svc-br-9101773-en - draeger

6
Rethink Ventilation in the Operating Room Safe – Spontaneous – Simple D-2413-2016 SMART VENTILATION CONTROL (SVC) VENTILATION OPTION OF DRÄGER ZEUS® INFINITY® EMPOWERED

Upload: others

Post on 01-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: svc-br-9101773-en - Draeger

| 4

Rethink Ventilation in the Operating Room Safe – Spontaneous – Simple

D-2

413-

2016

SMART VENTILATION CONTROL (SVC)VENTILATION OPTION OF DRÄGER ZEUS® INFINITY® EMPOWERED

Page 2: svc-br-9101773-en - Draeger

ST-

6168

-200

7_10

00

Low tidal volume built-in

StudiesclearlydemonstratetheadvantagesofusinglungprotectiveventilationstrategiesintheORinordertoreducetheincidenceofpostoper-ativepulmonarycomplications.SmartVentilationControl(SVC)supportscliniciansincomplyingwithrecommendationstoprotectthelungsofsurgicalpatients.Oncethetargetrangesfortidal

volumeandend-tidalcarbondioxide(etCO2)aredefined,yourventilationassistant,SVC,ensuresthatventilationstayswithintheseranges.

SVChelpstosecureventilationqualityandcompliancewiththemostcurrentstandardofcare–safe,spontaneous,simple!

SafeLung Protective Ventilation during Anaesthesia

02 |

SimilartoaLaneKeepingAssist,SVCisananaesthetistassistsystemthatkeepsthepatientinaprotectiverange.YoucansettheetCO2ranges,likethelanesoftheroad,andSVCwillkeepyourpatientsventilationwithinthedesiredranges.

D-2

366-

2016

D-2

368-

2016

Page 3: svc-br-9101773-en - Draeger

CurrentdiscussionsonprotectiveventilationstrategiesintheORaimtoreducepulmonarycomplicationsbycounteractingtheeffectsofmechanicalventilation.RecentfindingsintheICUhaveledtoincreasingdeploymentofspontaneousbreathingtothebenefitofpatients.IntheOR,SmartVentilationControlnowsupportsthepa-tient-orientedtransitionbetweenfullycontrolled,

assistedandspontaneousventilation.Itcanautomaticallyreducetheventilatorsupportfrompurecontrolledventilationuntilthepatientisreadyforextubation.

SVCensuresthattheemergingrespiratorydriveisgentlybeingtakencareofandspontaneousbreathingisbeingfostered–safe,spontaneous,simple!

SpontaneousMaximise Spontaneous Breathing during Anaesthesia

The earlier the better

Theearlierapatientcanbreathespontaneouslythroughoutacasethebetter.SVCenablesthesmoothtransitionbetween100%controlledventilationandspontaneousbreathing,wheneverthepatientisabletodoso–possiblebyoneclick.

SVC – A simple and patient-oriented way to achieve spontaneous breathing

Traditional Approach settings (average # of steps):

1. Switch Sync on in Pressure Control

2. Adjust trigger sensibility

3. Reduce mandatory frequency

4. Switch to Pressure Support

5. Set Apnea frequency

6. Adjust Pressure Support level

7. Reduce stepwise the pressure support

Zeus® Infinity® Empowered with SVCsetting: Encourage SB

spontaneous

breathing

time

100%

0%

Page 4: svc-br-9101773-en - Draeger

| 04

Clinical knowledge built-in

Atoolisofrealhelpwhenitisintuitiveandeasytouse.SVCwasdesignedtoorganicallyintegrateintodailyclinicalpracticegivingthecliniciantherightchoices.OncethedesiredventilationgoalissetSVC,takesovercontrolofthedependentparameterskeepingthepatientwithinprotectiveranges.

SVCcontributestothereductionofcomplexityintheanaesthesiaworkplacewhilehighventilationqualityisensured–safe,spontaneous,simple.

SmartVentilationControl(SVC)userinterfaceonZeus®Infinity®Empowered

SimpleThe Intuitive Approach to Ventilation

both

:D-2

367-

2016

Page 5: svc-br-9101773-en - Draeger

05 |

Safe–Setonetherapygoal,insteadofcontrolling severalparameters–HelpstodeployprotectiveventilationintheOR–Controlsventilationsettingsusingevidence-

basedrulesets

Spontaneous–Supportstheemergingrespiratorydriveduring

generalanaesthesiaifrequired–Ensuressmoothandindividualisedtransition

fromcontrolledventilationtocompletespontaneousbreathing

Simple–Simplifiesachievingventilationgoals–Controlsventilationparametersbasedonuser

definedventilationgoal–IntuitivelyintegratedintotheZeus®Infinity®

Empowereduserinterface

You make the therapy decisions – SVC assists you to get there.

Asimpleuserinterfaceallowsyoutosettheventilationgoalandtargetrangeseasily.Withlow tidal volumesandasmoothtransitionfromcontrolled ventilationtospontaneous breathing SVC –thenewventilationoptionofZeus®Infinity®Empowered– offerscuttingedgetechnologyandgreatventilationcomfort foryouandyour patient.

Your Ventilation Assistant

Rethink Ventilation in the OR

Smart Ventilation Control

Page 6: svc-br-9101773-en - Draeger

910

177

3|

16.0

8-2

|H

Q|

PP

|S

ubje

ctto

mod

ifica

tions

201

6D

räge

rwer

kA

G&

Co.

KG

aA

CORPORATE HEADQUARTERSDrägerwerkAG&Co.KGaAMoislingerAllee53–5523558Lübeck,Germany

www.draeger.com

REGION CENTRAL AND SOUTH AMERICADrägerPanamaComercialS.deR.L.ComplejoBusinessPark,Vtower,10thfloorPanamaCityTel [email protected]

CANADADraegerMedicalCanadaInc.2425SkymarkAvenue,Unit1Mississauga,Ontario,L4W4Y6Tel+19052126600Toll-free+18663432273Fax+19052126601Canada.support@draeger.com

REGION DACHDrägerwerkAG&Co.KGaAMoislingerAllee53–5523558Lübeck,GermanyTel [email protected]

REGION EUROPEDrägerwerkAG&Co.KGaAMoislingerAllee53–5523558Lübeck,GermanyTel [email protected]

REGION MIDDLE EAST, AFRICADrägerwerkAG&Co.KGaABranchOfficeP.O.Box505108Dubai,UnitedArabEmiratesTel [email protected]

REGION ASIA / PACIFICDraegerMedicalSouthEastAsiaPteLtd.25InternationalBusinessPark#04-27/29GermanCentreSingapore609916,SingaporeTel [email protected]

Manufacturer:DrägerwerkAG&Co.KGaAMoislingerAllee53–5523558Lübeck,Germany

Locate your Regional Sales Representative at: www.draeger.com/contact