sylvania metalarc pulse start metal halide lamps · white light output and exceptional efficacy of...

6
SYLVANIA METALARC ® Pulse Start Metal Halide Lamps

Upload: others

Post on 27-May-2020

7 views

Category:

Documents


1 download

TRANSCRIPT

SYLVANIA METALARC®

Pulse Start Metal Halide Lamps

Improved Performance on Every LevelThe advanced arc tube design of SYLVANIA METALARC® PULSE STARTmetal halide lamps makes them superior to standard metal halide probestart lamps. Initial lumen output levels are similar to standard lamps, butmean and maintained lumen levels can be up to 30 percent higher. METALARC PULSE START lamp life can be up to two times the life of standard lamps and these high performance lamps reduce color temperature shift over the life of the lamp by as much as 400K. Other performance enhancements include reaching 90 percent of full light outputsignificantly earlier than standard lamps and reducing hot restrike time by up to 60 percent.

Reduced Initial, Operating and Maintenance CostsThe superior performance of METALARC PULSE START lamps translatesdirectly to cost savings in a number of ways. Higher maintained lumensmeans that potentially up to one-third fewer fixtures can be specified toachieve overall lighting goals, reducing both initial installation and operatingcosts. The extended service life of METALARC PULSE START lamps can cut relamping schedules in half. In commonly used high bay or pole-mounted fixtures, the potential savings in maintenance costs can be considerable.

Longer Life and Improved Lumen Maintenance

Higher Lumen Maintenance+Longer Life

Visit www.sylvania.com or call 1-800-LIGHTBULB for additional information.

METALARCPulseStart MET

ALA

PULS

ESTA

RT

METALARCPULSESTART METALARCPULSESTAR

25,000

16000 20000140001200010000800060004000

MS250/PS Pulse Start M250/U Standard

20000

Lum

ens

Operating Hours

22,500

20,000

17,500

15,000

12,500

10,000

7,500

5,000

2,500

0

WideRange of Superior Pulse Start Lamps

Dual Wattage Pulse StartNew SYLVANIA dual wattage METALARC® PULSE START lamps deliver increased flexibility and versatility. They can be run at a lowerwattage for increased energy savings or at a higher wattage forimproved light output. The 320/350W METALARC PULSE START lamp can be operated on either a 320W or 350W pulse start ballastwithout compromising performance, and delivers pulse start technologyin a compact BT28 jacket. The new 350/400W lamp can be operatedon a 350W or 400W pulse start ballast and can deliver performancesimilar to a single wattage lamp. For many facilities, dual wattage lampsare a great way to simplify inventory requirements.

Other High Wattage OptionsWhen the flexibility of a dual wattage lamp is not significant, SYLVANIAalso offers a range of high performance, single wattage METALARCPULSE START lamps from 250W to 1000W, all of which offer the long life and improved lumen maintenance of pulse start technology.

Low Wattage Pulse Start LampsMETALARC low wattage (≤150W) pulse start lamps allow the high white light output and exceptional efficacy of metal halide lighting to be used in a great variety of applications. PAR20, PAR30LN and PAR38lamps are ideal for display and accent lighting. E17 and T6 lamps provide ample flexibility in the choice of fixtures such as downlights, pendants, wall mounts and pole mounts. For applications that demandexcellent color rendering with pulse start technology METALARCPOWERBALL™ CERAMIC lamps are the best choice.

SYLVANIA METALARC® PULSE START High Wattage Pulse Start Lamps at a Glance

Wattage ANSI Ballast Bulb PRO-TECH Finish NAED Codes

175W M152, M137 ED17 No Clear & Coated 64170, 64171

175W M152, M137 ED28 No Clear & Coated 64815, 64816

250W M153 BT28 Yes Clear & Coated 64789, 64790

250W M153 BT28 No Clear & Coated 64578, 64617

320W M154, M132 BT28 Yes Clear & Coated 64507, 64646

320/350W M154, M132/M131 BT28 Yes Clear & Coated 64391, 64349

350/400W M131/M155, M135 BT37 Yes Clear & Coated 64769, 64770

400W M155, M135 BT37 No Clear & Coated 64525, 64527

750W M149 BT37 No Clear & Coated 64787, 64822

1000W M141 BT37 No Clear 64351

Low Wattage Pulse Start Lamps at a Glance*

Wattage Bulb Types

39W TC, T6, PAR20, PAR30LN

50W E17

70W TC, T6, T7, E17, PAR30LN, PAR38

100W E17, PAR38

150W T6, T7, E17, PAR38

PAR

T6ED17 T6E17BT37 BT28

*Contact your SYLVANIA representative for ordering codes.

Visit www.sylvania.com or call 1-800-LIGHTBULB for additional information.

Safe for Use in Open or Enclosed FixturesThe open fixture technology in SYLVANIA METALARC PRO-TECH®

lamps offers extra flexibility. Available in a full complement of lampwattages, these lamps were created to fill the need for a safe lightsource in applications where a protective lens on the metal halide fixture was either impractical or undesirable. METALARC PRO-TECHlamps enhance safety in open or enclosed fixtures with a shroudaround the arc tube or, in some cases, a thicker-walled bulb.

METALARC PRO-TECH® BenefitsThe ability to use open fixtures makes high output METALARC PRO-TECH lamps ideal for higher ceiling applications where enclosed fixtures might previously have been necessary. Open fixtures result in greater light output over life as well as lower maintenance costs because there are no lenses to gather dirt and dust or complicate lamp replacement procedures. In addition, METALARC PRO-TECH shroud technology reduces the lamp’s UV output compared to standard metal halide lamps.

SYLVANIA METALARC® PULSE START METALARC PRO-TECH® Lamps at a Glance*

Wattage Bulb Types

39W PAR20, PAR30LN

50W E17

70W E17, PAR30LN, PAR38

100W E17, PAR38

150W E17, PAR38

250W BT28

320/350W BT28

350/400W BT37

PROTECHPROTECHPR

Pulse Start and METALARC PRO-TECH® Combined

PROTECH

*Contact your SYLVANIA representative for ordering codes.

Visit www.sylvania.com or call 1-800-LIGHTBULB for additional information.

METALARC METALARC METALAR

METALARC

Premium Performance Pulse Start Technology

FEAT

UR

ES

BE

NE

FIT

Lots of Bright White LightMETALARC® PULSE START metal halide lamps are the most energy efficient source of white light availabletoday and are offered in extremely high lumen output configurations.

Enhanced Lumen MaintenanceThe advanced arc tube design of METALARC PULSE START lamps reduces blackening caused by tungstenevaporation. This feature results in significantly higher maintained lumens than standard metal halide lamps.

Long Life and Color StabilityThe unique pulse start system in METALARC PULSE START lamps provides up to two times the life and reduces color temperature shift by up to 400K comparedwith standard metal halide lamps.

Faster Warm-up and RestrikeCompared to standard metal halide lamps, METALARCPULSE START lamps reach 90 percent of full light output 30 percent faster and have a 60 percent shorter hotrestrike time.

Lamp and Ballast SystemsMETALARC PULSE START lamps may be combined with SYLVANIA HID ballasts to form a complete system.

Large Area LightingFor any indoor or outdoor application requiring lots of low cost, white light, SYLVANIA METALARC PULSE START lamps deliver the high efficacy and high lumen output you need.

Fewer Fixtures, Lower CostsWith their superior lumen maintenance, METALARC PULSE START lamps can allow you to achieve desiredlight levels with fewer fixtures. Combined with extended life, this feature can reduce maintenance costs.

Look Better LongerHigh color stability allows you to use METALARC PULSE START lamps for applications requiring good color quality.

Rapid ResponseAn installation can be made safer and more user friendlythanks to the quick warm-up and hot restrike times ofMETALARC PULSE START lamps.

Peace of MindBy combining METALARC PULSE START lamps on SYLVANIA HID ballasts, the installation is covered by a comprehensive system warranty.

Understanding METALARC®

PULSE START Technology

BEN

EFIT

S

In metal halide lamps, an arc passing between two electrodes in a pressurizedtube causes various metallicadditives to vaporize andrelease large amounts ofwhite light. METALARCPULSE START lamps use anarc tube with substantiallyhigher fill pressure than standard metal halide lamps.This reduces tungsten evap-oration off the electrodes,which lessens the darkeningof the arc tube. As a result,METALARC PULSE STARTlamps provide better lumenmaintenance, longer life andimproved color stability thantraditional probe start lamps.

electrode

electrode

arc tube with higher fill pressure

Standard Metal Halide Lamp

electrode

Bi-metal switch40 k Ω resistor

starting probe

electrode

METALARC PULSE START Lamp

© 2001 OSRAM SYLVANIA Inc. All rights reserved.

HID040R

SYLVANIA, METALARC, METALARCPRO-TECH and DESIGNER are registered trademarks of OSRAM SYLVANIA Inc.

United StatesOSRAM SYLVANIA100 Endicott Street Danvers, MA 01923 1-800-LIGHTBULBwww.sylvania.com

CanadaOSRAM SYLVANIALTD./LTÉE2001 Drew Road Mississauga, Ontario L5S 1S4 1-800-LIGHTBULBwww.sylvania.com

© 2003 OSRAM SYLVANIA Inc. All rights reserved.Product Photograpy

SYLVANIA METALARC®

Pulse Start Metal Halide Lamps