tasman contracting ltd - quickflash quickflash brochure 2017.pdf · tapered upstand. this flashing...

8
W & 108 March 2017 Codes 03, 13, 33 & 40 Codes 04, 14, 34 & Box Flashing Codes 23, 37, 42 & 52 Codes 06 & 36 Codes 05 & 31 Code 19 Codes 04, 14, 34 & Box Flashing Codes 06, 08, 12, 20, 21, 22, 27, 28 & 29 Codes 06, 24b, 43, 49, 50 & 51 Codes 03, 13, 33, 40, 107 & 108 Codes 06 & 12 Codes 04, 14, 25, 34 & Box Flashing Codes 107 Codes 05, 35 & 41 Codes 07 & 38 Codes 101, 102, 103, 104, 105 & 106 Codes 02, 03, 13, 17, 18, 33, 40 & Box Flashing Codes 05, 32 & 35 Code 100 Code 09 Codes 02 & 40 Codes 06, 24b, 43, 49, 50 & 51 Codes 02, 05, 31 & 41 Codes 01, 06, 10 & 30 Codes 39, 41 & Box Flashing TASMAN CONTRACTING LTD 15 CARLYON ROAD, RD 1 UPPER MOUTERE, NELSON 7173 PH: 03 543 2145 FAX: 03 543 2146 EMAIL: [email protected] The Most Compreh v all Flashing System e i s n e

Upload: ngohanh

Post on 25-Aug-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

W

& 108

March 2017

Codes 03, 13, 33 & 40

Codes 04, 14, 34 & Box Flashing

Codes 23, 37, 42 & 52

Codes 06 & 36

Codes 05 & 31

Code 19

Codes 04, 14, 34 &Box Flashing

Codes 06, 08, 12, 20, 21, 22,27, 28 & 29

Codes 06, 24b, 43, 49, 50 & 51

Codes 03, 13, 33, 40, 107 & 108

Codes 06 & 12

Codes 04, 14, 25, 34 & Box Flashing

Codes 107

Codes 05, 35 & 41

Codes 07 & 38

Codes 101, 102, 103, 104, 105 & 106

Codes 02, 03, 13, 17, 18, 33, 40 & Box Flashing

Codes 05, 32 & 35

Code 100

Code 09

Codes 02 & 40

Codes 06, 24b, 43, 49, 50 & 51

Codes 02, 05, 31 & 41

Codes 01, 06, 10 & 30

Codes 39, 41 & Box Flashing

TASMAN CONTRACTING LTD15 CARLYON ROAD, RD 1 UPPER MOUTERE, NELSON 7173

PH: 03 543 2145 FAX: 03 543 2146 EMAIL: [email protected]

The Most Compreh v all Flashing System

eisne

admin_2
Typewriter
Copyright Quickflash 2017
admin_2
Typewriter
admin_2
Typewriter
Page 2: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

12

( Cavity only )

( 0.55mm Z450 )

( 0.55mm )Flashings are available in :

GALVANISED STEEL

COLORSTEEL MAXX

STAINLESS STEEL

( 0.7mm 5000 series )

90mm Wall framing Cavity

H3.1 battens

50x50mmcorner flashing

Wall underlay

Cladding

20 or 35mm

30mm

65mm

10mm

25mm

Wall framing

50x50mm cornerflashing

Wall underlayH3.1 battens

CladdingCavity

90mm

Code 02Framing

Mesh

Wall clading

25mm solid plaster

Rigid or non-rigid backing

Cavity

Wall underlay

Edge flashing fastenedwith clouts

Drip point for cladding

Plaster finish to foundation

Mesh

Ventilation for cavity

Fasten with clouts @600mm crs.Bottom plate

Wall underlay

Rigid backing25mm solid plaster

20mm or 35mm x 50mmcavity battens

Foundation

Patent532534NZ

AVAILABLE IN :

AVAILABLE IN :

AVAILABLE IN :

Z450 Galv, Colorsteel Maxx & Stainless Steel.AVAILABLE IN :

( Code 03 shown )

( External joiners available Code 15 & 16 )

( 50x50mm )Code 14

( 90x90mm )Code 04

This flashing goes directly behind the cladding toprovide extra protection at an internal corner.

( 50x50mm )Code 13

Code 03

Internal Corner Flashing

This flashing forms a clean edge where solidplaster meets another form of cladding.

This flashing forms a rigid straight base for the solidplaster to finish to. It also vermin proofs the cavity whilestill allowing for air movement and any moisture to escapeby means of 5mm Dia. holes along the underside.

( Stucco 35mm Cavity )Code 10

( 0.5mm 304 )

( Colour Thunder Grey only )

ALUMINIUM

QUICKFLASH

All flashings come in 3.0m lengths with the exception of joiners and saddle flashings

Code 01 ( Stucco 20mm Cavity )

Base and Cavity Closure Flashing

Edge Flashing

( 90x90mm )

External Corner Flashing

( 70x110mm offset)Code 40

( Code 04 shown )

This flashing goes directly behindthe cladding to provide extraprotection at an external corner.

( Direct fix or Cavity )

( Direct fix or Cavity )

( Direct fix or Cavity )

1

( End caps available Code 44 & 45 )

( Note:- Stucco & Aluminium are not compatible.)

Aluminium may be used with other claddings

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ AppraisedAppraisal No.688 (2011)

BRANZ Appraised

Appraisal No.688 (2011)

BRANZ Appraised

Appraisal No.688 (2011)

BRANZ Appraised

Appraisal No.688 (2011)

Flashing 50mmbelow floor min.

admin_2
Typewriter
Copyright Quickflash 2017
Page 3: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

50mm

13mm

77mm

( Code 06 shown )

Sill brick

Air sealAluminium window

Wall underlay

Brick veneer

Brick ties

Code 09 sill flashing

30mm

( 30mm cladding or cavity +10mm cladding )

This flashing is used to form horizontal breaks incladdings either with cavities or direct fix

Code 12

Code 08

Horizontal Control Joint Flashing

( Code 08 shown )

( 50mm cladding or cavity +30mm cladding )

25mm

20mm

Wall underlay

Cavity

Vented cavity top flashing

Cladding( Cavity only )

This flashing ventilates the top ofthe cavity while restricting waterentry. It also gives a cleanstraight finish to stucco cladding.It can also be used to ventilatethe soffit area or under anenclosed deck.

Code 07

Vented Cavity Top Flashing

Foundation / floor

Framing

Bottom plate

20 or 35mmcavity batten

Wall underlay

Drip point for cavity

Cladding

20 or 35mm

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ AppraisedAppraisal No.688 (2011)

( Cavity only )

AVAILABLE IN :

AVAILABLE IN :

AVAILABLE IN :

AVAILABLE IN :

( 35mm Cavity )

( 20mm Cavity )

( Direct fix or Cavity )

2

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Z450 Galv, Colorsteel Maxx & Stainless Steel.

BRANZ AppraisedAppraisal No.688 (2011)

BRANZ Appraised

Appraisal No.688 (2011)

BRANZ Appraised

Appraisal No.688 (2011)

( Direct fix or Cavity )

( Code 05 shown )

Code 09

This flashing vermin proofs the cavity while stillallowing for air movement and any moisture toescape by means of 5mm Dia. holes @ 15mmCrs. Can be used with most claddings.

Code 11

Code 06

Code 05

Brick Sill Flashing

Cavity Closure Flashing

This flashing goes behind verticalcontrol joints to prevent moisturegetting back into the cavity orframing. It can also be used as awindow jamb flashing.

Vertical Control Joint Back Flashing

This flashing directs any water awayfrom the dry side of the cavity towardsthe back of the brick veneer.

( 90mm )

Code 41 ( 130mm )

( Cavity only )

AVAILABLE IN : Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Glass

5mm Sealant

10mm min.

Crack

rigid backing

100x20 H3.1 batten Wall underlay

Solid plaster

Mesh

90mm Aluminium window frame

Back flashing

Cavity

Patent 532647NZ

Rafter

Cladding

Wall underlay

Cavity

Soffit lining

Wall framing

5mm gap

Code 30 Horizontal Base Flashing

Code 12 Horizontal control jointflashing through cavity

20mm cavity battensCladding

Code 08 Horizontal control jointflashing on cavity or direct fix

Code 06 Cavity closure flashing

Wall underlay lappedover ' Z ' flashing

35mm

50mm

100mm

Soffit lining

Framing

admin_2
Typewriter
Copyright Quickflash 2017
admin_2
Typewriter
Page 4: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

Tapered upstand

This flashing sits flat on the trimmer with an 8mmupstand to the back edge. Both ends require a8mm tapered turn up to be folded on site.

( Direct fix )

( Aluminium window Flat )

Code 52 Frame block

Cladding

5mm gap without seal

Sill flashing to extend behindaluminium extrusion with an8mm upstand to back andtapered turn ups to both ends

8mm min. cover to joinery

35mm min. cover to cladding

Cladding

Wall underlay andflashing tape

20mm min. upstand at bothends of sill flashing

5mm gap without seal

Sill flashing (Code 42) with35mm cover to cladding

35 slope

AVAILABLE IN : Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ Appraised

Appraisal No.688 (2011)

Code 42

Sill Flashings

( Timber window 35 degree fall )

88mm

35mm

( Direct fix )

BRANZ Appraised

Appraisal No.688 (2011)

110mm

10mm

70mm

This flashing protects the stringerjoist fastened to, or along the sideof the building, forcing water todrip away from the joist.

Deck Flashing

Code 19

( Direct fix or Cavity )Non-cantilevered Joists

Horizontal ' Z ' flashing

Deck flashing to formdrip line out from wall

Decking

Bottom plate

Wall underlay

Cavity

Code 06 Cavity closure flashing

15mm min.

58mm

35mm

50mm

cavity

Cladding

H3.1 battens

Wall underlay

Internal corner fillet flashing

Wall framing

15mm

( Direct fix or Cavity )( Code 17 shown )

Code 18

Code 17

( up to 40mm cladding )

Internal Corner Fillet Flashing

( up to 15mm cladding )

This flashing goes directly behind the cladding toprovide extra protection at an internal corner whileproviding a straight face for the cladding to finish to.

AVAILABLE IN :

AVAILABLE IN :

3

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ AppraisedAppraisal No.688 (2011)

BRANZ Appraised

Appraisal No.688 (2011)

Z450 Galv, Colorsteel Maxx & Stainless Steel.AVAILABLE IN :

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

( Aluminium window 5 degree fall )

Code 23

Code 16

Code 15

External corner joiners for Codes 01 & 10 which slideover the base flashings, then pop riveted into place.

( for code 10 )

( for code 01 )

Base and Cavity Joiner

( Direct fix )

External corner joiner

Base & Cavity Closure Flashings

Rivet Rivet

35mm cover to cladding

10mm minimum joinerycover to flashing

Sill flashing to back of windowframe with 20mm minimumupstand to both ends.

5mm gap without seal

Cladding

Chamfer trimmerplate as required with wall underlayand flashing tapeover

Sill flashing with 5degree minimum fall

35mm

8mm

70mm

5 slope

Flat

This flashing has a 5 degree slope and ahem to the back edge. Both ends requirea 20mm turn up to be folded on site.

This flashing has a 35 degree slope and ahem to the back edge. Both ends require a20mm turn up to be folded on site. We canchange this angle on request if necessary.

admin_2
Typewriter
Copyright Quickflash 2017
Page 5: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

35mmCavity spacers set to fall

Horizontal Z flashing

Sheet cladding

10mm expansion gap

Wall underlay

6, 7.5, 10, 12, 20, 40mm

AVAILABLE IN :

( Direct fix or Cavity )

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ Appraised

Appraisal No.688 (2011)

( 10mm cladding )Code 29

( 7.5mm cladding )Code 28

( 6mm cladding )Code 27

Horizontal 'Z ' Flashing

( 12mm cladding )Code 20

Code 21

Code 22

( 20mm cladding )

( 40mm cladding )

20mm

15mm

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

( 24b only )

( Direct fix or Cavity )

( Head flashing 40mm )

( Cavity closure )

Code 24 B

Part 'A' can also be used with Code 12as a Horizontal Control Joint Flashing.

( Part A cavity only )

Part ' B ' is designed to work in withCode 31 ( Window Side Flashing )

Use 8 gauge stainless steel screws with neoprene washers

Use 8 gauge stainless steel screws with neoprene washers

5mm fixing holes @ 300mm crs each side.

5mm fixing holes @ 300mm crs each side.

135 degree internal corner available on request

135 degree external corner available on request

Code 26

Internal Corner Face Flashing

Two Piece Window Head Cavity Closure Flashing

Code 24 A

External Corner Face Flashing

Code 25

Code 43

( Head flashing 65mm )

( Direct fix or Cavity )

( Direct fix or Cavity )

AVAILABLE IN :

AVAILABLE IN :

4

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ Appraised

Appraisal No.688 (2011)

AVAILABLE IN :

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Code 24B = 67Code 43 = 41

lintels

Cavity closure flashingcode 24a5mm drainage holes @15mm crs.

Aluminium window frame

Stucco

Wall underlay

Window head flashingCode 24 B

20mm cavity

Flashing tape or a secondlayer of wall underlay to lapover head flashingA

B

Fixing holes

External Corner Face Flashing

Framing

Cladding

20x50 cavitybattens

Wall underlay

Fixing holes

Internal CornerFace Flashing

Framing

Cladding

Cavity battens

Wall underlay

BRANZ AppraisedAppraisal No.688 (2011)

Stopends to head flashing

55mm

55mm

Cavity Closure Flashing Code 06

Horizontal BaseFlashing Code 30

Mesh

20mm min.drip point

Wall underlay

Rigid backing

25mm solid plaster

Cavity battens

Foundation

Horizontal Base Flashing

Code 30

AVAILABLE IN :

( Direct fix or Cavity )

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ Appraised

Appraisal No.688 (2011)

Aluminium may be used with other claddings( Note:- Stucco & Aluminium are not compatible.)

This flashing provides a straight rigid base forsolid plaster and other claddings. It can be usedwith a window head flashing or as a baseflashing.

30mm

10mm

BRANZ AppraisedAppraisal No.688 (2011)

admin_2
Typewriter
Copyright Quickflash 2017
admin_2
Typewriter
admin_2
Typewriter
Page 6: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

40mm8mm

10mm

Aluminium window frame

Cladding

Sealant

Air seal

Window side flashing

Wall underlay

10mm cover

Cavity

AVAILABLE IN : Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Window Side Flashing

Code 31

Window side flashing can be used withsolid plaster and most other claddings.It is designed to work in with Code 24part ' B ' ( window Head Flashing )

( Direct fix or Cavity )

Patent 544166NZ

Wall framing

Recessed internal cornerback flashing

Wall underlay

Cavity batten

Cladding

CavityAVAILABLE IN :

BRANZ Appraised

Appraisal No.688 (2011)

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

Code 33

Recessed Internal Corner Back Flashing

This internal corner flashing goes directlybehind the cladding in a cavity situation,without encroaching into the cladding space.

( Cavity only )

Patent550386NZ

71mm

AVAILABLE IN : Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ Appraised

Appraisal No.688 (2011) This external corner flashing goesdirectly behind the cladding in acavity situation, without encroachinginto the cladding space.

Code 34

Recessed External Corner Back Flashing

Patent550387NZ

Wall framing

Cladding

Wall underlay

Recessed external corner back flashing

Cavity batten

Cavity

71mm

( Cavity only )

Wall framing

92mm

Recessed vertical controljoint back flashing

Wall underlay

Cavity

Cavity batten

Sealant over bondbreaker tape

AVAILABLE IN : Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ Appraised

Appraisal No.688 (2011)

This vertical control joint flashinggoes behind the cladding in a cavitysituation without encroaching intothe cladding space.

Code 35

Recessed Vertical Control Joint Back Flashing

Patent 550388NZ

( Cavity only )

5

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

( Direct fix or Cavity )

AVAILABLE IN :

Use 8 gauge stainless steel screws with neoprene washers

Vertical Control Joint Face Flashing

Code 32

This face flashing goes over avertical join in the cladding .

Fixing holes

sealant

Cavity batten

Cavity

Wall underlay

Face Flashing

Stainless steel screws with neoprene washers80mm

Wall framing

109mm

BRANZ AppraisedAppraisal No.688 (2011)

admin_2
Typewriter
Copyright Quickflash 2017
admin_2
Typewriter
admin_2
Typewriter
Page 7: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

Other angles available on request.

16mmslide in

Additional underlay orflashing tape lappedover head flashing

5mm gap

Adjustable head flashing ( Quickflash Codes 49, 50, 51 )

Wall underlay

Cladding

Aluminium window frame

lintels

Stopends to head flashing

Cavity closure flashing( Quickflash Code 06 )

Cavity

AdjustableBRANZ Appraised

Appraisal No.688 (2011)

AVAILABLE IN :

6

Aluminium.

AVAILABLE IN :

( Direct fix or Cavity )

Adjustable Head Flashing

Code 49

Code 50

Code 51

( covers 20 / 30mm )

( covers 30 / 50mm )

( covers 50 / 85mm )

A bead of MS. sealant should be run along the frontedge of the female part before inserting the malepart. This is to ensure the two parts stay in place.

cavity cavity

Plaster Weatherboard

Sealant Sealant

Quickflash Vertical Cladding Junction Flashing ( Code 39 )

Wall framing

Pop rivet

AVAILABLE IN : Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

BRANZ Appraised

Appraisal No.688 (2011)

Vertical Cladding Junction Flashing

Code 39

This flashing can be used with avariety of cladding. It forms a cleanstraight junction between two differenttypes of cladding material without theneed for scribers.

( Direct fix or Cavity )

40mm

40mm

70mm

70mm

35mm

Rafter

Wall underlay

Soffit lining

Code 38 Soffit flashing (35mm cover over cladding)

Cavity

Wall cladding

AVAILABLE IN :

BRANZ Appraised

Appraisal No.688 (2011)

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

This flashing diverts any moisture from enteringthe top of the wall space. It is usually installedafter the cladding but before the soffit lining andcan be used with most types of claddings.

Soffit Wall Junction Flashing

Code 38

( Direct fix or Cavity )

Z450 Galv, Colorsteel Maxx & Stainless Steel.

( Direct fix or Cavity )

AVAILABLE IN :

Code 37

Code 37 is used to give 35mm cover tothe top edge of solid plaster where thewindow profile fails to do this.

BRANZ Appraised

Appraisal No.688 (2011)

Aluminium window frame

Wall underlay

Stucco

Mesh

Cavity spacers set toslope 1:12 min.

Air seal

Sill flashing Code 37 ( 35mmmin. cover to stucco )

10mm min. cover to joinery

35mm

23mm

75mm

Solid Plaster Cap Flashing

Wall underlay

20mm cavity

Bevelback weatherboard

Perforated cant strip cavityclosure flashing to allow airflow & drainage

Cavity battens must sit insideflashing to give support

BRANZ Appraised

Appraisal No.688 (2011)

Z450 Galv, Colorsteel Maxx, Aluminium & Stainless Steel.

( Cavity only )

This flashing does two jobs. It verminproofs the cavity while still allowing for drainage and air movement. It alsoforms a cant strip to support thebottom bevelback weatherboard.

Code 36

Cant Strip Cavity Closure Flashing

32mm

( Timber or fibre cement )

20mm

50mm min.68mm

20mm

admin_2
Typewriter
Copyright Quickflash 2017
Page 8: TASMAN CONTRACTING LTD - Quickflash Quickflash Brochure 2017.pdf · Tapered upstand. This flashing sits flat on the trimmer with an 8mm upstand to the back edge. Both ends require

Aluminium and Galvanised steel must not come in contact with CCA, Copper azole or Copper quaternary salt treatedtimber in any of NZ exposure zones. Colorsteel Maxx and power coated Aluminium must not come in contact in exposurezones D or sea spray. A layer of bitumen-impregnated paper based heavy-duty roof underlay between the treated timberand metal flashing will minimise any adverse reaction. Stainless steel may come in contact in all exposure zones.

Appraisal No.688 (2011)

AppraisedBRANZ

60mm

110mm

235mm

50mm

100mm

135mm

Saddle flashing to extend35mm min. below joist

Depth of cantilevered joist

Continuous ' Z ' flashing

50mm

Cavity

Pop rivets

MS sealant between flashing &meter box

Wall underlay

Stopends to meter box top flashings

Air seal

Base flashing with 35mm cover overcladding

Side flashing with hem

5mm gap

Cladding

Flashing tape over ' Z ' flashing

Quickflash ' Z ' flashing with 10mm stopends

Not Included

( Direct fix or Cavity )

( Direct fix or Cavity )

Appraisal No.688 (2011)

AppraisedBRANZ

Stainless Steel.

AVAILABLE IN :

Appraisal No.688 (2011)

AppraisedBRANZ

Aluminium

Stainless Steel.

7

AVAILABLE IN :

AVAILABLE IN :

AVAILABLE IN :

( Direct fix or Cavity )

Z450 Galv with Colorsteel Maxx sill, Aluminium & Stainless Steel.

Meter box kits suit rectangular metal meter boxes thatrange in size up to 600mm wide by 700mm high. Kits willsuit most cladding types whether direct fix, 20mm cavityor 40mm cavity. Installation instructions are included withthe kit together with pop rivets and a drill bit to suit. Note:head flashing is not included as it must suit the width ofthe cladding and cavity if applicable.

Code 100

Meter Box Flashing Kit

( Other sizes available on request )

For selection of the appropriate flashing material refer to E2/AS1 - Tables 20 , 21 and 22

( Other sizes available on request )

( Double 200x50 Joists )

( 150x50 Joists )

Saddle Flashings

( Left Hand )

Code 101

Code 102 ( 200x50 Joists )

Code 103 ( 250x50 Joists )

Code 104 ( 300x50 Joists )

Code 105

Code 106 ( Double 300x50 Joists )

Parapet or Balustrade Saddle Flashings

Code 107

Code 108 ( Right Hand )

Right hand flashing shown

Left hand flashing shown

135mm

( Building wrap etc. omitted for clarity )

Capping flashing

Cladding

Saddle flashing to extend100mm along parapet

Saddle flashing

5 degree sloped packer

Cavity battensFraming

48mm

External Box Corner Cladding Change Box Flashing Internal Box Corner

Aluminium Box flashings can be made to order in a range of shapes and sizes to suite some off those awkward situations.

Aluminium Box Flashings

BRANZ appraisal No.688 (2011) covers the flashings showing the logo. These flashingshave been appraised to see if they meet the flashing requirements of E2/AS1.

admin_2
Typewriter
Copyright Quickflash 2017
admin_2