table of contents - rotarexrotarex.com/alpi-line/docs/med_044_catalogue_valves_v13_e.pdf · table...

36
MEDICAL CYLINDER VALVES

Upload: hakien

Post on 01-Jan-2019

227 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

MEDICAL CYLINDER VALVES

Page 2: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec
Page 3: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

13485QUALITYASSURANCE

ISO0029

TABLE OF CONTENTS

3

INTRODUCTION P.004

- Ceodeux meditec solutions P.004

- Quality first... P.004

- The main medical gases P.005

- Product range overview P.006

- Technology overview P.008

- How to select valves P.012

VALVES INTEGRATED WITH PRESSURE REGULATOR P.014

- M707 – Lifeball P.014

- M706/M713 | LIFE+ P.016

- M741 | LIFE-s P.018

- M800 – Emergency Back Pack P.020

- Protective Guard P.021

CYLINDER VALVE WITH RESIDUAL PRESSURE VALVE P.020

- M510/M515/M501/M506/M520/M525 Standard RPV Cylinder Valve P.022

- M540/M545/M530/M535 | Standard RPV off line P.023

- M511/M516/M508/M521/M526 | Standard RPV in line P.024

- M978/M979/C878 | Standard RPV in line P.025

- M100/M105/M040/M045/M200/M205 | Standard cylinder valve P.026

STANDARD CYLINDER VALVE P.027

- M972/M973/M974/M975 | standard cylinder valve small cone P.027

- D113 – Packed Valve P.028

- D413 – Tied Diaphragm P.029

SPECIAL NITRIC OXIDE CYLINDER VALVE P.030

- M966 – Pin index Cylinder Valve P.030

- M650 – Pin index RPV Cylinder Valve P.031

All Rotarex regulators are produced in Europe in accordance with international standards (ISO; CGA....) and are guaran-teed to provide safe and reliable performance in operation. All locations are ISO 13485.

Page 4: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

CEODEUX MEDITEC SOLUTIONS

QUALITY FIRST...

4 INTRODUCTION

ALL RIGHTS OF CHANGE RESERVED

Patient therapy and safety is our main focus in the design, installation, commissioning and operation of medical gas pipeline systems

QUANTITY OF SUPPLYValves are designed in such a way sufficient medical gas capacity can be ensured in order to provide the required flows of gases for the intended number of patients to be treated at any time.

IDENTITY OF SUPPLYAll our products are designed, produced and controlled for a specific medical gas. All points to which the user or technical staff can connect are gas specified. There is no risk of misconnection.

QUALITY OF SUPPLYOur valves maintain quality of supplied medical gases thanks to appropri-ate selection of material, components cleanliness and internal filtration equipment.Products designs ensure safe supply by minimizing ignition risks, by avoid-ing patient poisoning risks and by guaranteeing very good performances for accurate therapies.

CEODEUX MEDITEC products are designed, validated, produced and con-trolled during their whole lifetime according to a very stringent quality system which exceeds requirements of ISO 13485 standard.

DESIGNAll our products comply with local and international standards. Some reference standards:

ISO 10524-3 / CGA E-18 VIPR

ISO 10297 / CGA V1 Standard Cylinder Valves

ISO 15996 RPV Valves

ISO 11117 Protection Guard

Product design is done through a risk assessment process and is combining proven technologies and innovation to reach the best performance levels.

VALIDATIONProduct validation process guarantees that products are developed and produced to withstand the complete lifecycle (installation, commission-ing, normal service and maintenance)

PRODUCTIONAll products are produced in a controlled environment in order to maintain cleanlinessAn individual traceability is ensured with individual serial numberProducts are individually controlled and data are recorded for a perfect product management.All products are cleaned according to ISO 15001

Page 5: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

THE MAIN MEDICAL GASES

5INTRODUCTION

ALL RIGHTS OF CHANGE RESERVED

Symbol Name Application Source Type

O2 OxygenOxygen is one of the most extensively used gases for respiratory therapy and life-support and is additionally used in anesthetic procedures.

- Compressed gas cylinder - Liquid tank - Concentrator

Air AirMedical air is mainly used in respiratory therapy as a power source for patient ventilators, and for blending with oxygen. It is also used as the driving gas for nebulized drugs and chemotherapy agents.

- Compressor - Compressed gas cylinder

N2O Nitrous OxideNitrous oxide is used for anesthetic and analgesic purposes, being mixed with air, oxygen, and nebulized agents.

- Liquefied gas cylinder

CO2 Carbon DioxideCarbon dioxide is used less commonly now as a respiratory stimulant, and for insufflation during surgery.

- Liquefied gas cylinder

Air Surgical AirSurgical air (of medical air quality) is also used, at a higher pressure, to power a variety of surgical tools and other devices such as tourniquets.

- Compressor - Compressed gas cylinder

N2 NitrogenAs an alternative, nitrogen can be used for the same purpose as surgical air.

- Compressed gas cylinder

Page 6: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

STANDARD CYLINDER VALVE WITH RESIDUAL PRESSURE VALVE OFF LINE

M510/M515 P. 22 M501/M506 P. 22 M520/M525 P. 22 M540/M545 P.23 M530/M535 P. 23

Gas type O2 CO2 Various gases O2 Various gases

Material Chrome plated brass Chrome plated brass Chrome plated brass Chrome plated brass Chrome plated brass

Inlet pressure 200 bar/2900 psi 200 bar/2900 psi 200 bar/2900 psi 300 bar/4350 psi 300 bar/4350 psi

STANDARD CYLINDER VALVE WITH RESIDUAL PRESSURE VALVE IN LINE

M511/M516 P. 24 M508 P. 24 M521/M526 P. 24 M978/M979 P. 25

SMALL CONEC878 P. 25

INTEGRATED GAUGEGas type O2 CO2 Various gases O2, various gases o

Material Chrome plated brass Chrome plated brass Chrome plated brass Chrome plated brass Chrome plated brass

Inlet pressure 200 bar/2900 psi 200 bar/2900 psi 200 bar/2900 psi 200 bar/2900 psi 200 bar/2900 psi

6

VIPR

LIFEBALL P. 14 LIFE + P. 16 LIFE-s P. 18

Gas type O2 O2 O2

Material Chrome plated brass Chrome plated brass Chrome plated brass

Inlet pressure 200 bar/300 bar

2000 psi/3000 psi

M706: 200 bar/2900 psi

M709: 300 bar/4350 psi

200 bar/2900 psi

M800 EMERGENCY OXYGEN BACK PACK P. 20 M706/M713 PROTECTIVE GUARD P. 21

Gas type O2 Ø

Material Chrome plated brass Plastic PA6.6

Inlet pressure 200 bar/2900 psi Ø

PRODUCT RANGE OVERVIEW

INTRODUCTION

Page 7: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

PIN INDEX VALVE

M966 PIN INDEX CYLINDER VALVE P. 30 M650 P. 31

PIN INDEX RPV CYLINDER VALVE

Gas type O2 O2

Material Chrome plated brass Chrome plated or natural brass

Inlet pressure 232 bar/3364 psi 232 bar/3364 psi

SPECIAL NITRIC OXIDE MIXTURES CYLINDER VALVE

D113 PACKED VALVE P. 28 D413 TIED DIAPHRAGM P. 29

Gas type No No

Material Stainless steel Stainless steel

Inlet pressure 200 bar/2900 psi 200 bar/2900 psi

7

PRODUCT RANGE OVERVIEW

INTRODUCTION

STANDARD CYLINDER VALVE

M100/M105 P. 26 C040/C045 P. 26 M200/M205 P. 26 M972/M973 P. 27

SMALL CONEM974/M975 P. 27

SMALL CONEGas type O2 CO2 Various gases O2 Various gases

Material Chrome plated brass Chrome plated brass Chrome plated brass Chrome plated brass Chrome plated brass

Inlet pressure 200 bar / 2900 psi 200 bar / 2900 psi 200 bar / 2900 psi 200 bar/2900 psi 200 bar/2900 psi

Page 8: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

TECHNOLOGY OVERVIEW

INTRODUCTION8

Ceodeux Meditec uses 4 main technologies to achieve a proper and reliable gas use from the cylinder:

VIPR - Valve with integrated pressure regulator Design to save your time: Easy and Ready to use medical valve with in-built regulator, flow meter, contains gauge and outlet pressure connector.

- Compact and lightweight : ideal for small cylinder - Fully protected by an ergonomic plastic guard - Filtration system ensures safety against ignition. - Flow meter with orifice plate precision design increase high flow precision and low flow precision for pediatric patients

RESIDUAL PRESSURE VALVE - Open/close fonctionnalities - Improved safety thanks to RPV technology included (avoid all contamination risks)

- Safe, long, trouble free life under all service conditions - Exist in offset and inline version

STANDARD CYLINDER VALVE - Standard open/close fonctionnalities - High life cycle thanks to smart choice of materials - Safe, long, trouble free life under all service conditions

PIN INDEX VALVE - Standard open/close fonctionnalities - Yoke outlet connection (PIN INDEX System) - Key operated or handwheel manipulation - High life cycle thanks to smart choice of materials - Safe, long, trouble free life under all service conditions

CEODEUX MEDITEC VIPR

M707 P. 014

M706 P. 016

M713 P. 016

M741 P. 018

M800 P. 020

PRODUCT FINDER

CEODEUX MEDITEC RPV valve

M510/M515/M501/M506/M520/M525/M540/M545M530/M535/ M511/M516/M508/M521/M526 P. 024

M978/M979/C878 P. 025

PRODUCT FINDER

CEODEUX MEDITEC Standard valve

M100/M105/M040/M045/M200/M205/ M972/M973/M974/M975 P. 026

D113 P. 028

D413 P. 029

PRODUCT FINDER

CEODEUX MEDITEC Pin Index valve

M966 P. 030

M650 P. 031

PRODUCT FINDER

Page 9: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

TECHNOLOGY OVERVIEW

9INTRODUCTION

VALVE INLET - Anti dust tube according to the last amendment of EN ISO 10524-3

· Better protection of the valve against contamination and eliminates the risk of ignition in case accumulation of particles in a filter

- Excess flow device · Additional safety to avoid excess flow risks and optimize normal flow in use

FILLING PORT - Approved for 300 bar (tested at 360 bar) - Active and non-active - Spring in Copper Beryllium material highly compatible with oxidizing gases

- O-rings in EPDM - High leak integrity due to seat O-ring and 2-parts design, including degasing hole

- High performance of the filling port against ignition with protruding pin design

- Filling port fully integrated in the valve body - Endurance performance is twice the requirment of the ISO standard (2000 cycles)

PRESSURE GAUGE - NEW Electronic system available (please refer to page 9 for further informations)

- Design fully in accordance with the EN ISO 10524-3 including a flow restrictor to prevent part ejection in case of failure

- Direct drive technology used for the Bourdon tube to reduce consequences of vibration or shocks

- Gauge display tight to water contamination - Safety Relief valve with 3 holes on the glass and tightness evidence sticker - Active pressure gauge for permanent content visibility

OUTLET PRESSURE: MEDICAL CONNECTOR - Same outlet as wall outlet used in hospitals with design according national standard

- Make connection to medical equipment possible to transport patients - Minimum outlet pressure guaranteed when high flow is required by downstream equipment

SHUT-OFF VALVE - 5000 cycles according CGA V9 (under 360 Bar) - None rotating lower spindle to avoid particles generation - Very low torque design to operate the shut-off valve up to 300 bar - ISO 10297

DETAILED FUNCTIONNALITIES OF OUR INTEGRATED VALVES

Page 10: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

REGULATOR SAFETY RELIEF DEVICE - Integrated into the regulator design

· Quicker reaction - Large contact surface to increase sensitivity and reactivity to overpressure

- No risk to damage the device - High flow through the device due to the large diameter and large venting holes

FLOWMETER AND HOSEBARB - 12 positions - Continuous flow even in between setting positions during handwheel operation

- No possible positioning of the handwheel in-between settings - High precision of the flows - 10 year life time without maintenance - Easy replacement of the handwheel - High leak integrity performance - Flow range: Pediatric applications 0 -> 2 LpmHomecare 0 -> 6 LpmHospital 0 -> 15/ 0 -> 25 Lpm Possibility to be customed

PRESSURE REGULATOR - Piston-type regulator - Improved safety and reliability - Direct acting valve (decrease pressure curve) according to ISO 10524-3 and CGA-18

- High compatible materials with Oxygen and Medical applications

RESIDUAL PRESSURE VALVE - Protection of the cylinder against external contamination - High endurance performance in terms of leak integrity and functionality

· According standard ISO15996 – 100.000 cycles · Specific seat design to protect sealing O-ring during operation

- 3 bar residual pressure guaranteed at maximum flow setting

TECHNOLOGY OVERVIEW

DETAILED FUNCTIONNALITIES OF OUR INTEGRATED VALVES

10 INTRODUCTION

ALL RIGHTS OF CHANGE RESERVED

Page 11: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

GROUNDBREAKING INNOVATION TO PERFECTLY REACH OXYGEN THERAPY REQUIREMENTS:

• Reactivity : Quick and accurate calculation of remaining time • Safety : Perfectly suitable for high pressure pure Oxygen environnement• Patient & Medical staff Services : Improved cylinders fl eet management.

- Quicker operations in emergency situations - Bluetooth for wireless communication

• Optimization : Longer cylinder use thanks to accurate cylinder content management

TECHNOLOGY OVERVIEW

11INTRODUCTION

CEODEUX MEDITEC INTELLIGENT ELECTRONIC SYSTEM CHANGE THE WAY YOU USE GAS

ALL RIGHTS OF CHANGE RESERVED

Get in touch with excellence

NEW CONTROL GAS USE THANKS TO INFORMATION TRANSPARENCY

NEW GAS THERAPY OPTIMIZATION THANKS TO ANTICIPATION

COLOR CODED CYLINDER CONTENT LEVEL INDICATIONS2

1 CYLINDER CONTENT BAR GRAPH (%)

3 PRECISE CYLINDER PRESSURE

5 CALCULATION SYMBOL FLOW

6 AVAILABLE WIRELESS BLUETOOTH COMMUNICATION

4 REMAINING TIME FOR USE AT SELECTED FLOW RATE

2

1

3

45

Cylinder content* bar graph (%). Visual indications of real quantity of gas into cylinder whatever pressure and temperature parameters are.

Red: Warning area : < 10% cylinder content Yellow : Pre-Warning area : 10% < cylinder content < 30% Green : Confortable area : >30% cylinder content

Precise cylinder pressure Cylinder pressure measure-ment at real conditions Bar – Psi - kPa units available.

At changing conditions calculation process before displaying remaining time.

Remaining time for use at selected fl ow. Accurate and quick calculation of the remaining time according to fl ow selection and cylinder content. Precise displayed unit: hh:mm

Indicate when a sensor default was detected into the system

Indicate when an electronic failure was detectead into the system

Indicate when battery level of the system doesn’t guarantee anymore the accurate func-tionning of the valve

Indicate when environment is not conformed with valve functioning (e.g. high or low temperature)

Indicate when gas fl ow is critical (Less of 10 minutes of use or 10 bar remain-ing in the cylinder)

* Quantity of gas into the cylinder

6

Intelligent and complete alarm system to clearly indicate when user face a critical situation. Audible and visible alerts for enhanced patient safety

SYSTEMS FAILURES NORMAL USE ALARMS

Page 12: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

HOW TO SELECT VALVES

BODY MATERIALS

Most Ceodeux Meditec valves are available in brass or chrome plated brass.

Chrome plated or Raw brass: The most commonly used material for high velocity oxygen applications due to its cost effectiveness, good strength, resistence and low-friction flow properties.

Need more information? One of our material engineers would be happy to discuss the pros and cons of each option to help you choose the best solution.

INLET PRESSURE

OUTLET PRESSURE

Different models are designed for different inlet pressure to fit with your applications need (working pressure). For high pressure (200bar/3000psi) the Ceodeux Meditec valves range covers any requirements.

The available options are clearly indicated on each product page.Please specify required inlet pressures when ordering. We can also accommodate special requests.

Especially for VIPR: different models are designed for different outlet pres-sure to fit with your applications need (working pressure). For low pressure needed in use (4,5bar/50psi) and for accurate flow (from 0-2 to 0-25 Lpm) the Ceodeux Meditec VIPR range covers any requirements.

The available options are clearly indicated on each product page.Please specify required inlet pressures when ordering. We can also accommodate special requests.

INLET CONNECTIONS

Specific cylinder valve connections are required for each gas type. The most common connection types are ¾’’-16 UNF and 25E.Other standards and dimensions are available on request.

OUTLET CONNECTIONS

VIPR: Specific outlet connections are available (medical connector types). According to your national standards the Ceodeux Meditec valves range covers any requirements.

Specific flow outlet connections are available (hose barb) according to EN 13544-2 and supplied from flow selector.

Valves:According to your national standards and according to upstream device to be connected (pressure regulator, flex hose,...) the Ceodeux Meditec valves range covers any requirements.

Gas Compatibility: make sure the body material is compatible with the gas type you will be using.

INTRODUCTION12

Page 13: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

HOW TO SELECT VALVES

13INTRODUCTION

8 9

ALL RIGHTS OF CHANGE RESERVED ALL RIGHTS OF CHANGE RESERVED

SPECIFICATIONS

ALL FUNCTIONS IN ONE DEVICE

- Active Pressure Measurement - High Pressure Shut Off Valve - Filling Port with Check Valve - Residual Pressure Valve - Pressure Regulator - Safety Relief Device - Flow Selector - Medical Outlet Connection (Optional)

REGULATORY

- Medical CE certifi ed according to MDD 93/42/EEC amended 2007/47/EC

- π certifi ed according TPED Directive 2010/35/EU - Product complies with EN ISO 10524-3 and CGA E-18

- Medical integrated valve for Oxygen and others medical gases

- For all hospital and homecare applications

- Complies with the most stringent standards and requirements

- Approved by the major medical authorities worldwide

- Available in many diff erent confi gurations

M706 | ALPINOX INTEGRATED VALVE

KEY ADVANTAGES

Inlet Connection 17E / 25E / M18 / ¼ ”- 16 UNF

Filling Port ISO 5145 / CGA V1 with check valve

Flow Outlet Hose Barb

Pressure Outlet Acc. to national standards

Inlet pressure 200 bar / 2900 psi

Temperature range

-20°C to +60°C

Outlet pressure 4.5 bar (EU)3.5 bar (USA)

Flow range 12 pos.

0-6 Lpm / 0-15 Lpm / 0-25 Lpm

Body Chrome plated brass

Seats PA 6.6

O-ring EPDM

Filters Sintered Bronze 20 μm

OPTIONS

Protection Guard CSN / MIF / CBNE with bed hanger Inlet Device Filter / Anti-dust tube / Excess Flow device

PRODUCT REFERENCES

Gas Working pressure Inlet Connection Filling port Outlet Pressure Flow Range Medical connector

M70600153 O2 200 bar 25E ISO 5145 4.5 bar 0-25 Lpm DIN 13260-2

M70600152 O2 200 bar 25E ISO 5145 4.5 bar 0-25 Lpm NFS 90-116

M70600130 O2 2000 psi ¼ ” - 16 UNF CGA 540 50 psi 0-25 Lpm DISS 1240

M70600109 O2 200 bar 17E ISO 5145 4.5 bar 0-15 Lpm None

M70600121 N2 O / O2 135 bar 25E ISO 5145 4.5 bar 0-15 Lpm NFS 90-116

Others versions and possibilities available upon request

Simple Use - Ready-to-use Design - Simple, quick and intuitive function to deliver gas - Easy access to all functions

High Performances - Proven and Reliable Single stage piston regulator - High Pressure and Flow Stability and Accuracy outstanding fl ow outlet pressure stability. Exceptionally accurate.

- Wide fl ow ranges for many applications

Safety First - No high pressure manipulation - Shut off valve to isolate high pressure if required - Preset integrated pressure relief device - Flow selector design reducing likelihood of being set between two settings

- Continuous fl ow between settings - Active pressure gauge for a permanent indication - RPV function in order to avoid any potential contamination - Choice of material ensures patient health and safety

M706 M706 with plastic guard

CYLINDER VALVES INTEGRATED WITH PRESSURE REGULATORCYLINDER VALVES INTEGRATED WITH PRESSURE REGULATOR

TECHNICAL PARAMETER

Working pressure

Outlet pressure (only for VIPR)

Gas type or medical mixture

Material: raw brass or chrome plated

Inlet connection: 17E, 25E, 3⁄14”-16 UNF

Outlet connection valve- according to standards

Filling port (only for VIPR): acc ISO 5145 or CGA V1.,...

Residual pressure: if requested or no

Gauge: if specifi c request

Temperature range: -20°C/+65°C or specifi c

Description of the fi nal application: hospital homecare, emergency, or other

Guard: select a model and confi rm type of cylinder and cylinder weight

Guard color: white or green / Other colors on request + marking

Bed hanger (only for VIPR): if required or not

Environment: if special

Product applicable standards: EN ISO 10524-3 (VIPR) EN ISO 10297, CGA E-18

Certifi cation / Approval / RegistrationCE marked - 93/42/EEC European Medical Device Directive, FDA 510(k) – USA, TGA (Therapeutic Goods Administration) - Australia, Health Canada – Singapore, ANVISA – Brasil

To choose the right valve for your application and get the best results, you should identify the following technical parameters:

Each product page is designed to provide you the essential technical information at a glance:

Page 14: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

Standard manometer available

14

ALL RIGHTS OF CHANGE RESERVED

VIPR

ALL FUNCTIONS IN ONE DEVICE

- Active Pressure Measurement - Filling Port with Check Valve - Residual Pressure Valve - Pressure Regulator - Safety Relief Device - Flow Selector - Medical Outlet Connection (Optional)

REGULATORY

- Medical CE certifi ed according to MDD 93/42/EEC amended 2007/47/EC

- π certifi ed according TPED Directive 2010/35/EU - Product complies with EN ISO 10524-3 and CGA E-18

M707 | LIFEBALL

- Ultra compact medical integrated valve for O2 and other medical gases

- For all hospital and homecare applications

- Centralized control unit on top of the value

- High legibility of fl ow settings with large and phosphorescent chraracters

- Very compact and light design

- High presicion thanks to compensated regulator

- Unique intellingent electronic system to display and manage yuour gas use (for more info please refer to page 9)

Page 15: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

1515

ALL RIGHTS OF CHANGE RESERVED

VIPR

SPECIFICATIONS

Inlet Connection 25E/17E/¾”-16UNF

Filling Port CGA 540/CGA 577/ISO W24x2/ ISO W30x2/W22x14R

Flow Outlet Hose Barb acc. to Iso 13544-2

Pressure Outlet Acc. to national standards

Inlet pressure 200 bar/2000 psi 300 bar/3000 psi

Temperature range

-20°C to +60°C

Outlet pressure 3.5 bar/43 psi 4.5 bar/58 psi

Flow range 12 pos.

0-2 Lpm / 0-6 Lpm / 0-15 Lpm

Body Chrome plated brass

Seats PA 6.6

O-ring EPDM

Filters Sintered Bronze 60 μm

MAIN FUNCTIONNALITIES

To better understand roles and benefits of each of these functions please refer to our technological review section on page 9

1 VALVE INLET

2 ANTIDUST TUBE

3 FILLING PORT

4 GAUGE

4

7

5

8

6

5 RPV

6 HOSE BARB

7 FLOWMETER

8 REGULATOR & SAFETY RELIEF DEVICE

9 BED HANGER

10 OUTLET PRESSURE: MEDICAL CONNECTOR

1

3

9

2

10

PRODUCT CONFIGURATOR

GasInlet

ConnectionWorking Pressure

Filling Port

HP SafetyOutlet

PressureFlow Range

Pressure outlet

Flow outlet Inlet optionsGuard Color

Bed Hanger

M707 O2 A 200 ISO N 3.5 2 N HB6 EFD W BH

O2 O2 17E A 200bar 200 ISO 5145

ISO None N 3.5bar 3.5 0-2Lpm 2 None N Hose Barb Ø6mm

HB6 Excess flow device

EFD White W Yes BH

Air AIR 25E B 300bar 300 CGA V1

CGA CGA S1.1

CGA 4.5bar 4.5 0-6Lpm 6 AFNOR NF Anti dust tube

ADT Green G

N2O/O2 N2O 3/4"-16 UNF

CCS 2000Psi 2000 UNI UNI JIS JIS 0-15Lpm 15 DIN DIN

3000Psi 3000 JIS JIS 0-25Lpm 25 BS BS

w14,5MPa 14.5 SS SS

JIS JIS

AS AS

DISS DISS

Page 16: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

16

ALL RIGHTS OF CHANGE RESERVED

ALL FUNCTIONS IN ONE DEVICE

- Active Pressure Measurement - High Pressure Shut Off Valve - Filling Port with Check Valve - Residual Pressure Valve - Pressure Regulator - Safety Relief Device - Flow Selector - Medical Outlet Connection (Optional)

REGULATORY

- Medical CE certifi ed according to MDD 93/42/EEC amended 2007/47/EC

- π certifi ed according TPED Directive 2010/35/EU - Product complies with EN ISO 10524-3 and CGA E-18

- Medical integrated valve for Oxygen and others medical gases

- For all hospital and homecare applications

- Complies with the most stringent standards and requirements

- Approved by the major medical authorities worldwide

- Available in many diff erent confi gurations

M706/M713 | LIFE+

Other combination available

Confi g. 1

Confi g. 2

VIPR

+

Filling PortShut Off Valve

Flow Outlet+ Pressure Gauge

MedicalOutlet

Connector

Filling Port

Shut Off Valve

Flow Outlet+ Pressure Gauge

MedicalOutlet

Connector

Page 17: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

17

ALL RIGHTS OF CHANGE RESERVED

Confi g 1

SPECIFICATIONS

Inlet Connection 17E / 25E / M18 / ¾ ”- 16 UNF

Filling Port ISO 5145 / CGA V1 with check valve

Flow Outlet Hose Barb

Pressure Outlet Acc. to national standards

Inlet pressure M706:200 bar / 2900 psiM709:300bar

Temperature range

-20°C to +60°C

Outlet pressure 4.5 bar (EU)3.5 bar (USA)

Flow range 12 pos.

0-6 Lpm / 0-15 Lpm / 0-25 Lpm

Body Chrome plated brass

Seats PA 6.6

O-ring EPDM

Filters Sintered Bronze 20 μm

OPTIONS

Protection Guard CSN2 (see main picture) / MIF (see on page 19) with bed hanger

Inlet Device Filter / Anti-dust tube / Excess Flow device

VIPR

MAIN FUNCTIONNALITIES

To better understand roles and benefi ts of each of these functions please refer to our technological review section on page 9

1 VALVE INLET

2 ANTIDUST TUBE

3 FILLING PORT

4 GAUGE

5 RPV

6 HOSE BARB

6

7 FLOWMETER

8 REGULATOR & SAFETY RELIEF DEVICE

9 SHUT OFF VALVE

10 OUTLET PRESSURE: MEDICAL CONNECTOR

4

7

5

8

1

3

9

2

10

PRODUCT CONFIGURATOR

GasInlet

ConnectionWorking Pressure

Filling Port

HP SafetyOutlet

PressureFlow Range

Pressure outlet

Flow outletInlet

optionsGuard type

Guard Color

Confi gu-ration

M706/M713 O2 A 200 ISO N 3.5 2 N HB6 EFD CSN W

O2 O2 17E A 200bar 200 ISO 5145

ISO None N 3.5bar 3.5 0-2Lpm 2 None N Hose Barb Ø6mm

HB6 Excess fl ow device

EFD CSN CSN White W Confi g 1

Air AIR 25E B 300bar 300 CGA V1

CGA CGA S1.1

CGA 4.5bar 4.5 0-6Lpm 6 AFNOR NF Anti dust tube

ADT MIF MIF Green G Confi g 2

N2O/O2

N2O 3/4"-16 UNF

CCS 2000Psi 2000 UNI UNI JIS JIS 0-15Lpm 15 DIN DIN

3000Psi 3000 JIS JIS 0-25Lpm 25 BS BS

w14,5MPa

14.5 SS SS

JIS JIS

AS AS

DISS DISS

Page 18: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

18

ALL RIGHTS OF CHANGE RESERVED

ALL FUNCTIONS IN ONE DEVICE

- Active Pressure Measurement - Cylinder Safety Device - Filling Port with Check Valve - Pressure Regulator - Safety Relief Device - Flow Selector - Medical Outlet Connection (Optional)

REGULATORY

- Product complies with CGA E-18

- Compact Medical Integrated Valve for Oxygen and others medical gases

- For all hospital and homecare applications

- For situations where performance, compactness and light weight are required

- Available in many different configurations

- Provided with a plastic integrated hanger to carry and protect the valve

M741 | LIFE-s

VIPR

Page 19: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

PRODUCT CONFIGURATOR

GasInlet

ConnectionWorking Pressure

Filling Port HP SafetyOutlet

PressureFlow Range

Pressure outlet

Flow outlet Inlet options Guard Color

M741 O2 A 200 ISO N 3.5 2 N HB6 EFD

O2 O2 17E A 200bar 200 ISO 5145 ISO None N 3.5bar 3.5 0-2Lpm 2 None N Hose Barb Ø6mm

HB6 Excess flow device

EFD White W

Air AIR 25E B 300bar 300 CGA V1 CGA CGA S1.1

CGA 4.5bar 4.5 0-6Lpm 6 AFNOR NF Anti dust tube

ADT Green G

N2O/O2 N2O 3/4"-16 UNF

CCS 2000Psi 2000 UNI UNI JIS JIS 0-15Lpm 15 DIN DIN

3000Psi 3000 JIS JIS 0-25Lpm 25 BS BS

w14,5MPa 14.5 SS SS

JIS JIS

AS AS

DISS DISS

19

ALL RIGHTS OF CHANGE RESERVED

SPECIFICATIONS

Inlet Connection ¾” - 16 UNF

Filling Port CGA 540 with check valve

Flow Outlet Hose Barb

Pressure Outlet DISS 12409/16”-18UNF

Inlet pressure 134 bar2000 psi / bar

Temperature range

-20°C to +65°C

Outlet pressure 3.5 bar/50 psi

Flow range 12 pos.

0-6 Lpm / 0-15 Lpm / 0-25 Lpm

Body Chrome plated brass

Seats PA 6.6

O-ring EPDM

Filters Sintered Bronze

OPTIONS

Inlet Device Filter / Anti-dust tube / Excess Flow device

VIPR

MAIN FUNCTIONNALITIES

To better understand roles and benefits of each of these functions please refer to our technological review section on page 9

1 VALVE INLET

2 FILLING PORT

3 GAUGE

4 HOSE BARB

5 FLOWMETER

6 REGULATOR & SAFETY RELIEF DEVICE

7 OUTLET PRESSURE: MEDICAL CONNECTOR3

7

5

1

6

2

4

Page 20: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

20

ALL RIGHTS OF CHANGE RESERVED

20

M800 | EMERGENCY BACK PACK

KIT CONTENTS

- 1 back pack: made of polyester · PVC reinforecement and inner foam construction · Large storage for additional items · Shoulder straps for hand-free intervention

- 1 cylinder · made of aluminium alloy · 2L oxygen at 200 bar

- 1 integrated valve · complies with EN ISO 10524-3 · 0-15 Lpm fl ow range · Residual pressure device · Pressure gauge 0-315 bar · Pressure-relief valve · Excess fl ow device

- 2 Nasal cannulas · Made of lightweight fl exible plastic tubing · Adult and children sizes

KEY FEATURES

- The bag is reinforced, waterproof and secures a 2 liters oxygen cylinder equipped with an integrated valve and 2 sizes of nasal cannulas.

- A complete safe contained medical oxygen breathing kit for mobile oxygen therapy

SPECIFICATIONS

Gas Medical Oxygen

Cylinder content 2L

Cylinder Pressure 200 bar/2900 psi

Flow range 0-15 Lpm

Gas Autonomy 26 min (at 15 Lpm)

Total weight 5,8 Kg

CE marking π / CE0029

VIPR

Page 21: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

21

ALL RIGHTS OF CHANGE RESERVED

21

ALL FUNCTIONS IN ONE DEVICE

- Available with an optional bed hanger for an easier handling and support

REGULATORY

- Designed and tested according to EN ISO 11117 standard

- Guards and Caps to protect the valve during service and transportation while giving the product an easy access and a good looking design

- Designed to protect all products depending on customers specifi c requirements

SPECIFICATIONS

Connection On valve body / thread W80 x 1/11”

Permitted mass Up to 60 Kg

Material PA 6.6

Temperature range

-20°C to +65°C

Dimensions Ø143 mm max.

Colors White / Black / Blue / Green

OPTIONS

Bed Hanger Assembled on the guard or cap (nif)

Label Customized labeling and/or marking

M706/M713 PROTECTIVE GUARD

MIF CSN 2

VIPR

Page 22: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

22

M510/M515/M501/M506/M520/M525 | STANDARD RPV OFF LINE

KEY FEATURES

- Low operating torque - MRI compatible - Safe, long, trouble free life under all service conditions

- Designed and tested according EN ISO 10297 and EN ISO 15996

OPTIONS

- Inlets: 17 E – 25 E – M 18 – US threads - Filter - Burst disc safety device - Thread for dip tube connection - Chrome plating

- High pressure brass cylinder valve for medical gases, O-ring seal type with residual pressure

RPV VALVE

SPECIFICATIONS

Working pressure 200 bar/ 2900 psi

Temperature range -25°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size 4 mm

Handwheel material aluminium

Seat material polyamid

O-ring material EPDM

Body material Chrome plated brass

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 200bar 200 ISO 5145 ISO None N

N2O N2O 25E B 300bar 300 CGA V1 CGA CGA S1.1 CGA

Various gases (*) VG * ¾ "-16 UNF CCS 2000Psi 2000 UNI UNI JIS JIS

CO2 CO2 ¾ " NGT OBS 3000Psi 3000 DIN DIN Eu CO2/N2O EU

AFNOR AFNOR

BS BS

SS SS

AS AS

Can be connected with Ceodeux Meditec regulators

Ref catalog: MPR-EN-1115

PRODUCT SERIE FEATURES

GAS SAFETY

O2 CO2 VARIOUS GASES WITH WITHOUT

M510

M515

M501

M506

M520

M525

* gas or mixture must be confi rmed

Page 23: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

Ref catalog: MPR-EN-1115

23

M540/M545/M530/M535 | STANDARD RPV OFF LINE

KEY FEATURES

- Low operating torque - MRI compatible - Safe, long, trouble free life under all service conditions

- Designed and tested according EN ISO 10297 and EN ISO 15996

OPTIONS

- Inlets: 17 E – 25 E – M 18 – US threads - Filter - Burst disc safety device - Thread for dip tube connection - Chrome plating

- High pressure brass cylinder valve for medical gases, O-ring seal type with residual pressure

RPV VALVE

SPECIFICATIONS

Working pressure 300 bar/ 4350 psi

Temperature range -25°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size 4 mm

handwheel material aluminium

Seat material polyamid

O-ring material EPDM

Body material Chrome plated brass

Can be connected with Ceodeux Meditec regulators

PRODUCT SERIE FEATURES

GAS SAFETY

O2 VARIOUS GASES WITH WITHOUT

M540

M545

M530

M535

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 300bar 3000 ISO 5145 ISO None N

N2O N2O 25E B CGA V1 CGA CGA S1.1 CGA

Various gases (*) VG * ¾ "-16 UNF CCS UNI UNI JIS JIS

¾ " NGT OBS DIN DIN Eu CO2/N2O EU

AFNOR AFNOR

BS BS

SS SS

AS AS

* gas or mixture must be confi rmed

Page 24: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

24

M511/M516/M508/M521/M526 | STANDARD RPV IN LINE

KEY FEATURES

- Low operating torque - MRI compatible - Safe, long, trouble free life under all service conditions

- Designed and tested according EN ISO 10297 and EN ISO 15996

OPTIONS

- Inlets: 17 E – 25 E – M 18 – US threads - Filter - Burst disc safety device - Thread for dip tube connection - Chrome plating

- High pressure brass cylinder valve for medical gases, O-ring seal type with residual pressure

RPV VALVE

SPECIFICATIONS

Working pressure 200 bar/ 2900 psi

Temperature range -25°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size 4 mm

handwheel material aluminium

Seat material polyamid

O-ring material EPDM

Body material Chrome plated brass

Can be connected with Ceodeux Meditec regulators

Ref catalog: MPR-EN-1115 PRODUCT SERIE FEATURES

GAS SAFETY

O2 CO2 VARIOUS GASES WITH WITHOUT

M511

M516

M508

M521

M526

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 200bar 200 ISO 5145 None

N2O N2O 25E B 300bar 300 CGA V1 CGA S1.1

Various gases (*) VG * ¾ "-16 UNF CCS 2000Psi 2000 UNI JIS

CO2 CO2 ¾ " NGT OBS 3000Psi 3000 JIS

* gas or mixture must be confi rmed

Page 25: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

Ref catalog: MPR-EN-1115

25

M978/M979/C878 | STANDARD RPV IN LINE

KEY FEATURES

- Low operating torque - MRI compatible - Safe, long, trouble free life under all service conditions

- Designed and tested according EN ISO 10297 and EN ISO 15996

OPTIONS

- Inlets: 17 E – 25 E – M 18 – US threads - Filter - Burst disc safety device - Thread for dip tube connection - Chrome plating

- High pressure brass cylinder valve for medical gases, O-ring seal type with residual pressure

RPV VALVE

SPECIFICATIONS

Working pressure 200 bar/ 2900 psi

Temperature range -25°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size 4 mm

handwheel material aluminium

Seat material polyamid

O-ring material EPDM

Body material Chrome plated brass

Specifi c M978: O2

M9769: various gasessC878: O2 + integrated valve

Can be connected with Ceodeux Meditec regulators

PRODUCT SERIE FEATURES

GAS SAFETY

O2 VARIOUS GASES WITH WITHOUT

M978

M979

* gas or mixture must be confi rmed

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 200bar 200 DIN DIN None N

N2O N2O M18X1,5 RCS Eu CO2/N2O EU

Various gases (*) VG *

CO2 CO2

Page 26: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

RPV VALVE26

SPECIFICATIONS

Working pressure 232 bar

Temperature range -25°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size M100/M105/M200/M205 : 4mmM040/M045: 8mm

Magnetic compatibility

yes

handwheel material polyamid

Seat material polyamid

O-ring material EPDM

Body material Chrome plated brass

KEY FEATURES

- Low operating torque - MRI compatible - Safe, long, trouble free life under all service conditions

- Approved valve design - Testing according ISO 10297 and CGA U9 Standard

OPTIONS

- Inlets: 17 E – 25 E – M 18 – US threads - Filter - Burst disc safety device - Thread for dip tube connection - Chrome plating

- High pressure brass cylinder valve for medical oxygen

- O-ring seal type

M100/M105/M040/M045/M200/M205 | STANDARD CYLINDER VALVE

Can be connected with Ceodeux Meditec regulators

Ref catalog: MPR-EN-1115

- High pressure brass cylinder valve for medical oxygen

- O-ring seal type

PRODUCT SERIE FEATURES

GAS SAFETY

O2 CO2 VARIOUS GASES WITH WITHOUT

M100

M105

M040

M045

M200

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 300bar 3000 ISO 5145 ISO None N

N2O N2O 25E B CGA V1 CGA CGA S1.1 CGA

Various gases (*) VG * ¾ "-16 UNF CCS UNI UNI JIS JIS

¾ " NGT OBS DIN DIN Eu CO2/N2O EU

AFNOR AFNOR

BS BS

SS SS

AS AS

* gas or mixture must be confi rmed

Page 27: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

M972/M973/M974/M975 | STANDARD CYLINDER VALVE SMALL CONE

SPECIFICATIONS

Working pressure 200 bar

Temperature range -20°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size 2.5 mm

Residual pressure 1-3 bar

handwheel material aluminium

Seat material PA 6.6

O-ring material EPDM

Body material Chrome plated brass

Filter material brass sintered

KEY FEATURES

- Low operating torque under up to 200 bar service pressure

- MRI compatible - Designed and tested acc. EN ISO 10297, EN ISO 15996 - Residual pressure setting 1-3 bar - Manufactured in cleanroom - Inlet with fi lter - Possibility of integrated gauge

- OPTIONS

- Inlet: 17E – M18 – M 14 - Without fi lter

Can be connected with Ceodeux Meditec regulators

Ref catalog: MPR-EN-1115

STANDARD CYLINDER VALVE 27

- High pressure brass cylinder valve for medical oxygen

- O-ring seal type

- High pressure brass cylinder valve for medical oxygen

- O-ring seal type - Small cone inlet size

PRODUCT SERIE FEATURES

GAS SAFETY

O2 VARIOUS GASES WITH WITHOUT

M972

M973

M974

M975

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 200bar 200 DIN DIN None N

N2O N2O M18X1,5 RCS Eu CO2/N2O EU

Various gases (*) VG *

CO2 CO2

* gas or mixture must be confi rmed

Page 28: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

STANDARD CYLINDER VALVE28

- High pressure cylinder valve with RPV, packed needle stem design, for NO mixtures

D113 | PACKED VALVE

SPECIFICATIONS

Working pressure 200 bar/3000psi

Temperature range -40°C to +70°C

Helium leak rate at pmax

10-6 mbar l/sec10-5 mbar l/sec10-8 mbar l/sec

Flow coeffi cient Cv 0.3

Seat orifi ce size 3,3 mm

Body material Stainless steel

Residual pressure 1 to 5 bar

RPV seat material Viton®

KEY FEATURES

- Freedom from seizure when used with corrosive gases - gas does not come into contact with the valve operating mechanism

- Positive and eff ective operation - valve spindle is mechanically linked to the operating handwheel, which only requires low closing torque

- Long life - valve spindle and seat are replaceable - Adjustable gland packing - in the unlikely event of a leakage occuring past the valve spindle, when opening the valve, rectifi cation is readily achieved by retightening the gland packing nut

- Low internal volume - this is particularly benefi cial, when using the valve for hygroscopic, corrosive or high purity gases, here inert gas purging may be necessary before opening or after closing the valve

- Left hand threaded counter screw to secure sealing mechanism even under excessive torque

12

3~

6 3~

3 9 , 5~7 , 5~

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

"NO mixture up to 1000 ppm” ¾ " NGT OBS 200bar 200 ISO 5145 ISO None N

25E B CGA V1 CGA CGA S1.1 CGA

Can be connected with Ceodeux Meditec regulators

Ref catalog: MPR-EN-1115

Page 29: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

SPECIAL NITRIC OXIDE CYLINDER VALVE 29

- High fl ow cylinder valves with RPV, tied diaphragm seal type, for NO mixtures

D413 | TIED DIAPHRAGM

KEY FEATURES

- Reduced dead spaces and gas wetted volumes allow easy purging process

- Freedom of internal threads and springs insures minimum particulate generation

- Very low internal volume with minimum dead spaces. This is particularly benefi cial, when using the valve for hygroscopic, corrosive, pyrophoric or high purity gases where inert gas purging is necessary before opening or after closing the valve

- Freedom from seizure where used with corrosive gases.Gas does not come into contact with the valve operating mechanism

- Positive and eff ective operation, valve lower spindle is mechanically linked to the upper spindle and the operating handwheel

- Backed up welded diaphragms provide a permanent and durable gas tight seal

- O-Rings in the gland and on spindle guarantee a secondary sealing

- Threaded vent hole

SPECIFICATIONS

Working pressure 200 bar/3000 psi

Temperature range -40°C to +70°C

Helium leak rate at pmax

10-8 mbar l/sec

Flow coeffi cient Cv 0,35

Seat orifi ce size 4 mm

Gas wetted materials PCTFE

Body material 316L Stainless steel

Residual pressure 1 to 5 bar

RPV seat material Viton®

7 , 5~ 5 6~

12

0~

5 4~

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

"NO mixture up to 1000 ppm” ¾ " NGT OBS 200bar 200 ISO 5145 ISO None N

25E B CGA V1 CGA CGA S1.1 CGA

Can be connected with Ceodeux Meditec regulators

Ref catalog: MPR-EN-1115

Page 30: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

SPECIAL NITRIC OXIDE CYLINDER VALVE30

SPECIFICATIONS

Working pressure 232 bar

Temperature range -25°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size 2.5 mm

Magnetic compatibility

yes

Key – operated chrome plated

Handwheel material plastic switch blade

Seat material PA 6.6

O-ring material EPDM

Body material Chrome plated brass

Filter material brass sintered

KEY FEATURES

- Low operating torque - MRI compatible - Key-operated or handwheel operating system - Safe, long, trouble-free life under all service conditions

- Testing according EN ISO 10297 and CGA U9 Standard

OPTIONS

- Inlets: 17E – 19E – 19T – LT – T – M18 – US threads - Natural brass - Burst disc safety device - Fusible metal safety device - Other fi lter (lang)

- High pressure brass cylinder valve for medical gases and oxygen,

- with yoke outlet connection (PIN INDEX System)

- O-ring-seal

M966 | PIN INDEX CYLINDER VALVE

Can be connected with Ceodeux Meditec regulators

I.E: Alpinox Pin indexRef catalog: MPR-EN-1115

10

3~

3 2~

* gas or mixture must be confi rmed

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 200bar 200 ISO 407 ISO None N

N2O N2O M18X1,5 RCS CGA CGA CGA S1.1 CGA

Various gases (*) VG * 25E B

CO2 CO2

Page 31: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

ALL RIGHTS OF CHANGE RESERVED

31PIN INDEX VALVE

- PIN INDEX valve for medical gases with active residual pressure function

M650 | PIN INDEX RPV CYLINDER VALVE

SPECIFICATIONS

Working pressure 232 bar

Temperature range -25°C to +70°C

Helium leak rate at pmax

10-3 mbar l/sec

Seat orifi ce size 2.5 mm

Cv 0.08

Magnetic compatibility

yes

Key – operated chrome plated

handwheel material removable plastic switch blade

Seat material PA 6.6

O-ring material EPDM

Body material chrome plated / natural brass

Filter material brass sintered

KEY FEATURES

- High tensile brass (CZ115) - Low operating torque - MRI compatible - Key-operated or handwheel operating system - Design and tested acc. EN849, EN ISO407, EN ISO15996 and CGA V9

- Residual pressure - Manufacturing in clean room

OPTIONS

- Inlets: 17E – 19E – 19T – LT – T – M18 – US threads - Natural brass - Burst disc safety device - Fusible metal safety device - Other fi lter (lang)Can be connected with

Ceodeux Meditec regulators

I.E: Alpinox Pin indexRef catalog: MPR-EN-1115

PRODUCT CONFIGURATOR

Gas Inlet Connection Working Pressure Outlet connection HP Safety

O2O2 17E A 200bar 200 ISO 407 ISO None N

N2O N2O M18X1,5 RCS CGA CGA CGA S1.1 CGA

Various gases (*) VG * 25E B

CO2 CO2

* gas or mixture must be confi rmed

Page 32: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

32

ALL RIGHTS OF CHANGE RESERVED

NOTES

Page 33: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

3333

ALL RIGHTS OF CHANGE RESERVED

NOTES

Page 34: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

A WORLD OF GAS CONTROL SOLUTIONSROTAREX is helping engineers worldwide to get better gas results: from ultra high purity production and medical care facilities to industrial and LPG applications, as well as alternative energy vehicles, fi re suppression, diving, aerospace, cryogenics, laboratory, petro-chemical and welding. ROTAREX applies over 90 years of know-how and experience to custom design, develop and manufacture the high performance valves, regulators and fi ttings to suit your needs, all in one hand. Discover the diff erence ROTAREX can make in your world.

COMPLETE SOLUTIONS FROM SOURCE TO PROCESS.

MEDITECCYLINDER VALVES EQUIPMENT FIRETEC AUTOMOTIVE LPG/SRG

Page 35: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

AUSTRALIA / BRASIL / CHINA / FRANCE / INDIA / ITALY / JAPAN / LUXEMBOURG / MIDDLE EAST / RUSSIA / S INGAPORE / SPAIN / THAILAND / USA

INDUSTRIALCYLINDER VALVES

UHPCYLINDER VALVES

MEDICAL VALVES& REGULATORS

FIRE SUPPRESSIONLPG VALVES

REGULATORS & GAUGES

SPECIALTY GAS VALVES REGULATORS & FITTINGS CRYOGENIC VALVES AUTOMOTIVE

WATERTEC

Page 36: TABLE OF CONTENTS - Rotarexrotarex.com/alpi-line/docs/MED_044_catalogue_valves_V13_e.pdf · TABLE OF CONTENTS 13485 QUALITY ASSURANCE ISO 0029 3 INTRODUCTION P.004 - Ceodeux meditec

www.rotarex.com

WORLDWIDE HEADQUARTERS

Ceodeux Meditec Customer Service

24 rue de Diekirch, B.P. 19

7505 Lintgen, Luxembourg

Tel.: +352 32 78 32 1

Fax: +352 32 78 32 854

E-mail: [email protected]

© 2012 - ROTAREX S.A.

CEODEUX MEDITEC - CEODEUX S.A.

MCV-EN-1115

REGIONAL / COUNTRY HEAD QUARTERS

NORTH AMERICA

USARotarex North America

221 Westec Drive

Westmoreland Technology Park I

Mt. Pleasant, Pennsylvania 15666 USA

Tel.: +1 724-696-43 40

Fax: +1 724-696-43 64

E-mail: [email protected]

SOUTH AMERICA

BRASILRotarex Brazil Ltda

Cond. Ind. Portal da Anhanguera Estr.

Municipal Gov. Mário Covas, S/N

13279-411 Bairro Macuco -Valinhos

São Paulo Brazil

Tel.: +55 19 3518 0800

Fax: +55 19 3869-1503

E-mail: [email protected]

EUROPE

FRANCE, BENELUX, GERMANY24, rue de Diekirch, BP 19

L-7505 Lintgen, Luxembourg

Tel.: +352 32 78 32-1

Fax: +352 32 78 32 317

E-mail: [email protected]

ITALYRotarex Italia S.r.l.

46 Via Giacomo Matteotti

I-25080, Ciliverghe di Mazzano (BS) Italy

Tel.: +39 030 212 05 50

Fax: +39 030 212 23 62

E-mail: [email protected]

SPAINRotarex Spain

C/Alcala, 4° Oficina 404

28014 Madrid

Tel.: +34 (91) 570 89 05

Mobile: + 34 (650) 908 856

E-mail: [email protected]

RUSSIARotarex Rus

Tverskaya street, 20/1 bldg. 1 of 506

125009, Moscow Russia

Tel.: +7 985 125 7776

Skype: rotarexrus

E-mail: [email protected]

POLANDRotarex Polska

13 Gröbli

PL 49-300 Brzeg, Poland

Tel.: +48 77 416 40 16

Fax: +48 77 416 20 99

E-mail: [email protected]

ASIA

MIDDLE EASTRotarex Middle East

Jebel Ali Free Zone - Lob 17, Office 415

P.O. Box 261749

Dubai, U.A.E.

Tel.: +971 (0) 4 887 6701

Fax: +971 (0) 4 887 6702

E-mail: [email protected]

CHINARotarex Star

60 Yuan Zhong Road

Shanghai Nanhui Industrial Zone

201300, Shanghai China

Tel.: +86-21 5800 4000

Fax: +86-21 5800 3226

E-mail: [email protected]

SINGAPORERotarex Fareast Pte Ltd

10 Ubi Crescent

Ubi Techpark, Lobby C, #06-55

408564 Singapore

Tel.: +65 64 72 37 27

Fax: +65 64 72 45 28

E-mail: [email protected]

JAPANRotarex Japan Ltd

6F, Yawaragi Bldg., 1-27-11 Taito

Taito-ku, Tokyo

110-0016 JAPAN

Tel.: +81 3 5817 8108

Mob.: +81 80 3755 2539

Fax: +81 3 5817 8168

E-mail: [email protected]

INDIARotarex ENGG. PVT. LTD.

C-105, Mahindra Apartments

Vikaspuri, New Delhi 110018

mob.: +91-9873467666

E-mail: [email protected]

THAILANDRotarex (Thailand) Co Ltd.

297, Wanglee Tower

3rd floor, Unit C, Surawong Road

Suriyawong, Bangrak,

Bangkok 10500 Thailand

Tel.: +66 2635 71 79

E-mail: [email protected]

SOUTH KOREARotarex Luz Tech Co.

305-500, 547 Yongsan-dong

Yuseong-gu

Taejon, Korea

Tel.: +82 42 825 8911

Fax: +82 42 825 8913

E-mail: [email protected]

OCEANIA

AUSTRALIARotarex Australia/New Zealand

Hornsby Heights,

Sydney, NSW, 2077

Tel.: +61 477 477 481

E-mail: [email protected]