syl battery - risen energy2005 business started at ohno kungyokudo 1909 establish dks in japan 1918...
TRANSCRIPT
Address: No.23 Xingke Middle Road, Meilin Street, Ninghai County,Ningbo City, Zhejiang Province, 315609, China
Email: [email protected]
Tel: +(0086) 400-101-8585
SYL BATTERY Global ESS Solution ProviderSYL BATTERY
About Company
ESS Integration
1 GW / 2 GWh
NCM Cell Capacity
1 GWh
SYL BATTERY ESS has been started as a subsidiary of
Risen in 2018 with over 100 R&D engineers.
SYL BATTERY has acquired a subsidiary of DKS which has
century history cell technology. We also have cell, pack
production base and PCS, SCADA, EMS R&D base.
We focus on the design, plan, operation and maintenance of
the Residential, Commercial, Industrial and Utility ESS.
Product Portfolio
Business History of Energy Solutions
Global Networks
Introduction | Residential ESS | Containerized ESS | Battery | Case
Key Features
FrequencyRegulation
Grid Support
Peak LoadShifting
StabilizeVoltage
Cost-effective
UPS Function
SYL Battery provides wide variety of products, such as Battery, Pack, Rack, and Container that our customers can choose the better solution.
Started solar business
2002
Was founded inNinghai, Zhejiang
1986
Started PV module business
2006
IPO in Shenzhen GEMStock (300118)
2010
“Two New Strategies”Ranked “Top 500 World
Famous Brand of New Energy”
2017
Ranked BloombergTier 1 company
2015
Photon Ranking Top 2
2014
Elexcel corporation established for battery materials R&D
2002
Establish SYL (TIANJIN)
2005
Business started at Ohno Kungyokudo
1909
Establish DKS in Japan
1918
IPO
1949
2018 JAN: Set up SYL Battery Co., Ltd
2018 MAR: Acquire SYL (TIANJIN)
2018 JUL: Set up SYL (NINGBO)
2018
0201
Introduction
Grid-scale
Lithium-ionBattery Cell
Residential
C&I
Module, Pack Rack Container
Zhejiang, China
Ninghai, China (headquarters)
Jiangsu, China
Henan, China
Durango, Mexico
Nürnberg, Germany
Melbourne, Australia
California, America
Santiago, Chile
Brisbane, Australia
Bangalore, India
Porto-Novo, Benin
Beijing, China
Shanghai, China
Tokyo, Japan
Shaanxi, China
Mexico City, Mexico
London, UK
Business History of SYL
Business History of DKS
Sales Service CenterHeadquarters
Production Base
04
Introduction | Residential ESS | Containerized ESS | Battery | Case
Residential ESS
03
PV
Hybrid Inverter
Battery
Router
Load
Energy Meter Grid
Cloud
APP
Web
DC
AC
Communication
Wifi
For Residential Energy Storage System
All-In-One Residential ESS
5 kW / 4.5 kWh
Hybrid Inverter
3 / 3.6 / 4.6 / 5 kW
Battery Pack
4.5 / 9 / 13.5 / 18 kWh
Wifi MeterBattery Pack
5.12 / 10.24 kWh
Application
Time: 2019
Capacity: 5kW / 15.54kWh
Location: Ninghai
Time: 2019
Capacity: 5kW / 5.18kWh
Location: Ninghai
SYL Residential Products
Configuration
Key Component
Dimension (W*D*H) (mm)
Weight (kg)
Nominal Energy (kWh)
Nominal Voltage (V)
Operating Voltage (V)
Nominal Power (kW)
Max Power (W)
560*750*1400
300
26.6
266.4
240 ~ 298.8
13.5
13.5
26.6 kWh
2P72S
3Module+1BSPU
560*750*1400
365
35.5
355.2
320 ~ 398.4
17.75
17.75
35.5 kWh
2P96S
4Module+1BSPU
560*750*1400
430
44.4
444
400 ~ 498
22.2
22.2
44.4 kWh
2P120S
5Module+1BSPU
Introduction | Residential ESS | Containerized ESS | Battery | Case
Circuit Diagram
50 kW PCS and 142.08 kWh battery
Containerized system solution including PCS and battery
Multiple installation and minimized footprint
Applications for peak load shifting, frequency regulation and microgrid
System Features
DC Side
BMS Communication
DC Voltage Range (V)
Cell Capacity (Ah)
Energy (Wh)
Energy Density (Wh / kg)
Battery Capacity (kWh)
Battery Cluster
Nominal Voltage (V)
Nominal Grid Voltage (V)
Grid Voltage Range (V)
Nominal AC Power (kW)
Nominal AC Current (A)
Max AC Power (kW)
Max AC Current (A)
DC Current Component
THD
Grid Frequency Range (Hz)
Power Factor Range
Isolation Method
Nominal Grid Frequency (Hz)
Fire Protection Design
Operation Time (H)
Operating Temperature Range (℃)
Dimensions of PCS (W*H*D) (mm)
Dimensions of System (W*H*D) (mm)
Weight of PCS (kg)
PCS Communication Interface
PCS Communication Protocol
Cooling Concept of PCS
Certificate
Relative Humidity
Max. Working Altitude (m)
Cooling Concept of Battery Unit
Weight of System (t)
Protection Level
AC Side
General Data
Containerized ESS
0605
50
185
194.7
142.08
2
3.7
RS485, Ethernet
640 ~ 796.8
50
55
79.3
< 0.5%
< 3% (Rated Power)
440
916
50
45 ~ 55
1 (lagging) ~ 1 (leading)
Transformer
Yes
1
-30 ~ 50
IP54
600*800*278
2991*2591*2438
75
RS485, Ethernet
Modbus TCP / Modbus RTU
Temperature-controlled forced air cooling
CE, IEC62477, IEC61000
0 ~ 100%
4500 (>3000, derating)
Air Conditioning
3.5
360 ~ 440
50 kW / 142.08 kWh
Introduction | Residential ESS | Containerized ESS | Battery | Case
Circuit Diagram
100 kW PCS and 213 / 284 / 355 kWh battery
Containerized system solution including PCS and battery
Multiple installation and minimized footprint
Applications for peak load shifting, frequency regulation and microgrid
System Features
DC Side 100 kW / 213 kWh 100 kW / 284 kWh 100 kW / 355 kWh
284 kWh 355 kWh213 kWh
4 53
BMS Communication
DC Voltage Range (V)
Cell Capacity (Ah)
Energy (Wh)
Energy Density (Wh / kg)
Battery Capacity (kWh)
Battery Cluster
Nominal Voltage (V)
Nominal Grid Voltage (V)
Grid Voltage Range (V)
Nominal AC Power (kVA)
Max AC Power (kVA)
Nominal AC Current (A)
Max AC Current (A)
THD
Grid Frequency Range (Hz)
Power Factor Range
Isolation Method
Nominal Grid Frequency (Hz)
Fire Protection Design
Operation Time (H)
Operating Temperature Range (℃)
Dimensions of PCS (W*H*D) (mm)
Dimensions of System (W*H*D) (mm)
Weight of PCS (kg)
PCS Communication Interface
PCS Communication Protocol
Cooling Concept of PCS
Certificate
Relative Humidity
Max. Working Altitude (m)
Cooling Concept of Battery Unit
Weight of System (t) 6.6 7.26
Protection Level
AC Side
General Data
DC Current Component
50
185
194.7
3.7
RS485, Ethernet
640 ~ 796.8
100
110
360
150
< 3% (Rated Power)
400
50
45 ~ 55
0.9 (lagging) ~ 0.9 (leading)
Transformer
Yes
3.5
-30 ~ 50
IP54
806*1884*636
2991*2591*2438
750
RS485, Ethernet
Modbus TCP / Modbus RTU
Temperature-controlled forced air cooling
TUV, IEC62619, IEC61000, CE
0 ~ 95%
4500 (>3000, derating)
Air Conditioning
310~450
< 0.5%
0807
Containerized ESS
Introduction | Residential ESS | Containerized ESS | Battery | Case
DC Side
BMS Communication
DC Voltage Range (V)
Cell Capacity (Ah)
Energy (Wh)
Energy Density (Wh / kg)
Battery Capacity (kWh)
Battery Cluster
Nominal Voltage (V)
Nominal Grid Voltage (V)
Grid Voltage Range (V)
Nominal AC Power (kVA)
Max AC Power (kVA)
Max AC Current (A)
Nominal AC Current (A)
DC Current Component
THD
Grid Frequency Range (Hz)
Power Factor Range
Isolation Method
Nominal Grid Frequency (Hz)
Fire Protection Design
Operation Time (H)
Operating Temperature Range (℃)
Dimensions of PCS (W*H*D) (mm)
Dimensions of System (W*H*D) (mm)
Weight of PCS (t)
PCS Communication Interface
PCS Communication Protocol
Cooling Concept of PCS
Certificate
Relative Humidity
Max. Working Altitude (m)
Cooling Concept of Battery Unit
Weight of System (t)
250 kW / 497.28 kWh
50
185
194.7
497.28
7
3.7
RS485, Ethernet
640 ~ 796.8
250
275
397
< 0.5%
< 3% (Rated Power)
400
310 ~ 450
360
50
45 ~ 55
0.9 (lagging) ~ 0.9 (leading)
Transformer
Yes
2
-30 ~ 50
IP54
520*1880*655
6058*2591*2438
1700
RS485, Ethernet, CAN Modbus RTU
Modbus / IEC104
Temperature-controlled forced air cooling
IEC62619, IEC61000, SAA, G59, IEC62447-1, CE
0 ~ 95%
4500 (>3000, derating)
Air Conditioning
9
Protection Level
AC Side
General Data
Circuit Diagram
250 kW PCS and 497.28 kWh battery
Containerized system solution including PCS and battery
Multiple installation and minimized footprint
Applications for peak load shifting, frequency regulation and microgrid
System Features
1009
Containerized ESS
Circuit Diagram
500 kW PCS and 568 kWh battery
Containerized system solution including PCS and battery
Multiple installation and minimized footprint
Applications for peak load shifting, frequency regulation and microgrid
System Features
DC Side
BMS Communication
DC Voltage Range (V)
Cell Capacity (Ah)
Energy (Wh)
Energy Density (Wh / kg)
Battery Capacity (kWh)
Battery Cluster
Nominal Voltage (V)
Nominal Grid Voltage (V)
Grid Voltage Range (V)
Nominal AC Power (kW)
Max AC Power (kW)
Nominal AC Current (A)
Max AC Current (A)
DC Current Component
THD
Grid Frequency Range (Hz)
Power Factor Range
Isolation Method
Nominal Grid Frequency (Hz)
Fire Protection Design
Operation Time (H)
Operating Temperature Range (℃)
Dimensions of PCS (W*H*D) (mm)
Dimensions of System (W*H*D) (mm)
Weight of PCS (kg)
PCS Communication Interface
PCS Communication Protocol
Cooling Concept of PCS
Certificate
Relative Humidity
Max. Working Altitude (m)
Cooling Concept of Battery Unit
Weight of System (t)
Protection Level
AC Side
General Data
Introduction | Residential ESS | Containerized ESS | Battery | Case
1211
50
185
194.7
568
8
3.7
RS485, Ethernet
640 ~ 796.8
500
550
721
794
< 0.5%
< 3% (Rated Power)
400
310~450
50
45 ~ 55
0.9 (lagging) ~ 0.9 (leading)
Transformerless
Yes
1
-30 ~ 50
IP54
520*1880*655
6058*2591*2438
800
RS485, Ethernet, CAN Modbus RTU
Modbus TCP / IEC104
Temperature-controlled forced air cooling
IEC62619, CE, IEC62477-1, IEC61000
0 ~ 95%
4500 (>3000, derating)
Air Conditioning
9
500 kW / 568 kWh
Containerized ESS
Introduction | Residential ESS | Containerized ESS | Battery | Case
1413
W T D
B C E
A1
A2
L
Size Code Size Item Nominal
Value (mm) Tolerance
(mm)
L Cell Length 278.5 ±2
W Cell Width 172 ±2
T Cell Thickness 11 ﹢0.5/-0.8
D Central Distance of Tabs 90 ±1
B Tab Width 50 ±0.2
E Tab Length 34.5 ±1
Thickness of Positive Tab 0.2 ±0.02
Thickness of Negative Tab 0.2 ±0.02
C Exposure Length of Tab glue 1.0 ±0.5
A1 Width of Top Sealing Edge 8 ±1
A2 Width of Bottom Sealing Edge 8 ±1
Safety
Long Cycle Life
Accurate Lifetime Simulation
Janpanese leading cell technology and professional production line to make sure the qualityof the battery.
SYL HIGH PERFORMANCE CELL≥ 5500 @ 25℃, 1C/1C, 80% DOD
Cell cycle data
Electrode Processing Chemicals Volume Area Pouch Product Line
Square Product Line
Pouch Laser Welder
Square Laser Welder
Commercial Charge/Discharge Test
Residential Charge/Discharge TestCore Assembly Dry Injection Area
OptimalBatterySolution
Customer’sLoad
Profile AgingParameter
Analysis
Lifetime / EstimationUsing / Semi-Empirical
/ Simulation Method
Simulation
OperationPlanning
Sizing
Battery
3.7 3.7
50 100
Nominal Voltage (V)
Nominal Capacity (Ah)
Nominal Specification SC50-HEL SC100-HEL
Charge
Discharge
50 (0℃ ~ 45℃)
4.2 3.65
25 (0℃ ~ 45℃)
100 (0℃ ~ 45℃)
50 (0℃ ~ 45℃)
Rapid Current (A)
Limited Voltage (V)
Standard Current (A)
50 (-20℃ ~ 50℃)
Max. Continuous Discharge Current (A) 100 (-20℃ ~ 50℃)
Standard Current (A)
3
50 (-20℃ ~ 50℃)
100 (-20℃ ~ 50℃)
2.5Limited Voltage (V)
≥ 3.6 (50% SOC) 3.2
950±50 2270±30
172*278.5*10.5 200.33*172.2*33.22
≤ 85% RH ≤ 85% RH
≤ 1 (50% SOC, AC 1 KHz) 0.39
Cycle Life ≥ 5500 (25℃, 1C/1C, 80% DOD) ≥ 5300 (25℃, 1C/1C, 100% DOD)
Deliver Voltage (V)
Weight (g)
Size (W*H*D) (mm)
Storage Humidity
Internal Impedance (mΩ)
SC50-HEL
Higher Energy Density Safety Test- Nail Penetration Test
Safer Cell Structure
Safety Test- Over Charge Test
Reinforced Ceramic Separator
Japan JET & PSE Certified Product
Saving at least 5% space
Stable cell structure to increase safety level
Introduction | Residential ESS | Containerized ESS | Battery | Case
1615
Dead Space
SYL Battery (Laminated Type) Prismatic battery (Rolled Type)
SYLBattery (Laminated Type) Prismatic battery (Rolled Type)
Reinforced Safety Ceramic Separator increases the mechanical and thermal stability of battery cells.
Micro porouspoly olefin film
Nano scaleCeramic particles
Separator technology with nano-coating of ceramic particles
Disharge Characteristics Charge Characteristics
Discharge at high temp. Discharge at low temp.
High-Speed Mixer
Slot Die Coater
Steel Roll (max100t)
Steel Roll (max18t)
Cutting Machine
Desiccant Dehumidifier
Introduction | Residential ESS | Containerized ESS | Battery | Case
Cell Production Base
Time: 2019 (In the Planning)
Composition: 250 KW PCS / 1.096 MWh Battery
Location: Mieken
Significance:
Solution for PV + Storage to realize good IRR
Spontaneous use
Time: 2019 (In the Planning)
Composition: 25 MW PCS / 55 MWh Battery
Location: Australia
Significance:
Solution for PV + Storage to realize good IRR
Frequency regulation
Peak load shifting
Time: 2019
Composition: 1 MW PCS / 4.24 MWh Battery
Location: Jintan
Significance:
Peak load shifting for users
Case
1817
Introduction | Residential ESS | Containerized ESS | Battery | Case
Time: 2018
Composition: 500 KW PCS / 914 KWh Battery
Location: Guangzhou
Significance:
Peak load shifting for users
Time: 2019
Composition: 2 MW PCS / 8.8 MWh Battery
Location: Nantong
Significance:
Peak load shifting for users
Time: 2019
Composition: 250 KW PCS / 1 MWh Battery
Location: Ningbo
Significance:
Solution for PV power generation abandonment
Frequency regulation
Case
2019