sylvania incandescent appliance & indicator lamps bulletin 1963
TRANSCRIPT
7/27/2019 Sylvania Incandescent Appliance & Indicator Lamps Bulletin 1963
http://slidepdf.com/reader/full/sylvania-incandescent-appliance-indicator-lamps-bulletin-1963 1/2
b@{a&t i
ds' trg
- '* . -,L
a-'. ",t- : s
r" -*i'-
re QTJXPfugffi XqT KIANUF'ACT{JRERS
xpa NE Worlcl's smallest, incandescent
stanclard voltage Pilot l-amp with high-
est "on-the-job" Iamp life and reliability.
Gives new eeonomy standards in terms
of unit cost anci lamp replacement
where vibraiion and shock exist.
6S6ldeal for use in appliances where vi-
bration and shock are not factors. Avail-
able also in 135,'145, and 155 volts iorextremely long iife.
7C7 Balh clear and white are available in
3000-hour life for use in NITE LlTES.
' aG7,1|GzDe Designed with special fila-
nrent and mounting construction to in-
sure inciefinite long life under static
conclitions, with dependable operation
irr laundry equipment where subjected
to oniy moderate vibration and shock.
"F0r aciual size 0i Other Lamps see lvl.0.L. 0n reverse side
g 6F7, 25TI 5ni-raNI ancj ttibr":lar" fJe*igired
[or efficient per{ornrance rn sewi':g n,a-
chines, washers, clryers, ancl vaeuum
cleaners where vibration is a factor.
These lanrps are designed for horizontal
burning only - but both lamps are also
available on special order for vertical
hurning"
25fXA, 4AT1E, 25T6yz Original showcase
lamps used in appliances for general
iliunnination where vibration and shock
are not present.
15511/102, 25A15, 4AAl5/, Used in
re{rigerators and other applications forgeneral lighting,
ti$A"1"5 29,,4#eg5/Pzlg A speclai basing
cernenf insures tap perfornnanee and
long liie under high tenirperature concli-
tions in range ovens" The smailer
40A15 12211 more readiiy adapts to de-
signs where space is limited,
.tsdt5 Used as a ballast lamp tor G4S'1 1
germicidal lamps in air puriflers and
urYgrS.
7/27/2019 Sylvania Incandescent Appliance & Indicator Lamps Bulletin 1963
http://slidepdf.com/reader/full/sylvania-incandescent-appliance-indicator-lamps-bulletin-1963 2/2
SYI.UANIA APPIIANCE, PITIIT AND INDICATIIR INCANDESGENT TAMPS
w*tt* Bul6 Bass Itotts..
i0rderi$s
Ah[revidtion Deia.lFtion
SlandardPaekage0nattity Class FilameEt
Approx.lloulsLits
ApFrsx.Lumsns M.0-1..
J a7,..:, $lide.i 120 120.PSB Pilot.il€ht 100 B ccTA 3000 1500 (EFC) 1n/aa
6 Sfi,' 'Cand;..
0anal..
.Caii.di.'
Cririid.,:c1na.
FC Bay
DC BayCarid.Cand,
Cand.
24.',.
a0.1,
32
std, 130
135, 145155
30
std, r3048.1r5-725
1r5.125130, 145
115.125.
€s,6
636
6S6, -
6S6
qs6
6S6 DC
656 DC636/cw6s^6/CW
656/CR
.6qA /?
Clear. l ndicatorClear.l ndicatorCleiir lndicator
.Clear lndicatoiClear lndicator
. Cl6ar lndicatorClear
lndicator.Cerarn ic. White.Cerarnic WhiteCeramic Red
Clear lndicatcir
zqu
?40
240
240
z4s
LzA
120
240
240
244
24A
E
B
B
B
B
B
B
B
aB
D
c7A
ciAc7Ac74c7A
c7A
c7Ac7Ac7A
c7A
C7A
rtuu1500
1500
1500
1500
1500
1500
1.509
1500
1500
1500
41
rYs.
L,/B'l7/E
1?/8
lVB'
lt3,/ti
in/rc
l?k1%
%
lY^
10 s6 CAnd,l
.l ntet;'BQ qay
Cand,..
%a; 250229
?30;:256
230, 25q
?30..250
10s6/10-
1056/13 .r
1os6/1gDC
10s611.1R.
Ctear Indicitot (2)
Cleirr fhdicatqr, (2)
Clear la.dicator (2)
Spraved r.R dd,(2) .
244
24il
ao24s
B
D
sB
CCTA
ccTACCTA
ccTA
1500
1500
1500
1500
74 r?/8
lrtAs
|.AtL|/B
I e7 Car.id;
Canu,
115'1?5
115,r25
t9/:?c7:/cw
..Clear. Nignt.LtghtCdramic White .
LqU
248 a(i7A
c7A3{.}Ul.}
3000
zLlB
TJ/a
10 C7 Oalid....
DC.,Bay
115-125
115;.125
7tic7, .
10c7Dc
rClear .Pifot (1)
Cldat. Pllot,(1)
z 0
120
B
6
c7Ac7A
40
39
zys.
?3h
15
'.':,:,,::
a ..:
f5l
L ,
,15:
t7.
415
,$11:
7,,
:'''rDe Bayi
.:D:Q.Bay
DC: BaY
iUQ,'iBaY'
'i:iMedium
.,rMediiimi",M.ediiiri
'rCthd:-'. -
-Inter;' .
,X1,, ,,
115-r-25.
,115,125
,rj , ,
:std, 130
: Std,:130
,115,.1e5 .
,115.125
, 115-125,
15T70C . r, r'. ,
15T7DC] ,:'
tSTTDclr F
LsrTSe Jtf ltL5415 ':,:..$ArbleL ,
lsst],1101'
L\77e.....:,., .
15T.7N :' .,, .: .
'-Clear llome .,. 'ABpfiance,.. . .
,' ebai Hofte , ....'Apblisncd (3,.5). ..
.lriaide:Faosted .. .
' Honi€ iApplja nce (3, 5)
. lnbide Frostedr... .
. Hoin<i.Appliiance (3, 4)
. lfiSide. iFrogted . . .
;Glezii.r'.'
'.lneid6 Fio'stdd ' ...
,. ,Retrtgetatot'r ',, . ... .,1
'' i0ldati;.. {ome...., : '. :'.
... Apittiariie,t3,:5)'Cbar,lH.om6:..r. ..,i. r
. AFI]liancd. (3. 5) I r. .. .
60
60
60
60
lzs120
u0
60
60
B
B
B
B
B
B
B
B
B
q1
c1
c1
c1
c9,
c9
C7A
*'..
c1
1000
1200
1200
4q0
r42L44
7t2
tf3
11"5
21,4
TVq
2Y+
7r/+
li/e
31/z
2t/4
?Y*
ZYa
?r'
z5
?s.
.....
.':.i]
,::.'i
5:
A15:r
,':I.T6Vz
T.8
T10
Msdium
l.ritdr. . .
{nter,Dc Bey
DOBiry..i
Cand; ..
lnter. i ..i
.QqrBay.i,
Der Fby.
FG aav
M€diu.m
.M.edi:nm
'I15-125.'...i
1?0, 125
std,13012A,72.5
120
20 ,
120 ,','
1?0, 125:130'.r 'il
uq;t1e5
i2s, ' ,,
std,130Strl, 130
25A15 . '.. ..
t5TFVzllF.
25T6 ,h..
25T6YIDCllF
25T6LbDCi
25T8C.r.. .' l
.25TgN. i'r,.
.2518DC.';.. .
z5T8rFO/l'F"
,25T8Dcll F/rl
25110 '' '
25r10ilF.
lflSide.Frosted .
Refiigeratorlnside Fiosted .
Show Case
Clear.Show Case
lnside FrostadScale flluminirtorCleir. Scale.
llluminator.Cleai.Home . .
. Appliance d3, 5)
Clear Hoi.ne'.,r,Apptiiancie (9; 5) ,
,,Cl€Ari H,Ori:le ..i..,Aarpfiaincd.,(3r; :$. i, ..
r. l,n'sidt F ostedl i .l]Hbi_.r.i.eiAppljance. . l
,:{3,,5):r '..., r'ir. ,' ..r. . ,
lnsidei'Ftosteilr . I .
. Hot.n6,.AFitlia.nce,r(3).CIeai S.ho\i Case
iilnsi,aJe.Fiosted., i
'.Show,.Crige. ..
120
60
60
60
60
60
60
qo
5
0
:60.60
B
B
B
B
.B
B
B
B
E
B
B
B
G9
c8
c8c8
c8
c1
c1
c1
c1
c1
C8
c8
1000
1 000
1000
1000
1000
-
:1000
1000
2.40
244
z4q
)2R
ZbU
255
3yz
1'/2
X'/2
5U
5Y2
zYB
2YB
?5/a
2Ys
z%
\t/B
5%
al5 Mrddiuir 1r,5 35A/A15iReSista,nc€. Ballagtlnside Frasted. .
{.35 arnp€)(36)..120 B c9 3000 3L/z
40i ,'415'
i'Ti0"li
Me+i-um
MediurnMiediirftMediuriMl}diurir.
11I:1?
lzg1?0,130std; 130
Std: '
404:5/1 :
40A75/2?4aAffi/2211
40T10 i''
40T10ltF r
lnside FrostedApplianee
elear Ovenelear Oven (6)
.Clear.Show Case
lnside.Fiosted. Show Case
LIU
120lag60
60
(-
CcB
s
uv
c9c9c8
c8
IUUU
10001000
1000
t000
44U
440440
430
4?5
3Yz
43yz
55/B
1Ve
fl - lndefinite I0ng life dependenton service conditions.
*2 - The.lamp circuit should be fusedfor l5 amps or less.
f3 - Average laboratory life is 200 hours forvacurm cleaner and 600 hours forsewing machine services.
f4 - Lamp designed for base-up orbase-down burning.
15 - Horizontal mounting is best.
16 - Design voltage - 125 volts.
,/36 - Designed tor service other thanillumination.
. - Aluminum Base
For engineering assistance in selectinglamps best suited to your needs, get in
touch with the nearest Sylvania DistrictSales Offlce or write direct,
SIAo;iiEBAZ' rEtEpnntttE e flEernnillcg
Win tl S A60 BOSTON STREET . SALEM . MASS,ACHUSETTS
| 22t