SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA
version 3, release 05th Nov 2017
SWIMMING POOL HEAT PUMP UNIT
CONTENTS
1. Preface 1 2. Spec
2.1 Performance Data of Swimming Pool Heat Pump Unit 2
2.2 Dimensions for Swimming Pool Heat Pump Unit 4
3.2 Swimming Pool Heat Pumps Location 10
3.3 How Close to Your Pool? 10 3.4 Swimming Pool Heat Pumps Plumbing 11
3.5 Swimming Pool Heat Pumps Electrical Wiring 12
3.6 Initial Start-up of the Unit 12
4. Usage and Operation 13
4.1 Function of the controller 13
4.2 Usage of the controller 14 4.3 Parameter table 18
4.4 Mulfunction table 19
3. Installation and Connection 9 3.1 Installation of System 9
5. Maintenance and Inspection 20
6.Appendix 21
version 3, release 05th Nov 2017
1. PREFACE
In order to provide our customers with quality, reliability and versatility, this product has been
made to strict production standards. This manual includes all the necessary information about
installation, debugging, discharging and maintenance. Please read this manual carefully before
you open or maintain the unit. The manufacture of this product will not be held responsible if
someone is injured or the unit is damaged, as a result of improper installation, debugging, or
unnecessary maintenance. It is vital that the instructions within this manual are adhered to at all
dealer. Maintenance and operation must be carried out according to the recommended time and
frequency, as stated in this manual. Use genuine standard spare parts only. Failure to comply with these recommendations will invalidate the warranty.
Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature
constant. For split type unit, The indoor unit can be Discretely hidden or semi-hidden to suit a
luxury house. Our heat pump has following characteristics:
1 Durable The heat exchanger is made of PVC & Titanium tube which can withstand prolonged
exposure to swimming pool water.
The unit can be installed outdoors or indoors. 3
Quiet operation -noise fan motor,
which guarantees its quiet operation. 4 Advanced controlling
The unit includes micro-computer controlling, allowing all operation parameters to be set.
Operation status can be displayed on the LCD wire controller. Remote controller can be chosen
as future option.
1 version 3, release 05th Nov 2017
2.SPECIFICATION
2 .1 Perform ance data of Swimming Pool Heat Pump Unit
*** REFRIGERANT : R410A/R407C
2 version 3, release 05th Nov 2017
2 .2 Perform ance data of Swimming Pool Heat Pump Unit
*** REFRIGERANT : R410a/R407C
2.SPECIFICATION
3 version 3, release 05th Nov 2017
2.SPECIFICATION
2.2 Dimensions for Swimming Pool Hea t Pump Unit
4
620
G
F
E
77 330PHFD-02615
A
C
B
3601010645
D
202328PHFD-02620PHFD-02625
PHFD-02610 77 280360930545 152298
version 3, release 05th Nov 2017
H
H
620
550
2.SPECIFICATION
2.2 The dimensions for Swimming Pool Heat Pump Unit
5
version 3, release 05th Nov 2017
620
G
F
E
77 380
A
C
B
D
760 440 1114 177 470PHFD-02630
PHFD-02640PHFD-02645PHFD-02650PHFD-02660
77 500760 440 1114 177 470
77 700760 440 1114 177 470
H
H
710
950
1250
PHFD-02670 77 700760 540 1114 177 570 1250
2.SPECIFICATION
2.2 The dimensions for Swimming Pool Heat Pump Unit
6
G
F
E
A
C
B
D
PHFD-02710PHFD-02712PHFD-02713
77 4201050 640 1650 300 680
version 3, release 05th Nov 2017
H
1525
H
PHFD-02714
2.SPECIFICATION
2.2 The dimensions for Swimming Pool Heat Pump Unit
7
G
F
C
PHFD-02715730 5001005 1276 1614 304 1350
version 3, release 05th Nov 2017
1525
H
H
E
A
B
D
PHFD-02720
2.SPECIFICATION
2.2 The dimensions for Swimming Pool Heat Pump Unit
8
G
F
E
A
C
B
D
PHFD-02740730 500900 1276 2410 305 1350
A
PHFD-02730
version 3, release 05th Nov 2017
1525
H
H
3.INSTALLATION AND CONNECTION
3.1 Installation illustration
W a te r ou tlet
P ool
(o r o th e
Va lve
W a te r s upp ly
Installation items:
The factory only provides the main unit and the water unit; the other items in the illustration are
necessary spare parts for the water system ,that provided by users or the installer.
Attention:
1.Open valve and charge water. 2.Make sure that the pump and the water-
3.Close the valve and start the unit.
The schematic diagram is for reference only. Please check the water inlet/outlet label on the heat
pump while plumbing installation.
9 version 3, release 05th Nov 2017
3.INSTALLATION AND CONNECTION
3.2 Swimming Pool Heat Pumps Location
The unit will perform well in any outdoor location provided that the following three factors are
presented: 1 . Fresh Air - 2. Electric ity -
The unit may be installed virtually anywhere outdoors. For indoor pools please consult the
supplier. Unlike a gas heater, it has no draft or pilot light problem in a windy area. DO NOT place the unit in an enclosed area with a limited air volume, where the units
discharge air will be re-circulated. DO NOT place the unit to shrubs which can block air inlet. These locations deny the unit of a
delivery.
Air inlet
Air outlet
3.3 How Close To Your Pool?
Normally, the pool heat pump is installed within 5/7 metres of the pool. The longer the distance from
the pool, the greater the heat loss from the piping. For the most part ,the piping is buried. Therefore,
the heat loss is minimal for runs of up to15 meters(15 meters to and from the pump = 30 meters
total), unless the ground is wet or the water table is high. A very rough estimate of heat loss per 30
meters is 0.6 kW-hour,(2000BTU) for every 5
and the ground surrounding the pipe, which translates to about 3% to 5% increase in run time.
10 version 3, release 05th Nov 2017
3.INSTALLATION AND CONNECTION
3.4 Swimming Pool Heat Pumps Plumbing
ccording to the nameplate). The
Temperatures, The unit does not need copper heat sink piping. PVC pipe can be run straight into
the unit.
Location: Connect the unit in the pool pump return
and upstream of any chlorinators, ozonators or chemical pumps.
the
draining of unit for winterizing and to provide easier access should servicing be required.
To pool
PVC COUPLER RECOMMENDED(Provided)
From pump CONDENSATION
DRAIN BARB FTG
Condensation: Since the Heat pump cools down the air about 4 -5 , water may condense on the
designed to accept 20mm clear vinyl tubing which can be pushed on by hand and run to a suitable
drain. It is easy to mistake the condensation for a water leak inside the unit.
pump running. If the water stops running out of the basepan, it is condensation. AN EVEN
QUICKER WAY IS to TEST THE DRAIN WATER FOR CHLORINE - if the is no chlorine present,
then it's condensation.
11 version 3, release 05th Nov 2017
3.INSTALLATION AND CONNECTION
3.5 Swimming Pool Heat Pumps Electrical Wiring
NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it
required to protect you against short circuits inside the unit. Bonding is also required.
The unit has a separate molded-in junction box with a standard electrical conduit nipple already in
place. Just remove the screws and the front panel, feed your supply lines in through the conduit
nipple and wire-nut the electric supply wires to the three connections already in the junction box
(four connections if three phase). To complete electrical hookup, connect Heat Pump by electrical
ies)
to a dedicated AC power supply branch circuit equipped with the proper circuit breaker,
disconnect or time delay fuse protection.
Disconnect - A disconnect means (circuit breaker , fused or un-fused switch) should be located
within sight of and readily accessible from the unit, This is common practice on commercial and
residential air conditioners and heat pumps. It prevents remotely-energizing unattended equipment
3.6 Initial startup of the Unit
NOTE-
circulate water through the heat exchanger.
Start up Procedure - After installation is completed, you should follow these steps: 1. Turn on your 2. Turn on the electrical power supply to the unit, then press the key ON/OFF of wire
controller, It should start in several seconds.
3. After running a few minutes make sure the air leaving the top(side) of the unit is
cooler(Between 5-10 ) 4. 5. Allow the unit and pool pump to run 24 hours per day until desired pool water emperature is
reached. When the water-
automatically restart (as long as your pool pump is running)when the pool temperature drops more
than 2 below set temperature.
Time Delay- The unit is equipped with a 3 minute built-in solid state restart delay included to
protect control circuit components and to eliminate restart cycling and contactor chatter. This time
delay will automatically restart the unit approximately 3 minutes after each control circuit
interruption. Even a brief power interruption will activate the solid state 3 minute restart delay and
prevent the unit from starting until the 5 minute countdown is completed. Power interruptions
n.
12 version 3, release 05th Nov 2017
4.Usage a d Opera i nn t o
4.1. Function of the controller
power
water
temperature
setting
: timer
BUTTON NAME FUNCTION
power ON/OFF
up Change Mode or increase parameter values
down Manual defrost or increase parameter values
setting Inquiries and setting Query and set parameters
timer Timing
CAUTION: Only after unlocking can perform any operation
power
water
temperature
setting
: timer
Press�and�hold�”power”�3�seconds
When no key operation for about 60
seconds, the keys will be locked
automatically
power
water
temperature
setting
: timer
13 version 3, release 05th Nov 2017
4.USAGE
4.2 Usage of the controller
4.2.1 How to start heat pump
The unit can be turned�ON/OFF�by�pressing�“power”.
power power
Press”power”
Inlet water
temperature
The current
time
water water temperature temperature
setting
Press”power” setting
: timer : timer
The unit on
4.2.2 How to change mode
After unlocking, Press and hold" " 8 seconds. you can change mode.
power power
Standby
Press�and�hold” ”�8�s
water
water
temperature tempera ture
setting
”8�s setting
Press�and�hold” : timer : timer
Heating mode Cooling mode
power
power
Press�and�hold” ”�8�s
Operating water
water
temperature temperature
status setting
”8�s setting
Press�and�hold” : timer : timer
Heating mode Cooling mode
CAUTION: Regardless of unit operation or standby mode can be
changed. After changing the parameters set by the
new model run.
14
When the display ----"heating" mode
When the display ----"cooling" mode
When the display ----”auto” mode
version 3, release 05th Nov 2017
4.USAGE
4.2.3 How to set your desired water temperature.
After unlocking, Regardless of unit operation or standby mode can set your desired water
temperature.�Press�"▲�"�or "▼�".�"�Set temperature"�symbol�starts flashing and�display water set
temperature, then finger�press�"▲"�or�“�▼�"�key, you can change the water temperature setting.
Inlet water
temperature
power
set
temperature
setting
: timer
power
press�"▲"
set
temperature
setting
press “ ▼�"
: timer
After10 seconds After10 seconds
power power
water water
temperature temperature
setting
setting
: timer : timer
the settings.
4.2.4 How to change parameter setting.
er touch "setting" key and more than about 3 seconds when you
parameter settings after exit setting mode.
Enter the appropriate parameters,
press�"▲"�or “�▼�"�key�to change
the parameter settings.
power
power
press and hold
"setting" 3 seconds water
temperature
setting
setting
: timer setting timer
15 version 3, release 05th Nov 2017
4.USAGE
4.2.5 How to check parameter setting & measured values of current status.
After unlocking, Click "setting" , Enter the query parameter mode Er.
power power
press "setting" water
temperature
setting setting
: timer timer
inquire
Hint: When the system is a dual system, you can continue to query b1 to Er;
three systems can continue to query C1 to Er; four systems you can continue to query d1 to Er.
Code Meaning Code Meaning Code Meaning Code Meaning
A1 1# Coil temp. b1 2# Coil temp. c1 3# Coil temp. c1 4# Coil temp.
A2 1# Suction temp. b2 2# Suction temp. c2 3# Suction temp. c2 4# Suction temp.
A3 1# Exhaust temp. b3 2# Exhaust temp. c3 3# Exhaust temp. c3 4# Exhaust temp.
A4 Ambient temp. b4 Ambient temp. c4 Ambient temp. c4 Ambient temp.
A5 1# water outlet temp. b5 2# water outlet temp. c5 00 c5 00
A6 water inlet temp. b6 water inlet temp. c6 water inlet temp. c6 water inlet temp.
A7 Reserved b7 Reserved c7 Reserved c7 Reserved
A8 1# Comp. current b8 2# Comp. current c8 3# Comp. current c8 4# Comp. current
A9 1#Numerical expansion valve b9 2#Numerical expansion valve c9 3#Numerical expansion valve c9 4#Numerical expansion valve
Er Fault code Er Fault code Er Fault code Er Fault code
4.2.6 How to set clock. After unlocking, Press the "timer" key for more than 8 seconds until an audible tone is heard and the
keys.�Press the “timer”�key�for minute adjustment�and�repeat�as previous. Press�“timer”�key to�exit.
power power
press and hold "timer"
8 seconds water water
temperature temperature
setting
setting
: timer : timer
16 version 3, release 05th Nov 2017
4.USAGE
The heat pump consists of two separate timing functions. Timer 01 and 02 are used to set the ON/OFF times of the heat pump
within 24 hour period. Heat pump ON/OFF timers: 01----
ON/OFF timing 02----ON/OFF timing After unlocking, Press the "timer" key and enter timer 01 ON time as in clock setting section. Press “timer ” key again to set
timer 01 OFF time. Set the OFF time as in clock setting section. Repeat sequence until all timer settings are completed.
If , however ,a timer is not used, set ON and OFF times to 00:00. Timer setting can be randomly selected. For example, Timer
01 ON, Timer 02 OFF.
power
power
timer setting
setting
timer ON OFF
: timer
up with"▲ "or "▼ "
water
temperature
setting
timer ONOFF timer : timer
ON/OFF
After completing all timer settings, the
controller will display the above.
The cancel the timer feature, press�the�“timer” key�for�more than 3 seconds until
an audible tone is heard, then release key, timer is now cancelled.
4.2.9 Manual/forced defrosting.
Although this heat pump features an automatic defrosting function, a manual
defrosting function enables the user to manually defrost the heat pump when
unusual frosting appears.
make sure key-pad is unlocked. Ensure that heat pump unit is in running mode, displaying the
heat symbol. press�the�“▼" key for more than�8�seconds�until an�audible tone is heard, and release key. the
heat pump will be in defrosting mode and the "defrost" symbol will be on display.
water
temperature
power power
press�and�hold�“▼" 8 seconds
water
temperature
setting setting
: timer : timer
17 version 3, release 05th Nov 2017
4.USAGE
4.3 Parameter table
Channel
L1
///
L2
L3
L4
L5
L6
L7
h1
L9
L8
h2
h3
h4
p1
p2
p3
p4
p5
p6
F1
Parameter name Adjustment range Initial value
Pool water temperature
Pool water temperature display deviation value
Compressor starts with the set temperature deviation
Water pump run mode
Set max. temperature
Allow the auxiliary heating of the ambient temp. on
Reserved parameter
Reserved parameter
Compressor current protection settings
Fan for low speed when the ambient temperature set
Minimum defrost cycle (min)
Defrost start temperature setting
The maximum time set defrost
Exit defrost temperature setting
Electronic expansion valve timing cycle
Superheat
Soft protection exhaust temperature
Defrost electronic expansion valve opening
The min. number of steps to open the expansion valve
Superheat compensation
The number of online setting (Celsius / Fahrenheit Conversion )
300~120 min
0℃─15℃ 0
1℃─15℃ 2
10℃─80℃ 34
0℃─35℃ 0
/ /
/ /
0-33A 0
26
20-99min 45
-2
5-20min 10min
1℃─40℃ 20
20s-180s 30s
0
90
6℃─55℃ 50
6℃─30℃ 15
0℃─12℃ 4
1-16 (0-1) 1(0)
F2 20s-120s 60sTime delay time on line number
F3 Master control unit following 1-16 0
F4 Remote control allows 0-9 0
10℃─65℃
0℃─ -15℃
-8℃─15℃
70℃─135℃
18 version 3, release 05th Nov 2017
4.USAGE
4.4 Mulfunction table
power
error
setting
timer
inquire
Failure Description
Error
Failure Description
code
code
E1 Wrong phase E30 2# Suction temp. sensor broken
E2 Missing phase E31 Water pressure sensor broken
E3 E32 Cooling water temperature is too low
E5 1# High pressure protection E33 Freezing point of failure
E6 1# Low pressure protection E35 1# compressor overcurrent
E7 2# High pressure protection E36 2# compressor overcurrent
E8 2# Low pressure protection E37 1 # thermostat without water
E9 Communication link failure E38 2 # thermostat without water
E11 Limited time E39 Cooling water temperature is high
E12 1# High Exhaust temp. protection E63
E13 2# High Exhaust temp. protection E65 3# High pressure protection
E15 Water tank sensor broken E66 3# Low pressure protection
E16 1# coil sensor broken E67 4# High pressure protection
E17 2# coil sensor broken E68 4# Low pressure protection
E18 1# Exhaust temp.sensor broken E72 3# High Exhaust temp. protection
E19 2# Exhaust temp.sensor broken E73 4# High Exhaust temp. protection
E21 Ambient sensor broken E76 3# coil sensor broken
E22 water return temp.sensor broken E77 4# coil sensor broken
E23 water inlet temp.sensor broken E78 3# Exhaust temp.sensor broken
E25 Water level switch broken E79 4# Exhaust temp.sensor broken
E26 Water inlet temp.is too high E89 3# Suction temp. sensor broken
E27 1# Outlet water sensor broken E90 4# Suction temp. sensor broken
E28 2# Outlet water sensor broken E95 3# compressor overcurrent
E29 1# Suction temp. sensor broken E96 4# compressor overcurrent
19
Error
version 3, release 05th Nov 2017
5. MAINTENANCE AND INSPECTION
Check the water supply device and the release often. You should avoid the condition of no
it's performance and reliability. You
The area around the unit should be dry, clean and well ventilated. Clean the side heating
exchanger regularly to maintain good heat exchange as conserve energy .
technician . Check the power supply and cable connection often,.Should the unit begin to operate
a Discharge all water in the water pump and water system ,so that freezing of the water in the
pump or water system does not occur. You should discharge the water at the bottom of water
pump if the unit will not be used for an extended period of time. You should check the unit
20 version 3, release 05th Nov 2017
6.APPENDIX
6.1 .Caution & Warning 1.
dealer. for Europe market 2. This appliance can used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. for Europe market
Children shall not play with the appliance .Cleaning and user maintenance shall not be
made by children without supervision.
3. Please make sure that the unit and power connection have good earthing, otherwise may
cause electrical shock.
4. If the supply cord is damaged, it must be replaced by the manufacturer or our service agent
5. Directive 2002/96/EC (WEEE):
The symbol depicting a crossed-out waste bin that is underneath the appliance indicates
that this product, at the end of its useful life, must be handled separately from domestic
waste, must be taken to a recycling centre for electric and electronic devices or handed
back to the dealer when purchasing an equivalent appliance. 6. Directive 2002/95/EC (RoHs): This product is compliant with directive 2002/95/EC (RoHs)
concerning restrictions for the use of harmful substances in electric and electronic devices. 7.
8. Make sure that there is circuit breaker for the unit, lack of circuit breaker can lead to
9. The heat pump located inside the unit is equipped with an over-load protection system. It does
not allow for the unit to start for at least 3 minutes from a previous stoppage.
10.
authorized dealer. for North America market 11. Installation must be performed in accordance with the NEC/CEC by authorized person only. for
North America market 12. USE SUPPLY WIRES SUITABLE FOR 75 . 13. Caution: Single wall heat exchanger, not suitable for potable water connection.
14.The appliance shall be installed in accordance with national wiring regulations.
means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under overvoltage category III conditions,
16.An all-pole disconnection switch having a contact separation of at least 3mm in all poles
17.
21 version 3, release 05th Nov 2017
6.APPENDIX
6.2
1. Single phase unit
Nameplate Phase line Earth line MCB Creepage protector Signal line maximum
current
No more
30mA less than 0.1 sec
than 10A 2 1.5mm2 1.5mm2 20A
10~16A 2 2.5mm2 2.5mm2 32A 30mA less than 0.1 sec
16~25A 2 4mm2 4mm2 40A 30mA less than 0.1 sec
25~32A 2 6mm2 6mm2 40A 30mA less than 0.1 sec
32~40A 2 10mm2 10mm2 63A 30mA less than 0.1 sec n 0.5mm
2 40 ~63A 2 16mm2 16mm2 80A 30mA less than 0.1 sec
63~75A 2 25mm2 25mm2 100A 30mA less than 0.1 sec
75~101A 2 25mm2 25mm2 125A 30mA less than 0.1 sec
101~123A 2 35mm2 35mm2 160A 30mA less than 0.1 sec
123~148A 2 50mm2 50mm2 225A 30mA less than 0.1 sec
148~186A 2 70mm2 70mm2 250A 30mA less than 0.1 sec
186~224A 2 95mm2 95mm2 280A 30mA less than 0.1 sec
2. Three phase unit
Nameplate Phase line Earth line MCB Creepage protector Signal line maximum
current
No more 3 1.5mm2
30mA less than 0.1 sec
than 10A 1.5mm2 20A
10~16A 3 2.5mm2 2.5mm2 32A 30mA less than 0.1 sec
16~25A 3 4mm2 4mm2 40A 30mA less than 0.1 sec
25~32A 3 6mm2 6mm2 40A 30mA less than 0.1 sec
32~40A 3 10mm2 10mm2 63A 30mA less than 0.1 sec n 0.5mm
2 40 ~63A 3 16mm2 16mm2 80A 30mA less than 0.1 sec
63~75A 3 25mm2 25mm2 100A 30mA less than 0.1 sec
75~101A 3 25mm2 25mm2 125A 30mA less than 0.1 sec
101~123A 3 35mm2 35mm2 160A 30mA less than 0.1 sec
123~148A 3 50mm2 50mm2 225A 30mA less than 0.1 sec
148~186A 3 70mm2 70mm2 250A 30mA less than 0.1 sec
186~224A 3 95mm2 95mm2 280A 30mA less than 0.1 sec
When the unit will be installed at outdoor, please use the cable which can against UV.
22 version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
23
PHFD-02615 PHFD-02620
version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
24
PHFD-02625 PHFD-02630
version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
25
PHFD-02640 PHFD-02645PHFD-02650
PHFD-02660
version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
26
PHFD-02710 PHFD-02712PHFD-02713PHFD-02714
version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
27
PHFD-02715
version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
28
PHFD-02720
version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
29
PHFD-02730
version 3, release 05th Nov 2017
6.APPENDIX
3. Circuit diagram of the unit
30
PHFD-02740
version 3, release 05th Nov 2017
version 3, release 05th Nov 2017