t40.4757en

2
2010-08-24/00390093 Page 1/2 JUMO GmbH & Co. KG Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: [email protected] Internet: www.jumo.co.uk JUMO Process Control, Inc. 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: [email protected] Internet: www.jumo.us Supply isolator for Ex transmitters with 2-wire connection, HART ® capable Type KFD 2/HART II (1)GD, I (M1) [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C T amb +60 °C) [electric circuits in zone 0/1/2] General application The unit is used for the intrinsically safe supply and the electrical isolation of the output signal of transmitters with Ex protection. The supply isolator provides an intrinsically safe supply of 16.5 V DC. The intrinsically safe output signal of the supply isolator is electrically isolated through the isolating transformer. This means that it can be connected to instruments that do not have an intrinsically safe input and are located outside the hazardous (Ex) area. The supply isolator is suitable for providing power to the following instruments, e.g.: JUMO dTRANS p02 (Data Sheet 40404385); JUMO dTRANS p02 DELTA (Data Sheet 404382); JUMO dTRANS p20 (Data Sheet 403025); JUMO dTRANS p20 DELTA (Data Sheet 403022); JUMO dTRANS p33 (Data Sheet 404753); JUMO dTRANS T01 HART / Ex (Data Sheet 707010). Order example Supply isolator for Ex transmitters with 2-wire connection Type KFD 2/HART Sales No. 40/00389710 Ranges Supply unit Approval II (1)GD, I (M1) [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C T amb +60 °C) [electric circuits in zone 0/1/2] Input Ex ia IIC Supply voltage 20 — 35 V DC Ripple within the supply voltage tolerance Power consumption 2W approx. Supply for external transmitter Intrinsically safe circuit 16.5 V approx. at 20 mA Maximum values: max. voltage U 0 = 25.2 V DC max. current I K = 93 mA max. power P max. = 0.587 W Permissible capacitance at connection to pressure transmitter with Group Ex II C, C max. 107 nF with Group Ex II B, C max. 820 nF with Group Ex II A, C max. 2.9 μF Permissible inductance at connection to pressure transmitter with Group Ex II C, L max. 4.2 mH with Group Ex II B, L max. 17.3 mH with Group Ex II A, L max. 35.2 mH Isolating transformer Input 4 — 20 mA intrinsically safe circuit Output 4 — 20 mA Ripple: 10 μA p-p Transformer ratio 1:1 Burden resistance at the isolating transformer output R B = 1kΩ max. Total error at 20°C ± 10μA incl. non-linearity and burden variation Permissible ambient temperature -20 to +60°C Ambient temperature error ± 0.4μA per °C Permissible storage temperature -40 to +90°C Case mounting snapped on to 35mm standard rail to EN 60 715 A.1, or screwed on by 2 screws at 90mm spacing on pull-out lugs Protection EN 60 529 IP20 Electrical isolation Input/ output: to IEC/EN 60079-11 Input/ mains supply: to IEC/EN 60079-11 Weight 150g approx. Electromagnetic compatibility EN 61 326, EN 50 081-2, NAMUR NE21 Note on mounting The instrument must be mounted outside the area with an explosion hazard. Data Sheet 404757

Upload: alessandro-pandolfini

Post on 11-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

 

TRANSCRIPT

Page 1: t40.4757en

2010-08-24/00390093

Page 1/2

JUMO GmbH & Co. KGDelivery address:Mackenrodtstraße 14,

36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607e-mail: [email protected]: www.jumo.net

JUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow, Essex CM 20 2TT, UKPhone: +44 1279 635533Fax: +44 1279 635262e-mail: [email protected]: www.jumo.co.uk

JUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO

1-800-554-JUMOFax: 315-697-5867e-mail: [email protected]: www.jumo.us

Supply isolator for Ex transmitterswith 2-wire connection, HART®capableType KFD 2/HART

II (1)GD, I (M1) [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C ≤ Tamb ≤ +60 °C) [electric circuits in zone 0/1/2]

General applicationThe unit is used for the intrinsically safe supply and the electrical isolation of the outputsignal of transmitters with Ex protection.The supply isolator provides an intrinsically safe supply of 16.5 V DC. The intrinsically safeoutput signal of the supply isolator is electrically isolated through the isolating transformer.This means that it can be connected to instruments that do not have an intrinsically safeinput and are located outside the hazardous (Ex) area.The supply isolator is suitable for providing power to the following instruments, e.g.:JUMO dTRANS p02 (Data Sheet 40404385); JUMO dTRANS p02 DELTA (Data Sheet 404382);JUMO dTRANS p20 (Data Sheet 403025);JUMO dTRANS p20 DELTA (Data Sheet 403022);JUMO dTRANS p33 (Data Sheet 404753); JUMO dTRANS T01 HART / Ex (Data Sheet 707010).

Order exampleSupply isolator for Ex transmitterswith 2-wire connectionType KFD 2/HARTSales No. 40/00389710

RangesSupply unit

Approval

II (1)GD, I (M1) [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C ≤ Tamb ≤ +60 °C) [electric circuits in zone 0/1/2]

Input

Ex ia IIC

Supply voltage20 — 35 V DC

Ripplewithin the supply voltage tolerance

Power consumption≤ 2W approx.

Supply for external transmitter

Intrinsically safe circuit16.5 V approx. at 20 mA

Maximum values:max. voltage U0 = 25.2 V DC max. current IK = 93 mAmax. power Pmax. = 0.587 W

Permissible capacitance at connection to pressure transmitterwith Group Ex II C, Cmax. ≤ 107 nFwith Group Ex II B, Cmax. ≤ 820 nFwith Group Ex II A, Cmax. ≤ 2.9 µF

Permissible inductance at connection to pressure transmitterwith Group Ex II C, Lmax. ≤ 4.2 mHwith Group Ex II B, Lmax. ≤ 17.3 mHwith Group Ex II A, Lmax. ≤ 35.2 mH

Isolating transformer

Input4 — 20 mAintrinsically safe circuit

Output4 — 20 mA Ripple: 10 µAp-p

Transformer ratio1:1

Burden resistanceat the isolating transformer outputRB = 1kΩ max.

Total error at 20°C≤ ± 10µA incl. non-linearity andburden variation

Permissible ambient temperature-20 to +60°C

Ambient temperature error≤ ± 0.4µA per °C

Permissible storage temperature

-40 to +90°C

Case mountingsnapped on to 35mm standard rail toEN 60 715 A.1, or screwed on by 2 screws at 90mm spacing on pull-out lugs

ProtectionEN 60 529 IP20

Electrical isolationInput/ output: to IEC/EN 60079-11Input/ mains supply: to IEC/EN 60079-11

Weight150g approx.

Electromagnetic compatibilityEN 61 326, EN 50 081-2, NAMUR NE21

Note on mountingThe instrument must be mounted outside the area with an explosion hazard.

Data Sheet 404757

Page 2: t40.4757en

2010-08-24/00390093

Page 2/2

JUMO GmbH & Co. KGDelivery address:Mackenrodtstraße 14,

36039 Fulda, GermanyPostal address: 36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +49 661 6003-607e-mail: [email protected]: www.jumo.net

JUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow, Essex CM 20 2TT, UKPhone: +44 1279 635533Fax: +44 1279 635262e-mail: [email protected]: www.jumo.co.uk

JUMO Process Control, Inc.8 Technology BoulevardCanastota, NY 13032, USAPhone: 315-697-JUMO

1-800-554-JUMOFax: 315-697-5867e-mail: [email protected]: www.jumo.us

Block diagram

Dimensions

Modular terminal box in Makrolon, flammability class to UL 94: V-0.Can be snapped on to 35mm standard rail to EN 60 715 A.1, or screwed on by 2 screws at 90mm spacing through pull-out lugs.

Input EEx ia IIC

2-wire transmitter

HART communicator

HART interface

1+

1+

2-

3-

12 11+ 9+ 10- 7+

Mains supply

8-Output 4 — 20 mA

Ex

area

Out

side

Ex

area

®

®

Pull-out lugsEx areaconnections

Electrical connection

Connection Terminals

Supply 20 — 35 V DC 7 +8 -

Signalinput

Supplyforexternalpressuretransmitter

4 — 20 mAintrinsicallysafe

16.5 V DCat 20mA

1 +3 -

Signaloutput

4 — 20 mA 9 +10 -

7 8 9121110

1 2 3654

Data Sheet 404757