tavi report · ct · study date: 10 aug 2015 11:08 …...made with osirix page 1/2 1 3 2 4 7 6 tavi...

2
Made with OsiriX Page 1/2 1 3 2 4 7 6 TAVI Report · CT · Study date: 10 Aug 2015 11:08 TAVIX (17 AUG 1937) Report date 23 Sep 2015 Accession Number A10089564322 Patient ID 170586 Referring Physician Joris Heuberger Observations Aortic Root Dimension 1. Ascending Aorta ø 3.950 cm 2. Sino-tubular junction ø 2.695 cm 3. Sinus of Valsalva ø 3.080 cm ø 2.794 cm ø 3.285 cm 4. Aortic valve annulus Width: 2.464 cm Height: 2.024 cm Area: 4.084 cm 5. Aortic valve Calcification Score: > 3000 Number of Cusps: Tricuspid Relative distance of the coronary ostia to the aortic valve annular plane 6. Left main ostium Distance: 1.601 cm 7. Right coronary ostium Distance: 1.897 cm Peripheral arteries and thoracic aorta 8. Thoracic aorta Min. ø 2.610 cm Regular diameter, without signifiant atheromatosis. 9. Abdominal aorta Min. ø 1.611 cm Discreet atheromatosis. No aneurysm. 10. Left iliac artery Min. ø 0.919 cm Tortuosity Score: Severe 11. Right iliac artery Min. ø 0.791 cm Tortuosity Score: Moderate Optimal Projection Angle S-I: -1.0° L-R: -1.8° Roll: 0.3° Conclusion This CTA study shows no contraindication for the TAVI procedure. The right iliac artery access is easier. The recommended size for the prothetic valve is 4A.

Upload: others

Post on 08-Feb-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Made with OsiriX Page 1/2

1

3

2

4

7

6

TAVI Report · CT · Study date: 10 Aug 2015 11:08TAVIX (17 AUG 1937)Report date 23 Sep 2015Accession Number A10089564322Patient ID 170586Referring Physician Joris Heuberger

Observations

Aortic Root Dimension

1. Ascending Aorta ø 3.950 cm2. Sino-tubular junction ø 2.695 cm3. Sinus of Valsalva ø 3.080 cm

ø 2.794 cmø 3.285 cm

4. Aortic valve annulus Width: 2.464 cmHeight: 2.024 cmArea: 4.084 cm

5. Aortic valve Calcification Score: > 3000Number of Cusps: Tricuspid

Relative distance of the coronary ostia to the aortic valve annular plane

6. Left main ostium Distance: 1.601 cm7. Right coronary ostium Distance: 1.897 cm

Peripheral arteries and thoracic aorta

8. Thoracic aorta Min. ø 2.610 cmRegular diameter, without signifiant atheromatosis.

9. Abdominal aorta Min. ø 1.611 cmDiscreet atheromatosis. No aneurysm.

10. Left iliac artery Min. ø 0.919 cmTortuosity Score: Severe

11. Right iliac artery Min. ø 0.791 cmTortuosity Score: Moderate

Optimal Projection Angle

S-I: -1.0°L-R: -1.8°Roll: 0.3°

Conclusion

This CTA study shows no contraindication for the TAVI procedure.

The right iliac artery access is easier.

The recommended size for the prothetic valve is 4A.

Tavix (17 Aug 1937) - TAVI Report - Study Date: 10 Aug 2015 11:08

Made with OsiriX Page 2/2

1. Ascending Aorta ø 3.950 cm

2. Sino-tubular junction ø 2.695 cm

3. Sinus of Valsalva 4. Aortic valve annulus 5. Aortic valve

6. Left main ostium (1.601 cm) 7. Right coronary ostium (1.897 cm)

8. Thoracic aorta (min. ø 2.610 cm)

9. Abdominal aorta (min. ø 1.611 cm)

10. Left iliac artery (min. ø 0.919 cm) Tortuosity

11. Right iliac artery (min. ø 0.791 cm)