Roller Type K90 S Type K90 ZIP Type K130 S Type K130 ZIP
DIMENSIONS S80 Z90 LUX Mirror
Max. width (mm) 4000 4000 2800 2500
Min. width (mm) 600 600 600 600
Max. hight (mm) 3500 3500 3500 3500
Min. hight (mm) 400 400 400 400
Max. width (mm) 4000 4000 5700 3000 3000 5700 5700
Min. width (mm) 700 700 700 700 700 700 700
Max. hight (mm) 2800 2800 2800 3000 3000 3000 3000
Min. hight (mm) 1000 1000 1000 1000 1000 1000 1000
Max square (m2) 9 9 12 6 6 12 14
DIMENSIONS Type VR Type VS Type V ZIP Type K 90 S Type K 90 ZIP Type K 130 S Type K 130 ZIP
SU
N S
HA
DIN
G S
YS
TE
MS
46
SU
N S
HA
DIN
G S
YS
TE
MS
47
Screen types
ControlZIP Roller can be controlled manually or by using an electric switch or remote control.
ScreenThe ‘Screen’ canvas provides effective protection against overheating and fixed transparency, provided we keep the roller in open position.
BlackoutIn case we want total blackout in the room,an external dimmer screen can be used.The fastening of the canvas to the guidesensures complete blackout.
ZIP Rollers can also be used as interiordimming shades.
Solar Energy
RS = 35 %Solar Reflection
AS = 62 %Solar Absorption
gtote = 0.05
External Solar Factor
TV = 3 %Visible Light Transmission
TS = 3 %Solar Transmission
Given values for colour shade 92-2045 (according to EN14501 with type “C” double glazing insulating materials)
AR + RS = 100 %of incident solar energy
Solar Energy
RSSolar Reflection
ASSolar Absorption Window
Darkened interior
Prod
uct c
atal
ogue
/ R
olle
r sys
tem
s
SU
N S
HA
DIN
G S
YS
TE
MS
48Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Roller Type
110 mm
30 mm
W
H
114
mm
Section view Front view Isometric view
∅ 20 mm
V RPr
oduc
t cat
alog
ue /
Rol
ler s
yste
ms
SU
N S
HA
DIN
G S
YS
TE
MS
49
Front viewScale: 1:5
Section view A-AScale: 1:5 Isometric view
Scale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5 Isometric view
Scale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5 Isometric view
Scale: 1:5
Roller Type
123 mm24 mm 14 mm
30 mm 18 mm 18 mm
W
H
121 m
m
Section view Front view Isometric view
∅ 20 mm
V S
Prod
uct c
atal
ogue
/ R
olle
r sys
tem
s
SU
N S
HA
DIN
G S
YS
TE
MS
50
Prod
uct c
atal
ogue
/ Z
IP R
olle
r sys
tem
s
SU
N S
HA
DIN
G S
YS
TE
MS
51
Roller Type
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
123 mm
45 mm45 mm
24 mm 14 mm
34 mm 45 mm 45 mm
W
H
121 m
m
Section view
Guide rails
Front view Isometric view
36 m
m
Front viewScale: 1:1
Zip klasik vodilo
Front viewScale: 1:1
Zip vgradno vodilo
35 m
m
39 m
m
FRONT BUILT-IN
V ZIP
Prod
uct c
atal
ogue
/ R
olle
r sys
tem
s
SU
N S
HA
DIN
G S
YS
TE
MS
52
Front viewScale: 1:5
Section view A-AScale: 1:5 Isometric view
Scale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5 Isometric view
Scale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5 Isometric view
Scale: 1:5
Roller Type
91 mm
30 mm 18 mm 18 mm
W
H
89 m
m
Section view Front view Isometric view
∅ 20 mm
K 90 SPr
oduc
t cat
alog
ue /
Rol
ler s
yste
ms
SU
N S
HA
DIN
G S
YS
TE
MS
53
Front viewScale: 1:5Section view A-A
Scale: 1:5
Isometric viewScale: 1:5Front view
Scale: 1:5Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5Section view A-A
Scale: 1:5
Isometric viewScale: 1:5
Roller Type
91 mm
34 mm
W
H
89 m
m
Section view Front view Isometric view
36 m
m
45 mm 45 mm
K 90 ZIP
Prod
uct c
atal
ogue
/ R
olle
r sys
tem
s
45 mm45 mm
Guide rails
Front viewScale: 1:1
Zip klasik vodilo
Front viewScale: 1:1
Zip vgradno vodilo
35 m
m
39 m
m
FRONT BUILT-IN
SU
N S
HA
DIN
G S
YS
TE
MS
54
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Roller Type
120 mm
30 mm 18 mm 18 mm
W
H
130
mm
Section view Front view Isometric view
∅ 20 mm
K 130 SPr
oduc
t cat
alog
ue /
Rol
ler s
yste
ms
SU
N S
HA
DIN
G S
YS
TE
MS
55
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5
Front viewScale: 1:5
Section view A-AScale: 1:5
Isometric viewScale: 1:5Front view
Scale: 1:5Section view A-AScale: 1:5
Isometric viewScale: 1:5
Roller Type
120 mm
45 mm 45 mm
W
H
130
mm
Section view Front view Isometric view
34 mm
36 m
m
K 130 ZIP
Prod
uct c
atal
ogue
/ R
olle
r sys
tem
s
45 mm45 mm
Guide rails
Front viewScale: 1:1
Zip klasik vodilo
Front viewScale: 1:1
Zip vgradno vodilo
35 m
m
39 m
m
FRONT BUILT-IN
SU
N S
HA
DIN
G S
YS
TE
MS
56
Adjustments to your needsSome types of our blinds ensure total blackout, protection from burglary and stability in windy conditions.
Regulation of daylightThe use of blinds ensures indirect and diffused light in the interior. By rotating the slats, we can efficiently regulate daylight and transparency in the room.
Advantages
SU
N S
HA
DIN
G S
YS
TE
MS
Prod
uct c
atal
ogue
/ B
linds
56
Integration into the façadeVenetian blinds can be integrated into the façade. In this way thermal bridges are avoided.
Wide selection of coloursA variety of colours and slat shapes is available. All slat guide rails can be colourcoordinated to your requirements to any RAL chart shade.
Integrated mosquito netIt is possible to integrate a mosquito net into the system of external venetian blinds.
Manual or motor driveBlinds can be controlled manually (by means of a crank) or motor controlled.
Installation using cover panelsExternal venetian blinds can be mounted on external visible or subfaçade cover panels made from aluminium or galvanized steel.
Protection from adverse weather conditionsVenetian blinds offer great balance between protection from overheating and preventing thermal solar energy from entering the interior.