svrf - series for commercial applications r-410a ultra ... … · all compressors with dc inverter...

12
TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial 03009020101 © Sedna Aire Europe GmbH 1 01/2014 SVRF - Series for commercial applications R-410A Ultra High Efficiency Heat Pumps 8 - 50 kW capacity cooling and heating Sedna Aire now offers very high efficient VRF heat pumps for commercial applications. They are very popular for commercial applications, where one outdoor unit may supply up to 26 indoor units. VRF (Variable Refrigerant Flow) means that the condenser unit adjusts its cooling/heating supply exactly to the current need through a variable flow of the refrigerant and offering so much higher efficiencies. Indoor units comprise cassettes, ducts, wall mounted and floor/- ceiling units. Duct units are available with different static pressures according to your special needs. They allow very easy integration into the existing buildings without major investment in building ducts or radiators. The systems use the more efficient and environmentally friendly refrigerant (R-410A). The new SVRF Series of Sedna Aire offers as well outstanding performance as environmental protection. These models with their high efficient compressors in DC-Inverter technology offer when matched with our Solarcool TM panel offer when matched with our Solarcool TM panel highest efficiency rates in the industry: SEER: 8 (Cooling) and SCOP: 5,2 (Heating). SolarCool…The Hotter it Gets, The Better It Works! FEATURES and BENEFITS Refrigerant (R-410A) - Earth friendly non-ozone depleting refrigerant VRF Split System - Variable control of the refrigerant according to the real needs of the building for reducing power consumption All compressors with DC Inverter technology - state of the art technology for high efficiency compressors - for a better control, less power consumption and for a longer lifetime Choice of different indoor unit types - Up to 26 indoor units per one outdoor unit for higher flexibility at your application Oil balance technology - controls the oil in the compressors over multiple outdoor units to achieve long life-time of the compressors Heat pump system - for cooling and heating in one system Wide operation range - -5 to 48°for cooling and -20 to 27°C for heating Long piping length - up to 1000 m and a lift of up to 110 m Compact design- for easy transport in the building Intelligent soft start - for faster start-up and lower current peaks at start-up High performance blue fin heat exchanger - for better and more efficient heat transfer Auto-addressing the indoor units - Faster and easier installation without manual programming Simple signal line connection - only one cable connects all indoor units with the outdoor unit Many comfort options - Night silent operation , intelligent defrosting and much more for better comfort Wide range of control options - Many different controllers and connectivity to major networks 2 Year Limited All Parts Warranty

Upload: others

Post on 20-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   1   01/2014 

    SVRF - Series for commercial applications R-410A Ultra High Efficiency Heat Pumps 8 - 50 kW capacity cooling and heating Sedna Aire now offers very high efficient VRF heat pumps for commercial applications. They are very popular for commercial applications, where one outdoor unit may supply up to 26 indoor units. VRF (Variable Refrigerant Flow) means that the condenser unit adjusts its cooling/heating supply exactly to the current need through a variable flow of the refrigerant and offering so much higher efficiencies.

    Indoor units comprise cassettes, ducts, wall mounted and floor/-ceiling units. Duct units are available with different static pressures according to your special needs. They allow very easy integration into the existing buildings without major investment in building ducts or radiators. The systems use the more efficient and environmentally friendly refrigerant (R-410A).

    The new SVRF Series of Sedna Aire offers as well outstanding performance as environmental protection. These models with their high efficient compressors in DC-Inverter technology offer when matched with our SolarcoolTM panel offer when matched with our SolarcoolTM panel highest efficiency rates in the industry: SEER: 8 (Cooling) and SCOP: 5,2 (Heating).

    SolarCool…The Hotter it Gets, The Better It Works!

    FEATURES and BENEFITS Refrigerant (R-410A) - Earth friendly non-ozone

    depleting refrigerant VRF Split System - Variable control of the

    refrigerant according to the real needs of the building for reducing power consumption

    All compressors with DC Inverter technology - state of the art technology for high efficiency compressors - for a better control, less power consumption and for a longer lifetime

    Choice of different indoor unit types - Up to 26 indoor units per one outdoor unit for higher flexibility at your application

    Oil balance technology - controls the oil in the compressors over multiple outdoor units to achieve long life-time of the compressors

    Heat pump system - for cooling and heating in one system

    Wide operation range - -5 to 48°for cooling and -20 to 27°C for heating

    Long piping length - up to 1000 m and a lift of up to 110 m

    Compact design- for easy transport in the building

    Intelligent soft start - for faster start-up and lower current peaks at start-up

    High performance blue fin heat exchanger - for better and more efficient heat transfer

    Auto-addressing the indoor units - Faster and easier installation without manual programming

    Simple signal line connection - only one cable connects all indoor units with the outdoor unit

    Many comfort options - Night silent operation , intelligent defrosting and much more for better comfort

    Wide range of control options - Many different controllers and connectivity to major networks

    2 Year Limited All Parts Warranty

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   2   01/2014 

    OUTDOOR MINI VRF - 1 (8 - 14 kW / 3 - 5,5 hp) : SPECIFICATIONS Model SVRF - Outdoor units SVRF 80 SVRF 100 SVRF 120 SVRF 140

    Type Mini-VRFClass size kW 8 10 12 14 Class size MBTU/h - Horsepowers 30 - 3 36 - 3,5 42 - 5 48 - 5,5

    Performance (a) Cooling - Cooling capacity - kW 7,2 9,0 12,3 14,0

    Cooling capacity min - max - kW 1,5 - 8 2 - 11 2,7 - 14,9 3,1 - 17,7 SolarCool power input min - max - kW (a) 0,2 - 1,9 0,2 - 2,4 0,3 - 3,2 0,4 - 3,6 SolarCool efficiency - SEER (b) 7,1 7,1 7,2 7,1 SolarCool efficiency class (b) A++ A++ A++ A+

    Heating - Heating capacity- kW 7,2 9,0 13,2 15,4 Heating capacity - max. - min. - kW 1,6 - 8,4 2,1 - 10,5 3,1 - 15,4 3,6 - 18 SolarCool power input min - max - kW (a) 0,2 - 2,3 0,2 - 2,8 0,3 - 4,4 0,4 - 5,3 SolarCool efficiency - SCOP(b) 5,1 5,0 4,9 4,6 SolarCool efficiency class (b) A+++ A+++ A++ A+

    Electric rating Voltage range / Frequency/Phases 220/50/1 220/50/1 380/50/3 380/50/3

    Compressor Number compressors (all DC-Inverter) 1 1 1 1 Type - DC Inverter Rotary Rotary Rotary Rotary Nominal Amps c) 10 10 9,3 9,3

    Outdoor unit Max. # indoor units connectables 4 5 6 7 Capacity modulation range indoor 45 - 130% 45 - 130% 45 - 130% 45 - 130% Ambient min./max. Temp. cooling (°C) -15~48 -15~48 -15~48 -15~48 Ambient min./max. Temp. heating (°C) -15~27 -15~27 -15~27 -15~27 Sound pressure dB(A) 56 57 57 57 Dimension net WxDxH (mm) 990x966x336 990x966x336 900x1327x320 900x1327x320

    Dimension packaged WxDxH (mm) 1120x1015x 435 1120x1015x

    435 1030x1456x

    435 1030x1456x

    435 Body dimensional code A A B B Weight unit - packaged (kg) 62 - 67 74 - 81 95 - 103 95 - 103

    Refrigerant suction line (d) Total pipe - longest pipe length (m) 100 - 70 100 - 70 100 - 70 100 - 70 Max lift between outdoor - indoor (m) 30 30 30 30 Max lift between indoor units (m) 8 8 8 8 Max length +lift Outdoor - Panel (m) 18 - 8 18 - 8 18 - 8 18 - 8 Diameter piping Liquid - Gas (inch) 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8"

    SolarCoolTM panels needed 1 1 1 1 Refrigerant R410

    Design pressure High - Low (MPa) 4,2 - 1,5 4,2 - 1,5 4,2 - 1,5 4,2 - 1,5 Charge (kg) 2,8 3,0 3,3 3,9 GWP - global warming potential (e) 1 925 1 925 1 925 1 925

    Warranty (years) 2 2 2 2 (a) All figures given for SolarCool mode with solar panel following ISO 5151 and EU-guideline 626/2011 (EN14 825) . Actual energy consumption and number

    of required panels may vary and will depend on how the appliance is used and where it is located (b) SEER, SCOP preliminary following EU-guideline 626/2011 (EN 14 825). EER does not refelect enough partial load pattern of Inverter compressors, so we

    switched over to SEER (c) Figures given for the mode without impact of solar panel (d) see separate graph for explanation (e) GWP acc. to EU-guideline 842/2006 Depending on local solar irradiance 1 or 2 panels

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   3   01/2014 

    OUTDOOR MINI VRF - 2 : (16 - 27 kW / 6 - 10 hp) : SPECIFICATIONS Model SVRF - Outdoor units SVRF 155 SVRF 200 SVRF 220 SVRF 270

    Type Mini-VRFClass size kW 15,5 20,0 22 27 Class size MBTU/h - Horsepowers 53 - 6 68 - 8 78 - 9 90 - 10

    Performance (a) Cooling - Cooling capacity - kW 15,5 19,5 22,4 26,0

    Cooling capacity min - max - kW 3,4 - 17,2 4,3 - 21,7 4,7 - 27,9 5,4 - 31,6 SolarCool power input min - max - kW (a) 0,5 - 4,6 0,5 - 5,9 0,5 - 6,6 0,6 - 7,5 SolarCool efficiency - SEER (b) 7,0 6,9 6,9 6,8 SolarCool efficiency class (b) A++ A++ A++ A++

    Heating - Heating capacity- kW 17,0 23,0 24,5 28,5 Heating capacity - max. - min. - kW 4 - 19,8 5,4 - 26,8 5,9 - 29,8 6,2 - 34,8 SolarCool power input min - max - kW (a) 0,4 - 6,2 0,5 - 8,1 0,6 - 8,9 0,7 - 10,9 SolarCool efficiency - SCOP(b) 4,6 4,6 4,5 4,5 SolarCool efficiency class (b) A++ A++ A+ A+

    Electric rating Voltage range / Frequency/Phases 380/50/3 380/50/3 380/50/3 380/50/3

    Compressor Number compressors (all DC-Inverter) 1 1 1 1 Type - DC Inverter Rotary Rotary Rotary Rotary Nominal Amps c) 12 15 17,2 18,7

    Outdoor unit Max. # indoor units connectables 8 10 11 12 Capacity modulation range indoor 45 - 130% 45 - 130% 45 - 130% 45 - 130% Ambient min./max. Temp. cooling (°C) -15~48 -15~48 -15~48 -15~48 Ambient min./max. Temp. heating (°C) -15~27 -15~27 -15~27 -15~27 Sound pressure dB(A) 57 59 59 59 Dimension net WxDxH (mm) 900x1327x320 1120x1560x415 1120x1560x415 1120x1560x415

    Dimension packaged WxDxH (mm) 1030x1456x 435 1255x1710x

    530 1255x1710x

    530 1255x1710x

    530 Body dimensional code B C C CWeight unit - packaged (kg) 107 - 118 137 - 149 147 - 163 147 - 163

    Refrigerant suction line (d) Total pipe - longest pipe length (m) 100 - 70 120 - 70 120 - 70 120 - 70 Max lift between outdoor - indoor (m) 30 30 30 30 Max lift between indoor units (m) 8 8 8 8 Max length +lift Outdoor - Panel (m) 18 - 8 18 - 8 18 - 8 18 - 8 Diameter piping Liquid - Gas (inch) 3/8" - 3/4" 3/8" - 3/4" 3/8" - 5/8" 3/8" - 7/8"

    SolarCoolTM panels needed 1 1 - 2 (f) 1 - 2 (f) 1 - 2 (f) Refrigerant R410

    Design pressure High - Low (MPa) 4,2 - 1,5 4,4 - 2,6 4,4 - 2,6 4,4 - 2,6 Charge (kg) 3,9 4,8 6,2 6,2 GWP - global warming potential (e) 1 925 1 925 1 925 1 925

    Warranty (years) 2 2 2 2 (c) All figures given for SolarCool mode with solar panel following ISO 5151 and EU-guideline 626/2011 (EN14 825) . Actual energy consumption and number

    of required panels may vary and will depend on how the appliance is used and where it is located (d) SEER, SCOP preliminary following EU-guideline 626/2011 (EN 14 825). EER does not refelect enough partial load pattern of Inverter compressors, so we

    switched over to SEER (c) Figures given for the mode without impact of solar panel (d) see separate graph for explanation (e) GWP acc. to EU-guideline 842/2006 Depending on local solar irradiance 1 or 2 panels

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   4   01/2014 

    OUTDOOR MODULAR SVRF: (25 - 45 kW / 8 - 16 hp) : SPECIFICATIONS (and higher by up to 6 modules placed in parallel operation)

    Model SVRF - Outdoor units SVRF 252 SVRF 280 SVRF 340 SVRF 400 SVRF 450

    Type SVRF+ 1 SVRF+ 2 Class size kW 25 28 34 40 45 Class size MBTU/h - Horsepowers 86 - 8 96 - 10 114 - 12 147 - 14 154 - 16

    Performance (a) Cooling - Cooling capacity - kW 25,2 27,5 32 39 45

    Cooling capacity min - max - kW 5,6 - 31,4 6,2 - 34,1 7,4 - 39,8 8,9 - 48,0 10 - 55 SolarCool power input min - max - kW (a) 0,5 - 5,8 0,5 - 6,9 0,7 - 8,3 0,9 - 11,0 1 - 13,0 SolarCool efficiency - SEER (b) 8,6 8,4 8,2 8,0 7,9 SolarCool efficiency class (b) A+++ A+++ A+++ A++ A++

    Heating - Heating capacity- kW 27 31,5 37,5 45 50 Heating capacity - max. - min. - kW 6,3 - 31,5 7,4 - 36,8 8,8 - 43,8 10,5 - 52,5 11,7 - 58,3 SolarCool power input min - max - kW (a) 0,5 - 8,4 0,6 - 9,4 0,7 - 11,7 0,9 - 14,7 1 - 16,9 SolarCool efficiency - SCOP(b) 5,4 5,1 5,1 4,9 4,7 SolarCool efficiency class (b) A+++ A+++ A+++ A++ A++

    Electric rating Voltage range / Frequency/Phases 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3

    Compressor Number compressors (all DC-Inverter) 1 1 2 2 2 Type - DC Inverter 1 x Scroll 1 x Scroll 2 x Scroll 2 x Scroll 2 x Scroll

    Outdoor unit Max. # indoor units connectables 13 16 20 23 26 Capacity modulation range indoor 50 - 130% 50 - 130% 50 - 130% 50 - 130% 50 - 130% Ambient min./max. Temp. cooling (°C) -15~48 -15~48 -15~48 -15~48 -15~48 Ambient min./max. Temp. heating (°C) -20~27 -20~27 -20~27 -20~27 -20~27 Sound pressure dB(A) 57 57 59 61 61 Dimension net WxDxH (mm) 960x1615x765 960x1615x765 1250x1615x765 1250x1615x765 1250x1615x765 Dimension packaged WxDxH (mm) 1025x1790x830 1025x1790x830 1310x1790x825 1310x1790x825 1310x1790x825 Body dimensional code C C D D D Weight unit - packaged (kg) 198 - 213 198 - 213 288 - 308 288 - 308 288 - 308

    Refrigerant suction line (d) Total pipe - longest pipe length (m) 1000 - 200 1000 - 200 1000 - 200 1000 - 200 1000 - 200 Max lift between outdoor - indoor (m) 110 110 110 110 110 Max lift between indoor units (m) 30 30 30 30 30 Max length +lift Outdoor - Panel (m) 18 - 8 18 - 8 18 - 8 18 - 8 18 - 8 Diameter piping Liquid - Gas (inch) 1/2" -1" 1/2" -1" 5/8" -1 1/4" 5/8" -1 1/4" 5/8" -1 1/4"

    SolarCoolTM panels needed 1 1 2 2 2 Refrigerant R410

    Design pressure High - Low (MPa) 4,2 - 1,5 4,2 - 1,5 4,2 - 1,5 4,2 - 1,5 4,2 - 1,5 Charge (kg) 9 9 12 15 15 GWP - global warming potential (e) 1 925 1 925 1 925 1 925 1 925

    Warranty (years) 2 2 2 2 2 (a) All figures given for SolarCool mode with solar panel following ISO 5151 and EU-guideline 626/2011 (EN14 825) . Actual energy consumption and number

    of required panels may vary and will depend on how the appliance is used and where it is located (b) SEER, SCOP preliminary following EU-guideline 626/2011 (EN 14 825). EER does not refelect enough partial load pattern of Inverter compressors, so we

    switched over to SEER (c) Figures given for the mode without impact of solar panel (d) see separate graph for explanation (e) GWP acc. to EU-guideline 842/2006 Depending on local solar irradiance 1 or 2 panels

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   5   01/2014 

    MAXIMUM PIPING LENGTHS AND LEVELS

    Mini-VRF SVRF Piping length

    Total piping length a (actual) 100 m 1000 m Maximum piping length (MPL)

    Actual 45 /60 m b 175 m Equivalent 50 /70 m b 200 m

    Max. equivalent length from 1st indoor branch to farthest indoor unit (1BRFLIU)

    20 m 40/90 m c

    Level difference

    Level difference between indoor and outdoor unit (LBO-IU)

    Outdoor above indoor units

    30 m 70 m

    Outdoor below indoor units

    20 m 110 m

    Level difference between indoor units (LBIU)

    8 m 30 m

    a: Equivalent length: multiply supply pipe (yellow) from first indoor branch to next branch x 2. See service manual for detailed calculation

    b: SVRF30+36: 45 m; SVRF 42, 48, 53: 60m c: special conditions apply for right column figure, see service manual

    DIMENSIONS MINI-VRF

    Model A B C D E F G H SVRF 80/100 895 590 313 302 355 333 975 862 SVRF 112-155 990 624 354 336 396 366 1075 966 SVRF 252-450 600 348 320 400 360 900 1327

    SVRF

    Type SVRF 252,

    SVRF 280 SVRF 340, 400, 450

    Number of Fans

    1 2

    Width W 960 1 250 Height H 1 615 1 615 Depth D 765 765

    Supply pipe from first indoor branch

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   6   01/2014 

    ONE CABLE WIRING AND AUTO ADDRESSING OF INDOOR UNITS All indoor units may be connected to the outdoor with one wire only - due to the bus system.

    The outdoor controller identifies all indoor units and sets himself the respective addresses automatically, quick and correctly. This speeds up the installation time and avoids errors due to any mismatch of addresses. One controller (wired or remote) may address every single indoor unit separately by its unique indoor address and change the parameters.

    OIL BALANCE AND RETURN TECHNOLOGY FOR HIGH RELIABILITY Individual oil balance vector control ensures that the compressors have enough oil - not too much and not too less oil.

    An oil separator for the (SVRF1+ and SVRF2+ series) separates the oil being discharged with the refrigerant from the compressor and balances it between the compressors. This ensures sufficient lubricant and safe operation of the compressors especially at lower rpms

    An oil return program in the controller monitors the run-time and system state and makes sure that enough oil is always in the compressors at any time.

    CONNECTIVITY OF INDOOR UNITS One outdoor unit may supply up to 29 indoor units depending on its size. The units may be cassettes, ducts, ceiling/floor and wall mount units. A special software is available to size the outdoor units based on the cooling/heating load of every room.

    Model

    SV

    RF

    80

    SV

    RF

    100

    SV

    RF

    120

    SV

    RF

    140

    SV

    RF

    155

    SV

    RF

    200

    SV

    RF

    220

    SV

    RF

    270

    SV

    RF

    252

    SV

    RF

    280

    SV

    RF

    340

    SV

    RF

    400

    SV

    RF

    450

    Model class Mini-VRF SVRF+1 SVRF+2

    Number of indoor units 4 5 6 7 8 10 11 12 13 16 20 23 26

    Auto addressing

    Manually addressing

    Oil separator

    To condenser

    Oil balancing line (green)

    From evaporator

    Dis

    char

    ge

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   7   01/2014 

    INDOOR UNITS SVRF: PHYSICAL AND ELECTRICAL SPECIFICATIONS CASSETTES INDOOR UNITS Cassettes are very popular in offices. They are mounted in detached ceilings and offer a 360° air flow in all four directions. They are very silent. The remote control has an internal sensor and allows to run the cassette with the temperature measured at the remote control. The SVC12 comes in EU-grid while the others comply to the larger standard.

    Model SVRF - Indoor cassettes SVCC 36 SVCC 56 SVCC 71 SVCC 90 SVCC 112 SVCC 140Type CassettesPerformance (a)

    Cooling - capacity (kW) 3,6 5,6 7,1 9,0 11,2 14,0 Heating - capacity (kW) 4,0 6,3 8,0 10,0 12,5 15,0 Air flow min - max (m³/h ) 540 - 780 660 - 865 750 - 1160 1120 - 1540 1120 - 1540 1280 - 1800Fan Steps 3 3 3 3 3 3 Sound pressure Lo - Hi dB(A) 35 - 42 35 - 42 39 - 45 43 - 48 43 - 48 44 - 50 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 55 75 82 160 160 170 Control unit - Remote Control RM05 RM05 RM05 RM05 RM05 RM05

    Dimension & weight EU grid yes no no no no no Dimension body net WxDxHx (mm) 570x570x260 840x840x300 840x840x300 840x840x300 840x840x300 840x840x300 Dimension body packaged WxDxH (mm) 675x675x285 955x955x317 955x955x317 955x955x317 955x955x317 955x955x317 Weight unit body net- packaged (kg) 21 - 28 26 - 30 26 - 30 32 - 37 32 - 37 32 - 37 Dimension panel net WxDxH (mm) 647x647x50 950x950x46 950x950x46 950x950x46 950x950x46 950x950x46 Dimension panel packaged WxDxH (mm) 705x705x113 1000x1000x60 1000x1000x60 1000x1000x60 1000x1000x60 1000x1000x60Weight panel net - packaged (kg) 3 - 5 6 - 8 6 - 8 6 - 8 6 - 8 6 - 8

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 1/4" - 1/2" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" Diameter drain outer - inner (mm) 25 - 20 32 - 28,5 32 - 28,5 32 - 28,5 32 - 28,5 32 - 28,5

    Warranty (years) 2 2 2 2 2 2

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   8   01/2014 

    LOW STATIC PRESSURE DUCT (Hotel) These ducts are very popular in hotels, because they are very silent. They need only a small part of detached ceilings, which often is just over the door entrance area. They may come with an optional chip card module.

    Model SVRF - Low pressure duct SVLD 28 SVLD 36 SVLD 45 SVLD 56Type Low static pressure duct Performance (a)

    Cooling - capacity (kW) 2,8 3,6 4,5 5,3 Heating - capacity (kW) 3,2 4,0 5,0 6,3 Air flow min - max (m³/h ) 270 - 530 270 - 530 520 - 770 520 - 770 Fan steps 3 3 3 3 Static pressure norm (Pa) 5 5 5 5 Sound pressure Lo - Hi dB(A) 30 - 36 30 - 36 31 - 37 31 - 37 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 40 40 40 56 Control unit - wired KJR10B KJR10B KJR10B KJR10B

    Dimension & weight Dimension body net WxDxHx (mm) 850x405x190 850x450x190 1030x430x190 1030x430x190Dimension body packaged WxDxH (mm) 903x445x277 903x445x277 1084x472x277 1084x472x277Weight unit body net- packaged (kg) 12 - 15 12 - 15 18 - 14 18 - 14

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 1/4" - 1/2" 1/4" - 1/2" 3/8" - 5/8" 3/8" - 5/8" Diameter drain outer - inner (mm) 20 - 15 20 - 15 20 - 15 20 - 15

    Warranty (years) 2 2 2 2

    CONCEALED DUCT A5 INDOOR UNITS Concealed ducts are very popular in offices. They need a detached ceiling and come with a wired controller.

    Model SVRF - Indoor concealed duct SVDC 36 SVDC 56 SVDC 71 SVDC 90 SVDC 112 SVDC 140Type Concealed ducts (A5 type) Performance (a)

    Cooling - capacity (kW) 3,6 5,6 7,1 9,0 11,2 14,0 Heating - capacity (kW) 4,0 6,3 8,0 10,0 12,5 15,5 Air flow min - max (m³/h ) 320 - 570 560 - 960 820 - 1210 860 - 1400 1400 - 1750 1250 - 1800Fan steps 4 4 4 4 4 4 Static pressure norm (Lo-Hi) (Pa) 10 (10-30) 10 (10-30) 10 (10-30) 20 (10-50) 40 (10-80) 40 (10-100) Sound pressure Lo - Hi dB(A) 36 - 39 36 - 41 35 - 42 37 - 45 38 - 48 39 - 48 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 61 92 125 200 313 274 Control unit - wired KJR-12B KJR-12B KJR-12B KJR-12B KJR-12B KJR-12B

    Dimension & weight Dimension body net WxDxHx (mm) 790x635x210 1010x635x210 1010x635x210 1230x775x270 1230x775x270 1290x865x300Dimension body packaged WxDxH (mm) 915x655x290 1135x655x290 1135x655x290 1355x795x350 1355x795x350 1400x925x375Weight unit body net- packaged (kg) 18 - 20 27 - 32 32 - 36 40 - 48 40 - 48 49 - 58

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 1/4" - 1/2" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" Diameter drain outer - inner (mm) 32 - 25 32 - 25 32 - 25 32 - 25 32 - 25 32 - 25

    Warranty (years) 2 2 2 2 2 2

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   9   01/2014 

    HIGH STATIC DUCT INDOOR UNITS

    High static ducts are for larger areas and extended ductworks. The max. distance for air supply from the duct unit to the ductwork is 14m at 6,5 m above floor level.

    Model SVRF - Indoor high static duct SVDH 71 SVDH 90 SVDH 112 SVDH 140 SVDH 200Type High static ducts (1) Performance (a)

    Cooling - capacity (kW) 7,1 9,0 11,2 14,0 20,0 Heating - capacity (kW) 8,0 10,0 12,5 16,0 22,5 Air flow min - max (m³/h ) 1240 - 1510 1510 - 1940 1650 - 2120 2230 - 3000 3600 - 4660 Fan steps 3 3 3 3 3 Static pressure norm (Lo-Hi) (Pa) 40(30-200) 40(30-200) 50(30-200) 50(30-200) 140(50-250) Sound pressure Lo - Hi dB(A) 44 - 48 47 - 52 47 - 52 48 - 53 52 - 59 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 263 423 524 724 1516 Control unit - wired KJR-10B KJR-10B KJR-12B KJR-12B KJR-12B

    Dimension & weight Dimension body net WxDxHx (mm) 952x690x420 952x690x420 952x690x420 1200x600x400 1443x810x470 Dimension body packaged WxDxH (mm) 1100x768x450 1100x768x450 1100x768x450 1430x768x450 1510x990x550 Weight unit body net- packaged (kg) 45 - 50 47 - 52 51 - 56 68 - 70 115 - 129

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 2x(3/8" - 3/4") Diameter drain outer - inner (mm) 32 - 25 32 - 25 32 - 25 32 - 25 32 - 25

    Warranty (years) 2 2 2 2 2

    Model SVRF - Indoor high static duct SVDH 250 SVDH 280 SVDH 400 SVDH 450 SVDH 560Type High static ducts (2) Performance (a)

    Cooling - capacity (kW) 25 28 40 45 56 Heating - capacity (kW) 26 31,5 45 50 63 Air flow min - max (m³/h ) 3600 - 4670 3600 - 4670 5000 - 7500 5000 - 7500 6550 - 9500 Fan steps 3 3 3 3 3 Static pressure norm (Lo-Hi) (Pa) 140(50-250) 140(50-250) 200(50-250) 200(50-250) 200(50-250) Sound pressure Lo - Hi dB(A) 52 - 59 52 - 59 56 - 61 56 - 61 57 - 63 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 1516 1516 2700 2700 3400 Control unit - wired KJR-12B KJR-12B KJR-12B KJR-12B KJR-12B

    Dimension & weight Dimension body net WxDxHx (mm) 1443x810x470 1443x810x470 1970x859x668 1970x859x668 1970x859x668 Dimension body packaged WxDxH (mm) 1510x990x550 1510x990x550 2095x964x800 2095x964x800 2095x964x800 Weight unit body net- packaged (kg) 115 - 129 115 - 129 232 - 245 232 - 245 232 - 245

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 2x(3/8" - 7/8") 2x(3/8" - 5/8") 2x(1/2" -1 1/8") 2x(1/2" -1 1/8") 2x(5/8" - 1 1/8")Diameter drain outer - inner (mm) 32 - 25 32 - 25 32 - 25 32 - 25 32 - 25

    Warranty (years) 2 2 2 2 2

    Max distance 14m

    Indoor unit

    Return air

    Supply air

    Outside air

    Level 6,5 m

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   10   01/2014 

    FLOOR/CEILING INDOOR UNITS These units may be installed either horizontally under the ceilings or vertically at walls. They are popular in shops or restaurants which have no detached ceilings. They are quiet, have auto-swing, wide angle flow and come with a built-in drain pump.

    Model SVRF - Indoor ceiling/floor SVCF 36 SVCF 56 SVCF 71 SVCF 90 SVCF112 SVCF 140 SVCF 160Type Floor/ceilingPerformance (a)

    Cooling - capacity (kW) 3,6 5,6 7,1 9,0 11,2 14,0 16,0 Heating - capacity (kW) 4,0 6,3 8,0 10,0 12,5 15,5 18,0 Air flow min - max (m³/h ) 500 - 650 500 - 800 500 - 800 700 - 1200 1730 - 1980 1730 - 1980 1730 - 1980Fan steps 3 3 3 3 3 3 3 Sound pressure Lo - Hi dB(A) 36 - 40 38 - 43 38 - 43 40 - 45 42 - 47 42 - 47 42 - 47 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 50 120 125 130 180 180 300 Control unit - remote RM-05 RM-05 RM-05 RM-05 RM-05 RM-05 RM-05

    Dimension & weight Dimension net WxHxD (mm) 990x660x206 990x660x206 990x660x206 1280x660x206 1670x680x244 1670x680x244 1670x680x244Dimension packed WxHxD (mm) 1100x745x300 1100x745x300 1100x745x300 1380x745x300 1764x760x330 1764x760x330 1775x760x372Weight unit net- packaged (kg) 26 - 32 25 - 34 28 - 34 34 - 41 54 - 59 54 - 59 58 - 63

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 1/4" -1/2" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" Diameter drain (mm) 16 16 16 16 16 16 16

    Warranty (years) 2 2 2 2 2 2 2

    FLOOR STANDING UNITS These units may be placed on floors. They are widely as replacement for radiators in heating applications. The pipes come from the back allowing beautiful installations.

    Model SVRF - Floor standing SVFS 28 SVFS 36 SVFS 56 SVFS 71 SVFS 80Type Performance (a)

    Cooling - capacity (kW) 2,8 3,6 5,6 7,1 8,0 Heating - capacity (kW) 3,2 4,0 6,3 8,0 9,0 Air flow min - max (m³/h ) 420 - 570 380 - 620 830 - 1150 870 - 1380 1020 - 1330 Fan steps 3 3 3 3 3 Sound pressure Lo - Hi dB(A) 29 - 36 30 - 37 31 - 41 33 - 44 33 - 44 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 46 46 88 130 130 Control unit - remote RM05 RM05 RM05 RM05 RM05

    Dimension & weight Dimension body net WxHxD (mm) 1000x625x220 1200x625x220 1500x625x220 1500x625x220 1500x625x220Dimension body packaged WxHxD (mm) 1182x722x312 1382x722x312 1589x722x312 1589x722x312 1682x722x312Weight unit body net- packaged (kg) 30 - 38 37 - 46 44 - 53 44 - 53 44 - 53

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 1/4" - 1/2" 1/4" - 1/2" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" Outer diameter drain (mm) 16 16 16 16 16

    Warranty (years) 2 2 2 2 2

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   11   01/2014 

    WALL MOUNTED INDOOR UNITS

    They are the standard units for small and medium rooms. They require no detached ceilings and may be easily installed. They are silent and come with Auto-Swing mode plus a LED display showing current status. The remote control has an internal sensor and allows running the cassette with the temperature measured at the remote control. The larger units have a different design (type R) than the smaller sizes (type S).

    Model SVRF - Wall mount unit SVWW 28 SVWW 36 SVWW 56 SVWW 71 SVWW 90Type Wall mounted units Unit type S S S R R Performance (a)

    Cooling - capacity (kW) ,8 3,6 5,6 7,1 9,0 Heating - capacity (kW) 3,2 4,0 6,3 8,0 10,0 Air flow min - max (m³/h ) 430 - 525 480 - 590 755 - 925 680 - 1190 640 - 1320 Fan steps 3 3 3 3 3 Sound pressure Lo - Hi dB(A) 29 - 35 29 - 35 34 - 40 39 - 45 41 - 47 Power supply 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 Power input (W) 28 28 45 79 95 Control unit - remote RM-05 RM-05 RM-05 RM-05 RM-05

    Dimension & weight Dimension body net WxHxD (mm) 915x290x230 915x290x230 1072x315x230 1250x325x230 1250x325x245Dimension body packaged WxHxD (mm) 1020x390x315 1020x390x315 1180x415x315 1345x335x430 1345x335x430Weight unit body net- packaged (kg) 13 - 16 13 - 16 15 - 19 20 - 25 20 - 25

    Refrigerant suction line & drain Diameter piping Liquid - Gas (inch) 1/4" -1/2" 1/4" -1/2" 3/8" - 5/8" 3/8" - 5/8" 3/8" - 5/8" Outer diameter drain (mm) 16,5 16,5 16,5 16,5 16,5

    Warranty (years) 2 2 2 2 2

    CONTROLLERS, NETWORKS AND COMMUNICATIONS

    INDOOR CONTROLLERS One standard remote controller (RM05) and 2 wired controllers are available to operate the units. Each controller controls the individual indoor unit. A card key interface for the wired controller is available. This allows to switch centrally the indoor unit on or off.

    RM05 KJR 10/12B Card interface

    S- type

    R- type

  • TECHNICAL SPECIFICATIONS SVRF Series – Heat pump, Commercial

    03009020101  © Sedna Aire Europe GmbH   12   01/2014 

    CENTRAL CONTROLLERS One central unit controls the whole system. Monitor and set all units and parameters (Locks, modes, schedules

    CCM 03 CCM 09

    CCM 03: controls up to 64 indoor units with a max cable length of 1 200m. Uses bus protocol on one cable to the outdoor unit for controlling all units. 3 lock modes: lock the users from wrong input: wireless remote controllers, lock the running mode or lock the central controller from unauthorized input. Display individual indoor unit’s working status and error codes Filter reminding function Connectivity to BACNet, Modbus

    CCM 09: Additionally weekly schedule; set 4 periods per day and select mode and room temperature for single or all indoor units

    Specification: 179x 119x74 mm, Power supply 220V/50/1,

    NETWORK GATEWAYS Gateways to all major building service control software.

    BACnet Modbus Lonmark

    Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1 925. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1 925 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself. Always ask a professional.

    CERTIFICATIONS CE European certifications passed Sedna Aire has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. SolarcoolTM is a trademark of Sedna Aire Europe