RENEWABLE ENERGY:
SOLAR POWERThe Technology &
Agilent Solution
![Page 2: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/2.jpg)
Agenda
What is solar power?
Solar market
Solar system
Solar panel produce process
Solar panel test condition
- Cell and module I-V test
- Temperature test and Switching
Inverter performance test
Summary
![Page 3: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/3.jpg)
What is SOLAR(Photovoltaic) POWER?
When a photon is absorbed by a semiconducting material, it increases
the energy of a valence band electron, thrusting it into the conduction
band. The conducting band electron then produces a current that moves
through the semiconducting material.
Cross-Section of a PV cell
+ +++- ---
-
+
![Page 4: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/4.jpg)
Outlook for 2011 PV capacity
CountryChange vs.
2010
1 Germany -
2 Italy -
3 USA +1
4 China +5
5 Japan +1
6 France -1
7 Australia +3
8 India +8
9 Spain -2
10 Canada +2
Source : IMS Research
22GW will be added this year
Rapidly falling module price
Establishing incentives in new markets
Planned cuts in existing markets by year’s end
Europe : FLAT
Asia : Roaring
Overall Europe will be down -1%
But still have 70% of global installation
Except 4 of top 10 country,
Europe ranked 11 to 15 of top country
China lead market
with just-unveiled national FIT
and Golden Sun Program
PV Installation Top 10 Country
![Page 5: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/5.jpg)
Outlook of Korea PV market
Installation scale Solar plant power sales
145.3% rapidly growth over 5 years
Due to RPS(Renewable Portfolio Standards), Korea Solar market will be increase
2012 RPS volume settled as 32.3MW
Korea Hydro and Nuclear power : 21MW
KOSEP: 4.3MW, KOIMPO: 4.0MW, KWP: 3.0MW
Source : Hanaif.re.kr
Installation
amount
Compared with
WW market
Solar cell sales
Solar cell portion of
renewable energy
72 times
increase
![Page 6: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/6.jpg)
Solar system type
Power company
LoadsInverter
Solar
Panel
DC AC
Solar
Panel Inverter
DC AC
LoadsBatteryOff-g
rid c
onnecte
d
Grid c
onnecte
d
![Page 7: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/7.jpg)
Element of Solar System example
Inverter
Power company
LoadsSolar Panel
DC AC
Grid-connected system
![Page 8: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/8.jpg)
Inverter
Power company
LoadsSolar Panel
Element of Solar System example
DC AC
Grid-connected system
Today focus area
![Page 9: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/9.jpg)
Solar Cell Type
Solar Cell
Silicon
Crystalline
Single Crystal Poly CrystalPolycrystalline
Thin Film
Amorphous Group
Compound Semiconductor
Ⅱ - Ⅵ :
CIS, CdTe
Ⅲ - Ⅴ:
GaAs, InP
Tandem :
GaAs/GE,
GaAlAs/GaAs
Thin Film Solar CellOrganic, Dye
Solar Cell
![Page 10: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/10.jpg)
Solar Panel production process
Poly SiIngot & Wafer PV Cell PV Module PV Array
Crystalline Silicon Solar Panel
![Page 11: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/11.jpg)
Solar Panel production process
Poly SiIngot & Wafer PV Cell PV Module PV Array
Crystalline Silicon Solar Panel
Energy Conversion
in Cell and ModulesInstallation
![Page 12: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/12.jpg)
Solar Panel production process
Poly SiIngot & Wafer PV Cell PV Module PV Array
Crystalline Silicon Solar Panel
Energy Conversion
in Cell and ModulesInstallation
Electrical
test need
![Page 13: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/13.jpg)
Solar Panel Test Condition
STC(Standard Test Condition)
– Incidence Irradiance : 1000Watts/m2
– Temperature of Solar cell : 25℃
– AM(Air Mass) : 1.5
PTC(PVUSA Test Condition)
– Incidence Irradiance : 1000Watts/m2
– Temperature of Ambient : 20℃
– AM(Air Mass) : 1.5
– Wind speed : 1m/s
![Page 14: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/14.jpg)
Solar Panel Test Requirement
Switching
I-V test
Temperature measure
STC : KS C IEC 60904-1
KS C IEC 60891
![Page 15: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/15.jpg)
Solar Panel Test Requirement
I-V test
KS C IEC 60904-1
![Page 16: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/16.jpg)
Solar Cell and Module Electrical Test Basics(illuminated)
Solar cell I-V curve
Solar cell DC circuit equivalent
• Open-circuit voltage (Voc)
• Short-circuit current (Isc)
• Maximum power output of the cell (Pmax)
• Voltage at Pmax (Vmax, Vmp)
• Current at Pmax (Imax, Imp)
• Conversion efficiency of the device (η)
• Fill factor (FF) = Pmax / (Voc * Isc)
• Cell diode properties
• Cell series resistance
• Cell shunt resistance
![Page 17: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/17.jpg)
Solar Cell and Module Electrical Test Basics(dark)
Solar cell Dark I-V curve
Solar cell DC circuit equivalent
• Cell diode properties
• Cell shunt resistance
PV module
Loads
PCS
Diode
Performed to ensure cell quality meets
requirments and to ensure the cell is defect free
![Page 18: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/18.jpg)
High power(up to 600W)
: N3300 Electric Load
N6060B/6063B Electric Load
Med power(up to 100W)
: 661xC or 663xB 2-quad source
Low power (up to 20W)
: N6784A 4-quad SMU
U2723A 4-quad SMU
High performance +
semiconductor parameters
: B1500A
B1505A
B2900A
-
Measure Cell/Module I-V curve
![Page 19: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/19.jpg)
Testing Solar Cells and Modules with Electronic Loads
Features that make the N3300A Series electronic loads ideal for solar test:
High power handling capability in a compact unit: the 1,800-W N3300A is a full-rack unit and the
600-W N3301A is a half-rack unit.
The 6060B and 6063B provide power handling capabilities of 300 W and 250 W and share most of
the features and specifications of the N330xA family.
Simultaneous channel measurements and simultaneous current, voltage, and power measureme
nts from a single channel for high-throughput testing
Built-in digitizer can make measurements of current or voltage vs. time
Temperature coefficient specifications make calculating accuracy for outdoor testing easy
High input stability to prevent oscillations in test setup
High-impedance external sense capability
N3300A 6060B/6063B
PV Cell PV Module
![Page 20: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/20.jpg)
Testing Solar Cells and Modules with Electronic Loads
Electronic loads typically have three modes of operation:
Constant Current (CC), Constant Voltage (CV), and Constant Resistance (CR)
Electronic loads are a great solution for solar module testing because of their wi
de power range and ability to sink large amounts of current
CV mode for I-V curve tracing allows stepping through voltages incrementally
and to measure the current output of the module under test
N3302A N3303A N3304A N3305A N3306A N3307A
Input
rating
0-30A
0-60V
150W
0-10A
0-240V
250W
0-60A
0-60V
300W
0-60A
0-150V
500W
0-120A
0-60V
600W
0-30A
0-150A
250W
Resolution(CV mode)
1mV 4mV 1mV 2.5mV 1mV 2.5mV
![Page 21: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/21.jpg)
Testing Solar Cells and Modules with Electronic Loads
Under 2Volt, Electronic Load can’t provide current
which should be consummated
![Page 22: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/22.jpg)
Testing Solar Cells and Modules with Electronic Loads
N330xA’s ability to draw current is reduced at voltag
e levels below 2 V. At 0 V, no current can flow into th
e load. Adding a simple power supply in series with
the N330xA optimizes performance.
![Page 23: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/23.jpg)
Testing Solar Cells with a Two-Quadrant Power Supply
The Agilent 661xC and 663xB DC source families provide:
High measurement accuracy
Fast response
Great output stability
Low price
For solar cell tests that demand four-quadrant type measurements, Agilent DC
sources can be easily configured with minor switching overhead to be used
like four-quadrant devices.
PV Cell PV Module
![Page 24: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/24.jpg)
Testing Solar Cells with a Two-Quadrant Power Supply
Solar Cell I-V Curve
Reverse bias region of solar cell
Solar cell electrical
characterization
test setup configured
to capture the I-V curve
of a solar cell
Solar cell electrical
characterization
test setup configured
to capture the reverse bias
electrical characterization
of a solar cell
![Page 25: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/25.jpg)
Testing Solar Cells with Paired Two-Quadrant Power Supply
![Page 26: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/26.jpg)
Testing Solar Cells with SMU(U2723A)
PV Cell
20V
-20V
120mA-120mA
3-channel USB SMU with ±20V, ±120mA each (7.2W max)
4-quadrant operation
High current sensitivity of 100pA with 16 bit resolution
0.1% basic accuracy, good for static measurement
Comes with embedded test scripts – with 2 programmable list for each channel.
Higher throughput with parallel output and shorter rise and fall time.
Working Range
![Page 27: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/27.jpg)
Testing Solar Cells with SMU(U2723A)
Program Memory Editor
IV Curve Interface
Graph DisplayChannel Configuration
Commands to be Executed Up to 100 commands
Available Commands
Command Settings
![Page 28: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/28.jpg)
Testing Solar Cells with SMU(N6784A)+20V
+1A
+3A-3A
+6V-6V
-1A
- 20V
Working Range
PV Cell
Up to 4 channel SMU with ±20V in one mainframe(N6705B)
4-quadrant operation
High current sensitivity of 100pA with 16 bit resolution
Can measure from 100nA to 3A at up to 200k samples/s
High load capacitance up to 150uF
N6705B N6784A
![Page 29: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/29.jpg)
Testing Solar Cells with SMU(B2900A)
Range of up to 210 V and 3 A (DC)/10.5 A (pulsed) provides wider
coverage for testing a variety of devices
Measurement resolution of 10 fA and 100 nV offers better source
and measurement performance
Quick bench-top testing, debug and characterization
PV Cell
20V
-20V
3A-3A
Working Range
![Page 30: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/30.jpg)
Testing Solar Cells with SMU(B2900A)
Dual View:
See all set and meas
ure values with all di
gits displayed
Roll View:
Display data
in time domain
as a strip chart
Graph View:
Characterize IV
curves on the fr
ont panel
Single View:
Set IV sweep pa
rameters
interactively
![Page 31: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/31.jpg)
Testing Solar Cells with SMU(B2900A)
Agilent B2900A Quick IV measurement software is furnished for free!
You can easily make measurements without writing a program
Spread SheetGraph
Setting
![Page 32: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/32.jpg)
Testing Solar Cells with SMU(B1505A)
PV Cell PV Module
Four-quadrant
From 10fA/2uV
Up to 40A/3,000V
I-V, C-V
GPIB port
Prober control
C-Vdc
C-f
HCSMU
40V
20A
40A (2xHCSMU)
HVSMU
3000V
8mA
![Page 33: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/33.jpg)
Advanced Test Environment for Solar Cell Evaluation
Measurement solution example for
parallel measurement and
control of other instruments/equipment
![Page 34: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/34.jpg)
EasyEXPERT Solar Cell Application Tests
![Page 35: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/35.jpg)
Solar Cell Test Example
C-AC Voltage Plot
Drive-level Capacitance
Profile (DLCP)
I-V forward
![Page 36: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/36.jpg)
Solar Panel Test Requirement
Switching
Temperature measure
KS C IEC 60891
![Page 37: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/37.jpg)
Temperature Measurement and switching with 34970A
Three-slot mainframe with a built-in 6½ digit digital multimeter
Each channel can be configured independently to measure one of 11 diff
erent functions without the added cost or hassles of signal-conditioning
accessories
Eight optional plug-in modules to create a compact data logger, full-featu
red data acquisition system or low-cost switching unit
34970A
data acquisition switch unit
![Page 38: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/38.jpg)
Temperature Measurement and switching with 34980A
34980A multifunction switch/measurement unit
Eight-slot mainframe
Includes an optional built-in 6½ digit DMM.
21 optional plug-in modules available
• Various switch matrices
• MUXs
• General-purpose configured switching modules34980A
Up to 560 2-wire multiplexer channels or 4096 matrix cross-points in one mainframe
Switch current carrying capabilities up to 8 A
Built-in Ethernet, USB 2.0, and GPIB connectivity, standard connectors, and software
drivers for most common programming environments
Lower cost than a comparably configured PXI-based switching solution
Optional built-in 6½ digit DMM lets you make measurements at greater than 3000 rea
dings/second
Switch relay counters help predict end of switch life
Temperature measurement capabilities with thermocouples, RTDs, or thermistors
34980A features that make it a good fit for solar cell test systems:
![Page 39: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/39.jpg)
PS-X10-100Solar Cell I-V Test System
TUV Taiwan used
Quickly characterize a solar panel
• Capture an I-V curve 100 points in 10 ms
• Up to 30 A
• Monitor Reference junction 0.1 nA resolution
• Monitor temperature
![Page 40: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/40.jpg)
Inverter
Power company
LoadsSolar Panel
Element of Solar System example
DC AC
Grid-connected system
Inverter test
![Page 41: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/41.jpg)
MPPT Distributed Maximum Power Point Tracking
Traditional system Micro Inverter Power Optimizer(DC to DC)
Inverter system Type
House AC
Internet
VAC
VAC
VAC
VDC
VDC
VDC
House AC
Internet
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
House AC
Inverter InverterMPPT MPPT
Power optimizer
MPPT
Micro Inverter
MPPT
MPPT
MPPTMPPT
MPPT
![Page 42: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/42.jpg)
What need to test for inverter?
Inverter MUST Track Maximum
power point for maximizing power
However
Panel condition should be changed by
- Irradiation level
- Temperature
- Angle of Incidence
No bypass diodes
Module Voltage
Mo
du
le C
urr
en
t
No Shadow
Photovoltaic I V Characteristics
Increasing Rs
I
V
Rs
Rsh
Decreasing RshDecreasing
Light IntensityIncreasing
Temperature
![Page 43: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/43.jpg)
E4360A Solar Array Simulator
Features that make the E4360A Solar Array Simulator ideal for inverter test:
Remote sensing – reproduce I-V curve right at the desired location
3 ways to define I-V curve – meet a variety of needs
Parameter - tests such as compliance standards at minimum, nominal, and
maximum rated voltage
Table – simulate almost any I-V curve such as shadow on individual solar cells
Offset – easily simulate changes in temperature or illumination
List mode – up to 512 parameter based curves (list steps) can be paced with dwell
times
Accurate I-V curve reproduction – test Maximum Peak Power Tracking circuitry and
algorithms
Data Logging – simultaneous V & I measurements allow for power calculation to
confirm proper simulation
E4360A Solar Array Simulator 2 outputs in 2U
510W or 600W per output
65V, 8.5A or 130V, 5A standard outputs
Series or Parallel operation for more V or IE4360A
![Page 44: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/44.jpg)
Summary
Unlit I-V Characterization < 1A
• U2722A/U2723A
•B1500A Precision Characterization
Unlit I-V Characterization < 1A
• U2722A/U2723A
• B1500A Precision Characterization
Lit I-V Characterization 3A – 6A
• B1505A Precision Characterization
• 2–6631Bs anti-series connection
• Load and PS
Lit I-V Characterization >6A
• Loads and PS
• B1505A Precision Characterization
PV Cell PV Module Temperature
Temperature
• 34970A
• 34980A
Mux
• 34970A
• 34980A
Inverter
Inverter Input test
• E4360A
Solar array simulator
Power component test
• B1505A
Precision Characterization
![Page 45: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/45.jpg)
![Page 46: Talk IT_ Agilent_최석근_110818](https://reader034.vdocuments.mx/reader034/viewer/2022052618/54baca704a79598b6e8b4589/html5/thumbnails/46.jpg)