T3103A(ms) Parameter Name T3103A(ms) Description In an intra-BSC handover, the timer T3103 is initiated after the BSC sends a handover command. Before the timer T3103 expires, the timer stops if the BSC receives a Handover Complete message. After the timer expires, the BSC sends a handover failure message. GUI Value Range [500,60000] Default Value 10000 Unit Milliseconds Step - Modification Rules None Configuration Policy If this timer is set to a higher value, this may waste the channel resources and cause the congestion. If this timer is set to a lower value, this may influence the handover success rate. Recommended Value 10000 Parameter Relationship None BSC Feature Channel Management Parameter Class Parameters About Radio Resources Caution None Parent topic: Cell Timers Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.

Upload: awansn1984

Post on 26-Oct-2015

9 views

Category:

Documents


0 download

DESCRIPTION

T3103A timer

TRANSCRIPT

Page 1: T3103A timer

T3103A(ms)

Parameter Name T3103A(ms)

Description In an intra-BSC handover, the timer T3103 is initiated after the BSC

sends a handover command. Before the timer T3103 expires, the timer

stops if the BSC receives a Handover Complete message. After the timer

expires, the BSC sends a handover failure message.

GUI Value Range [500,60000]

Default Value 10000

Unit Milliseconds

Step -

Modification Rules None

Configuration

Policy

If this timer is set to a higher value, this may waste the channel resources

and cause the congestion.

If this timer is set to a lower value, this may influence the handover

success rate.

Recommended

Value

10000

Parameter

Relationship

None

BSC Feature Channel Management

Parameter Class Parameters About Radio Resources

Caution None

Parent topic: Cell Timers

Huawei Proprietary and Confidential