superline & implantium - american dental · pdf filesuperline characteristics superline...

68
SuperLine & Implantium Product Catalog

Upload: phungmien

Post on 05-Mar-2018

264 views

Category:

Documents


10 download

TRANSCRIPT

Page 1: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

SuperLine & ImplantiumProduct Catalog

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 2

Page 2: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

®™SuperLine & Implantium

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 3

Page 3: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

IntroductionS.L.A. Surface 04SuperLine Characteristics 06SuperLine Color Coding by Diameter 08SuperLine Fixture 09IMPLANTIUM Characteristics 12IMPLANTIUM Color Coding by Diameter 14IMPLANTIUM Fixture 15

Surgical ComponentsCover Screw 16Healing Abutment 17

Prosthetic Procedure 1Dual / Combi Abutment - Abutment Level Impression 18Combi Abutment 19Dual Abutment [Hex] 20Dual Abutment [Non-hex] 21Abutment Level Impression Components 22Restorative Kit 23

Prosthetic Procedure 2Dual / Dual Milling / Angled / Direct-Casting / Metal-Casting / Temporary (Plastic & Ti) Abutment - Fixture Level Impression 24Fixture Level Impression Components 25Dual Milling Abutment [Ti-G4] 27Dual Milling Abutment [Ti-G2] 29Angled Abutment [Ti-G4 / 15°] 31Angled Abutment [Ti-G4 / 25°] 32Angled Abutment [Ti-G2 / 15°] 33Angled Abutment [Ti-G2 / 25°] 34

Direct-Casting Abutment 35Metal-Casting Abutment 35Temporary Abutment 36

Prosthetic Procedure 3Screw Abutment - Abutment Level Impression 37Screw Abutment 38Screw Abutment Impression Components 39

Prosthetic Procedure 4Overdenture Procedure - Positioner / Ball / Magnetic Attachment 42Ball Attachment 43

Instruments Surgical Kit (Full) 44Drill Stopper Kit 45Drill 46Stopper 49Instrument 50DASK 53Sinus Bur Kit / Sinus Kit 54DASK / Sinus Bur Kit / Sinus Kit 55Osteotome Kit 56Trephine Kit 57Prosthetic Kit 58Planning Kit 59Prosthetic and Laboratory Instrument 60Help Kit 62Surgical Maintenance 63DASK Maintenance 64

Contents

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 4

Page 4: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

SuperLine & Implantium Product Catalog

S.L.A. Surface04

S.L.A. (Sandblasting with Large grit and Acid etching)

Reference: Kim H., et. al. “The Biocompatibility of S.L.A.-treated titanium implants.”

Biomed. Mater. 2008; 3(2): 025011.

Human Osteoblast

Figure 2. SEM topography of S.L.A. surface.

1250X

3000X

In vivo test

Implant (S.L.A.)

100x 40x

Figure 1. Histological image of new bone apposition over the implant surface at four weeks.

Bone

(A)

(B)

Bone Bone

Implant (S.L.A.)

(A) (B)

3000X

Figure 3. SEM image of human osteoblasts on S.L.A. surfaceafter 7 days of cell culture.

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 5

Page 5: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 6

Page 6: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

SuperLine Characteristics

"Immediate Implantation with Excellent Bone Response"

• Higher stabilization in extraction socket• Early loading in upper posterior• Harmony with anatomy• Sharp & fast insertion

PlatformØ

BodyØ

AbutmentG/H

Fixt

ure

Leng

th

Bevel

AbutmentØ

Abu

tmen

t Hei

ght

Selection GuidelineIdeal emergence profile for each tooth

Platform

Platform

SuperLine & Implantium Product Catalog06

A

D

B

C

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 7

Page 7: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

SuperLine Characteristics

SuperLine & Implantium Product Catalog 07

B

• The conical hex connection between implant andabutment interface ensures hermetic sealing.

• The biologic connection distributes the load to thefixture evenly. Therefore it helps minimizemicro-movement and marginal bone loss.

• All implant diameters share the same internal hex.

Biological Connection

• Increased thread height helps increase the initial stability.

• Double thread may decrease the chair time of implantation

Double Thread & Thread Height

E Single Prosthetic Platform with

variety of prosthesis

• One abutment screw fits all abutments and fixture platforms.

• Single Abutment Connection is used for all implant diameters.

• One hex screw driver fits all abutment screws.• The greater distance betweenthe threads may promote earlyosseointegration

Osseointegration

Dual Milling Angled Direct Screw

A Tapered Design

• Tapered load distribution may achieve excellentbone response.

• Tapered design may harmonize with surroundingbone anatomically.

• The large surface area helps provide excellent initialstability with sinus augmentation.

C

D

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 8

Page 8: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

SuperLine Color Coding by Diameter

Color Coding by Diameter

Cap Color

FixtureSuperLine

FixturePlatformDiameter

Unit: mm

Platform

• Cover screw is included.

FixtureBody

Diameter

Body

Yellow Green Blue Red Orange Violet

3.6 4.0 4.5 5.0 6.0 7.0

3.4 3.8 4.3 4.8 4.8 5.8

0.15 0.2 0.4 0.6 0.7 1.0FixtureBevelHeight

Bevel

SuperLine & Implantium Product Catalog08

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 9

Page 9: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

SuperLine FixtureUnit: mm

Scale 1 : 1.5 / mm

3.6

L

3.4

4.0

L

3.8

08 10 12 144.5

L

4.3

5.0

L

4.8

L REF

8 FX 45 08 SWC

10 FX 45 10 SWC

12 FX 45 12 SWC

14 FX 45 14 SWC

L REF

8 FX 50 08 SWC

10 FX 50 10 SWC

12 FX 50 12 SWC

14 FX 50 14 SWC

08 10 12 14

08 10 12 14

08 10 12 14

L REF

8 FX 40 08 SWC

10 FX 40 10 SWC

12 FX 40 12 SWC

14 FX 40 14 SWC

Platform 3.6 | Body 3.4

L REF

8 FX 36 08 SWC

10 FX 36 10 SWC

12 FX 36 12 SWC

14 FX 36 14 SWC

0.6

0.4

0.2

0.15

• Cover screw is included.

Platform 4.0 | Body 3.8

Platform 4.5 | Body 4.3

Platform 5.0 | Body 4.8

Note : To prevent damage to the implant driver or fixture, do not over torque during fixture insertion.

SuperLine & Implantium Product Catalog 09

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 10

Page 10: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

SuperLine FixtureUnit: mm

Scale 1 : 1.5 / mm

7.0

L

5.8

L

4.8

6.008 10 12

08 10 12

L REF

8 FX 60 08 SWC

10 FX 60 10 SWC

12 FX 60 12 SWC

L REF

8 FX 70 08 SWC

10 FX 70 10 SWC

12 FX 70 12 SWC

4.5

G/H 3.0H 5.0

HAB453050L and FX4510SWCCS38 and FX4510SWC

4.5

3.4

0.7

1.0

• Cover screw is included.

Platform 6.0 | Body 4.8

Platform 7.0 | Body 5.8

Note : To prevent damage to the implant driver or fixture, do not over torque during fixture insertion.

SuperLine & Implantium Product Catalog10

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 11

Page 11: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

®

Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 12

Page 12: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

3.6 3.6

3.6

4.5

4.5 4.5

4.54.0

4.0

4.0

4.0 4.0 4.0

4.0

Implantium Characteristics

C

D

Platform

BodyØ

Final DrillØ

Neck

Bevel

AbutmentG/H

Abu

tmen

t Hei

ght

Fixt

ure

Leng

th

3

MaximumReduction Line

Abutment

F

A

G

H

B

E

Selection GuidelineIdeal emergence profile for each tooth

Platform

Platform

SuperLine & Implantium Product Catalog12

Product Catalog Final 2012_Layout 1 9/11/12 9:17 AM Page 13

Page 13: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Abutment TiN-Coating

• Esthetic gold color with TiN-coating.

Flat End

• The flat end design reduces bone perforation risk.

Cutting Edge

• The 3 blade self tapping design minimizes bone destruction.

• Tapered apical shape promotes easier insertion.

Implantium Characteristics

F

HG

C Biological Connection

• The conical hex connection between implant and abutmentinterface ensures hermetic sealing.

• The biologic connection distributes the load to the fixtureevenly. Therefore it helps minimize micro-movement andmarginal bone loss.

• All implant diameters share the same internal hex.

Bacteria Resistant Bevel

• The tapered bevel platform design may make boneprofiling unnecessary at 1st, 2nd surgery.

Biological Thread

• Thread platform design creates excellent bone toimplant contact.

• Threads engage and penetrate bone with ease.

A Optimal Fixation Threads

• Synchronized positive neck threads.

• Initial stability & maximum sealing between the corticalbone and fixture.

• Optimal fixation threads reduce stress of marginalcortical bone and minimize marginal bone loss.

Regular Platform

E

B

D

Dual Milling Angled Direct Screw

Single Prosthetic Platform with

variety of prosthesis

• One abutment screw fits all abutments and fixture platforms.

• Single Abutment Connection is used for all implant diameters.

• One hex screw driver fits all abutment screws.

2.3

2.0

SuperLine & Implantium Product Catalog 13

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 14

Page 14: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Implantium Color Coding by Diameter

Color Coding by Diameter

Cap Color

FixtureImplantium

(Mount Free)

FixturePlatformDiameter

Platform

FixtureBody

Diameter

Body

Yellow Green Blue Red

3.6 4.0 4.5 5.0

3.4 3.8 4.3 4.8

FixtureBevelHeight

Bevel

0.15 0.2 0.4 0.6

Unit:mm• Cover screw is included.

SuperLine & Implantium Product Catalog14

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 15

Page 15: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Implantium FixtureUnit: mm

Scale 1 : 1.5 / mm

08 10 12 143.6

L

3.4

L REF

8 FX 34 08 MLC

10 FX 34 10 MLC

12 FX 34 12 MLC

14 FX 34 14 MLC

4.0

L

3.8

4.5

L

4.3

5.0

L

4.8

08 10 12 14 L REF

8 FX 38 08 MLC

10 FX 38 10 MLC

12 FX 38 12 MLC

14 FX 38 14 MLC

08 10 12 14 L REF

8 FX 43 08 MLC

10 FX 43 10 MLC

12 FX 43 12 MLC

14 FX 43 14 MLC

08 10 12 14 L REF

8 FX 48 08 MLC

10 FX 48 10 MLC

12 FX 48 12 MLC

14 FX 48 14 MLC

0.15

0.2

0.4

0.6

• Cover screw is included.

Note : To prevent damage to the implant driver or fixture, do not over torque during fixture insertion.

Platform 3.6 | Body 3.4

Platform 4.0 | Body 3.8

Platform 4.5 | Body 4.3

Platform 5.0 | Body 4.8

SuperLine & Implantium Product Catalog 15

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 16

Page 16: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Cover ScrewUnit: mm

Scale 1 : 1.5 / mm• Single use only.

Color : Blue / Platform 4.0, 4.5, 5.0, 5.5, 6.0, 7.0Body 3.8, 4.3, 4.8, 5.8

Type REF Smal l CS34

Type REF Regular CS38

CS38 and FX4510SWC

4.53.8

Note : Hex driver: Use no more than 5N cm torque when screwing a cover screw to a fixture. If hex is worn, slot on the head of the product can be used to rotate it.

Color : Black / Platform 3.6 / Body 3.4

SuperLine & Implantium Product Catalog16

CS34 and FX3610SWC

CS38 and FX4510SWC

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 17

Page 17: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Healing Abutment4.5

G/H 3.0H 5.0

HAB453050L and FX4510SWC

Diameter 4.0

G/H H REF

2.0 2.0 HAB 40 20 20 L

2.0 3.5 HAB 40 20 35 L

3.0 5.0 HAB 40 30 50 L

4.0 7.0 HAB 40 40 70 L

6.56.5

6.5

3.52.05.0

3.07.0

4.0

4.04.0

4.0

3.52.05.0

3.07.0

4.0

4.54.5

4.5

3.5 5.03.0

7.04.0

5.55.5

5.5

3.52.05.0

3.07.0

4.0

7.5

5.03.0

4.0

2.0

4.5

5.5

6.5

Diameter 4.5

G/H H REF

2.0 2.0 HAB 45 20 20 L

2.0 3.5 HAB 45 20 35 L

3.0 5.0 HAB 45 30 50 L

4.0 7.0 HAB 45 40 70 L

Diameter 5.5

G/H H REF

2.0 2.0 HAB 55 20 20 L

2.0 3.5 HAB 55 20 35 L

3.0 5.0 HAB 55 30 50 L

4.0 7.0 HAB 55 40 70 L

Diameter 6.5

G/H H REF

2.0 2.0 HAB 65 20 20 L

2.0 3.5 HAB 65 20 35 L

3.0 5.0 HAB 65 30 50 L

4.0 7.0 HAB 65 40 70 L

Diameter 7.5, 8.5, 9.5

G/H H REF

3.0 5.0 HAB 75 30 50 L

3.0 5.0 HAB 85 30 50 L

3.0 5.0 HAB 95 30 50 L

8.5

5.03.0

9.5

5.03.0

2.02.0

2.0

2.0

Unit: mm

Scale 1 : 1.5 / mm

Note : Hex driver: Use no more than 10N cm torque when screwing a Healing Abutment to a fixture. If hex is worn, slot on the head of the product can be used to rotate it.

• Single use only.

SuperLine & Implantium Product Catalog 17

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 18

Page 18: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Prosthetic Procedure 1

Combi / Dual Abutment

Closed Tray technique

Cemented restoration

Modification

Abutment Level Impression

Burn-out Cylinder

Dual AbutmentHex / Non-hex 4.5 / 5.5 / 6.5

Page 20, 21

Combi Abutment4.5 / 5.5 / 6.5

Page 19

Impression CopingTransfer (Snap on) 4.5 / 5.5 / 6.5

Page 22

AnalogLong 4.5 / 5.5 / 6.5Page 22

AnalogShort 4.5 / 5.5 / 6.5Page 22

BridgeRotational

4.5 / 5.5 / 6.5Page 22

SingleNon-Rotational

4.5 / 5.5 / 6.5Page 22

Impression Technique and Restoration Selection

SuperLine & Implantium Product Catalog18

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 19

Page 19: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Combi Abutment

1.0 1.5 2.5 3.5 4.5 5.5

1.5 2.5 3.5 4.5 5.5

G/H 3.5

5.5

5.5

1.5

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

G/H REF REF

1.0 CAB 45 10 L CAB 45 10 SL

1.5 CAB 45 15 L CAB 45 15 SL

2.5 CAB 45 25 L CAB 45 25 SL

3.5 CAB 45 35 L CAB 45 35 SL

4.5 CAB 45 45 L CAB 45 45 SL

5.5 CAB 45 55 L CAB 45 55 SL

Diameter 4.5

CAB5535L and FX4510SWC

G/H 3.54.0

5.5

CAB5535SL and FX4510SWC

Type

Long

Type

Short

G/H REF REF

1.5 CAB 55 15 L CAB 55 15 SL

2.5 CAB 55 25 L CAB 55 25 SL

3.5 CAB 55 35 L CAB 55 35 SL

4.5 CAB 55 45 L CAB 55 45 SL

5.5 CAB 55 55 L CAB 55 55 SL

Diameter 5.5

Type

Long

Type

Short

1.5 2.5 3.5 4.5 5.5

G/H REF REF

1.5 CAB 65 15 L CAB 65 15 SL

2.5 CAB 65 25 L CAB 65 25 SL

3.5 CAB 65 35 L CAB 65 35 SL

4.5 CAB 65 45 L CAB 65 45 SL

5.5 CAB 65 55 L CAB 65 55 SL

Diameter 6.5

Type

Long

Type

Short

G/H

G/H

G/H

5.5

4.0

G/H

G/H

5.5

4.0

G/H

G/H

5.5

4.0

G/H

G/H

Unit: mm

Scale 1 : 1.5 / mm

SuperLine & Implantium Product Catalog 19

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 20

Page 20: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Dual Abutment [Hex]

G/H 3.5

5.5

5.5

1.5

G/H REF

1.0 DAB 45 10 HL

1.5 DAB 45 15 HL

2.5 DAB 45 25 HL

3.5 DAB 45 35 HL

4.5 DAB 45 45 HL

5.5 DAB 45 55 HL

1.0 1.5 2.5 3.5 4.5 5.5

Diameter 4.5 I Hex

G/H REF

1.5 DAB 55 15 HL

2.5 DAB 55 25 HL

3.5 DAB 55 35 HL

4.5 DAB 55 45 HL

5.5 DAB 55 55 HL

1.5 2.5 3.5 4.5 5.5Diameter 5.5 I Hex

DAB5535HL and FX4510SWC

G/H REF

1.5 DAB 65 15 HL

2.5 DAB 65 25 HL

3.5 DAB 65 35 HL

4.5 DAB 65 45 HL

5.5 DAB 65 55 HL

1.5 2.5 3.5 4.5 5.5Diameter 6.5 I Hex

G/H

G/H

G/H

G/H

5.5

G/H

5.5

G/H

5.5

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

SuperLine & Implantium Product Catalog20

2.3

2.0

2.3

2.0

2.3

2.0

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 21

Page 21: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Dual Abutment [Non-Hex]

G/H 3.5

5.5

5.5

1.5

G/H REF

1.0 DAB 45 10 NL

1.5 DAB 45 15 NL

2.5 DAB 45 25 NL

3.5 DAB 45 35 NL

4.5 DAB 45 45 NL

5.5 DAB 45 55 NL

1.0 1.5 2.5 3.5 4.5 5.5

Diameter 4.5 I Non-hex

G/H REF

1.5 DAB 55 15 NL

2.5 DAB 55 25 NL

3.5 DAB 55 35 NL

4.5 DAB 55 45 NL

5.5 DAB 55 55 NL

1.5 2.5 3.5 4.5 5.5

Diameter 5.5 I Non-hex

DAB5535NL and FX4510SWC

G/H REF

1.5 DAB 65 15 NL

2.5 DAB 65 25 NL

3.5 DAB 65 35 NL

4.5 DAB 65 45 NL

5.5 DAB 65 55 NL

1.5 2.5 3.5 4.5 5.5Diameter 6.5 I Non-hex

G/H

G/H

G/H

G/H

5.5

G/H

5.5

G/H

5.5

2.3

2.0

2.3

2.0

2.3

2.0

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

SuperLine & Implantium Product Catalog 21

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 22

Page 22: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Abutment Level Impression Components

Diameter REF

4.5 CCC 45 L

5.5 CCC 55 L

6.5 CCC 65 L

4.5 5.5 6.5

Comfort Cap

4.5 5.5 6.5 Diameter REF

4.5 CIC 45 L

5.5 CIC 55 L

6.5 CIC 65 L

Impression Coping

Comfort Cap | Snap on

6.7

4.5 5.5 6.5

4.8

Type Diameter REF

4.5 CCC 45 CS

Short 5.5 CCC 55 CS

6.5 CCC 65 CS

4.5 CCC 45 C

Long 5.5 CCC 55 C

6.5 CCC 65 C

6.8

10.4

Lab Analog

Type Diameter REF

4.5 CAN 45 SL

Short 5.5 CAN 55 SL

6.5 CAN 65 SL

4.5 CAN 45 LL

Long 5.5 CAN 55 LL

6.5 CAN 65 LL

Burn-out Cylinder

Type Diameter REF

4.5 CBC 45 SL

Single 5.5 CBC 55 SL

6.5 CBC 65 SL

4.5 CBC 45 BL

Bridge 5.5 CBC 55 BL

6.5 CBC 65 BL

4.5 5.5 6.5

4.0

12.0

5.5

12.0

4.5 5.5 6.5

12.8

12.8

Abutment Screw ASC 2045

Unit: mm

Scale 1 : 1 / mm

10.2

SuperLine & Implantium Product Catalog22

2.3

2.0

REF

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 23

Page 23: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Lab. Components

Comfort Cap Impression Coping Analog Burn-out Cylinder

XSDAB 45 S CCC 45 CS CIC 45 L

CAN 45 SL CBC 45 SL CBC 45 BL

XSDAB 45 CCC 45 C CAN 45 LL

XSDAB 55 S CCC 55 CS CIC 55 L

CAN 55 SL CBC 55 SL CBC 55 BL

XSDAB 55 CCC 55 C CAN 55 LL

XSDAB 65 S CCC 65 CS CIC 65 L

CBC 65 SL CBC 65 SL CBC 65 BL

XSDAB 65 CCC 65 C CAN 65 LL

Combi & Dual Abutment

REF

Restorative Kit

SuperLine & Implantium Product Catalog 23

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 24

Page 24: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Impression Technique and Restoration Selection

Dual / Milling / Angled / Direct and Metal Casting / Temporary (Plastic & Ti) Abutment

Fixture Level Impression

Hex Non-hex

Impression Coping / Pick-upOpen Tray technique (Complicated case)

4.0 / 4.5 / 5.5 / 6.5Page 25

Impression Coping / TransferClosed Tray technique (Simple case)

4.0 / 4.5 / 5.5 / 6.5Page 26

Hex Non-hex

AnalogDAN 34 / DAN 38

Page 25,26

Cemented Restoration Screw-Retained Restoration

Modification Modification

DualAbutment

Hex / Non-hex4.5 / 5.5 / 6.5

Page 20, 21

Dual MillingAbutment

Hex / Non-hex4.0 / 4.5

5.5 / 6.5 / 7.5Page 27,28, 29,30

Direct-CastingAbutment

Hex / Non-hex4.5

Page 35

Metal-CastingAbutment

Hex / Non-hex4.5

Page 35

TemporaryAbutment

Hex / Non-hex4.5 / 5.5 / 6.5

Page 36

AngledAbutment

Hex / Non-hex15° / 25°4.5 / 5.5

Page 31, 32, 33, 34

Prosthetic Procedure 2

SuperLine & Implantium Product Catalog24

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 25

Page 25: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

12.0

4.0

12.0

4.5

Size REF

Short DPS 11

Long DPS 15

Impression Coping Pick-up Screw

Long

Short

Size Type REF

Short Hex DPU 40 11 HL

Short Non-hex DPU 40 11 NL

Long Hex DPU 40 15 HL

Long Non-hex DPU 40 15 NL

4.0 4.0 4.0 4.0

Impression Coping Pick-up 4.5

Size Type REF

Short Hex DPU 45 11 HL

Short Non-hex DPU 45 11 NL

Long Hex DPU 45 15 HL

Long Non-hex DPU 45 15 NL

Impression Coping Pick-up 5.5

Size Type REF

Short Hex DPU 55 11 HL

Short Non-hex DPU 55 11 NL

Long Hex DPU 55 15 HL

Long Non-hex DPU 55 15 NL

Impression Coping Pick-up 6.5

Size Type REF

Short Hex DPU 65 11 HL

Short Non-hex DPU 65 11 NL

Long Hex DPU 65 15 HL

Long Non-hex DPU 65 15 NL

Hex Non-hex

17.0 17.0

4.5 4.5

Hex Non-hex

17.0 17.0

5.5 5.5

Hex Non-hex

23.0

27.0

Fixture Platform Diameter REF 3.6 DAN 34

4.0, 4.5, 5.0, 6.0, 7.0 DAN 38

Analog

DAN 34 DAN 38

Fixture Level Impression Components

Note : 1)DAN34 should only be used with small diameter fixtures (Platform: 3.6mm/ Body: 3.4mm). 2)DAN38 should be used with all other fixture diameters.

Unit: mm

Scale 1 : 1.5 / mm

21.0 21.0 21.0 21.0

17.0 17.0 21.0 21.0

5.5 5.5

Hex Non-hex

Hex Non-hexHex Non-hex

6.5 6.5

Hex Non-hex

17.0 17.0

6.5

Hex

21.0

6.5

Non-hex

21.0

• Impression coping screw is included with impression coping.

4.5 4.5

Impression Coping Pick-up 4.0

SuperLine & Implantium Product Catalog 25

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 26

Page 26: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Fixture Level Impression Components

12.0

4.0

12.0

4.5

Size REF

Short DTS 11

Long DTS 15

Impression Coping Transfer Screw

Impression Coping Transfer 4.0

Size Type REF

Short Hex DTF 40 11 HL

Short Non-hex DTF 40 11 NL

Long Hex DTF 40 15 HL

Long Non-hex DTF 40 15 NL

Impression Coping Transfer 4.5

Size Type REF

Short Hex DTF 45 11 HL

Short Non-hex DTF 45 11 NL

Long Hex DTF 45 15 HL

Long Non-hex DTF 45 15 NL

Impression Coping Transfer 5.5

Size Type REF

Short Hex DTF 55 11 HL

Short Non-hex DTF 55 11 NL

Long Hex DTF 55 15 HL

Long Non-hex DTF 55 15 NL

Impression Coping Transfer 6.5

Size Type REF

Short Hex DTF 65 11 HL

Short Non-hex DTF 65 11 NL

Long Hex DTF 65 15 HL

Long Non-hex DTF 65 15 NL

4.0 4.0 4.0 4.0

Hex Non-hex Hex Non-hex

11.0 11.0

15.0 15.0

4.5 4.5 4.5 4.5

Hex Non-hex Hex Non-hex

11.0 11.0

15.0 15.0

5.5 5.5 5.5 5.5

Hex Non-hex Hex Non-hex

11.0 11.0

15.0 15.0

6.5 6.5 6.5 6.5

Hex Non-hex Hex Non-hex

11.0 11.0

15.0 15.0

Long

Short

14.0

18.0

Fixture Platform Diameter REF

3.6 DAN 34

4.0, 4.5, 5.0, 6.0, 7.0 DAN 38

Analog

DAN 34 DAN 38

Unit: mm

Scale 1 : 1.5 / mm• Impression coping screw is included with impression coping.

Note : 1)DAN34 should only be used with small diameter fixtures (Platform: 3.6mm/ Body: 3.4mm). 2)DAN38 should be used with all other fixture diameters.

SuperLine & Implantium Product Catalog26

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 27

Page 27: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

G/H 1.5

12

DAB55157H/NL and FX4510SW

Diameter 4.0

Diameter 4.5

Diameter 5.5

G/H Type REF

1.0 Hex DAB 40 105 HL

1.0 Non-hex DAB 40 105 NL

G/H Type REF

1.5 Hex DAB 45 156 HL

1.5 Non-hex DAB 45 156 NL

G/H Type REF

1.5 Hex DAB 55 157 HL

1.5 Non-hex DAB 55 157 NL

2.5 Hex DAB 55 257 HL

2.5 Non-hex DAB 55 257 NL

4.0

1.0 1.0

Hex

5.5

4.0

Non-hex

4.5

1.5

1.5 1.5 2.5 2.5

1.5

Hex

4.5

Non-hex

5.5

Hex

5.5

Non-hex

5.5

Hex

5.5

Non-hex

Dual Milling Abutment [ Ti-G4]Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters.2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog 27

2.3

2.0

2.3

2.0

2.3

2.0

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 28

Page 28: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Dual Milling Abutment [ Ti-G4]

Diameter 6.5 G/H Type REF

1.5 Hex DAB 65 158 HL

1.5 Non-hex DAB 65 158 NL

2.5 Hex DAB 65 258 HL

2.5 Non-hex DAB 65 258 NL

3.5 Hex DAB 65 358 HL

3.5 Non-hex DAB 65 358 NL

6.5

Hex

6.5

Non-hex

6.5

Hex

6.5

Non-hex

6.5

Hex

6.5

Non-hex

1.5 1.5 2.5 2.5

3.5 3.5

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog28

2.3

2.0

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 29

Page 29: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Dual Milling Abutment [ Ti-G2]

Diameter 4.0

Diameter 4.5

Diameter 5.5

G/H Type REF

1.0 Hex DAB 40 105 HG

1.0 Non-hex DAB 40 105 NG

G/H Type REF

1.5 Hex DAB 45 156 HG

1.5 Non-hex DAB 45 156 NG

G/H Type REF

1.5 Hex DAB 55 157 HG

1.5 Non-hex DAB 55 157 NG

2.5 Hex DAB 55 257 HG

2.5 Non-hex DAB 55 257 NG

4.0

1.0 1.0

Hex

4.0

Non-hex

4.5

1.5 1.5

Hex

4.5

Non-hex

1.5 1.5 2.5 2.5

5.5

Hex

5.5

Non-hex

5.5

Hex

5.5

Non-hex

G/H 1.5

12

DAB55157H/NG and FX4510SWC

5.5

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog 29

2.3

2.0

2.3

2.0

2.3

2.0

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 30

Page 30: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

2.3

2.0

Dual Milling Abutment [Ti-G2]

Diameter 6.5

G/H Type REF

1.5 Hex DAB 65 158 HG

1.5 Non-hex DAB 65 158 NG

2.5 Hex DAB 65 258 HG

2.5 Non-hex DAB 65 258 NG

3.5 Hex DAB 65 358 HG

3.5 Non-hex DAB 65 358 NG

Diameter 7.5

G/H Type REF

2.5 Hex DAB 75 259 HG

2.5 Non-hex DAB 75 259 NG

3.5 Hex DAB 75 359 HG

3.5 Non-hex DAB 75 359 NG

6.5

Hex

6.5

Non-hex

6.5

Hex

6.5

Non-hex

6.5

Hex

6.5

Non-hex

1.5 1.5 2.5 2.5

3.5 3.5

7.5

Hex

7.5

Non-hex

7.5

Hex

7.5

Non-hex

2.5 2.5 3.5 3.5

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than otherfixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog30

2.3

2.0

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 31

Page 31: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

2.3

2.0

2.3

2.0

Non-hex

2.5

5.5

4.5

Angled Abutment [Ti-G4 / 15°]

G/H 1.5

10.5

15°

Hex

Diameter 4.5 | Angled 15°

AAB154515H/NL and FX4510SWC

Diameter 5.5 | Angled 15°

1.5

4.5

Non-hex

1.5

4.5

Hex

2.5

4.5

Non-hex

2.5

4.5

Hex

3.5

4.5

Non-hex

3.5

4.5

Hex

1.5

5.5

Non-hex

1.5

5.5

Hex

2.5

5.5

Hex

3.5

5.5

Non-hex

3.5

5.5

G/H Type REF

1.5 Hex AAB 15 45 15 HL

1.5 Non-hex AAB 15 45 15 NL

2.5 Hex AAB 15 45 25 HL

2.5 Non-hex AAB 15 45 25 NL

3.5 Hex AAB 15 45 35 HL

3.5 Non-hex AAB 15 45 35 NL

G/H Type REF

1.5 Hex AAB 15 55 15 HL

1.5 Non-hex AAB 15 55 15 NL

2.5 Hex AAB 15 55 25 HL

2.5 Non-hex AAB 15 55 25 NL

3.5 Hex AAB 15 55 35 HL

3.5 Non-hex AAB 15 55 35 NL

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog 31

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 32

Page 32: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

2.3

2.0

2.3

2.0

Non-hex

2.5

5.5

4.5

Angled Abutment [Ti-G4 / 25°]

G/H 1.5

10.5

25°

Hex

Diameter 4.5 | Angled 25°

AAB254515H/NL and FX4510SWC

Diameter 5.5 | Angled 25°

1.5

4.5

Non-hex

1.5

4.5

Hex

2.5

4.5

Non-hex

2.5

4.5

Hex

3.5

4.5

Non-hex

3.5

4.5

Hex

1.5

5.5

Non-hex

1.5

5.5

Hex

2.5

5.5

Hex

3.5

5.5

Non-hex

3.5

5.5

G/H Type REF

1.5 Hex AAB 25 45 15 HL

1.5 Non-hex AAB 25 45 15 NL

2.5 Hex AAB 25 45 25 HL

2.5 Non-hex AAB 25 45 25 NL

3.5 Hex AAB 25 45 35 HL

3.5 Non-hex AAB 25 45 35 NL

G/H Type REF.

1.5 Hex AAB 25 55 15 HL

1.5 Non-hex AAB 25 55 15 NL

2.5 Hex AAB 25 55 25 HL

2.5 Non-hex AAB 25 55 25 NL

3.5 Hex AAB 25 55 35 HL

3.5 Non-hex AAB 25 55 35 NL

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog32

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 33

Page 33: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

2.3

2.0

2.3

2.0

Non-hex

2.5

5.5

4.5

Angled Abutment [Ti-G2 / 15°]

G/H 1.5

10.5

15°

Hex

Diameter 4.5 | Angled 15°

AAB154515H/NG and FX4510SWC

Diameter 5.5 | Angled 15°

1.5

4.5

Non-hex

1.5

4.5

Hex

2.5

4.5

Non-hex

2.5

4.5

Hex

3.5

4.5

Non-hex

3.5

4.5

Hex

1.5

5.5

Non-hex

1.5

5.5

Hex

2.5

5.5

Hex

3.5

5.5

Non-hex

3.5

5.5

G/H Type REF

1.5 Hex AAB 15 45 15 HG

1.5 Non-hex AAB 15 45 15 NG

2.5 Hex AAB 15 45 25 HG

2.5 Non-hex AAB 15 45 25 NG

3.5 Hex AAB 15 45 35 HG

3.5 Non-hex AAB 15 45 35 NG

G/H Type REF

1.5 Hex AAB 15 55 15 HG

1.5 Non-hex AAB 15 55 15 NG

2.5 Hex AAB 15 55 25 HG

2.5 Non-hex AAB 15 55 25 NG

3.5 Hex AAB 15 55 35 HG

3.5 Non-hex AAB 15 55 35 NG

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog 33

Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 34

Page 34: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

2.3

2.0

2.3

2.0Non-hex

3.5

4.5

Non-hex

2.5

5.5

4.5

Angled Abutment [Ti-G2 / 25°]

G/H 1.5

10.5

25°

Hex

Diameter 4.5 | Angled 25°

AAB254515H/NG and FX4510SWC

Diameter 5.5 | Angled 25°

1.5

4.5

Non-hex

1.5

4.5

Hex

2.5

4.5

Non-hex

2.5

4.5

Hex

3.5

4.5

Hex

1.5

5.5

Non-hex

1.5

5.5

Hex

2.5

5.5

Hex

3.5

5.5

Non-hex

3.5

5.5

G/H Type REF

1.5 Hex AAB 25 45 15 HG

1.5 Non-hex AAB 25 45 15 NG

2.5 Hex AAB 25 45 25 HG

2.5 Non-hex AAB 25 45 25 NG

3.5 Hex AAB 25 45 35 HG

3.5 Non-hex AAB 25 45 35 NG

G/H Type REF

1.5 Hex AAB 25 55 15 HG

1.5 Non-hex AAB 25 55 15 NG

2.5 Hex AAB 25 55 25 HG

2.5 Non-hex AAB 25 55 25 NG

3.5 Hex AAB 25 55 35 HG

3.5 Non-hex AAB 25 55 35 NG

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog34

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 35

Page 35: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

2.3

2.0

2.3

2.0

4.5

Direct-Casting Abutment / Metal-Casting Abutment

G/H 1.0

12

4.5

Direct-Casting Abutment I Gold

RAB45GH/N and FX4510SWC

Hex

G/H Type REF

1.0 Hex RAB 45 GH

1.0 Non-hex RAB 45 GN

4.5

4.5

12

1.0

Metal-Casting Abutment I Co-Cr

G/H Type REF

1.0 Hex RAB 45 CH

1.0 Non-hex RAB 45 CN

4.5G/H 1.0

12

4.5

RAB45CH/N and FX4510SWC

Non-hex

4.5

4.5

12

1.0

Hex

4.5

4.5

12

1.0

Non-hex

4.5

4.5

12

1.0

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog 35

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 36

Page 36: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

2.3

2.0

2.3

2.0

Temporary Abutment

Plastic Temporary Abutment

Diameter G/H Type REF

4.5 1.0 Hex RAB 45 THG

4.5 1.0 Non-hex RAB 45 TNG

Ti-Temporary Abutment

Diameter G/H Type REF

4.5 2.0 hex RAB 45 20 PHL

4.5 2.0 Non-hex RAB 45 20 PNL

5.5 2.0 hex RAB 55 20 PHL

5.5 2.0 Non-hex RAB 55 20 PNL

6.5 2.0 hex RAB 65 20 PHL

6.5 2.0 Non-hex RAB 65 20 PNL

Hex

4.5

10

1.0

4.54.5

8.0

2.0

Non-hexhex

G/H 1.0

10

4.5

RAB45TH/NG and FX4510SWC

G/H 2.0

8.0

4.5

RAB4520PH/NL and FX4510SWC

Non-hex

4.5

10

1.0

5.55.5

8.0

2.0

Non-hexhex

6.56.5

8.0

2.0

Non-hexhex

Unit: mm

Scale 1 : 1.5 / mm• Abutment screw is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog36

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 37

Page 37: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Prosthetic Procedure 3

Screw Abutment

Open Tray Technique Closed Tray Technique

Screw-Retained Restoration

Abutment Level Impression

Screw Abutment4.5 / 5.5Page 38

Analog4.5 / 5.5

Page 40

Impression Coping TransferBridge / Single 4.5 / 5.5

Page 39

Polishing Protector4.5 / 5.5

Page 40

Ti-Retaining ScrewPage 40

Impression Technique and Restoration Selection

Impression Coping Pick-upBridge / Single 4.5 / 5.5

Page 39

Metal Cylinder4.5 / 5.5

Page 41

Gold Cylinder4.5 / 5.5

Page 41

Burn-out Cylinder4.5 / 5.5

Page 41

Bridge(Non-hex)

Single(Hex)

Temporary Restoration

Titanium Cylinder4.5 / 5.5

Page 41

Single(Hex)

Bridge(Non-hex)

Bridge(Non-hex)

Single(Hex)

Bridge(Non-hex)

Single(Hex)

SuperLine & Implantium Product Catalog 37

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 38

Page 38: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Screw Abutment

Diameter 4.5

G/H 3.5

5.5

SAB5535L and FX4510SWC

G/H REF

1.0 SAB45 10 L

1.5 SAB45 15 L

2.5 SAB45 25 L

3.5 SAB45 35 L

4.5 SAB45 45 L

5.5 SAB45 55 L

1.0 1.5 2.5 3.5 4.5 5.5

1.5 2.5 3.5 4.5 5.5

Diameter 5.5 G/H REF

1.5 SAB55 15 L

2.5 SAB55 25 L

3.5 SAB55 35 L

4.5 SAB55 45 L

5.5 SAB55 55 L

G/H

G/H

G/H

G/H

Unit: mm

Scale 1 : 1.5 / mm• Delivery Holder is included.

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

Delivery Holder

SuperLine & Implantium Product Catalog38

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 39

Page 39: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Impression Coping Pick-up Diameter Type REF

4.5 Single Hex SPU 45 SL

4.5 Bridge Non-hex SPU 45 BL

5.5 Single Hex SPU 55 SL

5.5 Bridge Non-hex SPU 55 BL

Diameter Type REF

4.5 Single Hex STF 45 SL

4.5 Bridge Non-hex STF 45 BL

5.5 Single Hex STF 55 SL

5.5 Bridge Non-hex STF 55 BL

Type REF

Pick-up SPS 15

Transfer STS 09

Impression Coping Screw

Screw Abutment Impression ComponentsUnit: mm

Scale 1 : 1.5 / mm

4.54.5

5.55.5

Bridge (Non-hex)Single (Hex)

Bridge (Non-hex)Single (Hex)

4.54.5

5.55.5

Bridge (Non-hex)Single (Hex)

Bridge (Non-hex)Single (Hex)

15.0

9.0

• Impression Coping Screw is included with impression coping.

Impression Coping Transfer

SuperLine & Implantium Product Catalog 39

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 40

Page 40: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Screw Abutment Impression Components

Diameter REF

4.5 SAN 45 L

5.5 SAN 55 L

5.5Analog 4.5

5.5

Polishing Protector4.5

SRS 18 T

Ti-Retaining Screw

Diameter REF

4.5 SPP 45 L

5.5 SPP 55 L

5.5

Comfort Cap4.5 Diameter REF

4.5 SCC 45 L

5.5 SCC 55 L5.0 5.0

12.0 12.0

1.8

2.3

Unit: mm

Scale 1 : 1.5 / mm

• Ti-Retaining screw is included.1.8

2.3

SuperLine & Implantium Product Catalog40

REF

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 41

Page 41: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Burn-out Cylinder Diameter Type REF

4.5 Single Hex

4.5 Bridge Non-hex

5.5 Single Hex

5.5 Bridge Non-hex

Screw Abutment Components

Gold Cylinder

4.54.5

5.55.5

5.55.5

4.54.5

Diameter Type REF

4.5 Single Hex

4.5 Bridge Non-hex

5.5 Single Hex

5.5 Bridge Non-hex

Bridge (Non-hex)Single (Hex)

Bridge (Non-hex)Single (Hex)

Bridge (Non-hex)Single (Hex)

Bridge (Non-hex)Single (Hex)

12.0 12.0

12.0 12.0

12.0 12.0

12.0 12.0

1.8

1.8

1.8

1.8

2.3

2.3

Metal Cylinder I Co-Cr

4.54.5

5.55.5

Diameter Type REF

4.5 Single Hex

4.5 Bridge Non-hex

5.5 Single Hex

5.5 Bridge Non-hex

Bridge (Non-hex)Single (Hex)

Bridge (Non-hex)Single (Hex)

12.0 12.0

12.0 12.0

1.8

1.8

2.3

2.3

2.3

2.3

5.55.5

Ti-Cylinder

4.54.5

Diameter Type REF

4.5 Single Hex

4.5 Bridge Non-hex

5.5 Single Hex

5.5 Bridge Non-hex

Bridge (Non-hex)Single (Hex)

Bridge (Non-hex)Single (Hex)

8.7

3.3

8.7

3.3

8.7

3.3

8.7

3.3

1.8

1.8

2.3

2.3

Unit: mm

Scale 1 : 1.5 / mm• Ti-Retaining screw is included with cylinders.

Note : 10N cm of torque is recommended for cylinders.

STC 45 SG

STC 45 BG

STC 55 SG

STC 55 BG

SBC 45 SL

SBC 45 BL

SBC 55 SL

SBC 55 BL

SGC 45 SL

SGC 45 BL

SGC 55 SL

SGC 55 BL

SGC 45 CSL

SGC 45 CBL

SGC 55 CSL

SGC 55 CBL

SuperLine & Implantium Product Catalog 41

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 42

Page 42: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Prosthetic Procedure 4Impression Technique and Restoration Type

Overdenture Procedure

Ball Attachment

Ball Abutment3.5

Page 43

Abutment Level Impression

Ball Impression CopingPage 43

Ball AnalogPage 43

Socket SpacerPage 43

Female Socket and O-ringPage 43

SuperLine & Implantium Product Catalog42

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 43

Page 43: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Ball Attachment

Ball Impression Coping

Ball Analog

BAB352018 and FX4510SWC

Female Socket

G/H 2.0

2.9

4.05

Ball Abutment G/H REF

0 BAB 35 0018

1.0 BAB 35 1018

2.0 BAB 35 2018

3.0 BAB 35 3018

4.0 BAB 35 4018

5.0 BAB 35 5018

4.0

1.8

3.5

3.0

1.8

3.5

2.0

1.8

3.5

1.0

1.8

3.5

1.8

3.3

5.0

1.8

3.5

Socket Spacer

REF BIC3L

7.5

3.8

(300~500gf) (500~700gf)

(BFS3) (BNO1) (BFS2) (BNO2)

4.05 4.85

2.9 3.3 REF

BPF3 (300~500gf)

BPF2 (500~700gf)

REF BANL

REF ICA

Unit: mm

Scale 1 : 1.5 / mm

Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.

SuperLine & Implantium Product Catalog 43

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 44

Page 44: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Surgical Kit [Full]

Kit Contents

Countersink XCS 36 29 SW

XCS 40 29 SW

XCS 45 29 SW

XCS 50 29 SW

XCS 60 29 SW

XCS 70 29 SW

Hand-piece adapter

Ratchet adapter

Parallel pin x4

Path pin x2

Depth gauge

Hex driver

Ratchet

Drill extension

XPP 162220 T

XID 27 H

XID 32 H

XID 26 W

XID 32 W

XMFPA2

XHD 26 T

XDE

XDGL

XRCA1

Final drill (Stopper) XFD 34 35

XFD 38 35

Final drill XFD 34 29

XFD 38 29

XFD 43 29

XFD 48 29

XFD 58 31

Lindemann guide drill XLD 22 29

XLD 26 29Lindemann first drill

XLD 22 35

XLD 26 35

(Stopper)

(Stopper)

XFD 43 35

XFD 48 35

REF UXIF

SuperLine & Implantium Product Catalog44

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 45

Page 45: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Drill Stopper Kit

Kit Contents

Lindemann drill stopper

XLD 22 35

XLD 26 35

Final drill stopper / 34, 38

XFD 34 35

XFD 38 35

Stopper-lindemann drill

Stopper-final drill / 34, 38

XLDST 14 XLDST 12 XLDST 10 XLDST 08 XLDST 06

XFDST 14 XFDST 12 XFDST 10 XFDST 08 XFDST 06

Final drill stopper / 43, 48

XFD 43 35

XFD 48 35

Stopper-final drill / 43, 48

XFDST 14L XFDST 12L XFDST 10L XFDST 08L XFDST 06L

REF XDS

SuperLine & Implantium Product Catalog 45

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 46

Page 46: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Drill

Guide Drill

Pilot Drill1.93.0

30

1.528

Diameter L REF

1.5 20 XGD 15 20

1.5 28 XGD 15 28

1.520

Diameter L REF

3.0 30 XPD 20 30

First Drill2.0

33 Diameter L REF

2.0 33 XFD 20 33

33

33

Lindemann Guide Drill

Diameter L REF

2.2 29 XLD 22 29

2.2 31 XLD 22 31

2.2 33 XLD 22 33

2.2 35 XLD 22 35

2.2 41 XLD 22 41

Lindemann First Drill

Diameter L REF

2.6 29 XLD 26 29

2.6 31 XLD 26 31

2.6 33 XLD 26 33

2.6 35 XLD 26 35

2.6 41 XLD 26 41

2.352.6

1.72.2

1.72.2

35

2.352.6

29

1.72.2

29

2.352.6

31

1.72.2

31

2.352.6

41

1.72.2

41

2.352.6

35

Unit: mm

Scale 1 : 1.5 / mm

8 10 12 14 16

SuperLine & Implantium Product Catalog46

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 47

Page 47: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Diameter L REF

2.85 29 XFD 34 29

3.3 29 XFD 38 29

3.85 29 XFD 43 29

4.4 29 XFD 48 29

5.4 29 XFD 58 29SW

Final Drill | Length-29mm

Diameter L REF

2.85 33 XFD 34 33

3.3 33 XFD 38 33

3.85 33 XFD 43 33

4.4 33 XFD 48 33

Final Drill | Length-33mm

12

29

16

33

Diameter L REF

2.85 31 XFD 34 31

3.3 31 XFD 38 31

3.85 31 XFD 43 31

4.4 31 XFD 48 31

5.4 31 XFD 58 31

Final Drill | Length-31mm2.85

3.3

3.85

14

4.4

2.85

3.3

3.85

4.4

5.4

31

2.85

3.3

3.85

4.4

5.4

Unit: mm

Scale 1 : 1.5 / mm

Drill SuperLine & Implantium Product Catalog 47

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 48

Page 48: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Drill

Diameter L REF

2.85 35 XFD 34 35

3.3 35 XFD 38 35

3.85 35 XFD 43 35

4.4 35 XFD 48 35

Final Drill Length-35mm | Stopper

2.0

3.0

35

3.6

4.0

4.5

5.0

29

Countersink6.0

7.0

Diameter REF

3.6 XCS 36 29 SW

4.0 XCS 40 29 SW

4.5 XCS 45 29 SW

5.0 XCS 50 29 SW

6.0 XCS 60 29 SW

7.0 XCS 70 29 SW

Round Bur

27

Diameter L REF

2.85 41 XFD 34 41

3.3 41 XFD 38 41

3.85 41 XFD 43 41

4.4 41 XFD 48 41

Diameter L REF

2.0 33 XRB 20 33

3.0 33 XRB 30 33

Final Drill Length-41mm2.85

3.3

3.85

4.4

16

41

2.85

3.3

3.85

4.4

Unit: mm

Scale 1 : 1.5 / mm

SuperLine & Implantium Product Catalog48

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 49

Page 49: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Stopper

Drilling Depth L REF

14 4.6 XLDST 14

12 6.6 XLDST 12

10 8.6 XLDST 10

08 10.6 XLDST 08

06 12.6 XLDST 06

04 14.6 XLDST 04

02 16.6 XLDST 02

XLDST14

Stopper | For Lindemann Guide, First Drill

XLDST12XLDST10

XLDST08XLDST06

4.45 4.45 4.45 4.45 4.45

12.610.68.66.6

4.6

Drilling Depth L REF

14 4.6 XFDST 14

12 6.6 XFDST 12

10 8.6 XFDST 10

08 10.6 XFDST 08

06 12.6 XFDST 06

04 14.6 XFDST 04

02 16.6 XFDST 02

Stopper | For Final Drill 3435, 3835

14.6 16.6

4.45 4.45

XFDST14XFDST12

XFDST10XFDST08

XFDST06

5.14 5.14 5.14 5.14 5.14

12.610.68.66.6

4.6

14.6 16.6

5.14 5.14

XLDST04 XLDST02

XFDST04 XFDST02

Drilling Depth L REF

14 4.6 XFDST 14L

12 6.6 XFDST 12L

10 8.6 XFDST 10L

08 10.6 XFDST 08L

06 12.6 XFDST 06L

04 14.6 XFDST 04L

02 16.6 XFDST 02L

Stopper | For Final Drill 4335, 4835

XFDST14LXFDST12L

XFDST10LXFDST08L

XFDST06L

6.14 6.14 6.14 6.14 6.14

12.610.68.66.6

4.6

14.6 16.6

6.14 6.14

XFDST04L XFDST02L

Unit: mm

Scale 1 : 1.5 / mm

SuperLine & Implantium Product Catalog 49

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 50

Page 50: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Instrument

Parallel Pin | For Lindemann Drill

Diameter REF

1.6 XPP 162220T

1.6 XPP 162226T

Path Pin

20

26

1.6

1.6

L REF

18.6 XMFPA2 18.6

Adapter | Hex 1.28mm

Type L REF

27 XID 27 H

Hand-piece 30 XID 30 H

32 XID 32 H

24 XID 24 W

26 XID 26 W

29 XID 29 W

32 XID 32 W

32

32

29

26

24

27

30

Ratchet

Unit: mm

Scale 1 : 1.5 / mm

SuperLine & Implantium Product Catalog50

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 51

Page 51: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Instrument

Hex Driver | Hex 1.28mm

Slot Driver

Type L REF

Hand-piece 25 XHD 25 H

21 XHD 21 W

25 XHD 25 W

27 XHD 27 W

26 XHD 26 T 30 XHD 30 T

Type REF

SDA 17 R

SDA 25 R

25

30

26

25

17

Driver | Manual

Type REF

Manual XHDHT

21

12

Drill Extension

REF26

Ratchet

27

25

Ratchet

XDE

Unit: mm

Scale 1 : 1.5 / mm

Manual [w/ wheel ]

SuperLine & Implantium Product Catalog 51

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 52

Page 52: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Instrument

Adapter | For screw Abutment Scale 1 : 1 / mm

Ratchet

Torque Wrench | Scale 1 : 0.7 / mm

Depth Gauge

Note : One side of Depth Gauge measures the osteotomy

depth and the other side measures the gingival

height from the top of the implant.

Type REF

Hand-piece XMAA1

Ratchet XMA 21W

20

21

Tissue Punch | Scale 1 : 1 / mm

Punching size : 4.0

Adapter | For ball abutment | Scale 1 : 1 / mm

21 REF IPST21W

REF XRCA1

REF XNTW

REF XDGL

REF XTS40

Unit: mm

SuperLine & Implantium Product Catalog52

4.0

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 53

Page 53: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

DASK [Dentium Advanced Sinus Kit]

XFDST08

Kit Contents

DASK drill XRT332035

XED331035D

XRT372035

XRT064025

XRT084025

XST083025

Stopper

XFDST 08 XFDST 06 XFDST 04 XFDST 02

Sinus elevation instrumentXSE1L

XSE2L

XSE3L

XSE4L

REF DASK

SuperLine & Implantium Product Catalog 53

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 54

Page 54: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Sinus Bur Kit / Sinus Kit

XRT083025

Kit Contents

DASK Drill XRT332035

XED331035D

XRT372035

XRT064025

XRT084025

XST083025

Stopper XFDST 08 XFDST 06 XFDST 04 XFDST 02

(XSE1L)

(XSE2L)

(XSE3L)

(XSE4L)

REF SDK

REF XSKL

SuperLine & Implantium Product Catalog54

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 55

Page 55: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

DASK / Sinus Bur Kit / Sinus Kit

XRT332035

XED331035D

3.3

24681012

3.3

0

24681012 1 0

XRT372035 3.7

24681012 0

XRT064025

DASK Drill | Scale 1 : 1.2 / mm

XRT084025

XST083025

6.0

4.0

8.0

8.0

1.5 1.5

XFDST08XFDST06

XFDST04

5.145.14 5.14 5.14

14.612.610.6

16.6

XFDST02

Drilling Depth L REF

08 10.6 XFDST 08

06 12.6 XFDST 06

04 14.6 XFDST 04

02 16.6 XFDST 02

Stopper | For XRT332035, XRT372035, XED331035D | Scale 1 : 1 / mm

6.6

Sinus Elevation Instrument | Scale 1 : 0.45 / mm

XSE1L

XSE2L

XSE3L

XSE4L

Note : Drill speed 800 to 1,200rpm, 30~45N.cm with irrigation.

Crestal Approach

Type DASK Drill # REF

DASK Drill #1 XRT 332035

DASK Drill #2 XRT 372035

DASK Drill #3 XED 331035D

DASK Drill #4 XRT 064025

DASK Drill #5 XRT 084025

DASK Drill #6 XST 083025

Lateral Approach

4.0

SuperLine & Implantium Product Catalog 55

Unit: mm

Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 56

Page 56: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Osteotome Kit

A B

Osteotome Kit

Osteotome compresses the bone laterally, providing a denser bony interfacerather than removing valuable bone from the surgical site.

Osteotome Kit

XOF 20 A1

XOF 34 A1

XOF 38 A1

XOF 43 A1

XOF 48 A1

XOF 20 B1

XOF 34 B1

XOF 38 B1

XOF 43 B1

XOF 48 B1

Osteotome | Final drill type | Scale 1 : 0.4 / mm

Type REF A B

XOF 20 A1 1.7 2.8

XOF 34 A1 2.3 2.8

XOF 38 A1 2.7 3.2

XOF 43 A1 2.8 3.8

XOF 48 A1 3.0 4.3

XOF 20 B1 1.7 2.8

XOF 34 B1 2.3 2.8

XOF 38 B1 2.7 3.2

XOF 43 B1 2.8 3.8

XOF 48 B1 3.0 4.3

Type B

Type A

A B

XOFBK

Type A(Convex)

Type B(Concave)

(Convex)

(Concave)

XOFK

XOFK (Type A)

XOFBK (Type B)

Unit: mm

SuperLine & Implantium Product Catalog56

REF

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 57

Page 57: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Trephine Kit

Trephine Bur

• Excellent fine cutting• Strong engagement of the trephine to cortical bone• Cut-outs facilitate ease of harvest retrieval.• 5 depth marks on the trephine drill from 2mm to 10mm• Easy harvesting

3723

14 108642

Outer Inner Diameter Diameter

3.0 2.3 XTP 24 03

4.0 3.3 XTP 34 04

5.0 4.2 XTP 44 05

6.0 5.2 XTP 54 06

7.0 6.1 XTP 64 07

8.0 7.1 XTP 74 08

9.0 8.0 XTP 84 09

10.0 9.0 XTP 94 10

REF

Trephine Bur | Scale 1 : 0.5 / mm 3.0

2.3

5.0

4.2

7.0

6.1

9.0

8.0

4.0

3.3

6.0

5.2

8.0

7.1

10.0

9.0

Trephine Kit | Complete

Front View

Side View

Front View

Side View

Front View

Side View

Front View

Side View

Front View

Side View

Front View

Side View

Front View

Side View

Front View

Side View

REF XIT

Outer

Inner

Outer

Inner

Outer

Inner

Outer

Inner

Outer

Inner

Outer

Inner

Outer

Inner

Outer

Inner

Unit: mm

SuperLine & Implantium Product Catalog 57

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 58

Page 58: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Prosthetic Kit

Hex Driver S/T Scale 1 : 1 / mm

B.WRENCHADAPTER

Slot Driver Scale 1 : 1 / mm

Hex Driver T/W Scale 1 : 1 / mm

Hex Driver L/T Scale 1 : 1 / mm

Mount Adapter Scale 1 : 1 / mmFor Screw Abutment with Hand-Piece

T/W Adapter Scale 1 : 1 / mmFor Screw Abutment with Torque Wrench

Ball Adapter Scale 1 : 1 / mmFor Ball Abutment with Torque Wrench

REF XHD 15

REF IPST 21 W

REF XHD 25 W REF XMAA1

REF XMA 21 W

REF XNTW

Torque Wrench Scale 1 : 0.5 / mm

REF XIP

SuperLine & Implantium Product Catalog58

Unit: mm

REF SDA 25 R REF XHD 30 T

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 59

Page 59: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Planning Kit

Diameter 4.5 | Combi & Dual Abutment

G/H REF

1.5 PDAB 45 15

2.5 PDAB 45 25

3.5 PDAB 45 35

4.5 PDAB 45 45

5.5 PDAB 45 55

Diameter 5.5 | Combi & Dual Abutment

G/H REF

1.5 PDAB 55 15

2.5 PDAB 55 25

3.5 PDAB 55 35

4.5 PDAB 55 45

5.5 PDAB 55 55

Angled 15° | Angled Abutment

Diameter G/H REF

4.5 2.0 PAAB 15 45 20

4.5 4.0 PAAB 15 45 40

5.5 2.0 PAAB 15 55 20

5.5 4.0 PAAB 15 55 40

Angled 25° | Angled Abutment

Diameter G/H REF

4.5 2.0 PAAB 25 45 20

4.5 4.0 PAAB 25 45 40

5.5 2.0 PAAB 25 55 20

5.5 4.0 PAAB 25 55 40

Diameter 6.5 | Combi & Dual Abutment

G/H REF

1.5 PDAB 65 15

2.5 PDAB 65 25

3.5 PDAB 65 35

4.5 PDAB 65 45

5.5 PDAB 65 55

1.5

G/H2.5 3.5 4.5 5.5

5.5

1.5 2.5 3.5 4.5 5.5

152.0

G/H

152.0

154.0

154.0 2.0

252.0

252.0

254.0

254.0

G/H G/H

1.5 2.5 3.5 4.5

G/H

Unit: mm

Scale 1 : 1 / mm

REF XPK

SuperLine & Implantium Product Catalog 59

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 60

Page 60: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Prosthetic and Laboratory Instrument

Reamer Guide | For Screw Abutment

Diameter REF

4.5 CRG 45 L

5.5 CRG 55 L

6.5 CRG 65 L

Reamer Guide | For Combi / Dual Abutment

4.5

5.5

6.5

Bridge

Single

Type REF

Bridge SRG BL

Single SRG SL

Hex driver | Hex 1.28mm

Type L REF

21 XHD 21 T

28 XHD 28 T

13 XHD 13

15 XHD 15

21 XHD 21

28 XHD 28

Manual[w/ wheel]

Manual[w/o wheel]

15 21 2813

21 28

Unit: mm

Scale 1 : 1 / mm

SuperLine & Implantium Product Catalog60

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 61

Page 61: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Prosthetic and Laboratory Instrument

Reamer Handle | Scale 1 : 0.5 / mm

Hand Wrench | Scale 1 : 1 / mm

Reamer (For Combi / Dual Abutment) | Scale 1 : 1 / mm

Reamer (For Screw Abutment) | Scale 1 : 1 / mm

REF CRH

REF XHW

REF CRM

REF SRM

Unit: mm

SuperLine & Implantium Product Catalog 61

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 62

Page 62: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Help Kit

Screw Remover

L REF

25 XRFS2S

33 XRFS2

25

33

Abutment Hex Remover

L REF

20 XRHR20

25 XRHR25

2025

Screw Tap Repair

Type REF

Tap XRSTR

11° Guide XRSG11

8 ° Guide XRSG8

25 11°

25

Cover & Abutment Screw Remover L REF

25 XRRHD

Fixture Remover

Type REF

XRFRT

Remover XRFRTF

XRFRTO

Wrench XRFRW

25

Wrench

25 25

REF XIH

SuperLine & Implantium Product Catalog62

Unit: mm

Scale 1 : 1 / mm

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 63

Page 63: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Surgical Kit Maintenance

Sterilization and Instrument Care Procedures

• Please follow legal regulations, as well as hygienic guidelines to prevent contamination andinfection through prevention.

• Please remember that you are responsible for the maintenance and sterility of your medical/dental products/device. It is important to use and follow proper cleaning, disinfection andsterilization procedures.

• It is also important to follow the manufacture!s recommendation on the usage of drills. Pleasekeep a log as to how many times the drills are used.

• Drills are used per implant placed not per patient. Bone density determines the life of the drills.• Replace white and red o-rings on adapters and hex drivers, if worn and dried out.• Drills should be considered for replacement around 40 uses based on bone density.

01 All instruments immediately after use must be pre-soaked for a few minutes in a germicidal bath to loosen and prevent debris from attaching to instruments. Do not soak over-night.

02 Scrub with a soft brush to remove any debris.03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.04 If using an ultrasonic cleaner, wrap drills in a 2 x 2 to prevent rubbing against each other.05 Rinse thoroughly under warm water.06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.07 Dry completely and place back into kit.08 Always check for damage or corrosion after rinsing and drying.09 Seal the tray in a sterilization pouch.10 Sterilize using a steam autoclave in 121°C/250F for 30 minutes or refer to manufactures

recommendtions.11 Store in a dry area at room temperature.

Maintenance Period for Surgical Drills

(1000rpm, 30~45N·cm with Irrigation)

All surgical drills shall be replaced after approximately 40 uses based on bone density.

(1000rpm, 30~45N·cm with Irrigation)

Depending on bone density, the rpmcould be abjusted

(1000rpm, 30~45N·cm with Irrigation)

Cover & Abutment Screw Remover

Lindermann Guide Drill

Lindermann First Drill

Final Drill

Countersink Drill

SuperLine & Implantium Product Catalog 63

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 64

Page 64: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

DASK Maintenance

Sterilization and Instrument Care

Maintenance Period for DASK Drills

(800 ~1,200rpm, 30~45N.cm with internal irrigation)

All surgical drills shall be replaced with new one after approximately 20 uses based on bone density.

(800 ~1,200rpm, 30~45N.cm with internal irrigation)

(800 ~1,200rpm, 30~45N.cm with internal irrigation)

(800 ~1,200rpm, 30~45N.cm with internal irrigation)

(800 ~1,200rpm, 30~45N.cm with internal irrigation)

(800 ~1,200rpm, 30~45N.cm with external irrigation)

• Please follow legal regulations, as well as hygienic guidelines to prevent contamination andinfection through prevention.

• Please remember that you are responsible for the maintenance and sterility of your medical/dental products/device. It is important to use and follow proper cleaning, disinfection andsterilization procedures.

• It is also important to follow the manufacture!s recommendation on the usage of drills. Pleasekeep a log as to how many times the drills are used.

• Drills are used per implant placed not per patient. Bone density determines the life of the drills.• Replace white and red o-rings on adaptes and hex drivers, if worn and dried out.• Drills should be considered for replacement around 20 uses based on bone density.

01 All instruments immediately after use must be pre-soaked for a few minutes in a germicidal bath to loosen and prevent debris from attaching to instruments. Do not soak over-night.

02 Scrub with a soft brush to remove any debris.03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.04 If using an ultrasonic cleaner, wrap drills in a 2 x 2 to prevent rubbing against each other.05 Rinse thoroughly under warm water.06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.07 Dry completely and place back into kit.08 Always check for damage or corrosion after rinsing and drying.09 Seal the tray in a sterilization pouch.10 Sterilize using a steam autoclave in 121°C/250F for 30 minutes or refer to manufactures

recommendations.11 Store in a dry area at room temperature.

SuperLine & Implantium Product Catalog64

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 65

Page 65: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

The followings are the terms and conditions under which Dentium USA sells its products.

Governing Terms :Any shipment of product shall be deemed to be according to the terms and conditions stated herein. Anyand all terms and conditions submitted by Purchaser are hereby rejected. Taxes : The prices set forth herein do not include any sale, use, excise, ad valorem, property or other taxesapplicable to the sale, use or delivery of the products, all of which shall be paid by Purchaser separatelyor added to the contract price and paid by Purchaser to Dentium USA. Pricing : The prices set forth for the products are in United States Dollars. Prices are subject to change without notice. Payment : Payment terms shall be as set forth under the “Terms” section on the front of the invoice. Delivery : Products sold hereunder shall be delivered F.O.B. manufacturer!s plant or distributor!s plant, as applicable.Purchaser shall assume reponsibility for all subsequent delivery or shipping charges.

Warranty : Dentium USA or any of its affiliates makes no warranty, express or implied, except that its products shall befree from defects in material and workmanship. This warranty applies only to the original Purchaser and isnon-transferable. In the event of a product defect, please immediately notify Dentium USA of the defectprior to returning the product. Devices shall be sterilized prior to return. As its sole obligation and asPurchaser!s sole remedy under this warranty, Dentium USA"will at its option, either repair, replace or issuecredit for such product. Purchaser assumes all risks and liability resulting from the use of these products,whether used separately or in combination with other products.

Education; Modification of Products : Dentium USA"strongly recommends completion of formal post graduate implant education and strictadherence to the procedures described in Dentium USA!s implant instruction manuals. Dentium USAcontinuosly strives to improve its products and therefore reserves the right to improve, modify or discontinueproducts at any time, or to change specifications of the products without notice and without incurring any obligation.

Return Policy : A Purchaser may return any unopened Dentium USA product that is in its original packaging within90 days of the invoice date. Dentium USA products returned within 30 days of the invoice date willbe accepted without any restocking fee to the purchaser. Dentium USA products returned between31 and 90 days of invoice date will be subjected to 15% re-stocking fee.

No returns will be permitted over 90 days from invoice date. To return an item, contact your local salesrepresentative or call Dentium USA Customer Service Department for a Return Material Authorization(RMA) number. Issuance of a RMA number does not guarantee that the product will be accepted forreturn. No product returns will be accepted without a RMA number. Dentium USA product will beaccepted for return only if the Dentium USA product is (1) returned in its original, unopened package(including autoclavable products); (2) received by Dentium USA within 90 days after the invoice datefor that product; and (3) returned freight prepaid and accompanied by the Dentium USA RMAnumber. (4) implants and prosthetic parts being returned for credit or exchange must have at leasta 6 month shelf life remaining. Individual items from a kit cannot be returned for credit.

Previously exchanged items cannot be returned for credit. Please do not give any item(s) to bereturned to your local Sale Representative. All products must be sent directly to the ReturnsDepartment of Dentium USA. Procedures and policies as stated are subject to change without priornotice.

Terms and Conditions of sale

SuperLine & Implantium Product Catalog 65

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 66

Page 66: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Terms and Conditions of sale

Dentium USA Customer ServiceMonday - Friday 8:30 am –5:30 pm (PST)

Phone : 1-877-304-6752Fax: 1-714-226-0019

Ema i l :[email protected]

Exchange Policy :Dentium USA products may be exchanged within 180 days of the invoice date, without a re-stockingfee, for other Dentium USA products of equal or lesser value within the same product family asdetermined by Dentium USA (ex. implant for implant, abutment for abutment, bone graft materialfor bone graft material). Dentium USA products may be exchanged within 180 days of the invoicedate for other Dentium USA!products of greater value within the same product family as determinedby Dentium USA (ex. implant for implant, abutment for abutment, bone graft material for bone graftmaterial) with the price differential paid by the Purchaser. In both cases, the exchanged DentiumUSA product must be (1) returned in its original, unopened package (including autoclavable products);(2) a currently offered Dentium USA!product ( discontinued product not included); (3) returnedfreight prepaid and accompanied by the Dentium Return Material Authorization number providedby Dentium USA"s Customer Service Department. Licenses, permits and export control :The timely securing of permits, licenses or other local, state or federal governmental approvals required inconnection with Purchaser!s use of any product hereunder shall be the sole responsibility of Purchaser andPurchaser shall bear the cost thereof. Unless otherwise agreed between Dentium USA and Purchaser,products sold hereunder are only for use in the United States. Purchaser agrees that Purchaser will complyfully with all applicable state and federal laws and regulation and Purchaser shall indemnify Dentium USAfor all losses, damages and penalties incurred as a result of any violation of applicable state or federal lawor regulations. Force Majeure :Dentium USA shall not be liable for any loss or damage due to failure or delay arising out of any causebeyond the reasonable control of Dentium USA. In the event of any failure or delay resulting from suchcauses, an equitable adjustment of delivery and any other appropriate terms and conditions shall be made.No such failure or delay shall be the basis for an increase in neither Dentium USA!s obligations nor anytermination by Purchaser. Limitation of Liability :Except for the warranty expressly described in the “Warranty” paragraph above, neither Dentium USA norany of its affiliates makes any other warranty with respect to the Dentium USA products, express or implied,written or oral including, without limitation, any implied warranty of merchantability, or a warranty of fitnessfor a particular purpose. Neither Dentium USA nor any of its affiliates shall be liable for business interruption,loss of profits, special, indirect, incidental or consequential damages of any nature and from any causewhether based in contract, tort ( including negligence) or other legal theory, even if Dentium USA or any ofits affiliates has been advised of the possibility of such damages. Validity :If any provision of these Terms and conditions is found to be illegal or unenforceable in any respect, suchillegality or unenforceability shall not affect any other provision of these Terms and Conditions, all of whichshall remain enforceable in accordance with their terms. General Provisions :The Purchase of the products and these Terms and Conditions are governed by the laws of California,without regard to conflicts of law principles. This document incorporates all oral and written representationsbetween the parties and constitutes the entire agreement and understanding of the parties with respect tothe subject matter hereof and supersedes any and all other agreements either oral or written between theparties with respect to such subject matter. No amendment or modification may be made to this documentunless in writing and duly executed by an authorized representative of Dentium USA. Caution :Federal ( U.S ) Law restricts these devices to sale by or on the order of a licensed healthcare practitioner.Devices labeled “Sterile” are certified to be sterile unless package is opened or damaged. Patent Notice :Dentium USA products are protected by patents issued by the United States of America and other countries.

SuperLine & Implantium Product Catalog66

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 67

Page 67: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

Copyright 2012. DENTIUMUSA

Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 68

Page 68: SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine & Implantium Product Catalog 07 B • The conical hex connection between implant and abutment

L.A. Office / MFG6761 Katella Ave. Cypress, CA 90630 Tel. 1-877-304-6752 Fax. 714-226-0019N.Y. Office180 Sylvan Ave. Englewood Cliffs, NJ 07632 Tel. 201-402-1390 Fax 201-731-3042Website / E-mailwww.dentiumusa.com , [email protected]

®™SuperLine & ImplantiumProduct Catalog

Specifications are subject to change without prior notice. Some products to be launched in the market after necessary approvals are also listed in this catalog.

PN2432 - 03

Product Catalog Final 2012_Layout 1 9/11/12 8:45 AM Page 1