superlite 400 forensic light source

25
Arrowhead Forensics 913-894-8388 SUPERLITE 400 Forensic Light Source

Upload: elijah

Post on 03-Feb-2016

80 views

Category:

Documents


3 download

DESCRIPTION

SUPERLITE 400 Forensic Light Source. Arrowhead Forensics 913-894-8388. Mobile Forensic Light Source. SUPERLITE 400. • LUMATEC • SUPERLITE 400 • Spectral Facts • Trail Identification. [Folie 04 von 36]. The Designing of the SUPERLITE 400. Cooperation with German Police - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: SUPERLITE 400 Forensic Light Source

ArrowheadForensics

913-894-8388

SUPERLITE 400Forensic Light Source

Page 2: SUPERLITE 400 Forensic Light Source

[Folie 04 von 36]

Mobile Forensic Light Source

SUPERLITE 400

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 3: SUPERLITE 400 Forensic Light Source

[Folie 05 von 36]

The Designing of the SUPERLITE 400

• Cooperation with German Police

• Developed by police detectives

high mobility

low weight

optimum functionality

ease of use

flexible operations

safety

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 4: SUPERLITE 400 Forensic Light Source

[Folie 06 von 36]

SUPERLITE 400 in Detail - Front View

Telescope arm withlightguide clip

Intensity control

Filter selection

Battery pack with LED charge indicator

Light guide socket• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 5: SUPERLITE 400 Forensic Light Source

[Folie 07 von 36]

SUPERLITE 400 in Detail - Rear View

Charger with caradapter cable

Key operatedsafety switch

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 6: SUPERLITE 400 Forensic Light Source

[Folie 08 von 36]

SUPERLITE 400 in Detail - Light Guide Handle

Collimator

Safety bracket

Sliding switch

Handle

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 7: SUPERLITE 400 Forensic Light Source

[Folie 09 von 36]

SUPERLITE 400 in Detail - Line Illuminator

Inspection of flooringi.e. detection of foot prints

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 8: SUPERLITE 400 Forensic Light Source

[Folie 18 von 36]

Comparison of Lamp Efficiency

By employing a superpressure lamp the efficiency is enhanced by a factor of 4.

Battery operation becomes possible.

Lightweight and compact design.

*Optimum performance in forensic spectrum (320-700nm)

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 9: SUPERLITE 400 Forensic Light Source

[Folie 19 von 36]

Fluorescence Observation - Schematic Diagram

Fluorescence

Specimen

Light source

Stray light

Camera

Excitation filter(Bandpass)

Observation filter(Longpass)

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 10: SUPERLITE 400 Forensic Light Source

[Folie 20 von 36]

SUPERLITE 400 - The Spectra and Their Applications

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

No. Spectrum Power Goggles Application

0400-700nm

white10,0W

Transparent(UV protection)

General search(footprints)

1320-500nmUVA+blue

6,6W Orange General search

2400-500nm

blue5,5W Orange

General search, sperm, urine, fibers,etc.

3320-400nm

UVA1,8W

Transparent(UV protection)

General search, stains, fingerprints,textile fibers, body fluids

none Fingertrails in blood, blood4415nmviolet

1,9W

Yellow/Orange Sperm, gun residuals

5440nm

blue2,1W Yellow/Orange

Sperm, fingerprints treated withfluorescing powder

6460nm

blue2,0W Orange

Fingerprints (Cyanoacrylate – Ardrox orCyanoacrylate DFO)

7490nm

turquoise1,3W Orange

Fingerprints (Cyanoacrylate – Ninhydrinor Cyanoacrylate Rhodamin 6G)

8550nmgreen

1,4W OrangeFingerprints treated with DFO, reductionof background fluorescence

9570nm

green-yellow2,2W Red

Fingerprints treated with Ninhydrin,reduction of background fluorescence

Page 11: SUPERLITE 400 Forensic Light Source

Störende Untergrundfluoreszenz

Minimierung d. Untergrundfluoreszenz durch geeignete Auswahl von Anregungs- und Beobachtungsfilter

[Folie 21 von 36]

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 12: SUPERLITE 400 Forensic Light Source

Bedeutung der Filterqualität

[Folie 22 von 36]

gute Resultate bei der Spurensuche sind nur mit hochwertigen Filtern erreichbar

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 13: SUPERLITE 400 Forensic Light Source

[Folie 23 von 36]

Examples of Trails (1)

• Fingerprints brushed with fluorescing powder• Substrate: Aluminium• Excitation: UVA + Blue (320-500nm)• Observation: Longpass filter (orange)

Greenwop Redwop

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 14: SUPERLITE 400 Forensic Light Source

[Folie 24 von 36]

Examples of Trails (2)

• Fingerprints after fuming with cyanoacrylate and

dying with fluorescence agent• Substrate : Plastic foil (coloured)• Excitation : UVA (320-400nm)• Observation : Longpass filter (orange)

ARDROX

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 15: SUPERLITE 400 Forensic Light Source

Transmission spectrum ARDROX

[Folie 25 von 36]

Absorption maximum between 320 and 400nm

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 16: SUPERLITE 400 Forensic Light Source

[Folie 26 von 36]

Examples of Trails (3)

• Fingerprints after fuming with cyanoacrylate and

dying with fluorescence agent• Substrate: Plastic foil (coloured)• Excitation: 460nm• Observation: Longpass filter (orange)

Basic Yellow

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 17: SUPERLITE 400 Forensic Light Source

Transmission spectrum Basic Yellow

[Folie 27 von 36]

Absorption maximum at 460nm

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 18: SUPERLITE 400 Forensic Light Source

[Folie 28 von 36]

Examples of Trails (4)

• Fingerprints after fuming with cyanoacrylate and

dying with fluorescence agent• Substrate: Plastic foil (coloured)• Excitation: 490nm• Observation: Longpass filter (orange)

Basic Red

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 19: SUPERLITE 400 Forensic Light Source

Transmission spectrum of Basic Red

[Folie 29 von 36]

Absorption maximum at 490nm

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 20: SUPERLITE 400 Forensic Light Source

[Folie 30 von 36]

Examples of Trails (5)

• Fingerprints after fuming with cyanoacrylate and

dying with fluorescence agent• Substrate: Paper (white)• Excitation: 460nm• Observation: Longpass filter (orange)

DFO

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 21: SUPERLITE 400 Forensic Light Source

Transmission spectrum of DFO

[Folie 31 von 36]

high absorbance at 460 nm with good reduction of background fluorescence

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 22: SUPERLITE 400 Forensic Light Source

[Folie 32 von 36]

Example: Proof of human fluids (1)

• Highly diluted blood trails• Substrate: Carpet (grey)• Excitation: 415nm• Observation: Longpass filter (orange)

Blood trails in white light Blood trails at 415nm

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 23: SUPERLITE 400 Forensic Light Source

[Folie 33 von 36]

Verifying of blood trails - Porphyrin Verification

Sulfuric acid (H2SO4) and bloodreact to Porphyrin

Porphyrin fluoresces withexcitation at 406nm

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 24: SUPERLITE 400 Forensic Light Source

[Folie 34 von 36]

Example: Proof of human fluids (2)

• Saliva trails• Substrate: Metal cabinet (blue)• Excitation: UVA + Blue (320-500nm)• Observation: Longpass filter (orange)

Saliva in white light Saliva in UVA + blue

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification

Page 25: SUPERLITE 400 Forensic Light Source

[Folie 35 von 36]

Example: Proof of human fluids (3)

• Sperm trails• Substrate: Carpet (grey)• Excitation: UVA (320-400nm)• Observation: Longpass filter (orange)

Sperm in white light Sperm under UVA

• LUMATEC

• SUPERLITE 400

• Spectral Facts

• Trail Identification