sunsys xtend ess n tys rt energy storage system architecture · a completely integrated energy...

2
Smart Grid LV innovations Extendable installation SUNSYS XTEND ESS enables modular flexibility later on. This solution may evolve and extend at a later date by adding additional SUNSYS PCS² and/or batteries with their associated protection equipment. Compact design SUNSYS XTEND ESS is a designed compact installation, either indoors, or in a weather-tight outdoor enclosure. The complete system includes: SUNSYS PCS 2 bidirectional power converters Batteries AC distribution cabinet String Battery Coupling Panel (SBCP) Customer oriented services SUNSYS XTEND ESS offers services dedicated to commercial and industrial installations. This system is a fundamental component in providing peak shaving, load shifting and photovoltaic self-consumption functionalities in association with an external EMS. SUNSYS XTEND ESS combines lithium ion batteries with Socomec’s Power Converters to offer a completely integrated Energy Storage System, optimized for use in commercial and industrial applications. This architecture can be combined with third-party software to provide the widest range of energy services. The solution for > Commercial applications > Industrial applications Strong points > Extendable installation > Compact design > Customer oriented services > Simplified logistics Conformity to standards > EN 62477-1: Safety requirements for power electronic converter systems and equipment. > IEC 62619: Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications. > CEI 0-16, CEI 0-21, VDE AR N 4105, VDE 0126-1-1/A1: Reference technical rules for the connection of genera- ting plant to the distribution systems. SUNSYS Xtend ESS Energy Storage System architecture

Upload: others

Post on 08-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SUNSYS Xtend ESS N TYS RT Energy Storage System architecture · a completely integrated Energy Storage System, optimized for use in commercial and industrial applications. This architecture

Smar

t Grid

LV

inno

vatio

ns

Extendable installation SUNSYS XTEND ESS enables modular flexibility later on. This solution may evolve and extend at a later date by adding additional SUNSYS PCS² and/or batteries with their associated protection equipment.

Compact designSUNSYS XTEND ESS is a designed compact installation, either indoors, or in a weather-tight outdoor enclosure.The complete system includes: • SUNSYS PCS2 bidirectional power

converters• Batteries• AC distribution cabinet• String Battery Coupling Panel (SBCP)

Customer oriented servicesSUNSYS XTEND ESS offers services dedicated to commercial and industrial installations. This system is a fundamental component in providing peak shaving, load shifting and photovoltaic self-consumption functionalities in association with an external EMS.

SUNSYS XTEND ESS combines lithium ion batteries with Socomec’s Power Converters to offer a completely integrated Energy Storage System, optimized for use in commercial and industrial applications. This architecture can be combined with third-party software to provide the widest range of energy services.

The solution for

> Commercial applications> Industrial applications

Strong points

> Extendable installation> Compact design > Customer oriented services > Simplified logistics

Conformity to standards

> EN 62477-1: Safety requirements for power electronic converter systems and equipment.

> IEC 62619: Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications.

> CEI 0-16, CEI 0-21, VDE AR N 4105, VDE 0126-1-1/A1: Reference technical rules for the connection of genera-ting plant to the distribution systems.

SUNSYS Xtend ESSEnergy Storage System architecture

SUNSYS Xtend ESS Energy Storage System architecture

N TYS RTfrom 1000 to 3000 VA

Single-phase UPS

SUNSYS XTEND ESS creates a complete solution with a limited number of references for easy ordering and covering a wide range of configurations, power and back-up time.

Simplified logistics

Characteristics

Possible SUNSYS Xtend ESS architectures

Dimensions

Architecture based on SUNSYS PCS2 33TR

SUNSYS PCS2 66TR

SUNSYS PCS2 100TR

SUNSYS PCS2 66TL

SUNSYS PCS2 100TL

INPUT (DC)Battery chemistry Lithium-IonNumber of independent power modules 1 2 3 2 3

OUTPUT (AC)Rated apparent power 33,000 VA 66,000 VA 100,000 VA 66,000 VA 100,000 VA

Rated voltage (Un) 400 V rms 3ph 280 V rms 3phVoltage range 320 - 480 V rms 3ph 224 - 336 V rms 3phRated frequency (Fn) 50 HzFrequency range 47.5 - 51.5 HzMaximum efficiency ≥ 96 %

ENVIRONMENTEnvironmental category Non-air-conditionned indoor spaceDegree of protection IP 20Operating ambiant temperature -5 to + 40 °C

CERTIFICATIONSPower converter EN 62477-1Battery IEC 62619Grid codes CEI 0-16 - CEI 0-21 - VDE AR N 4105 - VDE 0126-1-1/A1

Number of SUNSYS PCS2 (1) Number of batteries Dimensions

(W x D x H) (mm)1 1 1420 x 930 x 23001 2 1940 x 930 x 23001 3 2460 x 930 x 23001 4 2980 x 930 x 23002 2 2540 x 930 x 23002 3 3060 x 930 x 23002 4 3580 x 930 x 23002 5 4100 x 930 x 23002 6 4620 x 930 x 23002 7 5140 x 930 x 23003 2 3140 x 930 x 23003 3 3660 x 930 x 23003 4 4180 x 930 x 23003 5 4700 x 930 x 23003 6 5220 x 930 x 23003 7 5740 x 930 x 23003 8 6260 x 930 x 23004 3 4260 x 930 x 23004 4 4780 x 930 x 23004 5 5300 x 930 x 23004 6 5820 x 930 x 23004 7 6340 x 930 x 23004 8 6860 x 930 x 2300

Power (kW) Architecture Product description Reference33 With transformer SUNSYS PCS² 33TR SUN-ES33KTR20RP

66With transformer SUNSYS PCS² 66TR SUN-ES66KTR20RPTransformerless SUNSYS PCS² 66TL SUN-ES66KET20RP

100With transformer SUNSYS PCS² 100TR SUN-ES100TR20CETransformerless SUNSYS PCS² 100TL SUN-ES100ET20RP

Batteries1 x 137 kWh 2 x 137 kWh 3 x 137 kWh 4 x 137 kWh 5 x 137 kWh 6 x 137 kWh 7 x 137 kWh 8 x 137 kWh

SU

NS

YS

PC

S2

1 x 33 kW • - - - - - - -1 x 66 kW • • • - - - - -2 x 66 kW - • • • • - - -3 x 66 kW - • • • • • • -4 x 66 kW - - • • • • • •1 x 100 kW • • • • - - - -2 x 100 kW - • • • • • • -3 x 100 kW - - • • • • • •4 x 100 kW - - - • • • • •

Type of cabinet ReferenceMaster protection cabinet 74401 00000Slave protection cabinet 74421 00000

String Battery Coupling Panel (SBCP)

Energy (kWh) Battery type Reference137 Energy 73101 37000

BatteriesBidirectional Power Converters - SUNSYS PCS²

Reference74310 XXX01

AC distribution cabinet

up to 8up to 4

SUNSYS Xtend ESSEnergy Storage System architecture

(1) Except for 100 kW with transformer.

Page 2: SUNSYS Xtend ESS N TYS RT Energy Storage System architecture · a completely integrated Energy Storage System, optimized for use in commercial and industrial applications. This architecture

Smar

t Grid

LV

inno

vatio

ns

Extendable installation SUNSYS XTEND ESS enables modular flexibility later on. This solution may evolve and extend at a later date by adding additional SUNSYS PCS² and/or batteries with their associated protection equipment.

Compact designSUNSYS XTEND ESS is a designed compact installation, either indoors, or in a weather-tight outdoor enclosure.The complete system includes: • SUNSYS PCS2 bidirectional power

converters• Batteries• AC distribution cabinet• String Battery Coupling Panel (SBCP)

Customer oriented servicesSUNSYS XTEND ESS offers services dedicated to commercial and industrial installations. This system is a fundamental component in providing peak shaving, load shifting and photovoltaic self-consumption functionalities in association with an external EMS.

SUNSYS XTEND ESS combines lithium ion batteries with Socomec’s Power Converters to offer a completely integrated Energy Storage System, optimized for use in commercial and industrial applications. This architecture can be combined with third-party software to provide the widest range of energy services.

The solution for

> Commercial applications> Industrial applications

Strong points

> Extendable installation> Compact design > Customer oriented services > Simplified logistics

Conformity to standards

> EN 62477-1: Safety requirements for power electronic converter systems and equipment.

> IEC 62619: Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications.

> CEI 0-16, CEI 0-21, VDE AR N 4105, VDE 0126-1-1/A1: Reference technical rules for the connection of genera-ting plant to the distribution systems.

SUNSYS Xtend ESSEnergy Storage System architecture

SUNSYS Xtend ESS Energy Storage System architecture

N TYS RTfrom 1000 to 3000 VA

Single-phase UPS

SUNSYS XTEND ESS creates a complete solution with a limited number of references for easy ordering and covering a wide range of configurations, power and back-up time.

Simplified logistics

Characteristics

Possible SUNSYS Xtend ESS architectures

Dimensions

Architecture based on SUNSYS PCS2 33TR

SUNSYS PCS2 66TR

SUNSYS PCS2 100TR

SUNSYS PCS2 66TL

SUNSYS PCS2 100TL

INPUT (DC)Battery chemistry Lithium-IonNumber of independent power modules 1 2 3 2 3

OUTPUT (AC)Rated apparent power 33,000 VA 66,000 VA 100,000 VA 66,000 VA 100,000 VA

Rated voltage (Un) 400 V rms 3ph 280 V rms 3phVoltage range 320 - 480 V rms 3ph 224 - 336 V rms 3phRated frequency (Fn) 50 HzFrequency range 47.5 - 51.5 HzMaximum efficiency ≥ 96 %

ENVIRONMENTEnvironmental category Non-air-conditionned indoor spaceDegree of protection IP 20Operating ambiant temperature -5 to + 40 °C

CERTIFICATIONSPower converter EN 62477-1Battery IEC 62619Grid codes CEI 0-16 - CEI 0-21 - VDE AR N 4105 - VDE 0126-1-1/A1

Number of SUNSYS PCS2 (1) Number of batteries Dimensions

(W x D x H) (mm)1 1 1420 x 930 x 23001 2 1940 x 930 x 23001 3 2460 x 930 x 23001 4 2980 x 930 x 23002 2 2540 x 930 x 23002 3 3060 x 930 x 23002 4 3580 x 930 x 23002 5 4100 x 930 x 23002 6 4620 x 930 x 23002 7 5140 x 930 x 23003 2 3140 x 930 x 23003 3 3660 x 930 x 23003 4 4180 x 930 x 23003 5 4700 x 930 x 23003 6 5220 x 930 x 23003 7 5740 x 930 x 23003 8 6260 x 930 x 23004 3 4260 x 930 x 23004 4 4780 x 930 x 23004 5 5300 x 930 x 23004 6 5820 x 930 x 23004 7 6340 x 930 x 23004 8 6860 x 930 x 2300

Power (kW) Architecture Product description Reference33 With transformer SUNSYS PCS² 33TR SUN-ES33KTR20RP

66With transformer SUNSYS PCS² 66TR SUN-ES66KTR20RPTransformerless SUNSYS PCS² 66TL SUN-ES66KET20RP

100With transformer SUNSYS PCS² 100TR SUN-ES100TR20CETransformerless SUNSYS PCS² 100TL SUN-ES100ET20RP

Batteries1 x 137 kWh 2 x 137 kWh 3 x 137 kWh 4 x 137 kWh 5 x 137 kWh 6 x 137 kWh 7 x 137 kWh 8 x 137 kWh

SU

NS

YS

PC

S2

1 x 33 kW • - - - - - - -1 x 66 kW • • • - - - - -2 x 66 kW - • • • • - - -3 x 66 kW - • • • • • • -4 x 66 kW - - • • • • • •1 x 100 kW • • • • - - - -2 x 100 kW - • • • • • • -3 x 100 kW - - • • • • • •4 x 100 kW - - - • • • • •

Type of cabinet ReferenceMaster protection cabinet 74401 00000Slave protection cabinet 74421 00000

String Battery Coupling Panel (SBCP)

Energy (kWh) Battery type Reference137 Energy 73101 37000

BatteriesBidirectional Power Converters - SUNSYS PCS²

Reference74310 XXX01

AC distribution cabinet

up to 8up to 4

SUNSYS Xtend ESSEnergy Storage System architecture

(1) Except for 100 kW with transformer.

dc

g 1

4202

3

Non contractual document. © 2017, Socomec SA. All rights reserved.

VALID FOR FRANCE VALID FOR ITALY

ISO 9001FM 28237

ISO14001EMS 553476