survivor 9 led [sur9l] selux · round up to the nearest foot and replace the “xx” with the...
TRANSCRIPT
Page 1 of 8(Rev. 09/2017)
SUR9L_ss_[1B]v2.5 In a continuing eff ort to off er the best product possible, we reserve the right to change, without notice, specifi cations or materials that in our opinion will not alter the function of the product. Specifi cation sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Project:
Type: Qty:
Date: Customer:
Survivor® 9 LED
Order Code:
Custom colors are available, Please consult factory
EmergencyOptions
EC14
Emergency Circuit Wiring
14 See page for full details and restrictions
FS12
Single FusingNC13
Nipple Connector (for Runs)
FixtureOptions
12 Not available with 347V or 480V13 Required for Runs
TRTamper Resistant Door Screws
EMRRemote Micro Inverter (consult factory)
EFCEnd Feed for 1/2” conduit
NFNatatorium Finish(consult factory)
Series SUR9LSurvivor® 9 LED
Light Engine
CCT 272700K
Shielding PC Polycarbonate Prismatic Satine Lens
LI Polycarboate Prismatic Satine Lens with LED optimized inlay
Mounting FSurface Mount
V3
Vertical Wall Mount Mount
RS4
Rigid Stem Mount
NominalLength
022 ft.
044 ft.
033 ft.
XX8
Run, available in 2’, 3’ or 4’ nominal increments. Round up to the nearest foot and replace the “XX” with the footage (i.e. 16 for 16’)
Finish WHWhite
BKBlack
SVSilver
SPSpecify Premium Color
Voltage
SUR9L
Feed Location
RF5
Right FeedLF5
Left FeedVF6
Vertical Feed (feed at bottom)
BF Back Feed
EL End Feed Left (for conduit)
ER End Feed Right (for conduit)
BZBronze
5 F mounting only. 6 V mounting only.
303000K
353500K
404000K
ED7
End Feed both sides (for conduit daisy chain)
- - - - - - - - -SUR9L
7 Fixture not rated for use as a raceway.
8 Requires “NC” option.
LED WARRANTY
5YEAR
1 Values calculated from a 4’ fi xture @4000K using DIM driver.
2 Not available with Lutron
1B351
843lm/9.1Wper foot
1B301
720lm/7.6Wper foot
1B251
646lm/6.8Wper foot
1B201
487lm/5.0Wper foot
1B451,2,
1060lm/11.7Wper foot
1B401,2
958lm/10.4Wper foot
2B351
1680lm/18.4Wper foot
2B301
1436lm/15.4Wper foot
2B251
1287lm/13.6Wper foot
2B201
971lm/10.2Wper foot
2B451,2,
2113lm/23.6Wper foot
2B401,2
1910lm/21.0Wper foot
3 No hinges included4 No Feed Location Required
ARRA Compliant
ADA Compliant
UNV120 thru 27750/60hz capable
3479
347 Volt4809
480 Volt
9 Available only with 1B35 and 2B35 light engines, using DIM, DIL, and DC3 drivers.
DIL0-10V(Logarithmic)
Driver DEDeldoLED ECOdrive DALI (Logarithmic)
DCE10
Lutron Eco-System
DC310
Lutron 3-WireDC2Lutron 2-Wire 11 For use with external sensors, by others
DIM0-10V(Linear)
SR11
Philips Xitanium SR (DALI)
DC5Lutron 5-Series (consult factory)
10 Available only for 1B35
*Not required for RS mounting
- -
Page 2 of 8 (Rev. 09/2017)
SUR9L_ss_[1B]v2.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Survivor® 9 LED
Construction:
Housing - Low profile marine-grade, extruded aluminum housing with low-copper, die cast aluminum end caps and stainless steel mounting brackets. Designed for indoor and outdoor wall and ceiling mount applications as well as light to medium security areas. Mounting hardware by others.
Geartray - Gear tray installs as complete elec-trical unit secured with a spring clip assembly fully accessible from below ceiling. White finish for even illumination.
Shielding - Vandal and impact resistant .156” thick polycarbonate prismatic satine lens (IK10, NRTL, & IP66 wet label certificate ratings).
One piece Silicone Gasketing - Fixture lens and end plates are fully gasketed (IP66 rated) for weather proofing, dust, and insect control.
Hinged Lens Door - Door hinges down on sur-face and rigid stem mount versions for easy ac-cess to lamp(s) and driver. Hinges are replaced with safety cable for Vertical Wall Mounting. After door is open, hinges can be released via a quick disconnect mechanism for easy mount-ing of housing. Door seals securely with two (2) vandal resistant stainless steel captive fasteners when TR option is selected.
Feed Location - (not required for RS Mounting.) For Surface Mount (F), specify Left (LF) or Right (RF) side for power feed entry. For Vertical Wall Mount (V), Feed Loca-tion is availalable with Vertical Feed (VF) or Back Feed (BF). For mounting over junction box, please specify (BF) option and see page 3 for details. Consult factory for middle fixtures to be con-nected in a linear row with nipple connector.
Nipple Connector - (not shown) 3/8” IP nipple connector for water tight connection between luminaires in a run. Two connectors required per connection. Not required when MT is used.
Weight - 2 ft - 12 lbs., 3ft - 18 lbs., 4ft - 24 lbs.
Electrical/Performance:
LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 96% at 25,000 hours and 93% at 60,000 hours for 1B light engine and 96% at 25,000 hours and 93% at 60,000 hours for 2B light engine @ 25ºC per TM-21 reports. Reported L70 greater than 60,000 hours.
Delivered Lumens - Due to LED manufacturer’s tolerances the listed output has a ±5% tolerance. For outputs based on different shielding or CCT please see photometry section at the end.
CCT - Available in 2700K, 3000K, 3500K and 4000K, tolerance within a 3-step MacAdam el-lipse.
CRI - Min. 90.
All Drivers - High efficiency, constant current, soft start, Electronic Class 2 with a PFC > 0.90. For more detailed information on the available drivers please see page 7.
Sensors - Selux offers a variety of integral sensor options. For details and specifications, please refer to page 9.
Thermal Performance:
Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of 35° C (95° F) for all drivers.
Luminaires are suitable for minimum ambient temperatures of:-40ºC (-40ºF) for DIM, DM, DML, and DMD drivers.-20ºC (-4ºF) for SR drivers.0ºC (32ºF) for DC2, DC3, and DCE drivers.
Luminaire Finish:
Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI.
All products undergo a five stage intensive pre-treatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and hu-midity resistance as well as ultra violet resistance for color retention.
Standard interior colors are White (WH), Black (BK), Bronze (BZ), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide.
Warranty:
5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the Survivor® 9 LED’s assem-bly shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed ac-cording to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see “Selux Terms and Condition of Sale.”
Certifications and Compliance: NRTL - For Wet location (I.E. cULus; cCSAus)ARRA CompliantRoHS Compliant
2 13/16” (71mm)
9 1/2” (240mm)
Surface Mount (F) Rigid Stem (RS)Vertical Wall Mount (V)
Page 3 of 8 (Rev. 09/2017)
SUR9L_ss_[1B]v2.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Surface Mount Right/Left/Vertical Feed
Front View (w/o cover/geartray shown)
Electical Box (by others)
1 7/16” (36 mm)
Overall LengthSurvivor® 9 LED Surface Mount
1L35 or 2L35
Overall Length Mounting Length
2’ individual
3’ individual
4’ individual
For mounting over a juction box. Suggested mounting with hinges on bottom edge of fixture. Please note: for vertical mounting, the feed is on the
bottom and hinge is replaced by stainless steel safety cable. Mounting hardware by others. Outlet box by others.
27 3/16” (690mm)
39 13/16” (995mm)
51 3/16” (1300mm)
25 5/8” (651mm)
37 5/8” (956mm)
49 5/8” (1261mm)
Side View
For other lengths, lamping, continuous runs or configurations, please specify overall length (in feet), accessories desired and sketch/drawing of configuration. Selux will detail project drawings upon order and supply submittal drawings for approval. Individual fixtures cannot be field joined without NC option. If you have any questions please contact Selux customer service or applica-tions engineering for assistance (1-800-SELUX-CS).
Survivor® 9 LED
Top View
Front Closed View
9 1/2” (240 mm)
Left Feed Location (LF) Feed cord provided equivalent to length of fixture.
Feed Hole
Feed Cable
Electical Box (by others)
Driver Hinged Edge (Horizontal mountings only)
Mounting Length
6 22/32” (170 mm)
(4x) Clearance holes for up to 1/4” (6mm) mounting hardware (by others)
Feed Cord in Right Feed Location (RF). Cord run through channel in back of housing.
Survivor® 9 LED Surface Mount 1L35 or 2L35
Overall Length Mounting Length
2’ individual
3’ individual
4’ individual
27 3/16” (690mm)
39 13/16” (995mm)
51 3/16” (1300mm)
25 5/8” (651mm)
37 5/8” (956mm)
49 5/8” (1261mm)
Surface Mount / Vertical Mount Back FeedFor mounting to a juction box. Suggested mounting with hinges on bottom edge of fixture. Mounting hardware by others. Outlet box by others.
IMPORTANT! Feed Hole is not centered. J-Box by others must be offset accordingly.
Front View (w/o cover/geartray shown)
Electical Box (by others)
3/4” (19.5mm)
1 7/16” (36 mm)
Overall LengthSide View
Top View
Front Closed View
9 1/2” (240 mm)
Electical Box (by others)
DriverHinged Edge of Housing
(Horizontal mountings only)
Mounting Length3/4” (19.5 mm)1 3/8” (35mm)
6 22/32” (170 mm)
(4x) Clearance holes for up to 1/4” (6mm) mounting hardware (by others)
1 7/8” (47.6mm)
13/16” (21mm) Feed Hole suitable for 1/2” (13mm) chase nipple (by others) for water-tight connection to J-Box
4” (101.6 mm)
Electical Box (by others)
Electical Box (by others)
Page 4 of 8 (Rev. 09/2017)
SUR9L_ss_[1B]v2.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Rigid Stem Mount
Side View
Suspension Points
with 5/8” powder coated steel pipe, threaded on both ends.
Survivor® 9 LED
Survivor® 9 LED Rigid Stem Mount 1L35 or 2L35
Overall Length Suspension Points
2’ individual
3’ individual
4’ individual
27 3/16” (690mm)
39 13/16” (995mm)
51 3/16” (1300mm)
25 5/8” (651mm)
37 5/8” (956mm)
49 5/8” (1261mm)
4’ (
1219
mm
)Hei
gh
t
Feed
Suspension Hickey
Hex Nut
Canopy Securing Collar
1/4” x 5” Diameter Canopy (White)
3/8 I.P. Nipple (supplied and installed by others)
Outlet Box(supplied and installed by others)
Dress Nut
3/4” Diameter Steel Stem (White)
Hex Nut
Rigid Stem (RS) Suspension Detail6 ft. of feed cord pre-attached to luminaire
Page 5 of 8 (Rev. 09/2017)
SUR9L_ss_[1B]v2.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Survivor® 9 LED
Wiring Diagrams
Driver Quantity
2 ft. 3 ft. 4 ft. RUN
DIM, DIL, DED, and SR drivers 1 1 1 Approximately 1 driver per 4 ft.
DC2, DC3, DCE, and DC5 drivers 1 1 1 Consult Factory
Drivers:
standard0-10V linear (DIM) 0-10V linear eldoLED SOLOdrive (DM)0-10V logarithmic eldoLED SOLOdrive (DML)DALI eldoLED SOLOdrive (DMD)Philips SR DALI (SR)
DIM, DM, DML, DMD & SR
DALIDALI
DCE & DC5
Lutron EcoSystem 5-Series (DC5)
0-10V linear dimming (DIM)Luminaires supplied with drivers offering the capability of either normal switched operation or 0-10V dimming for linear dimming curve. Fixtures ship wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to 1%.
eldoLED SOLOdrive 0-10V linear dimming (DM)Luminaires supplied with SOLOdrive 0-10V dimming driver for linear dim-ming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.
eldoLED SOLOdrive 0-10V logarithmic dimming (DML)Luminaires supplied with SOLOdrive 0-10V dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.
eldoLED SOLOdrive DALI dimming (DMD)Luminaires supplied with SOLOdrive DALI dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.
* For control recommendations for eldoLED drivers, please consult eldoLED.
LUTRON 2-wire dimming (DC2)Luminaires supplied with Hi-lume 2-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%.
LUTRON 3-wire dimming (DC3)Luminaires supplied with Hi-lume 3-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%.
LUTRON EcoSystem dimming (DCE)Luminaires supplied with Hi-lume EcoSystem (4 wire, digital link) dim-ming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%.
LUTRON EcoSystem 5-Series dimming (DC5)Luminaires supplied with EcoSystem 5-Series dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 5%.
* For control recommendations and system layout for Lutron drivers, please contact Lutron.
Philips Xitanium Sensor Ready DALI dimming (SR)Luminaires supplied with Xitanium SR dimming driver programmed for Constant Current Reduction (CCR). Minimum dimming level down to 5%. For use with E and P sensors only.
*For inrush and control current, please refer to the driver manufacturers’ spec sheets.
Page 6 of 8(Rev. 09/2017)
SUR9L_ss_[1B]v2.5
In a continuing eff ort to off er the best product possible, we reserve the right to change, without notice, specifi cations or materials that in our opinion will not alter the function of the product. Specifi cation sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Typical Spacing for Runs
For other lengths, lamping, continuous runs or confi gurations, please specify overall length (in feet), accessories desired and sketch/drawing of confi guration. Selux will detail project drawings upon order and supply submittal drawings for approval. Individual fi xtures cannot be fi eld joined. If you have any questions please contact Selux customer service or ap-plications engineering for assistance (1-800-SELUX-CS).
Survivor® 9 LED
Water-tight Threaded Nipple supplied by manufacturer withlock-nuts.
1/8” (3mm)gap (minimum)
Create Run by adding individual luminaires with NC option. If diff erent lengths are chosen, the shortest housing is placed at
the end. For example: for an 11ft run, the following length luminaires would be used 4ft - 4ft - 3ft
Connector Assembly Detail with Hex Nuts, Connector and O rings.
Conduit Connector
Used with the EL/ER/ED feed options. For 1/2” conduit (by others) only.
OptionsOptions
Fusing, fi xture(s) supplied with an in-line fuse (up to 277v) located on the hot wire for each feed. (Min. 3amp to a Max. 6amp slow burn fuse).
Tamper Resistant option (TR) uses tamper resistance assembly and door screws.
Single Fusing Tamper Resistance
Connector Assembly Detail with Hex Nut, O ring and Connector.
Page 7 of 8 (Rev. 09/2017)
SUR9L_ss_[1B]v2.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Photometry
LI /4000K CCT
PC /4000K CCT
Survivor® 9 LED
329
657
986
1314
1
2
Maximum Candela = 1314 Located At Horizontal Angle = 22.5, Vertical Angle = .5# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)
Catalog #: SUR9L-1B35-40-LI-X-04-XX-UNVReport #: 11686571.01 Delievered Lumens: 3372 Input Watts: 36.52WEfficacy: 92 Power Factor: 0.996 Total Harmonic Distortion: 3.43 CCT: 3940KCRI: 96.2 Max Candela: 1314 @ .5° from VerticalSpacing Criterion (0-180): 1.16 Spacing Criterion (90-270): 1.22 Spacing Criterion (Diagonal): 1.28
346
691
1037
1382
1
2
Maximum Candela = 1382 Located At Horizontal Angle = 22.5, Vertical Angle = .5# 1 - Vertical Plane Through Horizontal Angles (90 - 270)# 2 - Vertical Plane Through Horizontal Angles (0 - 180)
Catalog #: SUR9L-1B35-40-PC-X-04-XX-UNVReport #: 11686571.07 Delievered Lumens: 3702 Input Watts: 36.45WEfficacy: 102 Power Factor: 0.996 Total Harmonic Distortion: 3.43 CCT: 3940KCRI: 96.2 Max Candela: 1382 @ .5° from VerticalSpacing Criterion (0-180): 1.20 Spacing Criterion (90-270): 1.24 Spacing Criterion (Diagonal): 1.32
Page 8 of 8 (Rev. 09/2017)
SUR9L_ss_[1B]v2.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Survivor® 9 LED
Photometry
CCT and CRI multipliers apply to the photometry, IES files, and per foot values listed on page one (light engine).
Light engine multiplier supplied for per foot values listed on page one (light engine).
4000K3500K3000K2700K
Light Engine Lumens Wattages1B45 1.258 1.2851B40 1.137 1.1401B35 1.000 1.0001B30 0.855 0.8381B25 0.766 0.7401B20 0.578 0.5522B45 2.506 2.5892B40 2.266 2.2962B35 1.993 2.0152B30 1.703 1.6872B25 1.526 1.4902B20 1.151 1.112
LIPC
Lens Multiplier1.0001.098
SUR9L LED Direct Photometry Multiplier Table
CCT Multiplier
Light Engine Multiplier
1.0000.9720.9630.931