Аt2327 data display · gost 27451-87, gost 29074-91, the alarm dosimeter complies with: iec...
TRANSCRIPT
Operating principle
Applications
FeaturesAlarm dosimeter is intended for radiation monitoring of radiation-sensitive
and radiation-dangerous areas and facilities
underground railway systems
Coach and railway terminals airports
high-security objects
Civil defence and security services facilities
Radiation detection and dosimetric
Radiological health care facilities
Nuclear industry facilities
Manufacturing facilities
laboratories
can be installed up to 1 km away from
Operational self check and fault
measurement from background to
Can operate over a wide temperature
diagnostics
Smart probe for gamma radiation
Internal backup power supply for up to 3 hour of off-line operation
High reliability
measuring
cases of threshold crossing
Detection unit and temperature probe
data display
Additional protection from direct weather
range
detector background
impact
emergency values
History logging of dose rate levels and
Wide range of gamma radiation dose rate
Automatic compensation of intrinsic
No dismantling for servicing
АТ2327 Alarm Dosimeter with Data Display
Control unit
Gamma radiation detection unit
Information about radiation
environment for citizens and staff
Gamma smart probe is used for measuring of radiation background level
Dosimeter operation algorithm provides measurement continuity rapid
reaction to background radiation level change and real time display of detection
unit data on external display
Control unit is responsible for controlling the operation modes performing
Ambient temperature and current time and date is additionally displayed
It hosts command console interface
adapter and backup power supply
Control unit is to be installed indoors
necessary calculations storing and
backing-up measurement results as well
as for supplying power to devices
INSTRUMENTS AND TECHNOLOGIES FOR NUCLEAR
MEASUREMENTS AND RADIATION MONITORING
Specification
Capabilities
Dose rate
Current date and time
Ambient temperature
dose equivalent rate
Limits of intrinsic relative plusmn15
Registered radiation type Gamma radiation
Ambient temperature monitoring range -30degC+50degC
Data display IР53
Energy dependence relative -25 to +35 (60 keV ndash 125 MeV)
Detector Geiger-Muller counter tube
Measurement range of ambient 01 microSvh 10 Svhndash
Response time for dose rate le3 s
measurement (for dose rate ge1 microSvh) (accuracy error leplusmn10)
137to 662 keV ( Cs)
Data display LED display with step brightness control
measurement error
Displayed information Dose rate ambient temperature current time and date
Time format HoursMinutes DaysMonths
Maximum legibility distance 30 m
Energy range 60 keV 3 MeVndash
-1Typical sensitivity 40 cps(microSvh137 to Cs gamma radiation )
at any time of day
Working temperature range Detection unit and data display -30degC to +50degC Control unit +5degС to +40degС
Relative humidity with air temperature le95
le+35degC without condensation
Protection class Detection unit IP57
Control unit IР31
Power supply 110-230 VAC 50-60 Hz
Backup power supply Integrated backup power supply +24 V
Power consumption 100 W max
Overall dimensions Data display with detection unit 1095x392x300 mm Control unit 500x650x150 mm
Burn-up life ge100 Sv
Weight Data display with detection unit 25 kg Control unit 30 kg
Design and specifications are subject to change without notice
IEC 61000-4-112004
IEC 61000-4-42004 IEC 61000-4-52005
Safety requirements of IEC 61010-12010
GOST 27451-87 GOST 29074-91
The alarm dosimeter complies with
IEC 61000-4-22008 IEC 61000-4-32008
EMC requirements of EN 550112009
IEC 61000-4-62008 IEC 61000-4-82009
АТ2327 Alarm Dosimeter with Data Display
5 Gikalo st Minsk 220005 Republic of BelarusTelFax +375-17-270-81-42E-mail infoatomtexcom
Specification
Capabilities
Dose rate
Current date and time
Ambient temperature
dose equivalent rate
Limits of intrinsic relative plusmn15
Registered radiation type Gamma radiation
Ambient temperature monitoring range -30degC+50degC
Data display IР53
Energy dependence relative -25 to +35 (60 keV ndash 125 MeV)
Detector Geiger-Muller counter tube
Measurement range of ambient 01 microSvh 10 Svhndash
Response time for dose rate le3 s
measurement (for dose rate ge1 microSvh) (accuracy error leplusmn10)
137to 662 keV ( Cs)
Data display LED display with step brightness control
measurement error
Displayed information Dose rate ambient temperature current time and date
Time format HoursMinutes DaysMonths
Maximum legibility distance 30 m
Energy range 60 keV 3 MeVndash
-1Typical sensitivity 40 cps(microSvh137 to Cs gamma radiation )
at any time of day
Working temperature range Detection unit and data display -30degC to +50degC Control unit +5degС to +40degС
Relative humidity with air temperature le95
le+35degC without condensation
Protection class Detection unit IP57
Control unit IР31
Power supply 110-230 VAC 50-60 Hz
Backup power supply Integrated backup power supply +24 V
Power consumption 100 W max
Overall dimensions Data display with detection unit 1095x392x300 mm Control unit 500x650x150 mm
Burn-up life ge100 Sv
Weight Data display with detection unit 25 kg Control unit 30 kg
Design and specifications are subject to change without notice
IEC 61000-4-112004
IEC 61000-4-42004 IEC 61000-4-52005
Safety requirements of IEC 61010-12010
GOST 27451-87 GOST 29074-91
The alarm dosimeter complies with
IEC 61000-4-22008 IEC 61000-4-32008
EMC requirements of EN 550112009
IEC 61000-4-62008 IEC 61000-4-82009
АТ2327 Alarm Dosimeter with Data Display
5 Gikalo st Minsk 220005 Republic of BelarusTelFax +375-17-270-81-42E-mail infoatomtexcom