    Teamcenter Engineering Client Installation

    Donaldson

    Windows

    Client Installationfor

    Teamcenter EngineeringV9.1.2.9

    Revision 1 Page 1 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    2/15

    Teamcenter Engineering Client Installation

    Pre-Installation Steps

    Redirect master environment variables AND user environment variables TMPand TEMP to C:\temp

    Create an administrative OS account forinfodba user. Perform all the following

    steps as infodba user. Install Unigraphics NX4 at C:\UGS\NX4

    Assume that D:\ is the CD drive

    For both infodba user and client user, map T:\ to \\benjamin.dci.com\usr1

    For both infodba user and client user, map R:\ & M:\ drives according to thefollowing chart:

    Site R:\ M:\

    Bloomington ---- \\michael.dci.com\im_prdnt

    Nicholasville \\nicholky.dci.com\users \\miloky.dci.com\im_prdnt

    Baldwin \\baldwinw.dci.com\users \\luckwi.dci.com\im_prdnt

    These drives are the directories where the clients will map to for engineering library filesand database environment.

    Revision 1 Page 2 of 15 Last updated 4/24/2007

    http://benjamin.dci.com/usr1http://benjamin.dci.com/usr1
  • 8/2/2019 TcEng9129 Client Install

    3/15

    Teamcenter Engineering Client Installation

    Install Portal Viewer

    Using the UGS supplied CD Teamcenter Engineering Portal Visualization 9.1.2

    Run D:\setup.exe

    Change the installation path to C:\UGS\PortalVisualization\9_1 as shown

    below:

    Next>

    Portal Viewer installation will complete.

    Revision 1 Page 3 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    4/15

    Teamcenter Engineering Client Installation

    Install Teamcenter 9.1.2.0 Application (IMAN_ROOT)

    Using the UGS supplied CD Windows Teamcenter Engineering Version 9.1.2

    Autorun should start D:\iman0912\setup.exe

    In the dialog below choose Custom:

    Revision 1 Page 4 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    5/15

    Teamcenter Engineering Client Installation

    In the dialog above select Load Teamcenter Engineering Files ONLY.

    Next>

    In the dialog below the source directory should automatically be identified asD:\iman0912

    Revision 1 Page 5 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    6/15

    Teamcenter Engineering Client Installation

    In the dialog below enterC:\UGS\TcEng91 as the target location as shownbelow.

    Teamcenter application installation will complete.

    Revision 1 Page 6 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    7/15

    Teamcenter Engineering Client Installation

    Upgrade Teamcenter Application (IMAN_ROOT) to Version 9.1.2.9

    We have copied all the upgrade files to their appropriate directories and taken asnapshot of those changes on a DCI Upgrade CD. Also on this snapshot are someDonaldson specific changes.

    Delete C:\UGS\TcEng91 directory Using the Donaldson Bloomington supplied CD DCI TcEng V9.1.2.9 Upgrade

    Copy D:\TcEng91 directory to C:\UGS\TcEng91

    Install the Portal Client

    Using the UGS supplied CD Windows Teamcenter Engineering Version 9.1.2

    Do not use the Autorun. Instead execute the following file :D:\portal\two_tier\client_lse\setup.exe

    Revision 1 Page 7 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    8/15

    Teamcenter Engineering Client Installation

    Revision 1 Page 8 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    9/15

    Teamcenter Engineering Client Installation

    In the dialog below select Portal Client, NX Manager Unigraphics, and PortalVisualization. Change the Destination Folder to C:\UGS\Portal91 by selectingBrowse button.

    In the dialog below choose Direct Access for help file location

    Revision 1 Page 9 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    10/15

    Teamcenter Engineering Client Installation

    Set the path for Help according to the following to T:\library\imanhlp9 as shownbelow:

    In the dialog below the Port should automatically be set to 1572. The Node

    should automatically be set to the . The Domain shouldautomatically be set according to the domain defined on the machine.

    Revision 1 Page 10 of 15 Last updated 4/24/2007

    This will be the nameof each client.

  • 8/2/2019 TcEng9129 Client Install

    11/15

    Teamcenter Engineering Client Installation

    In the dialog below the location for Teamcenter application (IMAN_ROOT) shouldbe filled in automatically as C:\UGS\TcEng91

    Set the TcEng DATA (IMAN_DATA) path to M:\ as shown below:

    Revision 1 Page 11 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    12/15

    Teamcenter Engineering Client Installation

    In the dialog below enter a name that identifies the database during login asshown in the chart:

    Site Name

    Bloomington PROD09

    Nicholasville PROD26

    Baldwin PROD34DIFS PROD23

    Mexico PROD35

    Thailand PROD30

    Europe(Leuven) PROD31

    In the dialog below choose No

    Revision 1 Page 12 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    13/15

    Teamcenter Engineering Client Installation

    In the dialog below the path for NX4 should be displayed automatically asC:\UGS\NX4

    In the dialog below choose the appropriate license level for the Portal Viewer.Professional should be the correct value at this time.

    Revision 1 Page 13 of 15 Last updated 4/24/2007

    C:\UGS\NX4

  • 8/2/2019 TcEng9129 Client Install

    14/15

    Teamcenter Engineering Client Installation

    Portal installation will complete.

    Revision 1 Page 14 of 15 Last updated 4/24/2007

  • 8/2/2019 TcEng9129 Client Install

    15/15

    Teamcenter Engineering Client Installation

    Upgrade the Portal Client to V9.1.2.9

    Using the Donaldson Bloomington supplied CD DCI TcEng V9.1.2.9 Upgrade

    Copy the contents ofD:\Portal91 to C:\UGS\Portal91. Overwrite existing files.This procedure will upgrade portal and also reduce user visibility to unused

    Teamcenter applications on the left side of the screen.

    Shortcut

    Using the Donaldson Bloomington supplied CD DCI TcEng V9.1.2.9 Upgrade

    Copy the shortcut D:\Tceng_common\Teamcenter Engineering to the desktop.

    Edit the Teamcenter Engineering shortcut and redirect according to the followingchart:

    Site Shortcut

    Bloomington T:\library\nx4\start_tceng.bat

    Nicholasville R:\library\nx4\start_tceng.bat

    Baldwin R:\library\nx4\start_tceng.bat

    Remove Teamcenter Engineering from the Windows StartPrograms list.We want the users using the start scripts to get the correct environment.