Tau mass measurement at BESIII Zhang Jianyong On behalf of BESIII collaboration The 15 th international workshop on tau lepton physics

Upload: others

Post on 20-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Tau mass measurement

at BESIII

Zhang Jianyong

On behalf of BESIII collaboration

The 15th international workshop

on tau lepton physics

Page 2: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Outline

2018/09/24-28 Zhang Jianyong 2

Motivation

BEPCII and BESIII

Beam energy measurement system

Data taking scenario

Tau mass measurement at BESIII

Summary

Page 3: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Motivation

3

Mt is a fundamental parameter of the standard model

)νeνBr(μ

)νeνBr(τ

m

m

τ

τ

G

G5

τ

μ

τ

2

μ

τ μ

e,μ: ∆m/m ~10-8 , t: ∆m/m ~9.0 10-5

Lepton universality test:

Sensitive to mt5

2018/09/24-28 Zhang Jianyong

Beam energy measurement system is built to determine

the energy precisely

Page 4: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

BEPCII and BESIII

2018/09/24-28 Zhang Jianyong 4

BEPCII

Energy region: 2.0 ~ 4.6GeV

Luminosity: 1033 cm-2s-1

1.89GeV

bunch: 2×93

current: 2×0.91A

BESIII

DC:position:135 μm,

momentum:0.5%@1GeV,

σdE/dx:6%

EMC:2.5%@1GeV

6 (9) mm

TOF:65 ps (B)

60 ps(EC)

μ counter : 9 layers (B)

8 layers(EC)

TOF

MDC

CsI

RPC

SC magnet

1 T

Page 5: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Outline

2018/09/24-28 Zhang Jianyong 5

Motivation

BEPCII and BESIII

Beam energy measurement system

Data taking scenario

Tau mass measurement at BESIII

Summary

Page 6: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Beam energy measurement

system (BEMS)

2018/09/24-28 Zhang Jianyong 6

Head on collision, backscattered

photons :

We get the beam energy:

Page 7: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

BEMS layout at BEPCII north

crossing point

2018/09/24-28 Zhang Jianyong 7

Page 8: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

2018/09/24-28 Zhang Jianyong 8

Laser and optical system

Vacuum chamber

Connection between laser and vacuum

HPGe detection system

Installation of BEMS

Page 9: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Detection system

2018/09/24-28 Zhang Jianyong 9

Ortec n type coaxial HPGe detector

Typical parameter of HPGe detector

● Φ: 6 cm, height 6 cm

● Energy resolution δω/ω: 10-3

● relative efficiency: 30%

lead and paraffin are added to suppress

neutrons and low energy photons

The detector is connected to multichannel

analyzer with Ortec DSpec ProTM

(integrated nonlinearity ±250 ppm)

Page 10: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Detector calibration

2018/09/24-28 Zhang Jianyong 10

Page 11: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Detector calibration(II)

2018/09/24-28 Zhang Jianyong 11

The nonlinearity of multichannel analyzer's scale is

calibrated using the precise pulse generator (BNC-PB5)

with integral nonlinearity ±15 ppm jitter ±10 ppm

Interested energy are wide and radiation sources are limited

Page 12: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Detector calibration(III)

2018/09/24-28 Zhang Jianyong 12

By tuning parameters p0 and p1 and comparing the

reference lines and pulser lines :

Page 13: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Calibration and Compton edge fit

2018/09/24-28 Zhang Jianyong 13

Page 14: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Outline

2018/09/24-28 Zhang Jianyong 14

Motivation

BEPCII and BESIII

Beam energy measurement system

Data taking scenario

Tau mass measurement at BESIII

Summary

Page 15: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Data taking scenario

2018/09/24-28 Zhang Jianyong 15

J/Ψ scan for BEMS calibration and beam energy

spread measurement (7 points)

Three stages:

tau mass scan near tau threshold (5 points)

Ψ’ scan for BEMS calibration and beam energy

spread measurement (7 points)

Page 16: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Data taking scenario (II)

2018/09/24-28 Zhang Jianyong 16

Three energy regions:

Low energy region Point 1, 14 pb-1, to determine

background

Near threshold Point 2, 39 pb-1 and point 3,

26 pb-1, to determine tau mass

High energy region Point 4, 7 pb-1 for Χ2 check

Point 5, 14 pb-1 to determine

detection efficiency

Total lum. ~100pb-1,

uncertainty: 0.1MeV

We obtain more than 130 pb-1

tau scan data!

Page 17: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Event selection

2018/09/24-28 Zhang Jianyong 17

eμ:

Two good charged tracks

|vz | < 10 cm, |vrxy| < 1 cm , |cos(θ)| < 0.93

0.05 < p < 1.1GeV

No good neutral tracks

Muons:

E/p < 0.8, 0.1<E<0.3, MuC hit >0, Δtof (μ) < 0.35 ns

Electrons:

0.8 < E/p < 1.1, Δtof (e) < 0.35 ns

eπ: Pions:

E/p < 0.8, 0.7<p<1.1, Not μ, Δtof (μ) < 0.35 ns

Page 18: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Tau mass fit

2018/09/24-28 Zhang Jianyong 18

Tau mass is obtained using maximum likelihood fit

Free parameters are: Mt, ε, σbg

Systematic uncertainty is in progress

The statistic error of two modes (eμ, eπ) is about 70 keV

Page 19: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

tau mass scan at BESIII in 2011

2018/09/24-28 Zhang Jianyong 19

Systematic errors

Source keV

Theo. 10

ESpread 16

EScale

ESelection 50

Eff. 48

Bg.

shape

40

Lum. 6

Sum Mτ = 1776.91 ± 0.12 (stat.) (sys.) MeV

PDG2012: 1776.82 ±0.16 MeV Mτ = 0.171 MeV, Mτ / Mτ = 9.6 10–5

+ 0.10 - 0.13

PRD 90, 012001 (2014)

23.4 pb-1,13 modes

+22

-86

-130

+100

Page 20: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Data comparison

2018/09/24-28 Zhang Jianyong 20

In 2011, two modes(eμ,eπ) , 454 events, extend 13 decay modes,

We obtained 1171 events

σstat. will be decrease to

σsyst is estimated to be 0.090 MeV if σtotal is required to be less

than 0.1 MeV

0.070

1171/454 = 0.044 MeV

Page 21: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

Summary

2018/09/24-28 Zhang Jianyong 21

Beam energy measurement system is commissioning well

at BEPCII

Tau threshold scan was performed at BESIII this spring,

more than 130 pb-1 data were collected

The further study on statistic and systematic uncertainty

are in progress, the total uncertainty of tau mass is expected

to be less than 0.1 MeV

Page 22: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

2018/09/24-28 Zhang Jianyong 22

Thank you for your concern!

Page 23: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

tau mass scan @BESIII in 2011

2018/09/24-28 Zhang Jianyong 23

In order to check the performance of the

detector, the physical software and the

BEMS, the t scan was performed in the

winter of 2011.

to resonances J/ψ and ψ’ ,7 points are

scanned, the integral luminosity are 1.5

pb-1, 7.0 pb-1 separately

4 points near t threshold are

scanned, 23.4 pb-1

PRD 90, 012001 (2014)

Page 24: Tau mass measurement at BESIII · 2018. 11. 22. · tau mass scan @BESIII in 2011 2018/09/24-28 Zhang Jianyong 23 In order to check the performance of the detector, the physical software

2018/09/24-28 Zhang Jianyong 24

PRD 90, 012001 (2014)

tau mass scan @BESIII in 2011