System Data Sheet High Performance Systems for New Build, Conversion and Refurbishment. CI/Sfb June 2010 (21) (Ln6) Acoustic isolation and energy insulating system for separating party cavity walls within multi-rise and attached developments. Monarfloor ® Wall Cap – Lamatherm isolates both masonry leaves of the party wall from the flanking wall, reducing the acoustic flanking sound transmission within the structure. Monarfloor ® Wall Cap – Lamatherm also provides effective edge sealing at the party wall flanking wall junction to reduce the thermal convection. The system also acts as the fire barrier for the party wall at this junction. Monarfloor ® Wall Cap – Lamatherm System System Kit Monarfloor ® Wall Cap – Lamatherm is available as a system kit comprising of 30 Wall Cap – Lamatherm Bats and 34 Wall Cap clips. Kits are available in 3 sizes to suit cavites 75-100mm. Features and Benefits Isolates the separating party cavity wall from the flanking wall. Reduces the flanking sound transmission energy within the structure. Superior acoustic isolation performance. Can be used as an isolator / innovative flanking detail with any masonry party cavity walls. Easily installed within current standard wall constructions. Significantly improves the acoustic isolation of the building when used in conjunction with other Monarfloor ® acoustic systems for party walls. When used with other Monarfloor ® systems, provides ‘effective edge sealing’ reducing the heat loss within the cavity and thus meeting the changes to Approved Document L1A of the Building Regulations for England and Wales. Ensures the robustness of other acoustic systems for party walls. Demonstrates a significant cost saving and flexibility in the design and build of the building. Surpasses performance requirements of Approved Document E of the Building Regulations. Can be used to improve the acoustic and thermal performance and gain credits towards The Code for Sustainable Homes. One system to address acoustic and thermal performance requirements for new-build dwellings. Monarfloor ® Wall Cap – Lamatherm Membrane Monarfloor ® Wall Cap Clips Composition Wall Cap Lamatherm Bats – Bitumen composite membrane with acoustically rated fillers and fire rated mineral wool bat. Wall Cap Clips – Structural grade galvanised steel. Sizes Wall Cap Lamatherm Bats – 460mm long, 85mm, 90mm and 110mm widths to suit cavities 75-100mm. Wall Cap Clips – 15mm wide x 104.9mm long x 75mm deep. Kit Weight 22kg (max) Product Data Installation See over for details. Wall Cap Clips retains the Wall Cap Membrane securely into place. MADE IN UK

Upload: lydien

Post on 05-Jun-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

System Data Sheet

High Performance Systems for New Build,Conversion and Refurbishment.

CI/Sfb June 2010(21) (Ln6)

Acoustic isolation and energyinsulating system for separatingparty cavity walls within multi-riseand attached developments.

Monarfloor® Wall Cap – Lamathermisolates both masonry leaves of theparty wall from the flanking wall,reducing the acoustic flanking soundtransmission within the structure.Monarfloor® Wall Cap – Lamathermalso provides effective edge sealing at the party wall flanking wall junctionto reduce the thermal convection.The system also acts as the fire barrierfor the party wall at this junction.

Monarfloor®

Wall Cap –LamathermSystem

System KitMonarfloor® Wall Cap – Lamatherm is available asa system kit comprising of 30 Wall Cap –Lamatherm Bats and 34 Wall Cap clips. Kits areavailable in 3 sizes to suit cavites 75-100mm.

Features and Benefits■ Isolates the separating party cavity wall from the flanking wall.

■ Reduces the flanking sound transmission energy within thestructure.

■ Superior acoustic isolation performance.

■ Can be used as an isolator / innovative flanking detail with anymasonry party cavity walls.

■ Easily installed within current standard wall constructions.

■ Significantly improves the acoustic isolation of the building whenused in conjunction with other Monarfloor® acoustic systems forparty walls.

■ When used with other Monarfloor® systems, provides ‘effectiveedge sealing’ reducing the heat loss within the cavity and thusmeeting the changes to Approved Document L1A of the BuildingRegulations for England and Wales.

■ Ensures the robustness of other acoustic systems for party walls.

■ Demonstrates a significant cost saving and flexibility in thedesign and build of the building.

■ Surpasses performance requirements of Approved Document Eof the Building Regulations.

■ Can be used to improve the acoustic and thermal performanceand gain credits towards The Code for Sustainable Homes.

■ One system to address acoustic and thermal performancerequirements for new-build dwellings.

Monarfloor®

Wall Cap –LamathermMembrane

Monarfloor®

Wall Cap Clips

Composition Wall Cap Lamatherm Bats –Bitumen composite membrane with acousticallyrated fillers and fire ratedmineral wool bat. Wall Cap Clips – Structuralgrade galvanised steel.

Sizes Wall Cap Lamatherm Bats –460mm long, 85mm, 90mmand 110mm widths to suitcavities 75-100mm. Wall CapClips – 15mm wide x104.9mm long x 75mm deep.

Kit Weight 22kg (max)

Product Data

InstallationSee over for details.

Wall CapClips –retains theWall CapMembranesecurely intoplace.

MADE IN UK

System Data Sheet

For further information call 0161 866 6540or visit www.monarfloor.co.uk

NOTE: This information is given in good faith being based on the latest knowledge known to Monarfloor® AcousticSystems. Whilst every effort has been made to ensure the contents of the publication are current while going to press,customers are advised that products, techniques and Codes of Practice are under constant review and liable to changewithout notice. Up to date information is available from our Technical Services Department on request.

Responsibility cannot be accepted for the application of products, and no claims can be considered, where themanufacturer’s instructions have not been followed. The user should not assume; based on information provided in thissheet, that the product is suitable for any abnormal use.

All products are sold subject to our standard terms and conditions of sale, a copy of which is available on request.

Technical SupportMonarfloor® Acoustic Systems offers FREE technical advice and assistanceon all aspects of acoustic systems.

We can also undertake site visits to provide contractors with advice andassistance at every stage of a project from concept to completion.

Monarfloor®

Wall Cap –LamathermSystemInstallation at a glance■ Set out and build the party walls, sequence

to suit the build but don’t bring through theflanking walls.

■ One the wall is constructed and dry, locateWall Cap clips equally one to each blockheight, up the entire height of the party wall.This operation can be carried out as each liftis being built dependant on sequencing.

■ Insert the Wall Cap – Lamatherm, ensuringthe mineral – wool bat is tight within thecavity.

■ Return the Wall Cap – Lamathermmembrane and locate within the Wall Capclips.

■ Proceed with the next layer, ensuring therebates within the mineral-wool areinterlocked snuggly.

■ Butt flanking walls to the party walls and tiein with wall ties.

■ Once complete bring through the flankingwalls and complete the build.

Related Products■ Monarfloor® Wall Cap 400 System –

acoustic isolation system for separating partycavity walls within multi-rise developments.

■ Monarfloor® Wall Cap 200 System –acoustic isolation system for separatingflanking walls within multi-rise developments.

■ Monarfloor® Bridgestop® System –acoustic isolation system for party walls onraft foundations or continual slab.

■ Monarfloor® Tranquilt® System –lightweight acoustics isolation system forrobust under screeds.

For full details refer to individual Monarfloor®

Product Data Sheets.

Icopal Limited

Barton Dock Road, Stretford, Manchester M32 0YLTelephone: 0161 866 6540 Fax: 0161 866 6527Email: [email protected]

Monarfloor® Wall Cap – Lamatherm: Detail at Party Wall/Flanking WallJunction (Plan View).

ICO

2080

–R

ev 0

6/10

Seperating PartyCavity Wall

External Flanking Wall

Monarfloor® Wall CapLamatherm

Monarfloor®

Wall Cap ClipsMonarfloor®

Wall CapMembrane

External Flanking Wall

LamathermEW Acoustic

Fire Stop