sunny island 4548-us / 6048-us - hengs · sunny island 4548-us / 6048-us the efficient off-grid...

4
SUNNY ISLAND 4548-US / 6048-US SI 4548-US-10 / 6048-US-10 Efficient • Maximum efficiency: 96 % • CEC efficiency: 94 % and 94.5 % • State of Charge Calculation • Intelligent battery management for longer battery lifespan Flexible • For Sunny Island systems from 2 to 100 kW • Single, 120/240 V split-phase and three-phase operation, connectable in parallel and modu- larly expandable Durable • Extreme overload capability • OptiCool active temperature management system • 5-year standard warranty Simple • Easy commissioning with the “Quick Configuration Guide” • Complete off-grid management • Excellent for grid-tied battery back up SUNNY ISLAND 4548-US / 6048-US The efficient off-grid manager — now with 20 percent more power The new SMA Sunny Island 4548-US and 6048-US inverters are based on the proven off-grid technology in the Sunny Island 5048-US but now feature 20 percent more power output. A maximum efficiency of 96 percent ensures peak production, which results in reduced diesel usage and makes a smaller dimensioning of the PV array possible. The new Sunny Island with two different power ratings enable more flexible system sizing. And, with multicluster technology, up to 12 Sunny Islands can be integrated into off-grid power systems up 100 kW in size.

Upload: others

Post on 14-Jul-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sunny Island 4548-US / 6048-US - Hengs · SUNNY ISLAND 4548-US / 6048-US The efficient off-grid manager — now with 20 percent more power The new SMA Sunny Island 4548-US and 6048-US

SUNNY ISLAND 4548-US / 6048-USSI

454

8-US

-10

/ 604

8-US

-10

Efficient •Maximumefficiency:96%•CECefficiency:94%and94.5%•StateofChargeCalculation•Intelligentbatterymanagement forlongerbatterylifespan

Flexible •ForSunnyIslandsystemsfrom 2to100kW•Single,120/240Vsplit-phase

andthree-phaseoperation,connectableinparallelandmodu-larlyexpandable

Durable •Extremeoverloadcapability•OptiCoolactivetemperature

managementsystem•5-yearstandardwarranty

Simple •Easycommissioningwiththe

“QuickConfigurationGuide”•Completeoff-gridmanagement•Excellentforgrid-tiedbattery backup

SUNNY ISLAND 4548-US / 6048-US The efficient off-grid manager — now with 20 percent more power

ThenewSMASunnyIsland4548-USand6048-USinvertersarebasedontheprovenoff-gridtechnologyintheSunnyIsland5048-USbutnowfeature20percentmorepoweroutput.Amaximumefficiencyof96percentensurespeakproduction,whichresultsinreduceddieselusageandmakesasmallerdimensioningofthePVarraypossible.ThenewSunnyIslandwithtwodifferentpowerratingsenablemoreflexiblesystemsizing.And,withmulticlustertechnology,upto12SunnyIslandscanbeintegratedintooff-gridpowersystemsup100kWinsize.

Page 2: Sunny Island 4548-US / 6048-US - Hengs · SUNNY ISLAND 4548-US / 6048-US The efficient off-grid manager — now with 20 percent more power The new SMA Sunny Island 4548-US and 6048-US

SUNNY ISLAND 4548-US / 6048-US

Page 3: Sunny Island 4548-US / 6048-US - Hengs · SUNNY ISLAND 4548-US / 6048-US The efficient off-grid manager — now with 20 percent more power The new SMA Sunny Island 4548-US and 6048-US

Split-phasesystem Single-phasesystem

AC output (loads)NominalACvoltage/adjustableNominalACfrequency/adjustableContinuousACpowerat25°C/40°C(77°F/113°F)for3hContinuousACpowerat25°C(77°F)ACpowerat25°C(77°F)for30min/1min/3sNominalACcurrent/max.ACcurrent(peak)THDoutputvoltage/powerfactoratratedpowerAC input (generator or grid)ACinputvoltage/rangeACinputfrequency/rangeMax.inputcurrent/adjustableMax.inputpowerBattery DC inputBatteryvoltage/rangeMax.batterychargingcurrent/continuouschargingcurrentat25°C(77°F)Batterytype/batterycapacityChargecontrolDCbreakerrating/max.Efficiency / self-consumption Max.efficiency/CECefficiencySelfconsumptionwithnoload/standbyProtectionDCreversepolarityprotection/DCfuseACshortcircuit/ACoverloadOvertemperature/batterydeepdischargeGeneral dataDimensions(W/H/D)

WeightOperatingtemperaturerangeDegreeofprotection(accordingtoIEC60529)Features / functionOperation&display/multifunctionalrelay3-phasesystems/parallelconnectionIntegratedbypass/multiclusteroperationStateofchargecalculation/fullcharge/equalizationchargeIntegratedsoftstart/generatorsupportBatterytemperaturesensor/communicationlinesWarranty:5yearsCertificatesandapprovalsAccessoriesBatterycable/batteryfuseInterface(RS485/MulticlusterPB)Extendedgeneratorstart“GenMan”Load-sheddingcontactors/externalbatterycurrentmeasurement

●Standardfeatures ○Optional —NotavailableTypedesignation

120V/105V–132V60Hz/55Hz…65Hz

5000W/4000W4500W

5300W/8400W/11000W37.5A/180Aforapprox.60ms

3%/-1…+1

120V/80V–150V60Hz/54Hz…66Hz

56A/0A…56A6.7kW

48V/41V–63V100A/85A

Lead,NiCd/100Ah…10000AhIUoUprocess

2x125A/250A

96%/94.5%25W/4W

●/●●/●●/●

467/612/235mm(18.4/24.1/9.3inch)

63kg/139lb-25°C…+60°C/-13°F…+122°F

Interiorassembly(NEMA1)

Internal/2●/●—/●

●/●/●●/●●/●

●www.SMA-Solar.com

○/○○/○

○○/○

SI4548-US-10

120V/105V–132V60Hz/55Hz…65Hz

6000W/5000W5750W

7000W/8400W/11000W48A/180Aforapprox.60ms

3%/-1…+1

120V/80V–150V60Hz/54Hz…66Hz

56A/0A…56A6.7kW

48V/41V–63V130A/110A

Lead,NiCd/100Ah…10000AhIUoUprocess

2x125A/250A

96%/94%25W/4W

●/●●/●●/●

467/612/235mm(18.4/24.1/9.3inch)

63kg/139lb-25°C…+60°C/-13°F…+122°F

Interiorassembly(NEMA1)

Internal/2●/●—/●

●/●/●●/●●/●

●www.SMA-Solar.com

○/○○/○

○○/○

SI6048-US-10

Technical Data Sunny Island 4548-US

Sunny Island 6048-US

Page 4: Sunny Island 4548-US / 6048-US - Hengs · SUNNY ISLAND 4548-US / 6048-US The efficient off-grid manager — now with 20 percent more power The new SMA Sunny Island 4548-US and 6048-US

SMA Solar Technologywww.SMA-Solar.com

SI45

48_6

048U

-DEN

1315

12S

MAan

dSu

nnyI

sland

arere

gister

edtrad

emarksofS

MASo

larTe

chno

logyA

G.B

luetoo

th® isaregis

tered

trad

emarko

fBlue

tooth

SIG,In

c..SUN

CLIX

isaregis

tered

trad

emarko

fPHO

ENIX

CONTA

CTG

mbH

&Co

.KG.T

exta

ndillustra

tionsre

flect

thecu

rrent

state

ofth

etec

hnolo

gyatth

etim

eofpub

licati

on.S

ubjec

ttote

chnic

alch

ange

s.W

eac

cept

nolia

bilityfo

rany

typo

grap

hical

errors.N

olia

bilityfo

rprin

tingerrors.Pr

inted

onc

hlorin

e-freepa

per.

SMA OFF-GrID CONFIGUrATOrDesign and Simulation Program for Off-Grid Systems