATE R FQ 005
ATE R FQ 003
10
Technical design guidefor WATERPROOFING
NEW CONSTRUCTIONSBELOW GROUND LEVEL
11
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
12
Technical design guidefor WATERPROOFING
NEW CONSTRUCTIONSBELOW GROUND LEVEL
13
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
14
Technical design guidefor WATERPROOFING
NEW CONSTRUCTIONSBELOW GROUND LEVEL
15
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
16
Technical design guidefor WATERPROOFING
1
5
6
8
3
7
5
44
2
3
Foundation piles -solution 1
Code:ATE N SQ 007
NEW CONSTRUCTIONSBELOW GROUND LEVEL
17
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
18
Technical design guidefor WATERPROOFING
MAPEPROOF post-casting Code:ATE N SQ 009
1
23
4
5
6
7
9
8
3
10
NEW CONSTRUCTIONSBELOW GROUND LEVEL
19
NE
W C
ON
STR
UC
TIO
NS
Code:ATE N SQ 010
Construction joint
3
4
5
1
≥ 5cm
≥ 8cm
2
7
6
3
4
1
≥ 5cm
≥ 8cm
2
7
8
5
NEW CONSTRUCTIONSBELOW GROUND LEVEL
20
Technical design guidefor WATERPROOFING
MAPEPROOF on slab andMAP. FOUNDATION on wall
Code:ATE N SQ 011
1
23
4
5
6
7
9
811
10
3
NEW CONSTRUCTIONSBELOW GROUND LEVEL
21
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
22
Technical design guidefor WATERPROOFING
BELOW GROUND LEVELNEW CONSTRUCTIONS
23
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
24
Technical design guidefor WATERPROOFING
Connection between IDROSTOP B25and IDROSTOP PVC BI
Code:ATE N SQ 015
10 cm
7
6
5
7
1
2
4
3
6
NEW CONSTRUCTIONSBELOW GROUND LEVEL
25
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
26
Technical design guidefor WATERPROOFING
NEW CONSTRUCTIONSBELOW GROUND LEVEL
27
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
28
Technical design guidefor WATERPROOFING
NEW CONSTRUCTIONSBELOW GROUND LEVEL
29
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
30
Technical design guidefor WATERPROOFING
3
1
8
1
4
9
10
67 5
2
6
11
Waterproofed intermediatefloor - Topdown construction
Code:ATE N SQ 021
NEW CONSTRUCTIONSBELOW GROUND LEVEL
31
NE
W C
ON
STR
UC
TIO
NS
NEW CONSTRUCTIONSBELOW GROUND LEVEL
32
Technical design guidefor WATERPROOFING
MAPEPROOF on slab andPLASTIMUL on wall
Code:ATE N SQ 023
1
23
4
5
6
7
9
811
10
3
NEW CONSTRUCTIONSBELOW GROUND LEVEL
33
NE
W C
ON
STR
UC
TIO
NS
MAPEPROOF - inverted beam Code:ATE N SQ 024
1
2
3
4
7
5
9
8
2
6
NEW CONSTRUCTIONSBELOW GROUND LEVEL
34
Technical design guidefor WATERPROOFING
NEW CONSTRUCTIONSBELOW GROUND LEVEL
35
NE
W C
ON
STR
UC
TIO
NS
Front edge of a balcony -marble sill
Code:ATE N FQ 001
NEW CONSTRUCTIONSABOVE GROUND LEVEL
36
Technical design guidefor WATERPROOFING
Front edge of a balcony -ceramic sill
Code:ATE N FQ 002
NEW CONSTRUCTIONSABOVE GROUND LEVEL
37
NE
W C
ON
STR
UC
TIO
NS
Front edge of a balcony -parapet on floor slab
Code:ATE N FQ 003
NEW CONSTRUCTIONSABOVE GROUND LEVEL
38
Technical design guidefor WATERPROOFING
Front edge of a balcony -parapet
Code:ATE N FQ 004
NEW CONSTRUCTIONSABOVE GROUND LEVEL
39
NE
W C
ON
STR
UC
TIO
NS
Balcony sillsill - frame
Code:ATE N FQ 005
NEW CONSTRUCTIONSABOVE GROUND LEVEL
40
Technical design guidefor WATERPROOFING
Codice:ATE N FQ 003Floor - wall fillet Code:ATE N FQ 006
NEW CONSTRUCTIONSABOVE GROUND LEVEL
41
NE
W C
ON
STR
UC
TIO
NS
Codice:ATE N FQ 003
Code:ATE N FQ 007
Floor - bituminous fillet
NEW CONSTRUCTIONSABOVE GROUND LEVEL
42
Technical design guidefor WATERPROOFING
Codice:ATE N FQ 003
Code:ATE N FQ 008
Flooring - insulating panel
NEW CONSTRUCTIONSABOVE GROUND LEVEL
43
NE
W C
ON
STR
UC
TIO
NS
Sealing structural joint- MAPEBAND TPE
Code:ATE N FQ 009
NEW CONSTRUCTIONSABOVE GROUND LEVEL
44
Technical design guidefor WATERPROOFING
Sealing a check jointMAPEBAND
Code:ATE N FQ 010
NEW CONSTRUCTIONSABOVE GROUND LEVEL
45
NE
W C
ON
STR
UC
TIO
NS
Structural jointflooring - wall
Code:ATE N FQ 011
NEW CONSTRUCTIONSABOVE GROUND LEVEL
46
Technical design guidefor WATERPROOFING
Drain Lateral Code:ATE N FQ 012
NEW CONSTRUCTIONSABOVE GROUND LEVEL
47
NE
W C
ON
STR
UC
TIO
NS
Drain Vertical Code:ATE N FQ 013
NEW CONSTRUCTIONSABOVE GROUND LEVEL
48
Technical design guidefor WATERPROOFING
Drain Front Code:ATE N FQ 014
NEW CONSTRUCTIONSABOVE GROUND LEVEL
49
NE
W C
ON
STR
UC
TIO
NS
Front edge of a balcony -thermal insulation
Code:ATE N FQ 015
NEW CONSTRUCTIONSABOVE GROUND LEVEL
50
Technical design guidefor WATERPROOFING
Internal liningMAPEPROOF and MAP. FOUNDATION
Code:ATE R SQ 001
REPAIRINGBELOW GROUND LEVEL
51
RE
PA
IRIN
G
Internal lining on a foundationslab and wall - MAPEPROOF
Code:ATE R SQ 002
REPAIRINGBELOW GROUND LEVEL
52
Technical design guidefor WATERPROOFING
Code:ATE R SQ 003
Sealing penetrations without waterin pressure
3
4
51
2
1
3
4
5
8 cm
8 cm
6 cm
REPAIRINGBELOW GROUND LEVEL
53
RE
PA
IRIN
G
Code:ATE R SQ 004Structural joint - wall and slab
10cm
5cm
8
9
2
6
3
4
5
10
11
7
1
REPAIRINGBELOW GROUND LEVEL
54
Technical design guidefor WATERPROOFING
Internal liningMAPEPROOF and MAP. FOUNDATION
Code:ATE R SQ 005
REPAIRINGBELOW GROUND LEVEL
55
RE
PA
IRIN
G
Front edge of a balcony with sill -waterproofing on existing flooring
Code:ATE R FQ 001
REPAIRINGABOVE GROUND LEVEL
56
Technical design guidefor WATERPROOFING
Code:ATE R FQ 002
Junction internal sill - flooringwaterproofing on existing flooring
REPAIRINGABOVE GROUND LEVEL
57
RE
PA
IRIN
G
Front edge of a balcony - parapetwaterproofing on existing flooring
Code:ATE R FQ 003
slope
REPAIRINGABOVE GROUND LEVEL
58
Technical design guidefor WATERPROOFING
Junction flooring - wallwaterproofing on existing flooring
Code:ATE R FQ 004
REPAIRINGABOVE GROUND LEVEL
59
RE
PA
IRIN
G
Check jointwaterproofing on existing flooring
Code:ATE R FQ 005
REPAIRINGABOVE GROUND LEVEL
60
Technical design guidefor WATERPROOFING
Drain Verticalwaterproofing on existing flooring
Code:ATE R FQ 006
REPAIRINGABOVE GROUND LEVEL
Horiz
onta
l and
ve
rtica
l sur
face
s
Fille
ts
Join
ts
Cros
s-m
embe
rs
Drai
ns
BATHROOMS and DAMP ENVIRONMENTSMapelastic •Mapelastic Smart •Mapelastic AquaDefense •Mapegum WPS •Monolastic •Mapeband • • •Mapeband PE 120 • • •Drain Lateral •Drain Vertical •SWIMMING POOLSMapelastic •Mapelastic Smart •Mapeproof Swell •Mapeband • •Mapeband TPE •Drain Vertical •BALCONIES and TERRACESAquaflex Roof* •Aquaflex Roof HR* •Mapelastic •Mapelastic Smart •Mapelastic AquaDefense •Monolastic •Mapenet 150 •Mapetex Sel •Mapeband • •Mapeband TPE •Drain Lateral •Drain Vertical •Drain Front •
* Exposed waterproofing layers
BATHROOMS, DAMP ENVIRONMENTS, SWIMMING POOLS, BALCONIES and TERRACES
Plat
eau
Post
-cas
t wal
ls
Pre-
cast
wal
ls
Reinf
orce
d co
ncre
te
walls
with
neg
ative
lift
Bric
k w
alls
with
ne
gativ
e lif
t
Lift
shaf
t
Pile
hea
ds
Stru
ctur
al jo
int
Cons
truct
ion
join
t
Thro
ugh
bodi
es
UNDERGROUND STRUCTURESMapeproof • • • • •Mapeproof LW • • • • •Mapeproof Mastic • •Mapeproof Swell • • • •Idrostop • • •Idrostop B25 • • • •Idrostop Soft • • • •Mapeband • •Mapeband TPE •Idrostop PVC BI-BE •Idrosilex •Idrosilex Pronto • • • •Mapelastic Foundation • • • •Lamposilex • • • •Resfoam 1KM • • • •Plastimul •Plastimul 1K Super Plus •Plastimul 2K Plus •Plastimul 2K Super •
• After carrying out the render with Planitop HDM Maxi.
UNDERGROUND STRUCTURES
Technical design guidefor WATERPROOFING
HEAD OFFICEMAPEI S.p.A. Via Cafiero, 22 - 20158 MilanTel. +39-02-37673.1 Fax +39-02-37673.214Internet: www.mapei.comE-mail: [email protected]
Technical design guide
for WATERPROOFING
Tech
nica
l des
ign
guid
e fo
r WAT
ERPR
OOFI
NG
C.P
. MK
693
730
- (G
B) 1
0/20
12