SCMV_Mon-IEN094210 | 98-4026110 | Version 1.0 EN Central inverter with medium-voltage connection SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / 1000MV / 1250MV Mounting Instructions for station supplier

Upload: others

Post on 24-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SCMV_Mon-IEN094210 | 98-4026110 | Version 1.0 EN

Central inverter with medium-voltage connectionSUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / 1000MV / 1250MVMounting Instructions for station supplier

Page 2: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist
Page 3: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Table of Contents

Mounting Instructions SCMV_Mon-IEN094210 3

Table of Contents1 Notes on this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.1 Area of Validity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.2 Target Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.3 Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.4 Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.1 Appropriate Usage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.2.1 Personnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72.2.2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72.2.3 Electrical Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

3 The Sunny Central MV Station . . . . . . . . . . . . . . . . . . . . . . 94 Delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104.1 Project-related Scope of Delivery . . . . . . . . . . . . . . . . . . . . . . . 104.2 Identifying the Delivery Components . . . . . . . . . . . . . . . . . . . . 114.3 Checking for Transport Damage. . . . . . . . . . . . . . . . . . . . . . . . 114.4 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114.5 Assembling an MV Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175.1 Preparation of the Mounting Surface . . . . . . . . . . . . . . . . . . . . 175.1.1 Preparation of Sunny Central fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175.1.2 Prepare Cable Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185.2 Preparing the Rear Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195.2.1 Preparation of Sunny Central fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195.2.2 Prepare the Air Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205.3 Installing the Sunny Central . . . . . . . . . . . . . . . . . . . . . . . . . . . 225.3.1 Fasten the Sunny Central to the Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Page 4: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Table of Contents SMA Solar Technology AG

4 SCMV_Mon-IEN094210 Mounting Instructions

5.3.2 Fasten the Sunny Central to the Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235.3.3 Mount Air Scoops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245.4 Mount the Enclosure of the Station Sub-distribution . . . . . . . . . 275.5 Mount the COM-B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285.6 Install Internal Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295.6.1 Install Switch Disconnector with Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295.6.2 Mount the Internal Power Supply Transformer . . . . . . . . . . . . . . . . . . . . . . . 305.7 Install the Medium Voltage Transformer . . . . . . . . . . . . . . . . . . 325.8 Install the Medium-voltage Switchgear . . . . . . . . . . . . . . . . . . . 356 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376.1 Connect Sunny Central to the Medium-Voltage Transformer . . 376.1.1 Guide the AC Cable to the Medium-Voltage Transformer . . . . . . . . . . . . . . 386.1.2 Connect the AC Cable to the Medium-Voltage Transformer. . . . . . . . . . . . . 396.2 Connecting the Internal Power Supply . . . . . . . . . . . . . . . . . . . 416.3 Connect the Communication Cabling to COM-B . . . . . . . . . . . 436.3.1 COM-B Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436.4 Install Emergency Stop Circuit . . . . . . . . . . . . . . . . . . . . . . . . . 437 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Page 5: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Notes on this Guide

Mounting Instructions SCMV_Mon-IEN094210 5

1 Notes on this Guide1.1 Area of ValidityThis guide describes the installation of Sunny Central and additional project-related components in a Sunny Central MV (Medium Voltage) station for connection to a medium-voltage grid.

1.2 Target GroupThe guide is intended for the station supplier commissioned with constructing the MV station.

1.3 Additional InformationAll guide for the Sunny Central MV station as well as for the installed components must be stored together with the system documentation and must be accessible at all times. The documents listed below are included in the delivery of your Sunny Central MV station. The following information is contained in these documents.

• Mounting Instructions: Mounting the Sunny Central in an MV station• Installation guide: Installing the Sunny Central MV station at the final installation

location.• Transportation and

installation requirements:Transportation options and conditions at the Sunny Central MV station installation location.

• Circuit diagram: Variant circuit diagram of the Sunny Central MV station• Additional documentation: Project-related documentation

• Sunny Central• COM-B• External Sensors• Internal power supply (SCAS, Sunny Central Auxiliary

Supply)• Station Subdistribution (STSD)• Medium-voltage transformer• Medium-voltage switchgear

Page 6: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Notes on this Guide SMA Solar Technology AG

6 SCMV_Mon-IEN094210 Mounting Instructions

1.4 Symbols UsedThe following types of safety instructions and general information appear in this document as described below:

DANGER!

DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING!

WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION!

CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE!

NOTICE indicates a situation that can result in property damage, if not avoided.

InformationInformation provides tips that are valuable for the optimal installation and operation of your product.

Page 7: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Safety

Mounting Instructions SCMV_Mon-IEN094210 7

2 Safety2.1 Appropriate UsageThe MV station is a PV inverter. It allows photovoltaic solar energy from solar modules to be converted and fed into a medium-voltage grid.

2.2 Safety InstructionsFailures that affect or limit the safety of the device must be rectified immediately. Unauthorized modifications and the use of spare parts not recommended by SMA Solar Technology may cause fire, material damage and electrical shock. Unauthorized personnel must not have access to the devices.Warning signs must always be clearly readable and immediately replaced if damaged.

2.2.1 PersonnelOnly qualified technical personnel may perform work on the MV station. "Qualified" means that the personnel must possess training relevant to the activity performed and must be familiar with the content of this guide.

2.2.2 InstallationThe requirements for the installation site, which are described in the Sunny Central installation requirements and in the MV station transportation and installation requirements, must be observed.

Page 8: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Safety SMA Solar Technology AG

8 SCMV_Mon-IEN094210 Mounting Instructions

2.2.3 Electrical ConnectionThe electrical connection must be performed according to this installation guide, the variant circuit diagram and the technical data of the device.Ensure the grid connection cable for grid feeding is fused at the nominal current indicated on the type plate. If the specified nominal current differs from the nominal current of the fuse plug, the fuse plug having the next highest nominal current may be used.

Lightning protectionThe devices have internal overvoltage protection on the AC and DC sides. However, the desired protection level can only be achieved if a lightning protection area concept exists for the installation building as per DIN VDE 0185-4, i.e. lightning conductors or combined surge and lightning conductors (not included in scope of delivery) are available at, among other locations, the building’s entrance (transfer lightning protection area LPZ 1).Combined overvoltage and lightning protection for the signal inputs can be optionally ordered.Emergency StopIn systems having more than one device, the respective emergency stop switches must be connected together as described in this installation guide. The emergency stop circuit may only be supplied with voltage from a single device.

Grid connection cableThe grid connection cable for the internal power supply must be secured with the line circuit breaker specified in the technical data. SMA Solar Technology recommends to use thermal fuses for this purpose.

Emergency Stop Circuit• The emergency stop circuit may only be supplied by a Sunny Central.• Ensure correct mounting of the jumpers on the emergency stop terminal strip of the

device. Please refer to the circuit diagram for detailed information.

Page 9: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG The Sunny Central MV Station

Mounting Instructions SCMV_Mon-IEN094210 9

3 The Sunny Central MV StationA MV station is generally a concrete substation with two chambers. One chamber contains the inverters, the station sub-distribution, and the communication technology. The other chamber contains the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply.A medium-voltage connection can consist of 1 or 2 central inverters, a COM-B as communication connection, a station sub-division (STSD), a medium-voltage transformer, a medium-voltage switchgear, and an internal power supply comprised of a switch disconnector with a fuse and an internal power supply transformer.The figure below depicts a fully-equipped station and its components. The exact assembly and components of an MV station depend on the project.

Page 10: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Delivery SMA Solar Technology AG

10 SCMV_Mon-IEN094210 Mounting Instructions

4 Delivery4.1 Project-related Scope of Delivery

Position Number DescriptionA 1 Sunny CentralB 1 Medium voltage transformerC 1 Medium-voltage switchgearD 1 MV station documentation

E1E2E3

111

Internal power supply (SCAS, Sunny Central Auxiliary Supply)• Internal power supply transformer• Switch disconnector with fuse• Connection cabling

F 1 COM-BG 1 Station Subdistribution (STSD)H 1 External Sensors

Page 11: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Delivery

Mounting Instructions SCMV_Mon-IEN094210 11

The following MV stations are equipped with one Sunny Central:• SC 400MV• SC 500MV• SC 630MV

The following MV stations are equipped with two Sunny Centrals:• SC 800MV• SC 1000MV• SC 1250MV

For exact delivery scope of the Sunny Central, COM-B, the external sensors and the other components, refer to the corresponding installation guide.

4.2 Identifying the Delivery ComponentsThe individual components in the delivery can be identified by the type plates of the individual devices. The location of the type plates can be found in the project documentation.

4.3 Checking for Transport DamageCheck the packaging and the devices for any damage and compare the scope of delivery with the delivery documentation. In the case of damage to the devices and/or unclear delivery contents, immediately contact the SMA Solar Technology project manager.

4.4 StorageThe instructions for storage listed in the product documentation must be observed.

Page 12: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Delivery SMA Solar Technology AG

12 SCMV_Mon-IEN094210 Mounting Instructions

4.5 Assembling an MV StationThe HE series Sunny Central units are normally set up in a concrete substation, opposite to each other as a “left-hand system” and a “right-hand system”. The installation has to be carried out in accordance with the VDE guidelines for a closed electrical operating room. The figure below depicts a left-hand and a right-hand system.

The AC cabinet should always stand next to the partition wall to the transformer room so that the AC power cables can be connected to the transformer via the shortest possible route.

Left system Right system

A DC cabinetB Inverter cabinetC AC cabinet

WARNING!Smoke Emission in Electrical Operating Rooms.

We recommend the installation of a smoke detector inside the operating room which controls the external emergency stop connection of the device and which switches off the Sunny Central in the event of smoke.

Page 13: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Delivery

Mounting Instructions SCMV_Mon-IEN094210 13

Sunny Centrals in a StationA selection of schematic top views of a Sunny Central installed in a station and a transformer room are included below. The figure above shows the inverter installed as a “right-hand system”, while the figure below depicts a “left-hand system”. A station may also include only one Sunny Central. In addition to a transformer, the transformer room also contains an optional medium-voltage switchgear and the transformer for the internal power supply. MV station with two Sunny Centrals without medium-voltage switchgear

A AC cabinetB Inverter cabinetC DC cabinetD Station sub-distributionE COM-BF Medium voltage transformer

Page 14: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Delivery SMA Solar Technology AG

14 SCMV_Mon-IEN094210 Mounting Instructions

MV station with two Sunny Centrals and medium-voltage switchgear

A AC cabinetB Inverter cabinetC DC cabinetD Station sub-distributionE COM-BF Medium voltage transformerG Medium-voltage switchgear

Page 15: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Delivery

Mounting Instructions SCMV_Mon-IEN094210 15

MV station with one Sunny Central without medium-voltage switchgear

A AC cabinetB Inverter cabinetC DC cabinetD Station sub-distributionE COM-BF Medium voltage transformer

Page 16: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Delivery SMA Solar Technology AG

16 SCMV_Mon-IEN094210 Mounting Instructions

MV station with one Sunny Central with medium-voltage switchgear

A AC cabinetB Inverter cabinetC DC cabinetD Station sub-distributionE COM-BF Medium voltage transformerG Medium-voltage switchgear

Page 17: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 17

5 InstallationThe Sunny Central devices must be fixed to the floor and the rear wall of a station. This will prevent the Sunny Central from tipping over when the station is transported.

5.1 Preparation of the Mounting Surface

5.1.1 Preparation of Sunny Central fixingThe Sunny Central must be fixed to the floor of the station. The station floor is laid out by the station construction staff. The floor can be poured concrete or steel struts. SMA Solar Technology recommends a steel strut floor. Coverings on the steel struts make it easier to access the cable chamber and install the inverter and the remaining devices in the station. The figure below depicts the concrete substation floor layout recommended by SMA Solar Technology.

Page 18: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

18 SCMV_Mon-IEN094210 Mounting Instructions

5.1.2 Prepare Cable EntryThe figure below depicts a top view of the Sunny Central floor group with the DC cabinet on the left and the AC cabinet on the right. The mounting conditions for Sunny Central contain additional information regarding the position of the components in Sunny Central and the appropriate cable entry.

Prepare DC cable entryThe DC cable is inserted into the Sunny Central DC cabinet through the cable vault by the end customer at the mounting site. When using a concrete floor in the DC cabinet, include openings for the cables.Prepare the grounding cabling entryThe grounding cabling is inserted into the Sunny Central DC cabinet through the cable vault by the end customer at the mounting site. When using a concrete floor in the Sunny Central, include openings for the cables.Inserting the communication cabling and the internal power supplyThe communication cabling and the internal power supply are inserted into the Sunny Central AC cabinet through the cable vault. When using a concrete floor in the AC cabinet, include openings for the cables.Openings for the cabling in the MV station intermediate floorThe figure below depicts the position of the DC cable feed-throughs and the communication and internal power supply feed-throughs.

Page 19: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 19

5.2 Preparing the Rear Wall

5.2.1 Preparation of Sunny Central fixingThe Sunny Central must be fixed to the wall of the station.

The figure below is a schematic representation of the station and the mounting points on the station wall and floor.

Mark the mounting points on the floor The Sunny Central mounting instructions describe the exact positions for the mounting points on the floor.

Page 20: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

20 SCMV_Mon-IEN094210 Mounting Instructions

5.2.2 Prepare the Air OutletThe air scoops are mounted on the Sunny Central; see 5.3.3 ”Mount Air Scoops” (page 24). After mounting the Sunny Central in the station, fit the air scoops to the air outlets.Alternatively, some air scoop parts can be mounted on the concrete substation before the Sunny Central is installed; see ”Mount the air baffle on the concrete substation” (page 21).The figure below is a schematic representation of the station and the air outlets for a Sunny Central.

Page 21: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 21

Prepare the air outlets on the power module

Prepare the switch cabinet air outlets

Prepare the anchors of the air scoops for air output• Insert wall anchors.

Mount the air baffle on the concrete substationThe air baffle allows the air to escape.1. Mount the angular sheet on the seal at the bottom edge of the ventilation grid.

The angular sheet is not included in the delivery.2. Mount the seal on the free side of the angular sheet.

The seal is not included in the delivery.

Switch cabinet air outletsThe precise dimensions of the air outlets for the individual Sunny Central switch cabinets can be derived from the size and position of the fans and their pressure reserves in the Sunny Central mounting instructions.

Seal the air outlets.Affix a sealing strip to the edges of the air outlets.

Page 22: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

22 SCMV_Mon-IEN094210 Mounting Instructions

5.3 Installing the Sunny CentralThe Sunny Central installation guide describes how to mount the individual switch cabinet components.

5.3.1 Fasten the Sunny Central to the FloorThe figure below is a schematic representation of a Sunny Central installation.

1. Set up Sunny Central.2. Affix Sunny Central to the floor with suitable screws.

The screws are not included in the delivery.3. Check that the device is securely in place.

Page 23: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 23

5.3.2 Fasten the Sunny Central to the Wall1. Fasten the Sunny Central to the wall with a bracket.

Mounting material is not included in the delivery.2. Check that the device is securely in place.☑ The Sunny Central is installed.

Page 24: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

24 SCMV_Mon-IEN094210 Mounting Instructions

5.3.3 Mount Air ScoopsFasten the air scoops to the prepared points on the roof of the Sunny Central.The figure below is a schematic representation of the installation of the air scoops on a Sunny Central.

1. Mount the seal between the Sunny Central and the air scoop. The seal is not included in the delivery

2. Mount the scoops on the Sunny Central.

NOTICE!Damage to the device due to short circuits.

Do not drill into the switch cabinets. Waste material can cause short circuits.Remove waste materials from the cabinet.

Page 25: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 25

3. Fasten the air scoops to the Sunny Central using the roof screws and washers. The washers are not included in the delivery.

4. Make sure that the device is securely in place.5. Check the seals on the air scoops.6. If necessary, seal any air gaps with sealing compound.☑ The air scoops are mounted.

Notice!Device damage due to improper mounting of the air scoops on the AC cabinet.

• The air scoop should only be fastened to the side of the switch cabinet that borders the side wall of the inverter cabinet.

• Place the air scoop on the switch cabinet on the AC cabling side and mount it to the Sunny Central using only the rear screw.

Page 26: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

26 SCMV_Mon-IEN094210 Mounting Instructions

Adjustment possibilities• A diagonal air scoop.

• A rectangular air scoop with an extension on the rear.

Adjust the air scoops.The air scoops may need to be adjusted on the side of the AC output.The following adjustments are possible:

Page 27: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 27

5.4 Mount the Enclosure of the Station Sub-distribution The station sub-distribution mounting is the same regardless of the MV station construction; only the position in the station may change.The figure below is a schematic depiction of the mounting location and method for the station sub-distribution using the example of an MV station with two Sunny Centrals.

Mounting in an MV station with one Sunny Central.In MV stations with only one Sunny Central, mount the station sub-distribution opposite the Sunny Central.Mounting dimensions.The dimensions of the device and the drill holes are described in the switch box manufacturer's technical documentation.

1. Mark the position of the drill holes.2. Drill the holes in the indicated positions.3. Insert wall anchors.

The wall anchors are not included in the delivery.

Page 28: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

28 SCMV_Mon-IEN094210 Mounting Instructions

5.5 Mount the COM-BThe COM-B mounting is the same regardless of the MV station construction; only the position in the station may change. The COM-B mounting is described in the COM-B technical specifications.The figures below are a schematic depiction of the mounting location and method for the COM-B using the example of an MV station with two Sunny Centrals.

4. Attach the station sub-distribution to the wall using suitable screws and washers.The screws and washers are not included in the delivery.

5. Make sure that the device is securely in place.☑ The station sub-distribution is mounted.

Mounting in an MV station with one Sunny Central.In MV stations with only one Sunny Central, mount the COM-B opposite the Sunny Central.

1. Mark the position of the drill holes.2. Drill the holes in the indicated positions.3. Insert wall anchors.

The wall anchors are not included in the delivery.

Page 29: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 29

5.6 Install Internal Supply

5.6.1 Install Switch Disconnector with Fuses

4. Fasten the COM-B to the wall using suitable screws and washers.The screws and washers are not included in the delivery.

5. Make sure that the device is securely in place.☑ The COM-B is mounted.

Mounting dimensions.The dimensions of the switch disconnectors with the fuses and the drill holes are contained in technical data of the self-sufficient transformers.

1. Mark the position of the drill holes.2. Drill the holes in the indicated positions.3. Insert wall anchors.

The wall anchors are not included in the delivery.

Page 30: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

30 SCMV_Mon-IEN094210 Mounting Instructions

5.6.2 Mount the Internal Power Supply Transformer

4. Attach the switch disconnector to the wall using suitable screws and washers.The screws and washers are not included in the delivery.

5. Make sure that the device is securely in place.☑ The switch disconnector with fuses is mounted.

Mounting locationSelect suitable mounting location. There must be free access to the cabling and the installation.Mounting dimensionsThe dimensions of the internal power supply transformer and the drill holes are contained in the internal power supply transformer technical data.

1. Mark the position of the drill holes.2. Drill the holes in the indicated positions.3. Insert wall anchors.

The wall anchors are not included in the delivery.

Page 31: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 31

4. Fasten the internal power supply transformer to the floor using suitable screws and washers.The screws and washers are not included in the delivery.

5. Make sure that the device is securely in place.☑ The internal power supply transformer is mounted.

Page 32: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

32 SCMV_Mon-IEN094210 Mounting Instructions

5.7 Install the Medium Voltage Transformer

The medium-voltage transformer is mounted either on the station floor or on rails at the height of the Sunny Central.Mounting on rails1. Mount rails to carry the medium-voltage transformers.

2. Mount support rings to the walls. The support rings serve to fasten the medium-voltage transformer. The support rings are not included in the delivery.

Medium voltage transformer installation guideObserve the manufacturer's documentation.

Page 33: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 33

3. Mount the medium-voltage transformer on the rails.

4. Fasten the medium-voltage transformer with tension belts. The tension belts are not included in the delivery.

5. Make sure that the device is securely in place.☑ The medium-voltage transformer is mounted.

Page 34: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

34 SCMV_Mon-IEN094210 Mounting Instructions

Mounting on the MV station floor

1. Insert wall anchors.The wall anchors are not included in the delivery.

2. Fasten the middle voltage transformer to the floor using suitable screws and washers.The screws and washers are not included in the delivery.

3. Make sure that the device is securely in place.☑ The medium-voltage transformer is mounted.

Secure footing for the medium-voltage transformer.Place the medium-voltage transformer on suitable rubber pads or on vibration dampers.

Page 35: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Installation

Mounting Instructions SCMV_Mon-IEN094210 35

5.8 Install the Medium-voltage Switchgear

1. Mark the position of the drill holes.2. Drill the holes in the indicated positions.

3. Insert wall anchors.The wall anchors are not included in the delivery.

4. Attach the medium-voltage switchgear to the wall using suitable screws and washers.The screws and washers are not included in the delivery.

Medium-voltage switchgear installation guideObserve the manufacturer's documentation.

Page 36: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Installation SMA Solar Technology AG

36 SCMV_Mon-IEN094210 Mounting Instructions

5. Make sure that the device is securely in place.☑ The medium-voltage switchgear is mounted.

Page 37: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Electrical Connection

Mounting Instructions SCMV_Mon-IEN094210 37

6 Electrical Connection

6.1 Connect Sunny Central to the Medium-Voltage TransformerThe Sunny Central has various connection options on the AC side. Depending on the project, the Sunny Central AC output needs to be adapted to the MV station requirements.

DANGER!There are lethal voltages at the connections when the system is in operation.

Make sure the connections are safe to touch.• The connections to the medium-voltage transformer should be fully enclosed.• The connections to Sunny Central should be protected from unintended contact with

a plexiglass cover.

AC output to Sunny CentralThe Sunny Central installation guide describes how to carry out the connection.

Page 38: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Electrical Connection SMA Solar Technology AG

38 SCMV_Mon-IEN094210 Mounting Instructions

6.1.1 Guide the AC Cable to the Medium-Voltage TransformerDepending on the MV station construction, guide the Sunny Central cabling into position at the medium-voltage transformer in accordance with the circuit diagram. The following figure is a schematic depiction of the AC connection to Sunny Central and the possible cable connections to the medium-voltage transformer.

Page 39: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Electrical Connection

Mounting Instructions SCMV_Mon-IEN094210 39

6.1.2 Connect the AC Cable to the Medium-Voltage TransformerConnect the AC line to the low-voltage side.The connection to the medium-voltage transformer must be completely insulated. The following figure is a schematic depiction of the AC connection to Sunny Central and the possible cable connections to the medium-voltage transformer.

Page 40: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Electrical Connection SMA Solar Technology AG

40 SCMV_Mon-IEN094210 Mounting Instructions

Connect the AC line to the high-voltage sideThe connection to the medium-voltage transformer must be completely insulated. The following figure is a schematic depiction of the AC connection on the medium-voltage transformer to the medium-voltage switchgear.

Page 41: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Electrical Connection

Mounting Instructions SCMV_Mon-IEN094210 41

6.2 Connecting the Internal Power SupplyThe internal power supply is provided by a Sunny Central. It comprises of a switch disconnector with fuses, an internal power supply transformer and the necessary cabling.

A Connection to Sunny Central B Load disconnection unit with fusesC Internal power supply transformer D Station sub-distribution

Page 42: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Electrical Connection SMA Solar Technology AG

42 SCMV_Mon-IEN094210 Mounting Instructions

Connect disconnection switch with fuses

1. Install the cable clamping at the transformer room.

Connect the internal power supply4. Lay the power cable of the internal power supply from the load disconnection unit with fuses to

the internal power supply transformer.5. Connect the power cable of the internal power supply to the internal power supply transformer.

Connect the power cable to the sub-distribution board6. Lay the power cable from the internal power supply transformer to the sub-distribution board.7. Connect the power cable to the station sub-distribution.

Connect the internal power supply to the Sunny Central8. Guide the connection cable through the slider plate on the floor of the AC switch cabinet.

Connection to the internal power supply on the Sunny Central The Sunny Central installation guide describes how to carry out the connection.

2. Mount the cable and cut into lengths.3. Connect the power cable of the internal power

supply to the disconnection switch.

Connecting the internal power supply to the sub-distribution boardThe circuit diagram instructions describe how to carry out the connection.

Connecting the internal power supply in the Sunny CentralThe circuit diagram instructions describe how to carry out the connection.

Page 43: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Electrical Connection

Mounting Instructions SCMV_Mon-IEN094210 43

6.3 Connect the Communication Cabling to COM-B

6.3.1 COM-B Cabling

6.4 Install Emergency Stop CircuitAn emergency-stop circuit connects Sunny Central to the external emergency stop and the medium-voltage transformer hermetic enclosure.

Connecting the internal power supply in the Sunny CentralThe circuit diagram instructions describe how to carry out the connection.

Connecting the emergency stopConnect the emergency stop in accordance with the supplied circuit diagrams.

Page 44: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Contact SMA Solar Technology AG

44 SCMV_Mon-IEN094210 Mounting Instructions

7 ContactIf you have technical problems concerning our products, please contact the responsible SMA Solar Technology project manager.We require the following information in order to provide you with the necessary assistance:

• MV station type• Project name• Customer order• Sunny Central serial number

SMA Solar Technology AG Sonnenallee 134266 Niestetal, GermanyTel. +49 561 9522 299Fax +49 561 9522 3299 [email protected] www.SMA.de

Page 45: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

SMA Solar Technology AG Contact

Mounting Instructions SCMV_Mon-IEN094210 45

Page 46: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist

Legal Restrictions SMA Solar Technology AG

46 SCMV_Mon-IEN094210 Mounting Instructions

The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission.

Exclusion of liabilityThe general terms and conditions of delivery of SMA Solar Technology AG shall apply.The content of these documents is continually checked and amended, where necessary. However, discrepancies cannot be excluded. No guarantee is made for the completeness of these documents. The latest version is available online at www.SMA.de or from the usual sales channels.Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following: • Damages during transportation• Improper or inappropriate use of the product• Operating the product in an unintended environment• Operating the product whilst ignoring relevant, statutory safety regulations in the deployment location• Ignoring safety warnings and instructions contained in all documents relevant to the product• Operating the product under incorrect safety or protection conditions• Altering the product or supplied software without authority• The product malfunctions due to operating attached or neighboring devices beyond statutory limit values• In case of unforeseen calamity or force majeureThe use of supplied software produced by SMA Solar Technology AG is subject to the following conditions:• SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by

SMA Solar Technology AG. This also applies to the provision or non-provision of support activities.• Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements

of the manufacturer.

SMA Factory WarrantyThe current guarantee conditions come enclosed with your device. These are also available online at www.SMA.de and can be downloaded or are available on paper from the usual sales channels if required.

TrademarksAll trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark.The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology is under license.SMA Solar Technology AGSonnenallee 134266 NiestetalGermanyTel. +49 561 9522-0Fax +49 561 9522-100www.SMA.deE-Mail: [email protected]© 2004 to 2010 SMA Solar Technology AG. All rights reserved

Page 47: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist
Page 48: SUNNY CENTRAL 400MV / 500MV / 630MV / 800MV / …...the medium-voltage transformer, the medium-voltage switchgear, and the internal power supply. A medium-voltage connection can consist