Balancing ValvesCLIMA

747 Fixed Orifice Balancing Valve

787 Variable Orifice Balancing Valve

788 Actuated Balancing Valve

Heat Source

Additional Heat

Source

Additional Heat

Source

Primary Loop

Optimize your system's performance with Cimberio's balancing valves. Suitable for both heating and cooling systems, Cimberio's balancing valves are designed to provide accurate flow balancing for all units throughout the system ensuring consistant tempera-tures and reducing energy consumption.

All Cimberio balancing valves are manufactured to ISO 9001 and feature a compact design with integrated measuring nipples and corrosion-resistant brass bodies.

Applications include fan coils, VAV, branch lines, pumps, heating or cooling systems, multiple boiler arrangements, radiant lines, and terminal vents.

High-accuracy flow balancing across all valve settings•

Fixed orifice design for high-accuracy flow measure-•ments to within ± 5%

Metal to metal locking mechanism "remembers" valve •setting, enabling the valve to be closed and re-opened to its exact pre-set position eliminating the need for rebalancing after servicing

Heat and impact resistant handle with a 360• ° re-setta-ble indicator scale that can be read from any angle

EPDM lined valve plug for increased control •and tight shut-off for isolation purposes

Operating Pressure: 232 PSI•

Operating Temperature: 14• ° F – 248° F

Available sizes: • ½" – 2"

One-piece construction includes balance regulating •valve and measuring nipples

Thread locking mechanism "remembers" valve set-•tings, enabling the valve to be closed and re-opened to its exact pre-set position eliminating the need for rebalancing after servicing

Heat and impact resistant handle with a 360• ° re-setta-ble indicator scale that can be read from any angle

EPDM lined valve plug for increased control and tight •shut-off for isolation purposes

Operating Pressure: 350 PSI•

Operating Temperature: 14• ° F – 212° F

Available sizes: • ½" – 2"

Pre-set balancing valve with thermoelectric actuator •for opening and closing valves on heating circuit dis-tributors on floor heating systems

EPDM lined valve plug for increased control and tight •shut-off for isolation purposes

Easy, snap-on actuator installation•

Compact size•

Low power consumption•

Adaptation check on valve•

360• ˚ actuator position

Over voltage protection•

Cim788PRO is self-calibrating with first-open func-•tion, closing point detection, and proportional actuat-ing travel

Operating Pressure: 350 PSI•

Operating Temperature: 14• ° F – 212° F

Maximum Closing Pressure: 30 PSIG (70 ft. of head)•

Available sizes: • ½" – 1"

Phone: 877.228.9246 • Fax: 877.232.9246 • www.cimberiovalve.com

Utility UnionsCLIMA

790 Automatic Balancing Valve

795 Automatic Balancing Valve with Integral Actuated Control Valve

722 Configurable Utility Union

Specially designed, removable car-•tridge makes it difficult for debris to accumulate and debris won't compro-mise valve accuracy

Removable cartridge provides con-•stant flow to a pre-set rate

Cartridge is easily removed for quick •change-out, inspection, and cleaning

System remains balanced even under •fluctuating pressure

Compact installation•

Rubber diaphragm reduces water •hammer

Accurate to within • ± 5% of specified flow rate

Operating Pressure: 300 PSI•

Operating Temperature: -4• ° F – 248° F

Available sizes: • ½" – 2"

Combines Automatic Balancing Valve and ATC Control •Valve in to one compact device

Constant flow regulated by a pre-set cartridge which •can be easily removed and cleaned or replaced

Patented "Knife-Blade" cartridge design doesn't com-•promise valve accuracy even in the dirtiest applications

Cartridges available for 0.11 GPM to 10.78 GPM•

Compact, one-piece construction•

Brass alloy construction that complies with EN •12165-CW602N-M

Thermoelectric actuator for opening and closing as •called for by the thermostat or building management system

Available in three models: •NO, NC, or PROportional (0-10)

Operating Pressure: 350 PSI•

Maximum Operating Temperature: 212• ° F

Available Sizes: • ½" – 1"

FNPT x MNPT connections•

Brass alloy construction that complies with EN 12165-CW602N-M•

Operating Pressure: 290 PSI•

Maximum Operating Temperature: 212• ˚ F

Available Sizes: • ½" to 1"

Specifically designed for use with HVAC systems to provide a service point and metering station where equipment can be connected/disconnected as required. It is equipped with two configurable ports for flow management and draining or manually bleeding air from the system.

Hydronic KitsCLIMA

The CimFC1 Basic Kit includes two manual isolation valves and two flexible hoses. Options are shown below. To order, simply provide a product code for each item from the chart below.

FC1- - - - - - -

Size

_______

04 ½"

06 ¾"

07 1"

Connection

________

NPT NPT

CC SWT

PRS Press

Hose 1

________

N None

12 12"

18 18"

24 24"

CST Custom

Hose 2

________

N None

12 12"

18 18"

24 24"

CST Custom

Valve 1

______________

11 Ball Valve

200MB Ball Valve w/Dual Side Test Ports

630 Ball Valve w/Integral Strainer and Drain Valve

630B Ball Valve w/Integral Strainer,

Test Port, and Drain Valve

Valve 2

______________

11 Ball Valve

200MB Ball Valve w/Dual Side Test Ports

OptionalBypass Valve

______________

731 Bypass Valve

orAccessory

______________

722 Utility Union

Hose 1

Hose 2

Valve 1

Valve 2

Fan

Coil

Valve 1Hose 1

Valve 2Hose 2 Connection

Connection

FC1 Basic Kit for Hydronic Assembly

Cimberio's Hydronic Kits are built according to your system's needs. Choose a Basic Kit for simple manual on/off isolation, a Balanced Kit for more options tuned to the needs of your system, or an Automated Kit for those applications where balancing and interfacing with a building management system are needed. Each kit contains several options including valve and strainer options, hose sizes and lengths, and end connections.

Build your Hydronic Kit according to the needs of your system.

Step 1 Choose between a basic (FC1), balanced (FC2), or automated (FC3) kit depending on the level of efficiency your system requires.

-Basic Kit includes 2 manual isolation valves and 2 hoses. Choose this kit for single coil applications or those hook-ups that require simple manual isolation.

-Balanced Kit includes manual isolation valve, balancing valve, and 2 hoses. Choose this kit for multiple coil applications where system balancing is required.

-Automated Kit includes isolationvalve, balancing valve, zone valve option, and 2 hoses. Choose this kit for applications that require system balancing as well as an interface with a building management system.

Step 2 Choose the size you need: ½", ¾", or 1".

Step 3 Choose your connection type: NPT, sweat, or press.

Step 4 Choose your valves. Each kit comes with at least two valves (the automated kit includes an option for a third valve). There are eight different valves to choose from. All Cimberio valves are manufactured to the highest quality set by ISO 9001 standards.

Step 5 Choose your hose length: 12", 18", 24", and custom hose lengths are available or optional.

All kits are shipped fully assembled and ready for hook-up.

Example: FC1-04-CC-11-200MB-12-12 (This would be a ½" kit with SWT connections that includes a Cim11 upstream isolation ball valve, Cim200MB downstream isolation ball valve with dual side drain taps, and two 12" long hoses.)

Phone: 877.228.9246 • Fax: 877.232.9246 • www.cimberiovalve.com

The CimFC2 Balanced Kit includes manual isolation valve, manual balancing valve, and two flexible hoses. Options are shown below. To order, simply provide a product code for each item from the chart below.

The CimFC3 Automated Kit includes a manual or isolation valves, manual or automated balancing valves and two flexible hoses. Options are shown below. To order, simply provide a product code for each item from the chart below.

FC2- - - - - - -

FC3- - - - - - -

Size

_______

04 ½"

06 ¾"

07 1"

Size

_______

04 ½"

06 ¾"

07 1"

Connection

________

NPT NPT

CC SWT

PRS Press

Connection

________

NPT NPT

CC SWT

PRS Press

Hose 1

________

N None

12 12"

18 18"

24 24"

CST Custom

Hose 1

________

N None

12 12"

18 18"

24 24"

CST Custom

Hose 2

________

N None

12 12"

18 18"

24 24"

CST Custom

Hose 2

________

N None

12 12"

18 18"

24 24"

CST Custom

Valve 1

______________

11 Ball Valve

200MB Ball Valve w/Dual Side Test Ports

630 Ball Valve w/Integral Strainer and Drain Valve

630B Ball Valve w/Integral Strainer,

Test Port, and Drain Valve

Valve 1

______________

11 Ball Valve

200MB Ball Valve w/Dual Side Test Ports

630 Ball Valve w/Integral Strainer and Drain Valve

630B Ball Valve w/Integral Strainer,

Test Port, and Drain Valve

Valve 2

______________

787 Balancing Valve w/Variable

Orifice

747 Balancing Valve w/Fixed Orifice

OptionalBypass Valve

______________

731 Bypass Valve

OptionalBypass Valve

______________

731 Bypass Valve

orAccessory

______________

722 Utility Union

orAccessory

______________

722 Utility Union

Valve 1 ConnectionHose 1

Valve 2 ConnectionHose 2

Hose 1

Valve 2Hose 2

Valve 1

FC2 Balanced Kit for Hydronic Assembly

FC3 Automated Kit for Hydronic Assembly

Valve 2

______________

790 Automatic Balancing Valve

747 Balancing Valve w/Fixed Orifice

788 Actuated Balancing Valve

795 Automatic Balancing Valve

Example: FC2-06-PRS-630-787-12-12 (This would be a ¾" kit with press connections that includes a Cim630 ball valve with integral strainer, Cim787 variable orifice balancing valve, and two 12" long hoses.

Example: FC3-07-NPT-630B-788-12-12 This would be a 1" kit with NPT connections that includes a Cim630B ball valve with integral strainer, Cim788 actuated balancing valve, and two 12" long hoses.

Hose 1

Hose 2

Valve 1

Valve 2

Fan

Coil

Hose 1

Hose 2

Fan

Coil Valve 2

Valve 1

Valve OptionsCLIMA

11 Heavy Pattern Ball Valve

787 Variable Orifice Balancing Valve

722 Configurable Utility Union

200MB Ball Valve with Drain Tap and Test Ports

747 Fixed Orifice Balancing Valve

630B Ball Valve with Strainer, Drain Valve, and Test Port

790 Automatic Balancing Valve

788 Actuated Balancing Valve

795 Automatic Balancing Valve with integral Actuated Control Valve

Blast/Impact proof stem•

Corrosion-resistant •coated handle

Slow closure, locking, •and tee handle options also available

Includes measuring nipples•

Integral memory stop eliminates •rebalancing after service

Heat and impact resistant handle •can be read from any angle

EPDM lined valve plug provides •increased control and tight shut-off for isolation purposes

Fixed orifice design allows high •accuracy flow measurement to within ± 5% regardless of valve setting

Includes measuring nipples•

Provides constant flow to a pre-set rate •through the use of a removable cartridge

Specifically designed cartridge makes it dif-•ficult for dirt and debris to accumulate and debris won't compromise valve accuracy

Cartridge can be easily removed for quick •change-out, inspection, and cleaning

Accurate to within • ± 5% of specified flow rate

Pre-set balancing valve with ther-•moelectric actuator for opening and closing valves

Variable orifice control element•

EPDM lined valve plug provides •increased control and tight shut-off for isolation purposes

Blast/Impact proof stem•

Slow closure, locking, and tee •handle options also available

Corrosion-resistant coated handle•

Features a tap drain on both •sides of the valve body

FNPT x MNPT Connections•

Optional manual air vents, drain test •ports, or plug

Brass alloy construction complies •with EN12165-CW602N-M

Blast/Impact proof stem•

Removable strainer collects impurities •and protects delicate components

Includes test port and drain valve •with garden hose connection and cap and chain

Includes measuring nipples•

Integral memory stop eliminates •rebalancing after service

Heat and impact resistant handle •can be read from any angle

EPDM lined valve plug provides •increased control and tight shut-off for isolation purposes

Combines Automatic Balancing Valve and •ATC Control Valve in to one compact device

Constant flow regulated by a pre-set car-•tridge which can be easily removed and cleaned or replaced

Patented “Knife-Blade” cartridge design •doesn’t compromise valve accuracy even in the dirtiest applications

Combines all of the components required for flushing and •commissioning the system into a single assembly

Includes isolation valve with integral strainer, drain port, integral •bypass valve, and a manual or automatic balancing valve

Strainer can be cleaned and serviced without shutting down •the entire system

Requires only four connections•

Union joints allow whole assembly to be adjusted on site for •maximum convenience and easy accessibility

Integrated design eliminates leak points and saves time and •money on installation and maintenance

Easy to install with velcro strap for fast connection•

Polyethylene foam construction provides excellent insulation•

Prevents valve tampering•

Light and flexible material•

Eliminates condensation•

Replacements available•

MonolinkCLIMA

733.1 Monolink Fan Coil Valve Connection Unit

723.1 Binder Points

728.1 Insulating Boxes

Cim 733/747

Cim 733/787

Cim 733/788NC

Extended Handle

Test Point to Measure Terminal Unit Pressure Drop

Test Points for Valve Commissioning

Bypass ValveIsolation Valve

Integral Strainer

Drain Valve

Air Vent Valve

Integral O-Ring Style Union

Balancing Valve

Cimberio's Monolink is an innovative and compact valve assembly that combines the components required for flushing and commis-sioning an HVAC system into a single unit. The Monolink comibines an isolation valve with integral strainer, drain port, a built-in special bypass valve, and a manual or automated balancing valve. Thanks to the isolation valve fitted on the flow side, it is possible to clean and service the strainer without having to drain down the whole system. Only four connections are required and, because the connections are simple union joints, the whole assembly can be adjusted on site for maximum convenience and easy accessibility, even in limited space.

Phone: 877.228.9246 • Fax: 877.232.9246 • www.cimberiovalve.com

Phone: 877.228.9246 • Fax: 877.232.9246 • www.cimberiovalve.com

CLIMA AC6

Commissioning UnitElectronic commissioning to a new levelNow with unique “DSP technology” for sensor protection

Cimdronic AC6 is a state of the art electronic commissioning meter for measure-ment of differential pressures and flow-rates of water in HVAC systems. A wide range of features coupled with a database of over 2500 valves, from 49 world manufactur-ers, make the Cimdronic AC6 the first choice meter for commissioning engineers.SimplicityNine buttons designed for simple navigation allow quick and efficient use of the menu system. The Cimdronic AC6 is arranged with a choice of screen displays, whether it be the full parameter, showing all the data available or simply a screen showing in large text just the differential pressure, the user has the option to select the most appropriate screen for the work being carried out.ConvenienceCompactness and light weight enable the user to operate effectively without the inconvenience of bulky equipment. Backlit display, anti-kink pipes, snap connectors and approximately 20 hours use from readily available standard alkaline PP3 batter-ies. The Cimdronic AC6 is supplied in a convenient carry case.AccuracyThe Cimdronic AC6 uses a sensor calibrated to 20 points and protected by “DSP technology” allowing the use of sensors most appropriate for the measurement ranges experienced in HVAC and not compromised by the need for sensors select-ed for high over-pressure with their poor accuracy and resolution at low dp readings. Accuracy is better than 1% or 100 Pascals with system damping to further improve reading confidence on unstable systems.

Measurement AccuracyDifferential pressure: better than 100 Pascals or 1% whichever is the greatest.Measurement Range0.1 kPa to 250 kPa 0 to 95 deg cEffective Operating Time20 hours with standard Alkaline PP3 battery.User InterfaceSoftware for the Cimdronic AC6 has been designed around simple text files which are supplied on CD-ROM. Users wish-ing to edit the files can simply remove the MMC card from the Cimdronic AC6 and make the desired changes using a suitable read/write device and text editor. Typically, users might wish to add valves or devices not held on the database or, modify the list of valves displayed on the Cimdronic AC6 to allow quicker ac-cess to preferred valves.Database1300 valves and measuring devices from 34 manufacturers.ExtrasTool belt for hands-free portability. Replacement hoses up to 3 metres in length. Mechseal style and insertion test points.

FunctionsDisplaysMain display: shows valve type, Kvs value, hand-wheel setting (Variable orifice), Design flow, target Flow, Differential pressure, Flow, valve maker, valve type, valve size.Pressure display: large text Differential pressure.Flow Display: Large text flow.Predictive hand-wheel position: For adjusting variable orifice valves.Chart recorder: Sample system characteristic.Fast valve: Up to eight valves with model, size and design flow attributes can be saved to a quick access location for fast recall when balancing systems with multiple valve types/sites.Help: Context sensitive help is available for all functions. Dedi-cated button available for this functionUnitsDifferential pressure: Pa, kPa, psi, bar, feet H20, Inches H20, rntrs H20, mm H20, cm H20.Flow: I/s, I/m, I/h, galls/m (imperial), gpm (US).Temperature: Celsius, Fahrenheit.Edit FunctionsDesign flow, target flow, specific gravity, Kvs, valve maker, valve group, valve model. valve size, hand-wheel position. Zero cutoff.

Coming Soon