substation power transformers pad mounted transformers tr_1408.pdf · substation power transformers...
TRANSCRIPT
www.lsis.com
ANSI, IEEE and NEMA
Substation Power Transformers
Pad Mounted Transformers
2 I
Substation Power Transformers
We are able to achieve compact design with 3D Modeling and high efficiency Substation Power Transformers with Hib grade silicon steel and special type design that is to be easy transpotation and installation.
General explanation
Max. Voltage and MVA : Upto 138 kV and 50 MVATap changer type : Off load and Load tap changersAvailable Fluids : Mineral Oil, Silicon Oil and FR3(Vegetable Oil)Standard : ANSI, IEEE, NEMA and IEC
Product Scope
High efficiency design - TP1Special Ambient DesignLow Sound Level Design50 Hz and 60 Hz DesignK-Factor RatingNetwork type Transformers
Applications
LS Cast Resin Transformers
I 3
LSIS three-phase pad-mounted transformer is designed to protect environmental hazards.
All transformers are developed and produced especially to satisfy exacting customer’s exact specification.
The latest applicable standards (ANSI, NEMA, IEEE) have been applied to all of LSIS transformers.
Three-phase pad-mounted transformers are available in live-front or dead-front designs.
Both radial and loop feed configurations are built based on ANSI standards.
The dead-front bushing configurations are in accordance with ANSI C57.12.26, livefront per ANSI C57.12.22.
This establish to underground supply of electric power system burying processing distribution line in land as suitable transformer at beauty of city environment.
The quality of corrugated style radiator is superior to panel style radiator which is mainly used in existing.
LSIS manufacture to have excellent cooling effect by corrugate cooling way and external appearance is beautiful.
LSIS proven design offers excellent mechanical strength that has been proven through years of service and special testing.
We are constantly trying our best to introduce innovative product to the transformer industry, bringing you the high quality transformer with competitive cost.
General explanation
4 I
●65 average winding rise●Unique step-stacked core and rectangular wound core●60Hz standard, optional 50Hz●Mineral oil, optional FR3●Operating Voltages for 300kVA through 1500kVA rating:
High Voltages(HV):- 4160Grd Y/2400 V through 34500 Grd Y/19920 V- 2400 through 34500 V Delta- Various Dual high voltages
High Voltage taps:- All Voltages are available with 5 or 7 step taps- Dual Voltage taps provided only on the higher voltage
Low Voltage (LV):- 208Y/120 V, 480Y/277 V, 480 V , 240V , and 240 V , with 120 V mid-tap in one phase- 4160Y/2400 V, 4160 V , 2400 V ,
Primary insulation classes : 35 kV, 200 kV BIL and below
●Operating voltages for 2000kVA through 7500kVA rating:High Voltages(HV):- 12470Grd Y/7200 V through 34500 Grd Y/19920 V- 4160 V through 34500 V Delta- Various dual high voltagesVoltage taps:- All voltages are available with 5 or 7 step taps- Dual voltage taps provided only on the higher voltageLow Voltages (LV):- 480Y/277V, 480V , 240V- 4160Y/2400V, 4160V , 2400V
●Impedance guidelines:300kVA-500kVA : 2.8-5.0% nominal750kVA-2500kVA : 5.75% nominal3000kVA-7500kVA : consult LSIS Transformers.
Pad Mounted Transformers
Standard characteristics
LS Cast Resin Transformers
I 5
DOOR
2 HOLE HORIZ NEMA GRD PAD
LV BUSHING
HV BUSHING
TAP CHANGER
DIALTYPE THERMOMETER
OIL FILL PLOG
PRESS RELIEF VALVE
PRESS Vacuum
LIQUID LEVEL GAUGE
●Tank : Mild steel, optional stainless steel● Bolted-on cabinet with removable sill having the following
depths :- 19" deep for 300kVA through 750 kVA- 22" deep for 1000kVA through 1500kVA- 24" deep for 2000 kVA through 3750kVA- 30" deep for 5000 Kva through 7500kVA
● HV and LV compartment doors-hinged and lift-off type with 120˚ holding bars
●Stainless steel door hinges●Steel HV/LV compartment barrier● Padlocking facikity with one penta-head bolt on the LV
compartment door and two penta-head bolts on the HV compartment door-including 3 point latching mechanism
●HV connection:- Live front-external clamoed and removable HV bushings with eyebolt, clamp type connector
●LV connection:- Externally clamped polymer & porcelain LV bushing with 4-12 Hole spades
●Nameplate per ANSI requirement●Self-actuating pressure relief valve●Oil fill plug●1" drain valve eith sampler for 750 kVA and above●Removable LV neutral ground strap; as required●Xo/Ho for Y-Y connected transformers●Cooling panels● Durable, corrosion-resistance powder coat paint finished
Munsell Green 7GY3.29/1.5 or ANSI#70 Gray 5.0BG7.0/0.4●NEMA tank ground pads●Four(4) lifting lugs●Jacking bosses●Provision for liquid level gauge●Provision for liquid temperature gauge●Provision for pressure vacuum gauge●Provision for press relief valve
Standard features
6 I
Phase Pad Mounted TransformerLiquid Filled Three
Dead FrontRadial Feed
NO. NAME NO. NAME1 HV BUSHING 12 I IN DRAIN VALVE WITH SAMPLER2 BAY-O-NET FUSE 13 PAD LOCKABLE DOOR HANDLE3 TAP CHANGER 14 LIFTING LUGS4 DIAL TYPE THERMOMETER 15 HAND HOLE & SECURITY COVER5 I IN FILL PLUG 16 TANK6 PRESSURE VACUUM GAUGE 17 COOLING RADIATORS7 LIQUID LEVEL GAUGE 18 JACKING PAD8 PRESSURE RELIEF VALVE 19 JACKING PROVISIONS9 LV BUSHING 20 DOOR10 NAME PLATE 21 2 HOLE HORIZ NEMA GRD PAD11 SERIAL NO 22 METAL LV-HV BARRIER
H.V 12470V, 13200V, 13800, 24940VL.V 480Y/277V, 208Y/120V
RATINGkVA
A B C D EOIL
VOLUMEGallons
TOTALWEIGHT
Lbs.
500 54 55 62 37 37 180 4600750 57 62 65 40 40 230 58501000 57 75 69 43 43 280 68001500 60 84 70 44 44 360 94002000 63 86 71 46 46 400 111002500 64 90 74 47 47 460 130003000 70 108 80 49 49 480 141003750 73 127 81 51 51 520 15700
UNIT : INCH
Live FrontRadial Feed
Dead & Live Front - Radial Feed
A
D
X0
X1
X2
X3
H1A H2A H3A
X0
X1
X2
X3
5.5 5.5
8E
8EE
4.0~6.0
B
C
13
14 15
18
19
1
21 22 12
20
21 22 12
20
2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11
16 17
LS Cast Resin Transformers
I 7
NO. NAME NO. NAME1 HV BUSHING WEKKS ONLY 13 PAD LOCKABLE DOOR HANDLE2 BAY-O-NET FUSE 14 LIFTING LUGS3 4-POSITION T-BLADE S/W 15 HAND HOLE & SECURITY COVER4 DIAL TYPE THERMOMETER 16 TANK5 I IN FILL PLUG 17 COOLING RADIATORS6 PRESSURE VACUUM GAUGE 18 JACKING PAD7 LIQUID LEVEL GAUGE 19 JACKING PROVISIONS8 PRESSURE RELIEF VALVE 20 DOOR9 LV BUSHING 21 METAL LV-HV BARRIER10 NAME PLATE 22 2 HOLE HORIZ NEMA GRD PAD11 SERIAL NO 23 TAP CHANGER12 I IN DRAIN VALVE WITH SAMPLER
H.V 12470V, 13200V, 13800V, 24940VL.V 480Y/277V, 208Y/120V
RATINGkVA
A B C D EOIL
VOLUMEGallons
TOTALWEIGHT
Lbs.
500 56 55 64 36 37 210 4900750 59 62 67 39 40 250 60001000 60 75 71 42 43 310 70101500 62 84 72 43 44 390 98502000 64 86 73 45 46 430 112002500 66 90 76 46 47 490 132003000 72 108 82 48 49 510 144003750 75 127 83 50 51 550 16000
UNIT : INCH
Dead Front - Loop Feed
H1A
H2A H2B
H3A
3.0~4.0 4.0~6.0
H3B
H1B X0
X1
X3
X2
5.5
E
A
D E
C
8
55
21 22 12 12
18
20
13
14 15 16 171 2 3 4
2322
5 6 7 8 9 10 11
www.lsis.comⓒ 2014.08 LSIS Co.,Ltd. All rights reserved.
Specifications in this catalog are subject to change without notice due to continuous product development and improvement.
▒ HEAD OFFICELS-ro 127 (Hogye-dong) Dongan-gu Anyang-si Gyeonggi-do Korea Tel. (82-2)2034-4840, 4911, 4914Fax. (82-2)2034-4648
▒ CHEONG-JU PLANTCheong-Ju Plant #1, 95 Baekbong-ro Heungdeok-gu Cheongju-si Chungcheongbuk-do 361-720 Korea
2014. 08 Pad Mounted Transformers(E) 2014. 08/(1) 2014. 08 Printed in Korea STAFF
•LSIS USA Inc. ≫ Chicago, AmericaAddress: 2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of AmericaTel: 847-941-8240 Fax: 847-941-8259 e-mail: [email protected]
•LSIS (Middle East) FZE ≫ Dubai, U.A.E.Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab EmiratesTel: 971 4 886 5360 Fax: 971 4 886 5361 e mail: hschoib@lsis com
•LSIS Europe B.V. ≫ Schiphol-Rijk, NetherlandsAddress: 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The NetherlandsTel: 31-20-654-1420 Fax: 31-20-654-1429 e-mail: [email protected]
•LSIS-VINA Co., Ltd. ≫ Hanoi, VietnamAddress: Nguyen Khe - Dong Anh - Ha Noi - Viet NamTel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: [email protected]
•LSIS-VINA Co., Ltd. ≫ Hochiminh, VietnamAddress: 41 Nguyen Thi Minh Khai Str. Yoco Bldg 4th Floor, Hochiminh City, VietnamTel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: [email protected]
•LSIS Gurgaon Office ≫ Gurgaon, IndiaAddress: 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, IndiaTel: +0091-124-493-0070 Fax: 91-1244-930-066 e-mail: [email protected]
•LSIS Japan Co., Ltd. ≫ Tokyo, JapanAddress: Toykokurakubu Bldg. 13th floor, 3-2-6, Kasumigaseki, Chiyoda-ku, Tokyo, 100-0013 JapanTEL:+81-3-6268-8241 FAX:+81-3-6268-8240 e-mail: [email protected]
•LSIS Shanghai Office ≫ Shanghai, ChinaAddress: Room 32 floors of the Great Wall Building, No. 3000 North Zhongshan Road, Putuo District, Shanghai, ChinaTel: 86-21-5237-9977 Fax: 89-21-5237-7189 e-mail: [email protected]
•LSIS Beijing Office ≫ Beijing, ChinaAddress: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District, Beijing 100013, P.R. ChinaTel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: [email protected]
•LSIS Guangzhou Office ≫ Guangzhou, ChinaAddress: Room 1403, 14/F, New Poly Tower, No.2 Zhongshan Liu Road, Guangzhou 510180, P.R. ChinaTel: 020-8326-6754 Fax: 020-8326-6287 e-mail: [email protected]
•LSIS Chengdu Office ≫ Chengdu, ChinaAddress: Room 1701 17Floor, huamin hanjun internationnal Building, No1 Fuxing Road Chengdu, 610016, P.R. ChinaTel: 86-28-8670-3201 Fax: 86-28-8670-3203 e-mail: [email protected]
•LSIS Qingdao Office ≫ Qingdao, ChinaAddress: Room 2001,20/F,7B40, Galaxy Building, No.29 Shandong Road, Shinan District, Qingdao 266071, P.R. ChinaTel: 86-532-8501-6058 Fax: 86-532-8501-6057 e-mail: [email protected]
•LSIS (Wuxi) Co., Ltd. ≫ Wuxi, ChinaAddress: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.ChinaTel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: [email protected]
•Dalian LSIS Co., Ltd. ≫ Dalian, ChinaAddress: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, ChinaTel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: [email protected]
▒ Global Network
•For your safety, please read user's manual thoroughly before operating.
•Contact the nearest authorized service facility for examination, repair, or adjustment.
•�Please contact qualified service technician when you need maintenance. Do not disassemble or repair by yourself!
•Any maintenance and inspection shall be performed by the personnel having expertise concerned.Safety Instructions