sydney september 2012 - global methane initiative€¦ · gmi-coal status update report sydney...
TRANSCRIPT
![Page 1: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/1.jpg)
MEGTEC VAM Processing GMI-Coal Status Update Report
Sydney September 2012 Richard Mattus
![Page 2: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/2.jpg)
MEGTEC VAM Power Plant WestVAMP at BHP Billiton in Australia
Commissioned in 1st Quarter 2007.
By 1st Q 2012 WestVAMP had generated;
> 165,000 MWh of electricity
> 1 million carbon credits (CO2e as NGAC’s).
10/10/2012 ©, 2011, MEGTEC Systems Inc. 2
![Page 3: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/3.jpg)
MEGTEC VAM in China 2011 Da Tong mine, ChonQing Province, China
� Investor is a joint venture owned by:
• SongZao Coal & Electricity Co Ltd
• AES Corp (US-based global power generation company)
• Shenzhen Dongjiang Environmental Renewable Energy Co Ltd
![Page 4: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/4.jpg)
MEGTEC VAM in China 2011 Da Tong mine, ChonQing Province, China
World’s largest VAM abatement plant in operation
in the ChongQing Province of China since mid 2011.
September 2012
![Page 5: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/5.jpg)
� 6 Vocsidizer units mounted on two levels
� Processing capacity is 375,000 Nm3/h of ventilation air � Includes hot water generation for local use
MEGTEC VAM in China 2011 Da Tong mine, ChonQing Province, China
![Page 6: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/6.jpg)
MEGTEC VAM in China 2011 Duerping mine, Shanxi Province, with Sindicatum
One Megtec 2-Can Regenerative Thermal Oxidizer (“RTO”) units with a capacity of 2,100 Nm3/min
One 1,200 Nm3/min capacity CH4MIN Regenerative Catalytic Oxidizer (“RCO”) built by Megtec.
The first commercial deployment of the CH4MIN catalytic technology. • The project is expected to generate 2 million CERs over its life. • Completion planned for 2nd half 2012. •
10/10/2012 ©, 2010, MEGTEC Systems Inc. 6
![Page 7: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/7.jpg)
--
10/10/2012 7
MEGTEC VAM demo installations Summary by September 2012
British Coal Demo 1994
Demo 2001 2002 BHP
CONSOL Energy Demo 2007 - 2008
• Demos
VAM Pilot Unit
2009
BHP, Appin Colliery Demo
2001 - 2002
![Page 8: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/8.jpg)
MEGTEC Commercial VAM installations Summary by September 2012
• Demos ZHENGZHOU
• Commercial British Coal DUERPING
2 units 2012, 2008
Demo 1994 RTO + CTO
(catalytic)
AES-SONGZAO
6 units
2011 BHP, Appin Colliery Demo
2001 - 2002
BHP Billiton VAM Pilot Unit
4 units 2009 -
2007
10/10/2012 8
![Page 9: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/9.jpg)
MEGTEC VAM STATUS 2012
MEGTEC VAM status achieved by 2012
Type of
installations
Number of
plants
Number of
RTO units
Approx total
processing
capacity in
Nm3/h
Year of installation
(Locations)
Demo / pilot 4 4 80,000 1994, 2001, 2007, 2009
(UK, Australia, USA)
Commercial;
- Completed 3 11 700,000 2007, 2008, 2011
(Australia, China)
- Under
completion
1 2 200,000 2012
(China)
10/10/2012 9©, 2010, MEGTEC Systems Inc.
Total of MEGTEC VAM plant operation experience ~14 years
Total of MEGTEC VAM RTO unit operation experience > 30 years
![Page 10: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/10.jpg)
VAM Cube 20 m x 25 m
MEGTEC VAM processing concept is modular, based on VOCSIDIZERs, stacked in arrangements of VAM Cubes, each Cube processing 250,000 Nm3/h.
![Page 11: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/11.jpg)
EElleeccttrriicciittyy from VAM Power Plant
0.3% 0.6% 0.9%
Heat straight from bed.
Water at 70 - 150oC
3 MWth
=
½ -1 MWe
11 MWth
=
3 -4 MWe
18 MWth
=
5 - 6 MWe
-- For each 250 000 Nm3/h of ventilation air - -
For large size plants, conversion
from thermal to electrical energy can
be expected to be around 30%, and
lower for smaller plants.
MEGTEC is also exploring other types
of VAM energy recovery and utilization.
![Page 12: Sydney September 2012 - Global Methane Initiative€¦ · GMI-Coal Status Update Report Sydney September 2012 Richard Mattus . 10/10/2012 MEGTEC VAM Power Plant. WestVAMP at BHP Billiton](https://reader035.vdocuments.mx/reader035/viewer/2022081601/6124bd03d1cdd941c0151005/html5/thumbnails/12.jpg)
Pilot VAM VOCSIDIZER - available in Australia for VAM processing demonstration
Thank you! [email protected]