sun storage tek 6140 technical presentation
TRANSCRIPT
Sun StorageTek™ 6140 Array Technical Presentation
PresenterTitleSun Microsystems, Inc.
Sun Confidential: Internal Only
• Protection – you have more to lose• Performance - meeting new
application demands• Availability – more people need
access more often• Scalability – growth continues...• Flexibility – multi-purpose solutions
and options that save money• Manageability – simple, powerful,
intuitive, and low-cost
Your business is really taking off - your data is growing even faster
You need greater...
Sun Confidential: Internal Only
Sun StorageTek™ Modular Arrays and Systems
Value — get the most for your money • Cost-effective balance of
performance, availability, and scalability
• High-end features previously only available on expensive, high-end systems
• Affordable application and storage consolidation
Sun Confidential: Internal Only
Sun StorageTek™ Modular Arrays and Systems
Flexibility — easily keep up with ever-evolving applications• Non-disruptively adapt to
changing application requirements
• Data-in-place upgrade-ability across the line and across generations
• Family compatibility preserves your investment
Sun Confidential: Internal Only
Sun StorageTek™ Modular Line of Arrays and Systems
Data protection• Highly-available system design• Broad suite of data protection
software• World-class 24/7 service and
support
Sun Confidential: Internal Only
Sun StorageTek™ Modular Line
Enterprise-classdata protection
on a budgetMulti-tiered storage
Replicationtarget
Ideal fordatabase-driven
applications
Leader in price/performance
Excels in HPTCenvironments
Sun StorageTek™6140 array
Sun StorageTek™6540 array
Sun Confidential: Internal Only
What's new with the Sun StorageTek™ 6140 Array?• RoHS-compliant• Feature enhancements over earlier products:
✔ Up to 8 FC Host ports ✔ Up to 4GB cache ✔ Faster Performance
• Two model options based on✔ Host ports, cache size, performance, scalability
and data services options.• End-to-end 4Gb/second data paths• Switched Loop Architecture• About 2X the Performance of StorEdge 6130 or STK
FLX240• $20K Entry point at US List Price
✔ Includes dual RAID controllers, 2 GB cache, 4 FC host ports, 5 drives, Common Array Manager software, 4 gigabits per-second
Hot new 4 Gb/s array at the entryto the midrange!
Sun Confidential: Internal Only
Sun StorageTek 6140 Array Compared to Previous Generation
End-to-Eng 4Gb/s infrastructure YES YES NO NOCache Size (per array) 4GB 2GB 2GB 2GBMax capacity per array 56TB 32TB 43TB 4.2TB Host Ports 8 4 4 4Host Connectivity 4 or 2 or 1 Gbit FC 4 or 2 or 1 Gbit FC 2 or 1 Gbit FC 2 or 1 Gbit FC# of drives per tray Min 5 / Max 16 Min 5 / Max 16 Min 5(3 for 240) / Max 14 Min 3 / Max 14 Max # of drives per array 112 64 112 14 Disk Type FC/SATA FC/SATA FC+SATA FC OnlyFC/SATA Intermix YES YES NO NOSBOD YES YES YES NORoHS Compliant YES YES NO NO
Performance
Storage Domains (partitions) 4/8/16/64 4/8/16 16/64 4/16
Data Services Snap Shot
Management (Included) Common Array Manager Common Array Manager Common Array Manager / N/A N/A
StorageTek 6140 with 4GB cache
StorageTek 6140 with 2GB cache
StorEdge 6130/ Flexline 240
Flexline 240 Drive Limited
Cache:125K IOPs, 1500 MB/s Disk: 44k IOPs, 990 MB/s
Cache:100K IOPs, 1200 MB/s Disk: 30k IOPs, 700 MB/s
Cache:77.5K IOPs, 800 MB/s Disk: 25k IOPs, 400 MB/s
Cache:77.5K IOPs, 800 MB/s Disk: 25k IOPs, 400 MB/s
SnapShot, Volume Copy, Data Replication
SnapShot, Volume Copy, Data Replication
SnapShot, Volume Copy, Data Replication
Previous GenerationStorageTek 6140 Array
9
• 100% redundant I/O paths with auto-failover helps ensure against any application disruption
● Non-disruptive controller firmware upgrades
• Switched “SBOD” architecture enables pin-point control over back-end operations
• Battery-backed cache provides data protection in the event of power failure
• Chip-level RAID parity calculations help ensure continuous reliability of high performance RAID operations
High-quality, High-availability
10
Flexibility
• Fibre Channel and SATA Intermix
• Hot-swappable components> Disk Drives> Batteries> Controllers
• Grow seamlessly as your business grows
Data Data WarehouseWarehouse
ApplicationsApplications
OLTPOLTPApplicationsApplications
Point-in-Time Copy
F C F C F C F C SATA SATA SATA SATA
11
Flexibility
* OS-dependent
• Non-disruptive changes > Dynamic Capacity Expansion enables capacity to be easily
added to existing volume groups.> Dynamic Volume Expansion enables capacity to be easily
added to existing Volumes/LUNs*> Dynamic Virtual Disk Expansion enables raw capacity to be
added to existing V-disks> Dynamic RAID-level and Segment-size Migration allow for
changing application workloads
Sun Confidential: Internal Only
What's Hot About 4 Gb/s?• Faster access
> Reduces time to load large data sets by up to half• Faster back-ups
> Faster data transfers> Move data between tiers in less time> Faster mirroring and remote replication
• Faster restores> Restores data twice as fast
• Sun StorageTek array is end-to-end> Maximizes 2 and 4 Gb/s
Sun Confidential: Internal Only
Targeted Performance - Estimates
850650Disk Write MB/sec
990700Disk Read MB/sec
1,5001,200Cached Read MB/sec
9,0006,000Disk Write IOPs
44,00030,000Disk Read IOPs
125,000100,000Cached Read IOPs
Sun StorageTek 6140 Array 4 GB Cache
Sun StorageTek 6140 Array 2 GB Cache
14
Enterprise-level Data Protection
15
Vol A Vol A Async. LogAsync. Log Snap Pool Snap Pool
Consistency GroupConsistency Group
Vol B Vol B Vol C Vol C Vol A Vol A Snap Pool Snap Pool
Vol B Vol B Vol C Vol C
Consistency GroupConsistency Group
WAN
Sun StorageTek™ Data Replicator Software
● Synchronous replication● Asynchronous replication● Write-order consistency groups
Sun Confidential: Internal Only
Sun StorageTek™ Data Replicator Highlights• Support for synchronous & asynchronous writes
> Write order consistency option for asynchronous mirror• Support for dynamic mode switching
> Go back and forth between synchronous and asynchronous modes without breaking mirror
• Fast resynchronization of broken/suspended mirror• Access the remote volume while mirror is active
> Snap/Copy the mirror while replicating• Support for multiple mirror relationships
> 32 per STK6140 storage subsystem
17
Robust Data Protection
• Creates point-in-time image of a volume> Up to four snaps per volume
• Requires less disk space• Ideal for backup, restore,
checkpoint
Sun StorageTek™ Data Snapshot SoftwareLUN1 – SalesLUN2 – Sales BU
A' B C'E
A C
A B C
Physical Logical
BaseBaseVolumeVolumeSalesSales
SnapshotSnapshotVolumeVolume
Sales BUSales BU
SnapshotSnapshotRepositoryRepository
18
Ideal for Tiered Data Storage Strategies• Near-line data backup• OLTP, data warehouse,
e-commerce• Content management• Email, vmail• Computer generated
animation (CGA)• Service providers• Medical imaging, data acquisition
Data Data WarehouseWarehouseApplicationsApplications
OLTPOLTPApplicationsApplications
Snapshot
F C F C F C F C SATA SATA SATA SATA
500 GB SATA II
Application
19
Duplicating Data
• Completely replicates volumes– Up to 8 concurrent active
copies per source volume• Ideal for analysis, testing,
mining, enhanced backup• Migrate data
between tiers
Sun StorageTek™ Volume Copy Software
Production Server
Analysis Server
SourceSourceVolumeVolumeOrdersOrders
Data Data CloneCloneOrdersOrders
A B C A B C
20
Storage Domains
• Match applications to storage class
• Lower TCO by consolidating storage for heterogeneous hosts
• Workloads co-exist harmoniously, with minimal sharing
Simplifying Management with Storage Partitions
Unmapped Volumes
LUN0
Host A
Host B
Host Group C
StoragePartition
A
StoragePartition
B
StoragePartition
C
LUNLUN00
LUNLUN11
LUNLUN22
LUNLUN00
LUNLUN22
LUNLUN11
LUNLUN33
21
Heterogeneous Operating System Support
Sun Confidential: Internal Only
Multi-dimensional Investment Protection• Use the same software across the family and
easily upgrade from previous generations – no need to re-train staff
• Migrate seamlessly and painlessly > replicate data from old array to new array with the
array's data migration software > Data-in-place upgrades allow users to move disk
and controller trays to new systems without disrupting data
• HotScale allows FC &/or SATA drive enclosures to be non-disruptively added to existing systems.
• Instant Availability means new disks are accessible as soon as they are added to the system.
• Backward Compatibility easily incorporate existing StorEdge™ 6130 or FlexLine™ modules into new systems
23
Centralized Management UtilityCentralized Management Utility● Easily manage many 6140 arrays● Deploy by application type (Storage Profiles)● Up to 1024 volumes● RAID 0, 1+0, 1, 3, 5● Dynamic expansion● Dynamic re-configuration
Save TimeUse Storage Profiles to quickly and predictably provision storage to precise application demands.
Maximize PerformanceEasily and dynamically tune any attribute to exact application tolerances.
Grow Without DisruptionDynamically scale the volume as the application needs dictate.
Sun StorageTek™ Common Array Manager
24
Optimize System PerformanceQuickly visualize performance health, finely tune attributes to reach the optimal configuration for precise application needs.
Reduce System DowntimePerformance degradation is often a precursor to component or system downtime, performance tracking enables predictive, preemptive maintenance.
Performance Tracking UtilityPerformance Tracking Utility● Controller, volume and array statistics● Track IOPS performance● Track throughput (MB/s) performance● Track IO characteristics● Track write %, read %, cache hit %
Sun StorageTek Common Array Manager
25
Maximize System UptimeWherever you are in the world, quickly receive notification of any system health issue...quickly isolate and repair failed components.
Optimize System OperationsEasily ensure the system is running with the latest patches. Link to Sun Download Center to easily download, install, and track patches as needed.
Sun StorageTek Common Array Manager
Automated DiagnosticsAutomated Diagnostics● Set and track system alerts● Easily manage patch distribution● Embedded service diagnostics
26
Simplify System ManagementWith administrative domains, manage storage by application or targeted host/organizations.
Ensure Optimum PerformanceUse Storage Domains to unite key storage resources with critical business applications.
Storage DomainsStorage Domains● Segment storage by host/app.● Up to 64 “virtual” arrays● Heterogeneous host support● Multiple storage classes
Sun StorageTek Common Array Manager
Sun Confidential: Internal Only
What's HOT about this new array? • FASTER... applications, backup and restore,
archive, and data retrieval• Sun StorageTek™ Common Array Manager,
application-oriented management across the StorageTek 6000 Family
• Data protection - synchronous and asynchronous replication, snapshots with copy-on-write; full-volume copy
• Backwards and forwards compatibility -auto-negotiating fibre channel interfaces support new and existing gear
• Tiered storage in a single system with intermixing of up to 112 Fibre Channel or Serial ATA drives
• Maximized data center real estate with 16 disk drives per tray
• Optional SANtricity software
Sun StorageTek™ 6140 array
Sun Confidential: Internal Only
Two Great Flavors
• 6140 with 2 GB Cache> $20K entry price> 4 x 4Gb host/SAN port> 2 GB cache> Up to 3 expansion trays
> Up to 64 drives> 100K IOPS
• 6140 with 4 GB Cache> $40K entry price> 8 x 4Gb host/SAN port> 4 GB cache> Up to 6 expansion trays
> Up to 112 drives> 120K IOPS
Sun Confidential: Internal Only
Sun StorageTek 6140 Array – 2 Versions
48Host channels 2 GB Cache
4 GB
IntegratedIntel xScale 667 FC and SATA
1121,600 MB/sFour 4 Gb/s3,200 MB/s4, 2, 1 Gb/s
4 Gb/s
4 GB Cache
Native host interface link speed
Total drive channel bandwidth
Total host channel bandwidthSupported host interface link speeds
Data cache per dual-controller system
XOR engineProcessor
Drives supportedMax drives
Redundant drive channels
Sun StorageTek 6140 Array
2 GB
IntegratedIntel xScale 667 FC and SATA
641,600 MB/sFour 4 Gb/s1,600 MB/s4, 2, 1 Gb/s
4 Gb/s
Sun Confidential: Internal Only
Sun StorageTek 6140 Array – Rear View
Host InterfacesDrive Interfaces Ethernet Battery
Power/Cooling Serial Port Controllers
Sun Confidential: Internal Only
Sun StorageTek 6140 Array – Rear View
Sun Confidential: Internal Only
Controller Faceplate -6140 4GB cache
Battery (CRU) Serial Port
DualExpansion Ports
4Gb/s Host Ports
Dual Ethernet PortsLEDS, Tray Identifier
Sun Confidential: Internal Only
Supported Disk Drives • 10 K RPM FC drives
> 2 Gb/s interface> 146 GB, 300 GB
• 15 K RPM FC Drives> 4 Gb/s interface> 73 GB, 146 GB
• SATA-II drives > 500 GB capacity> Native Command Queuing> 3 Gb interface
Sun Confidential: Internal Only
Cache/Battery Notes• Cache memory is shared between system memory and
cache memory• All data cache is mirrored for controller failover• Available cache = (total cache – system memory)/2• With 2 Gb cache/controller: (2 GB – 160 MB) / 2 = 944 MB• Write back cache changes to write through mode when a
battery is removed or failed• Power Cooling Unit failure does not cause cache mode
change• Controller Failover causes cache to go into write through
mode• Data is stored in cache of 72 hours @2 GB, > 72 hours @ 1
GB• Data in cache from a power failure is de-staged when
power is returned
Sun Confidential: Internal Only
Sun StorageTek 6140 Array – Cabling
Sun Confidential: Internal Only
Sun StorageTek 6140 Array - Controllers
• Two models:> – four host ports per controller> – two host ports per controller
• Uses 667MHz Xscale processorwith embedded XOR engine
• 1 DIMM memory slot> – 2 GB per controller> – 1 GB per controller
• Two 4 Gb/s FC external drive interfaces per controller
Sun Confidential: Internal Only
RAID Controller - Sun StorageTek 6140 Array with 4 GB Cache, 8 Host Ports
LSI 3994 Controller
Sun Confidential: Internal Only
RAID Controller - Sun StorageTek 6140 Array with 2 GB Cache, 4 Host Ports
LSI 3992 Controller
Sun Confidential: Internal Only
Controller Hardware Features• Dual controller architecture/• 667 MHz Lindsay XScale IOP80331
> DDR-I 333 MHz DIMM up to 2GB.> PCI-X 133/100 MHz, I2C selectable upon reset (sub-model defined).> UART> 2x I2C Cores
• Up to 4 FC Host Ports, 2/4 Gbps (auto-negotiated) using Agilent DX4+
• Switched Architecture Disk Connections using Vixel SOC422• Dual Disk Expansion Ports• Dual 10/100BASE-T Ethernet Ports/w EEPROM (91C111)• Optional Battery Backup with removable CRU• 128 kB NVSRAM, Dallas DS1556
Sun Confidential: Internal Only
Software Architecture
Customer Management Station
Web ServerApache / Tomcat
Management UI & Logic
Element Manager
Storage Software Manager
DiagnosticsUI & LogicStorADE
CIMOM
ArrayProvider
Customer DataHost
RemoteCLI
Fibre ChannelDriver
Multi-pathingDriverMPXIO
CSM2RAID
Controller
Customer Browser
Fibre Channel Data Network
Ethernet Management Network
BOL
Array API
SMI/S Mgmt S/w
Telemetryto Sun
DiagnosticsUI & LogicStorADE
> Same architecture as 6130❏ Supports 6130 and 6140❏ Customers can upgrade a 6130
management station and it will support both products
> Software Components❏ Sun StorageTek Common Array
Manager (CAM)❏ Diagnostics - StorADE 2.4❏ SSCS – command line interface
(CLI)❏ Storage Software Manager❏ CSM-2 Firmware
> SANtricity Option
Sun Confidential: Internal Only
Array Management Software● Sun StorageTek Common Array Manager (CBEM)– Can manage 6130 and 6140 from one instance– Support for Remote Replication – Support for Vdisk / Drive Revive – Navigational Tree added for ease of use– Volume Mapping Summary – Activity Log
• SANtricity - Optional
Sun Confidential: Internal Only
Management Host Compatibility• Sun StorageTek Common Array Manager (CAM)
> Solaris SPARC> 8 Update 4> 9> 10
> Solaris x86, Windows> Linux – both Suse and RedHat coming soon....
• SANtricity> Solaris, Windows, Linux, AIX, HP-UX
Sun Confidential: Internal Only
Storage Software Manager● Replaces Software Lifecycle Manager from SE6130● InstallShield based installer● Available with both Command Line and Graphical
User Interfaces● Installs and/or Upgrades – Data Host/Management Host Software– Array Controller F/W– Array Expansion Tray Firmware– Disk Drive Firmware
Sun Confidential: Internal Only
Serial Port Service Interface• Mini-DIN connector
> Mini-DIN to 9 pin D serial convertor included• Uses
> Set TCP/IP network parameters> If DHCP and static IP configuration are not appropriate
> Display network parameters> Reset array password
Sun Confidential: Internal Only
Service Interface ExampleSend <BREAK> for Service Interface or baud rate changePress within 5 seconds: <S> for Service Interface, <BREAK> for baud rate Current date: 01/27/06 time: 18:43:01Enter Password to access Service Interface (60 sec timeout): Service Interface Main Menu============================== 1) Display IP Configuration 2) Change IP Configuration 3) Reset Storage Array (SYMbol) Password Q) Quit Menu Enter Selection:
Sun Confidential: Internal Only
Interop• Interop matrix is based upon Sun internal plus OEM
(Engenio) testing results.> Solaris/SPARC – versions: Solaris 8 Update 4, Solaris 9, Solaris 10. Failover
driver MPxIO> Solaris x64 – versions: Solaris 10 update 1. Fail-over drive MPxIO.> Microsoft Windows – 2000, 2003> IBM AIX > HP HPUX > Red Hat Linux RHEL – > (Novell) SuSE Linux SLES > Novell Netware > SGI IRIX
Sun Confidential: Internal Only
Sun StorageTek 6140 Array Data Services● Data Services are premium features. Licensing key
for purchase.● Hard Licensing is used. Licenses are keyed to the
array serial number.● Snapshot● Volume Copy● Remote Replication ● Storage Domains (0 default, 4,8,16, 64 optional)
Sun Confidential: Internal Only
StorageTek Data Replicator• Storage-based solution• Fibre-channel• Consumes one FC port per controller• Synchronous & asynchronous write mode
– Asynchronous write-order consistency– Dynamic write mode switching
• Adjustable replication I/O priority• Fully integrated with StorageTek Common Array
Manager– Wizard based setup
• DRM will be supported using SMIS 1.1 provider
Sun Confidential: Internal Only
StorageTek Data Snapshot• Allows creation of a virtual “Point In Time” (PIT) copy of a
volume in the storage array> Fairly instantaneous> Requires less space than a full copy> Mappable to any host> Can be read from and written to> Copied volume termed the “base” volume> Data required to preserve the snapshot contained in
“reserve” volume
Sun Confidential: Internal Only
Snapshot Reserve Volume• Holds data overwritten in base, or data written to snapshot
volume> Data preserved from base termed COW (copy-on-first-
write) data.• Can reside in different virtual disk from base volume• User defined capacity – defaults to 20% of base• Expandable via DVE• One reserve per snapshot (no shared copy-on-write data)
Sun Confidential: Internal Only
Data Snapshot Limits• Upto 4 snapshots of a given volume• Max 512 snapshots per StorageTek 6140 array• Base volume, reserve volume and snapshot are all
owned by the same controller
Sun Confidential: Internal Only
StorageTek Data Volume Copy• Allows creation of a complete byte-for-byte copy of a
volume within the storage array> Copied volume termed “source” volume> Copy of volume termed “target” or “clone” volume
• “Copy Request” Object> Associates source and target volumes (copy pair)> May be created, started, stopped and deleted
Sun Confidential: Internal Only
Volume Copy – Source Volume• May be a standard volume, snapshot or replication primary
volume• Source volume is read-only during copy process
> While volume copy has status of In Progress, Pending or Failed
> Maintains PiT integrity> Volcopy a snapshot to maintain normal I/O to source
volume during copy• If you need to continue to write to the source
volume, create a snapshot, then create volume copy of the snapshot
Sun Confidential: Internal Only
StorageTek Volume Copy – Target Volume• Selection
> May be a standard volume, base volume of a disabled or failed snapshot, replication primary
> May reside in a different vdisk to the source volume> Must be at least the same capacity as the source volume
• Identical to the source volume after the copy completes
• As long as copy relationship is maintained> Target copy can be set to read-only> “Re-copy” command uses same source/target
Sun Confidential: Internal Only
Remote Volume Replication• Storage-based solution• Fibre-channel• Consumes one FC port per controller• Synchronous & asynchronous write mode
– Asynchronous write order consistency– Dynamic write mode switching
• Adjustable replication I/O priority• Fully integrated with StorEdge Configuration Service
– Wizard based setup• DRM will be supported using SMIS 1.1 provider
Sun Confidential: Internal Only
Replication Rules● Mirroring relationship is on a volume basis● At most one replication relationship per volume
● Primary and secondary volumes must be standard volumes
● An array may have up to 32 replication relationships (primary or secondary)
● A minimum of 2 arrays are required● Both primary and secondary volumes must be
owned by the same controller in each storage array● Secondary volumes are read-only
Sun Confidential: Internal Only
StorageTek 6140 Array - Technical Summary– New 4 gigabits-per-second
improves time to data access and is backward and forward compatible
– Same high-availability hardware as in previous generations
– Same open SMI/S management software as in previous generations
– Same enterprise-level replication, snapshot, and volume copy
– Common management software across the StrorageTek 6000 family
– Data-in-place upgradeability preserves investment
Sun StorageTek 6140 ArrayTechnical Presentation