system thermo act

8
THERMO-ACT AUTOMATIC FIRE EXTINGUISHING SYSTEM Don’t Compromise on Fire Safety… Always Choose Certified Quality ProductsQuick & Effective Action Automatic Fire Detection & Suppression Suppress Fires and Prevent Reflash More Coverage of Wetchemical

Upload: elrajil

Post on 15-Dec-2015

16 views

Category:

Documents


1 download

DESCRIPTION

presentation

TRANSCRIPT

THERMO-ACTAUTOMATIC FIRE EXTINGUISHING SYSTEM

Don’t Compromise on Fire Safety… Always Choose Certi�ed Quality Products…

Quick & E�ective Action

Automatic Fire Detection & Suppression

Suppress Fires and Prevent Re�ash

More Coverage of Wetchemical

www.sffeco .com2

Rev

7: 0

5/2

015

TEC

HN

ICA

L D

ATA

SH

EET

THERMO-ACTFire Extinguishing System

TABLE OF CONTENTS

NO. ITEMS PAGE NO.

I Table of Content 2

II Introduction 3

III Applications & Advantages 4

IV Problems & Solutions 5

IV System Components 6

V General Applications 7

s f f e c oFIRE PROTECTION ENGINEERS

3

Rev

7: 0

5/2

015

TEC

HN

ICA

L D

ATA

SH

EET

THERMO-ACTFire Extinguishing System

INTRODUCTION

SFFECO Thermo-Act systems are the advanced technology of automatic fire suppression systems.

The systems provide a self activating suppression system that suppresses fires in seconds. They are

simple design and installation with low maintenance, highly cost effective and reliable. The electrical

or pneumatic sources shall not be required to our Thermo-Act systems. The systems can be used in the

presence of an increased risk of fire.

SFFECO Thermo-Act systems utilize fire flexible tube for fire detection. Thus, the fire detection and

extinguishing system is not required to detect and discharge.

SFFECO Thermo-Act systems can be designed with commercial available agents including clean agent,

wet chemical, Foam, and dry powder. The systems may be arranged as:

Direct System

SFFECO Thermo-Act direct system for low pressure

agent as shown below uses the flexible tube

as both the detection device and extinguishing

discharge system. In case of fire, the section of

tube most exposed to heat will rupture forming a

discharge nozzle. The suppressant agent is then

completely released due to pressure drop in the

tube.

Indirect System

SFFECO Thermo-Act indirect system for low

pressure agent as shown below uses the tube as

a fire detection device only. The fire suppression

agent is delivered through a special copper or

stainless steel tubing system. Once the tube

ruptures due to heat exposure, the drop in

pressure activates the indirect valve to direct the

flow of suppression agent to diffuser nozzles via

a fixed tubing system. This system is usually used

in large areas.

www.sffeco .com4

Rev

7: 0

5/2

015

TEC

HN

ICA

L D

ATA

SH

EET

THERMO-ACTFire Extinguishing System

APPLICATIONS & ADVANTAGES

APPLICATIONS OF SFFECO THERMO-ACT SYSTEM:

Some application examples of where SFFECO Thermo-Act systems can be installed include:

Note:

Other applications that are not mentioned above may also utilize SFFECO Thermo-Act system. Please conform

to our technical personal for more details.

ADVANTAGES OF SFFECO THERMO-ACT SYSTEM:

• Residential Kitchenhood

• Medical / laboratory equipment.

• Electrical control panels. & Small electricl rooms

• UPS units.

• Computer / Data storage cabinets.

• Small Generator rooms.

• Small Storage areas.

• Switchgear.

• Cable duct.

• Escalator.

• Transmitters.

• Motor vehicles.

• EDM & CNC machining centers.

• Goods in transit.

• Test / Production equipment.

• Fume hoods and cabinets for laboratories.

• Vending machines.

• Display cabinets.

• Automated machinery.

• Cleaning Tanks

• Linear detection line.

• Rapid reaction time.

• 24 hours a day ready for use.

• No external power supply.

• Flexible positioning of the flexible tube.

• Can be installed into inaccessible areas.

• Minimal environmental damages.

• No accidental discharges through a disruption of

the fire detector

• Can be used in every environment (marine,

industrial atmosphere)

• Governmental and insurance approvals

• Not affected by vibration or knocks

• Quick and simple installation in new or existing

cabinets

• Low price - high performance relationship

• Minimum maintenance.

• Easy maintenance & checking

• Short delivery

• Easy replacement

• Different Sizes

s f f e c oFIRE PROTECTION ENGINEERS

5

Rev

7: 0

5/2

015

TEC

HN

ICA

L D

ATA

SH

EET

THERMO-ACTFire Extinguishing System

PROBLEMS & SOLUTIONS

The Problem

Electrical enclosures can be found in virtually any industrial or commercial space. In some cases the enclosure

might be a single small panel while in others it may involve a large room filled with electrical boxes. Should a

fire occur in one of these cabinets, it would typically destroy the contents, but unchecked the fire could take the

room or even the building, costing money and downtime.

Regardless of the number of enclosures, Thermo-Act offers a reliable, cost-effective method to increase the fire

protection of these areas by detecting and suppressing the fire in the cabinet itself.

The Solution

Because Thermo-Act takes the fire detection and suppression inside of the hazard, a growing fire can be

caught quickly, preventing the spread of fire to other parts of the building that would require firefighters or water

sprinklers to extinguish.

By containing the fire to the individual enclosure damage is limited to that enclosure and the collateral damage

often caused by traditional fire suppression is avoided.

Direct System

Sensing & Discharging Tube Sensing TubeDischarging Tube

Indirect System

www.sffeco .com6

Rev

7: 0

5/2

015

TEC

HN

ICA

L D

ATA

SH

EET

THERMO-ACTFire Extinguishing System

SYSTEM COMPONENTS

Flexible Tube:

• acts as a multi-sensor• made of a high-tech polymer• combines• long-time resistance• flexibility• temperature sensitivity• when bursting at the

hottest spot, it ruptures as a nozzle shape opening

• Different tempeature rating

Valve SideRelease

Side

Head Valve with Pressure Gauge

Cylinder:

The cylinders are used to store the extinguishing agent

Models:

Two different sizes of cylinders are available to hold different

capacities of extinguishing agent

Extinguishing Agent Capacity Models Agent Filling Volume

Clean Agent6 Kg SFTHF6 6 Kg

0% -5%10 Kg SFTHF10 10 Kg

Wet Chemical2 Kg SFWC2 2 Kg

0% -5%6 Kg SFWC6 6 Kg

Foam6 Ltr SFTF6 6 Litres

2% -2%10 Ltr SFTF10 10 Litres

Dry Powder2 Kg SFTW2 2 Kg

2% -2%6 Kg SFTW6 6 Kg

s f f e c oFIRE PROTECTION ENGINEERS

7

Rev

7: 0

5/2

015

TEC

HN

ICA

L D

ATA

SH

EET

THERMO-ACTFire Extinguishing System

GENERAL NOTEThese data sheets are the property of SFFECO. It shall not

be reproduced, copied, lent in any manner or used for

any other purpose other than that for which it is specially

furnished, except by written permission of SFFECO.

In line with our policy of continuous product improvement,

we reserve the right to modify specifications without prior

notice.

GENERAL APPLICATION