suction filters - hydroma · 2018. 7. 10. · nbr nbr fkm fkm 33 p1--pressure gauge pressure switch...

6

Upload: others

Post on 24-Jan-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Suction Filters - Hydroma · 2018. 7. 10. · NBR NBR FKM FKM 33 P1--Pressure gauge Pressure switch ATEX 3 GD EEx e T6 9 77 1/8” 24 Setting 20 kPa (0,2 bar) SUCTION LINE 9 77 1/8”
Page 2: Suction Filters - Hydroma · 2018. 7. 10. · NBR NBR FKM FKM 33 P1--Pressure gauge Pressure switch ATEX 3 GD EEx e T6 9 77 1/8” 24 Setting 20 kPa (0,2 bar) SUCTION LINE 9 77 1/8”

Port sizes: 3/8” ÷ 1” 1/2Flow rates: 4 ÷ 600 l/min

TECHNICAL DATAMax. working pressure: 700 kPa (7bar)Max. test pressure: 1,4 MPa (14 bar)Bursting pressure: 2,1 MPa (21 bar)

Filter element collapse pressure: ∆p 400 kPa (4 bar) - ISO 4572

Working temperature: -25 ÷ +110°C

MATERIALSHead: aluminiumBowl: cold formed steelSeals: standard NBR on request FKM

COMPATIBILITY (ISO 2943:1999)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales Department.

All tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test. For further information contact our Technical Dept.

LFM1 MPa (10 bar)Su

ctio

n Fi

lters

LFM

Page 3: Suction Filters - Hydroma · 2018. 7. 10. · NBR NBR FKM FKM 33 P1--Pressure gauge Pressure switch ATEX 3 GD EEx e T6 9 77 1/8” 24 Setting 20 kPa (0,2 bar) SUCTION LINE 9 77 1/8”

LFM

010 050 070 120

CLE

180

RDMVCDCVMSMN

RD = 10µMV = 25µCD = 10µCV = 25µMS = 60µMN = 125µ

RD = 10µRV = 25µCD = 10µCV = 25µMS = 60µMN = 125µ

RDMVCDCVMSMN

RDMVCDCVMSMN

RDMVCDCVMSMN

RDMVCDCVMSMN

00 = Without 0 0 0

0

0

12

1 = NBR Nitrile2 = FKM Fluoroelastomer

1 = NBR Nitrile2 = FKM Fluoroelastomer

12

12

12

12

B = BSPN = NPT

BN

BN

BN

BN

BN

23----

2 = 3/8”3 = 1/2”4 = 3/4”5 = 1”6 = 1” 1/47 = 1” 1/2

--4---

----6-

-----7

---5--

0E = nr. 2 ports 1/8”, plugged33 = Pressure gaugeP1 = Pressure switch11 = Vacuum gauge91 = Vacuum switch

0E33P111 91

0E33P111 91

0E33P111 91

0E33P111 91

0E33P111 91

XX XXXX = No accessory available

XX

XX XX XX

Stainless steel wire mesh

Steel wire mesh

Paper

Stainless steel wire mesh

Steel wire mesh

Paper

Type Type

Filter media Filter media

Bypass type

Ports

Port size

Seals

Indicators

Seals

Accessories

Return line

Suction line

HOW TO ORDER THE COMPLETE FILTER HOW TO ORDER THE FILTER ELEMENT

Suct

ion

Filte

rsLF

M

Page 4: Suction Filters - Hydroma · 2018. 7. 10. · NBR NBR FKM FKM 33 P1--Pressure gauge Pressure switch ATEX 3 GD EEx e T6 9 77 1/8” 24 Setting 20 kPa (0,2 bar) SUCTION LINE 9 77 1/8”

Indicator Port Indicator Port

L2

L3

L1

D3

D2

H5

D1

H2

H3

H4

R

H1

(return low pressure) (suction)

Type

LFM 010.2

LFM 010.3

LFM 050

LFM 070

LFM 120

LFM 180

3/8”

1/2”

3/4”

1”

1” 1/4

1” 1/2

170

170

245

285

290

345

22

22

37

37

40

40

38

38

39

39

50

50

95

95

135

135

185

185

50

50

100

100

150

150

6,5

6,5

8,5

8,5

10,5

10,5

81

81

114

114

155

155

105

105

140

140

178

178

132

132

206

246

240

295

26

26

24

24

28

28

20

20

25

25

25

25

1,0

1,0

2,0

2,5

6,0

6,5

D1 H1 H2 H3 L1 D2 D3H4 L2 H5 R WeightKgL3

DIMENSIONAL LAYOUT(mm)

Suct

ion

Filte

rsLF

M

Page 5: Suction Filters - Hydroma · 2018. 7. 10. · NBR NBR FKM FKM 33 P1--Pressure gauge Pressure switch ATEX 3 GD EEx e T6 9 77 1/8” 24 Setting 20 kPa (0,2 bar) SUCTION LINE 9 77 1/8”

CLOGGING INDICATORS

Scale 0 ÷ 1,2 MPa (12 bar)

Setting 150 kPa (1,5 bar)

RETURN LINE

NBR

NBR

FKM

FKM

33

P1

-

-

Pressure gauge

Pressure switchATEX 3 GD EEx e T6

977

1/8”

24

Setting 20 kPa (0,2 bar)

SUCTION LINE9

77

1/8”

24

NBR

NBR

FKM

FKM

11

91

-

-

Vacuum gauge

Pressure switchATEX 3 GD EEx e T6

1

3 2

SPDT, C.C. 30V: > max resistive or inductive load 3A - 1A respectivelyC.A. 125 or 250V: > max resistive or inductive load 3A - 0,5A respectivelyProtection IP65 - Connector DIN 43650

SPDT, C.C. 30V: > max resistive or inductive load 3A - 1A respectivelyC.A. 125 or 250V: > max resistive or inductive load 3A - 0,5A respectivelyProtection IP65 - Connector DIN 43650

Scale 0 ÷ 100 kPa (1 bar)

ø 40

1/8”

25

11

1

23

ø 40 25

1/8”

11

Suct

ion

Filte

rsLF

M

Page 6: Suction Filters - Hydroma · 2018. 7. 10. · NBR NBR FKM FKM 33 P1--Pressure gauge Pressure switch ATEX 3 GD EEx e T6 9 77 1/8” 24 Setting 20 kPa (0,2 bar) SUCTION LINE 9 77 1/8”