ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. C HOT WATER COILS 266718 PROJECT: ENGINEER: CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: Submittal Sheet 06/25/2020 OF REV SHEET 1 2 © Copyright PRICE INDUSTRIES 2020 Solid Edge FDCLP2-1-1 1 ROW 2 ROW 1 ROW 2 ROW 1 ROW 2 ROW 1 ROW 2 ROW 10 12 8 ½ 21 8 ½ 10 305 203 13 22 533 203 13 22 20 12 10 ½ 21 10 ½ 20 305 254 13 22 533 254 13 22 30 12 10 ½ 21 10 ½ 30 305 254 13 22 533 254 13 22 UNIT SIZE STANDARD COILS HIGH CAPACITY COILS IMPERIAL UNITS (INCHES) B C CONNECTION SIZES B C CONNECTION SIZES HIGH CAPACITY COILS CONNECTION SIZES SI UNITS (mm) STANDARD COILS B C UNIT SIZE B C CONNECTION SIZES C 5" [127] B 1/2" [13] DIA @ 3" [76] 7/8" [22] DIA @ 4 1/4" [108] WATER CONNECTION SLIP & DRIVE CONNECTION IN OUT SEE NOTE #6 AIR FLOW CADQ - COIL ACCESS DOOR W/QUARTER TURN SASH LATCHES 4" [102] X 6 ¾" [171] CADL - ACCESS DOOR W/SNAP LATCHES 4" [102] x 6 ¾" [171] CAD - ACCESS DOOR W/SCREWS 4" [102] x 6 ¾" [171] ACCESS DOOR OPTIONS: HEATING COIL NOTES: 1. FABRICATED FROM 22 GA. GALVANIZED STEEL MECHANICALLY SEALED, LEAK RESISTANT CONSTRUCTION. 2. HOT WATER COILS HAVE COPPER TUBES AND ALUMINUM FINS WITH O.D. SWEAT CONNECTIONS. 3. REFER TO SUBMITTED SCHEDULE FOR AIR VOLUMES AND HOT WATER COIL CAPACITIES. 4. METHOD OF VENTING HOT WATER COIL IS TO BE PROVIDED BY INSTALLING CONTRACTOR. 5. HAND OF HOT WATER COIL CONNECTIONS IS DETERMINED WHEN VIEWED FROM AIR INLET SIDE. 6. ALLOW 1 1 / 2" (38) MINIMUM CLEARANCE FOR INSTALLATION AT THIS END. 7. WATER COILS ARE MOUNTED ON DISCHARGE OF UNIT. 8. PERFORMANCE RATED AND CERTIFIED IN ACCORDANCE WITH THE CURRENT EDITION OF AHRI STANDARD 410. 9. STANDARD COILS SUPPLIED WITH 10 FINS PER INCH, HC COILS - WITH 12 FINS PER INCH. OPTIONS: HC - HIGH CAPACITY WATER COIL DISCHARGE AIR PRIMARY AIR 1" (25) 6 1/2" (165) B SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY) OPTIONAL COIL ACCESS SECTION LOW PROFILE FAN POWERED TERMINAL CONSTANT VOLUME CONFIGURATION SIZES 10,20,30

Upload: others

Post on 26-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    C

    HOT WATER COILS

    266718

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 1 2© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    1 ROW 2 ROW 1 ROW 2 ROW 1 ROW 2 ROW 1 ROW 2 ROW

    10 12 8 ½ ⅞ 21 8 ½ ⅞ 10 305 203 13 22 533 203 13 22

    20 12 10 ½ ⅞ 21 10 ½ ⅞ 20 305 254 13 22 533 254 13 22

    30 12 10 ½ ⅞ 21 10 ½ ⅞ 30 305 254 13 22 533 254 13 22

    UNIT

    SIZE

    STANDARD COILS HIGH CAPACITY COILS

    IMPERIAL UNITS (INCHES)

    B CCONNECTION SIZES

    B CCONNECTION SIZES

    HIGH CAPACITY COILS

    CONNECTION SIZES

    SI UNITS (mm)

    STANDARD COILS

    B CUNIT SIZE

    B CCONNECTION SIZES

    C

    5" [127] B

    1/2" [13] DIA @ 3" [76]7/8" [22] DIA @ 4 1/4" [108]

    WATERCONNECTION

    SLIP & DRIVECONNECTION

    IN

    OUT

    SEE NOTE #6

    AIRFLOW

    CADQ - COIL ACCESS DOORW/QUARTER TURN SASH LATCHES4" [102] X 6 ¾" [171]

    CADL - ACCESS DOORW/SNAP LATCHES4" [102] x 6 ¾" [171]

    CAD - ACCESS DOOR W/SCREWS4" [102] x 6 ¾" [171]

    ACCESS DOOR OPTIONS:

    HE

    AT

    ING

    CO

    IL

    NOTES:1. FABRICATED FROM 22 GA. GALVANIZED STEEL MECHANICALLY SEALED, LEAK RESISTANT CONSTRUCTION.2. HOT WATER COILS HAVE COPPER TUBES AND ALUMINUM FINS WITH O.D. SWEAT CONNECTIONS.3. REFER TO SUBMITTED SCHEDULE FOR AIR VOLUMES AND HOT WATER COIL CAPACITIES.4. METHOD OF VENTING HOT WATER COIL IS TO BE PROVIDED BY INSTALLING CONTRACTOR.5. HAND OF HOT WATER COIL CONNECTIONS IS DETERMINED WHEN VIEWED FROM AIR INLET SIDE.

    6. ALLOW 1 1/2" (38) MINIMUM CLEARANCE FOR

    INSTALLATION AT THIS END.7. WATER COILS ARE MOUNTED ON DISCHARGE OF UNIT.8. PERFORMANCE RATED AND CERTIFIED IN ACCORDANCE WITH THE CURRENT EDITION OF AHRI STANDARD 410.9. STANDARD COILS SUPPLIED WITH 10 FINS PER INCH, HC COILS - WITH 12 FINS PER INCH.

    OPTIONS:�HC - HIGH CAPACITY WATER COIL

    DISCHARGE

    AIR

    PRIMARY

    AIR

    1" (25) 6 1/2" (165)

    B

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    OPTIONAL COIL ACCESS SECTION

    LOW PROFILEFAN POWERED TERMINAL

    CONSTANT VOLUMECONFIGURATION

    SIZES 10,20,30

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    C

    HOT WATER COILS

    266718

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 2 2© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    1 ROW 2 ROW 1 ROW 2 ROW 1 ROW 2 ROW 1 ROW 2 ROW

    50 21 10 ½ ⅞ 36 10 ⅞ ⅞ 50 533 254 13 22 914 254 22 22

    B CCONNECTION SIZES UNIT SIZE

    B C

    UNIT

    SIZE

    STANDARD COILS HIGH CAPACITY COILS

    IMPERIAL UNITS (INCHES)

    B CCONNECTION SIZES

    SI UNITS (mm)

    CONNECTION SIZESCONNECTION SIZES

    HIGH CAPACITY COILSSTANDARD COILS

    B C

    C

    5" [127] B

    1/2" [13] DIA @ 3" [76]7/8" [22] DIA @ 4 1/4" [108]

    WATERCONNECTION

    SLIP & DRIVECONNECTION

    IN

    OUT

    SEE NOTE #6

    AIRFLOW

    B

    HE

    AT

    ING

    CO

    IL

    CADQ - COIL ACCESS DOORW/QUARTER TURN SASH LATCHES4" [102] X 6 ¾" [171]

    CADL - ACCESS DOORW/SNAP LATCHES4" [102] x 6 ¾" [171]

    CAD - ACCESS DOOR W/SCREWS4" [102] x 6 ¾" [171]

    ACCESS DOOR OPTIONS:

    DISCHARGE

    AIR

    PRIMARY

    AIR

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    OPTIONAL COIL ACCESS SECTION

    1" (25) 6 1/2" (165)

    NOTES:1. FABRICATED FROM 22 GA. GALVANIZED STEEL MECHANICALLY SEALED, LEAK RESISTANT CONSTRUCTION.2. HOT WATER COILS HAVE COPPER TUBES AND ALUMINUM FINS WITH O.D. SWEAT CONNECTIONS.3. REFER TO SUBMITTED SCHEDULE FOR AIR VOLUMES AND HOT WATER COIL CAPACITIES.4. METHOD OF VENTING HOT WATER COIL IS TO BE PROVIDED BY INSTALLING CONTRACTOR.5. HAND OF HOT WATER COIL CONNECTIONS IS DETERMINED WHEN VIEWED FROM AIR INLET SIDE.

    6. ALLOW 1 1/2" (38) MINIMUM CLEARANCE FOR

    INSTALLATION AT THIS END.7. WATER COILS ARE MOUNTED ON DISCHARGE OF UNIT.8. PERFORMANCE RATED AND CERTIFIED IN ACCORDANCE WITH THE CURRENT EDITION OF AHRI STANDARD 410.9. STANDARD COILS SUPPLIED WITH 10 FINS PER INCH, HC COILS - WITH 12 FINS PER INCH.

    OPTIONS:�HC - HIGH CAPACITY WATER COIL

    LOW PROFILEFAN POWERED TERMINAL

    CONSTANT VOLUMECONFIGURATION

    SIZE 50

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    C

    ELECTRIC COILS

    CONSTANT VOLUMEFDCLP2266719

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 1 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    q 0 to 10 Vdc CONTROL SIGNALq 4 to 20 mA CONTROL SIGNALq 24 VAC PULSE CONTROL

    STANDARD FEATURES HINGED ACCESS DOOR AUTOMATIC RESET THERMAL CUTOUT MANUAL RESET THERMAL CUTOUT FAN INTERLOCKED WITH HEATING ELEMENTS MAGNETIC CONTACTORS 20 GA. GALVANIZED STEEL CONTRUCTION HIGH GRADE NICKEL CHROME HEATING ELEMENTS REFER TO SUBMITTED CONTROL DIAGRAMS FOR

    STANDARD CONTROL COMPONTS TO BE SUPPLIED SINGLE POINT ELECTRICAL CONNECTION, EXCEPT

    SEPARATE POWER SUPPY FOR 600/3O/3 WIRE SUPPLY VOLTAGE:q 115/1Oq 208/1O (3 WIRE)q 240/1Oq 277/1Oq 480/1O (3 WIRE)q 208/3O (4 WIRE)q 480/3O (4 WIRE)q 600/3O (3 OR 4 WIRE)

    ••••••••

    OPTIONAL FEATURES

    q AIR FLOW SWITCHq CHICAGO CONSTRUCTION (CBC2000)q CONTROL CIRCUIT FUSEq DOOR INTERLOCK DISCONNECT SWITCHq MAIN SUPPLY FUSEq MOTOR FUSEq MERCURY CONTACTORSq SCR CONTROLSq SCR-DAT CONTROLS

    q DP - DUAL POINT POWER CONNECTION

    NOTES 70 CFM PER KW MINIMUM AIR FLOW ACROSS HEATER COILS. MINIMUM 0.2" w.g.(50 Pa) EXTERNAL STATIC PRESSURE TO OPERATE.

    ••

    DISCHARGE

    AIR

    HINGED DOOR

    NEMA1 ELECTRIC COIL ENCLOSURE

    SLIP & DRIVE CONNECTION

    PRIMARY

    AIR

    OUTLET DUCT

    SIZE B x C

    10 12x8 (305x203) 8 1/2" (216) 19" (483)

    UNIT SIZE D E

    9 1/2" (241)

    6" (152)

    24" (610) SZ.10 DOOR SWING

    E

    C

    B

    D

    NEMA1 CONTROLS ENCLOSURE (OPTIONAL)

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    SIZES 10

    10 1/2" (267)

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    C

    ELECTRIC COILS

    CONSTANT VOLUMEFDCLP2266719

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 2 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    OUTLET DUCT

    SIZE B x C

    20

    30

    UNIT SIZE D E

    12x10 (305x254) 10 1/2" (267) 10 1/2" (267)

    STANDARD FEATURES HINGED ACCESS DOOR AUTOMATIC RESET THERMAL CUTOUT MANUAL RESET THERMAL CUTOUT FAN INTERLOCKED WITH HEATING ELEMENTS MAGNETIC CONTACTORS 20 GA. GALVANIZED STEEL CONTRUCTION HIGH GRADE NICKEL CHROME HEATING ELEMENTS REFER TO SUBMITTED CONTROL DIAGRAMS FOR

    STANDARD CONTROL COMPONTS TO BE SUPPLIED SINGLE POINT ELECTRICAL CONNECTION, EXCEPT

    SEPARATE POWER SUPPY FOR 600/3O/3 WIRE SUPPLY VOLTAGE:q 115/1Oq 208/1O (3 WIRE)q 240/1Oq 277/1Oq 480/1O (3 WIRE)q 208/3O (4 WIRE)q 480/3O (4 WIRE)q 600/3O (3 OR 4 WIRE)

    ••••••••

    OPTIONAL FEATURESq AIR FLOW SWITCHq CHICAGO CONSTRUCTION (CBC2000)q CONTROL CIRCUIT FUSEq DOOR INTERLOCK DISCONNECT SWITCHq MAIN SUPPLY FUSEq MOTOR FUSEq MERCURY CONTACTORSq SCR CONTROLSq SCR-DAT CONTROLSq DP - DUAL POINT POWER CONNECTION

    NOTES 70 CFM PER KW MINIMUM AIR FLOW ACROSS HEATER COILS. MINIMUM 0.2" w.g.(50 Pa) EXTERNAL STATIC PRESSURE TO OPERATE.

    ••

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    23 3/4" (603)

    E

    NEMA1 ELECTRICCOIL ENCLOSURE

    NEMA1 CONTROLSENCLOSURE (OPTIONAL)

    9 1/2" (241)

    DISCHARGE

    AIR

    B

    C D

    PRIMARY

    AIR

    SLIP & DRIVE CONNECTION

    SIZES 20&30

    20" DOOR SWING SZ.20,30

    6" (152)

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    C

    ELECTRIC COILS

    CONSTANT VOLUMEFDCLP2266719

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 3 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    OUTLET DUCT

    SIZE B x C

    50 21x10 (533x254) 10 1/2" (267) 11 1/2 (292)

    UNIT SIZE D E

    DISCHARGE

    AIR

    PRIMARY

    AIR

    NEMA1 CONTROLS ENCLOSURE (OPTIONAL)

    SLIP & DRIVE CONNECTION

    HINGED DOORNEMA1 ELECTRIC COIL ENCLOSURE

    C

    B

    D

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    q 0 to 10 Vdc CONTROL SIGNALq 4 to 20 mA CONTROL SIGNALq 24 VAC PULSE CONTROL

    STANDARD FEATURES HINGED ACCESS DOOR AUTOMATIC RESET THERMAL CUTOUT MANUAL RESET THERMAL CUTOUT FAN INTERLOCKED WITH HEATING ELEMENTS MAGNETIC CONTACTORS 20 GA. GALVANIZED STEEL CONTRUCTION HIGH GRADE NICKEL CHROME HEATING ELEMENTS REFER TO SUBMITTED CONTROL DIAGRAMS FOR

    STANDARD CONTROL COMPONTS TO BE SUPPLIED SINGLE POINT ELECTRICAL CONNECTION, EXCEPT

    SEPARATE POWER SUPPY FOR 600/3O/3 WIRE SUPPLY VOLTAGE:q 115/1Oq 208/1O (3 WIRE)q 240/1Oq 277/1Oq 480/1O (3 WIRE)q 208/3O (4 WIRE)q 480/3O (4 WIRE)q 600/3O (3 OR 4 WIRE)

    ••••••••

    OPTIONAL FEATURES

    q AIR FLOW SWITCHq CHICAGO CONSTRUCTION (CBC2000)q CONTROL CIRCUIT FUSEq DOOR INTERLOCK DISCONNECT SWITCHq MAIN SUPPLY FUSEq MOTOR FUSEq MERCURY CONTACTORSq SCR CONTROLSq SCR-DAT CONTROLS

    q DP - DUAL POINT POWER CONNECTION

    NOTES 70 CFM PER KW MINIMUM AIR FLOW ACROSS HEATER COILS. MINIMUM 0.2" w.g.(50 Pa) EXTERNAL STATIC PRESSURE TO OPERATE.

    ••

    SIZES 50 W/ ROUND INLET

    9 1/2" (241)

    1 1/3" (34)

    20" (508)DOOR SWING

    23 3/4" (603) E

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    C

    ELECTRIC COILS

    CONSTANT VOLUMEFDCLP2266719

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 4 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    OUTLET DUCT

    SIZE B x C

    50 21x10 (533x254) 10 1/2" (267) 11 1/2 (292)

    UNIT SIZE D E

    DISCHARGE

    AIR

    PRIMARY

    AIR

    C

    B

    D

    q 0 to 10 Vdc CONTROL SIGNALq 4 to 20 mA CONTROL SIGNALq 24 VAC PULSE CONTROL

    STANDARD FEATURES HINGED ACCESS DOOR AUTOMATIC RESET THERMAL CUTOUT MANUAL RESET THERMAL CUTOUT FAN INTERLOCKED WITH HEATING ELEMENTS MAGNETIC CONTACTORS 20 GA. GALVANIZED STEEL CONTRUCTION HIGH GRADE NICKEL CHROME HEATING ELEMENTS REFER TO SUBMITTED CONTROL DIAGRAMS FOR

    STANDARD CONTROL COMPONTS TO BE SUPPLIED SINGLE POINT ELECTRICAL CONNECTION, EXCEPT

    SEPARATE POWER SUPPY FOR 600/3O/3 WIRE SUPPLY VOLTAGE:q 115/1Oq 208/1O (3 WIRE)q 240/1Oq 277/1Oq 480/1O (3 WIRE)q 208/3O (4 WIRE)q 480/3O (4 WIRE)q 600/3O (3 OR 4 WIRE)

    ••••••••

    OPTIONAL FEATURES

    q AIR FLOW SWITCHq CHICAGO CONSTRUCTION (CBC2000)q CONTROL CIRCUIT FUSEq DOOR INTERLOCK DISCONNECT SWITCHq MAIN SUPPLY FUSEq MOTOR FUSEq MERCURY CONTACTORSq SCR CONTROLSq SCR-DAT CONTROLS

    q DP - DUAL POINT POWER CONNECTION

    NOTES 70 CFM PER KW MINIMUM AIR FLOW ACROSS HEATER COILS. MINIMUM 0.2" w.g.(50 Pa) EXTERNAL STATIC PRESSURE TO OPERATE.

    ••

    SIZES 50 W/14X8 INLET

    23 3/4" (603)

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    SLIP & DRIVE CONNECTION

    NEMA1 CONTROLS ENCLOSURE (OPTIONAL)

    NEMA1 ELECTRIC COIL ENCLOSURE

    6" (152)

    E

    23" (584)

    20" HINGED DOOR SWING

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    B

    ATTENUATOR

    DISCHARGEFDCLP2/FDCLP2-DOAS266720

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/30/2020

    OF REVSHEET 1 2© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    B C B C

    10 12 8 305 203

    20 12 10 305 254

    30 12 10 305 254

    NO COIL OR STANDARD REHEAT COIL

    UNIT

    SIZE

    IMPERIAL UNITS (INCHES) SI UNITS (mm)

    B C B C

    10 21 8 533 203

    20 21 10 553 254

    30 21 10 533 254

    SI UNITS (mm)UNIT

    SIZE

    IMPERIAL UNITS (INCHES)

    HIGH CAPACITY REHEAT COIL

    36" (914)OR 59" (1499)

    B

    C

    DISCHARGE

    AIR

    PRIMARY

    AIR

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    OPTIONAL COIL ACCESS SECTION

    HEATING COIL

    SIZES 10-30

    SIZES 10-30 W/ STANDARDREHEAT COIL

    NOTES: 22 GA. GALVANIZED STEEL HOUSING, MECHANICALLY SEALED LEAK RESISTANT CONSTRUCTION. INTERNAL INSULATION - 1/2" [13] THICK, MIN. 1.5# DENSITY WHICH MEETS REQUIREMENTS OF NFPA90A AND UL181. SLIP AND DRIVE CONNECTION ENDS AS SHOWN.ATTENUATORS SHIPPED LOOSE. SLIP AND DRIVE CLEATS PROVIDED WHERE REQUIRED.

    OPTIONS:� 3FT DISCHARGE ATTENUATOR SECTION (DAS3)� 5FT DISCHARGE ATTENUATOR SECTION (DAS5)

    ••••

    LINERS:� 1/2" FIBERFREE (FF50)� 5/8" FOIL FACED FIBERBOARD (FB)

    DISCHARGE ATTENUATOR

    DISCHARGE

    AIR

    PRIMARY

    AIR

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)SIZES 10-30 W/ NO COIL

    DISCHARGE ATTENUATOR

    1" (25)

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    B

    ATTENUATOR

    DISCHARGEFDCLP2/FDCLP2-DOAS266720

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/30/2020

    OF REVSHEET 2 2© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    NOTES: 22 GA. GALVANIZED STEEL HOUSING, MECHANICALLY SEALED LEAK RESISTANT CONSTRUCTION. INTERNAL INSULATION - 1/2" [13] THICK, MIN. 1.5# DENSITY WHICH MEETS REQUIREMENTS OF NFPA90A AND UL181. SLIP AND DRIVE CONNECTION ENDS AS SHOWN.ATTENUATORS SHIPPED LOOSE. SLIP AND DRIVE CLEATS PROVIDED WHERE REQUIRED.

    OPTIONS:� 3FT DISCHARGE ATTENUATOR SECTION (DAS3)� 5FT DISCHARGE ATTENUATOR SECTION (DAS5)

    ••••

    SIZES 50

    DISCHARGE

    AIR

    PRIMARY

    AIR

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    OPTIONAL COIL ACCESS SECTION

    SIZE 50/14x8 W/ STANDARDREHEAT COIL

    LINERS:� 1/2" FIBERFREE (FF50)� 5 / 8" FOIL FACED FIBERBOARD (FB)

    36" (914)OR 59" (1499)

    B

    C

    B C B C

    50 21 10 533 254

    NO COIL OR STANDARD REHEAT COIL

    UNIT

    SIZE

    IMPERIAL UNITS (INCHES) SI UNITS (mm)

    DISCHARGE

    AIR

    PRIMARY

    AIR

    SENSIBLE COOLING COIL (FDCLP2-DOAS ONLY)

    SIZE 50/14x8 W/ NO COIL

    HEATING COIL

    1" (25)

    DISCHARGE ATTENUATOR

    DISCHARGE ATTENUATOR

    B C B C

    50 36 10 914 254

    HIGH CAPACITY REHEAT COIL

    UNIT

    SIZE

    IMPERIAL UNITS (INCHES) SI UNITS (mm)

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    D

    FILTERS

    266722

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/30/2020

    OF REVSHEET 1 3© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FAN POWERED TERMINALSFDCLP2

    SIZES 10-50

    FDCLP2-1-1

    MERV 3

    NOTES:1. 1" [25] NOMINAL FILTER MEDIA2. CARDBOARD FRAME3. MERV3 RATING (THROWAWAY)

    W H W H

    10 16 8½ 406 216

    20,30 16 11 406 279

    50 26 11 660 279

    IMPERIAL UNITS (INCHES) S.I. UNITS (mm)UNIT

    SIZE

    W WMERV 3 FILTER MERV 3 FILTER

    SIZES 10,20,30,50 SIZE 50/14x8

    MERV 3 FILTERFILTERS CLIPPED TO HOSUING

    REINFORCED MEDIA SIDE W

    H

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    D

    FILTERS

    266722

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/30/2020

    OF REVSHEET 2 3© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FAN POWERED TERMINALSFDCLP2

    SIZES 10-50

    FDCLP2-1-1

    MERV 3, MERV 8, MERV 13

    MERV8/ MERV13 FILTER RACKFILTERS SLIDE INTO RAIL, RAILFASTENED TO COOLING COILHOUSING

    MERV 3 FILTERFILTERS SLIDE INTO RAIL, RAILFASTENED TO COOLING COILHOUSING

    NOTES:1. CARDBOARD FRAME2. 2 FILTERS PER UNIT REQUIRED

    OPTIONS:� 1" [25] NOMINAL FILTER MERV3 RATING [FTRM81]� 2" [51] NOMINAL FILTER MERV8 RATING [FTRM82]� 2" [51] NOMINAL FILTER MERV13 RATING [FTRM132]

    W H W H

    10 21 3/4 7 1/2 552 191

    20,30 18 1/4 10 464 254

    50 26 10 660 254

    IMPERIAL UNITS (INCHES) S.I. UNITS (mm)UNIT

    SIZE

    W

    H

    W

    H

    1" (25)

    2" (51)

    MERV FILTER 1" (25) FOR MERV3 FILTER2" (51) FOR MERV8/MERV 13 FILTERS

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    D

    FILTERS

    266722

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/30/2020

    OF REVSHEET 3 3© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FAN POWERED TERMINALSFDCLP2

    SIZES 10-50

    FDCLP2-1-1

    NOTES:1. 1" [25] NOMINAL FILTER MEDIA2. CARDBOARD FRAME3. MERV3 RATING (THROWAWAY)

    W H W H

    10 16 8½ 406 216

    20,30 12 11 305 279

    IMPERIAL UNITS (INCHES) S.I. UNITS (mm)UNIT

    SIZE

    W

    H

    MERV 3 FILTERFILTERS CLIPPED TO HOUSING

    MERV3 FILTER

    REINFORCED MEDIA SIDE W

    W/ IAS

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    O

    HBS

    HANGER BRACKETSPRING ISOLATION241538

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/24/2020

    OF REVSHEET 1 1© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    NOTES:1. HANGER BRACKETS AND SPRING LOADED BRACKETS ARE SHIPPED LOOSE FOR FIELDINSTALLATION BY OTHERS2. ORIENT THE ISOLATOR AS SHOWN TO PROPERLY DAMPEN TERMINAL3. RED SPRING LOAD RANGE: 16 LBS - 35 LBS4. YELLOW SPRING LOAD RANGE: 36 LBS - 65 LBS5. FOR FDCLP2 DOAS SIZE 50 8 ROW COIL USE YELLOW (X2)

    BASE UNIT DAS/SLR IAS/IAS90 EC/WCEC+SM/PM

    LINERRSLR

    DOAS SENSIBLE

    COOLING COIL

    FxV 20-30 RED (X4) RED (X2) RED (X2) - RED (X2) - -

    FxV 40-60 YELLOW (X4) RED (X2) RED (X2) - - - -

    FxVLP 20-40 RED (X4) RED (X2) RED (X2) - - - -

    FDCLP2 10 RED (X4) RED (X2) RED (X2) - - - -

    FDCLP2 20-30 RED (X4) RED (X2) RED (X2) RED (X2) - - -

    FDCLP2 50 YELLOW (X4) RED (X2) - YELLOW (X2) - - -

    FDCLP2 50 14x8 YELLOW (X6) RED (X2) - YELLOW (X2) - - -

    FDCLP2 DOAS 10 YELLOW (X4) RED (X2) - - - RED (X2) RED (X2)

    FDCLP2 DOAS 20,30,50 YELLOW (X4) RED (X2) - YELLOW (X2) - RED (X2) RED (X2) SEE NOTE 5

    FDCLP2 DOAS 50 14x8 YELLOW (X6) RED (X2) - YELLOW (X2) - RED (X2) RED (X2) SEE NOTE 5

    PRODUCT

    HBS QTY REQUIRED

    1.50 38MAX

    3.47 88MAX

    FASTEN HANGER BRACKETTO ISOLATOR

    HANGER BRACKET

    TERMINAL UNIT

    FROM CEILING SUPPORT SYSTEM

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    ACCESSORIES

    HANGER BRACKETS [HB]LOCATIONS

    FOR FDCLP2 / FDCLP2-DOAS266727

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 1 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    C FDCLP2-1-1

    NOTES: HANGER BRACKETS ARE 12 GAUGE ZINC COATED STEEL 4 PER FAN UNIT (6 FOR SIZE 50, 14x8), 2 PER DISCHARGE

    ATTENUATOR, 2 PER INLET ATTENUATOR BRACKETS ARE SHIPPED LOOSE FOR FIELD INSTALLATION FOR

    USE WITH THREADED HANGER RODS (BY OTHERS) LAYOUT INDICATES SUGGESTED HANGER BRACKET LOCATIONS

    ••

    3 3/16" [81]

    1" [25]

    O1/2" [13]

    3/4" [19]

    1 1/2" [38]2" [51]

    UNIT SIZE W L

    10 32 48

    20 26 41

    30 26 41

    50 44 54

    UNIT SIZE L W

    10 813 1219

    20 660 1041

    30 660 1041

    50 1118 1372

    IMPERIAL UNITS (INCHES) SI UNITS (mm)

    FDCLP2 SIZES 10-50 WITHOUT PROTECTIVESHROUD

    FDCLP2 SIZE 50 14X8 WITHPROTECTIVE SHROUD

    FDCLP2 SIZES 10-50 WITH PROTECTIVESHROUD

    FDCLP2 SIZE 50 14X8 WITHOUTPROTECTIVE SHROUD

    W

    1 25 TYP

    L

    1 25 TYP

    L W

    1 25 TYP

    W L W L

    1 25 TYP

    1 25 TYP1 25 TYP

    UNIT HANGER BRACKET3 3/16" [81]

    1" [25] 1/2" [13]1 1/2" [38]

    3/4" [19]

    O1/2" [13]

    SENSIBLE COOLING COIL HANGER BRACKET

    SENSIBLE COOLING COIL HANGERBRACKETS MOUNT FLUSHWITH FLANGE ON COIL INLETDO NOT SCREW THROUGH TUBES

    SENS

    IBLE C

    OOLIN

    G COIL

    (FDCL

    P2-D

    OAS O

    NLY)

    SENS

    IBLE C

    OOLIN

    G COIL

    (FDCL

    P2-D

    OAS O

    NLY)

    SENS

    IBLE C

    OOLIN

    G COIL

    (FDCL

    P2-D

    OAS O

    NLY)

    SENS

    IBLE C

    OOLIN

    G COIL

    (FDCL

    P2-D

    OAS O

    NLY)

    SENSIBLE COOLING COIL HANGERBRACKETS MOUNT FLUSHWITH FLANGE ON COIL INLETDO NOT SCREW THROUGH TUBES

    SENSIBLE COOLING COIL HANGERBRACKETS MOUNT FLUSHWITH FLANGE ON COIL INLETDO NOT SCREW THROUGH TUBES

    SENSIBLE COOLING COIL HANGERBRACKETS MOUNT FLUSHWITH FLANGE ON COIL INLETDO NOT SCREW THROUGH TUBES

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    ACCESSORIES

    HANGER BRACKETS [HB]LOCATIONS

    FOR FDCLP2 / FDCLP2-DOAS266727

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 2 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    C FDCLP2-1-1

    NOTES: HANGER BRACKETS ARE 12 GAUGE ZINC COATED STEEL 4 PER FAN UNIT (6 FOR SIZE 50, 14x8), 2 PER DISCHARGE

    ATTENUATOR, 2 PER INLET ATTENUATOR BRACKETS ARE SHIPPED LOOSE FOR FIELD INSTALLATION FOR

    USE WITH THREADED HANGER RODS (BY OTHERS) LAYOUT INDICATES SUGGESTED HANGER BRACKET LOCATIONS

    ••

    3 3/16" [81]

    1" [25]

    O1/2" [13]

    3/4" [19]

    1 1/2" [38]2" [51]

    UNIT SIZE W L

    10 32 48

    20 26 41

    30 26 41

    50 44 54

    UNIT SIZE L W

    10 813 1219

    20 660 1041

    30 660 1041

    50 1118 1372

    IMPERIAL UNITS (INCHES)

    SI UNITS (mm)

    FDCLP2 SIZE 10 WITH ELECTRICCOIL

    FDCLP2 SIZE 20, 30, & 50 WITHELECTRIC COIL

    L

    W

    1 25 TYP

    1 25 TYP

    1 25 TYP

    L

    W

    1 25 TYP

    1 25 TYP

    1 25 TYP

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    ACCESSORIES

    HANGER BRACKETS [HB]LOCATIONS

    FOR FDCLP2 / FDCLP2-DOAS266727

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 3 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    C FDCLP2-1-1

    3 3/16" [81]

    1" [25]

    O1/2" [13]

    3/4" [19]

    1 1/2" [38]2" [51]

    UNIT SIZE W L

    10 32 48

    20 26 41

    30 26 41

    50 44 54

    UNIT SIZE L W

    10 813 1219

    20 660 1041

    30 660 1041

    50 1118 1372

    IMPERIAL UNITS (INCHES)

    SI UNITS (mm)

    NOTES: HANGER BRACKETS ARE 12 GAUGE ZINC COATED STEEL 4 PER FAN UNIT (6 FOR SIZE 50, 14x8), 2 PER DISCHARGE

    ATTENUATOR, 2 PER INLET ATTENUATOR BRACKETS ARE SHIPPED LOOSE FOR FIELD INSTALLATION FOR

    USE WITH THREADED HANGER RODS (BY OTHERS) LAYOUT INDICATES SUGGESTED HANGER BRACKET LOCATIONS

    ••

    L

    W

    1 25 TYP

    FDCLP2 WITH WATER COIL

    1 25 TYP

    W

    1 25 TYP

    L 1 25 TYP

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    ACCESSORIES

    HANGER BRACKETS [HB]LOCATIONS

    FOR FDCLP2 / FDCLP2-DOAS266727

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 4 4© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    C FDCLP2-1-1

    UNIT SIZE W L

    10 32 48

    20 26 41

    30 26 41

    50 44 54

    UNIT SIZE L W

    10 813 1219

    20 660 1041

    30 660 1041

    50 1118 1372

    IMPERIAL UNITS (INCHES)

    SI UNITS (mm)

    3 3/16" [81]

    1" [25]

    O1/2" [13]

    3/4" [19]

    1 1/2" [38]2" [51]

    FDCLP2 SIZE 50 14X8 WITHRETURN SILENCER

    FDCLP2 SIZE 10-50 WITHRETURN SILENCER

    W L

    1 25 TYP

    5 127 TYP

    W L

    1 25 TYP

    5 127 TYP

    1 25 TYP

    UNIT HANGER BRACKET3 3/16" [81]

    1" [25] 1/2" [13]1 1/2" [38]

    3/4" [19]

    O1/2" [13]

    SENSIBLE COOLING COIL HANGER BRACKET

    SENSIBLE COOLING COIL HANGERBRACKETS MOUNT FLUSHWITH FLANGE ON COIL INLETDO NOT SCREW THROUGH TUBES

    SENSIBLE COOLING COIL HANGERBRACKETS MOUNT FLUSHWITH FLANGE ON COIL INLETDO NOT SCREW THROUGH TUBES

  • ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

    0

    RETURN SILENCER

    FDCLP2-DOASALL SIZES

    271378

    PROJECT:

    ENGINEER:

    CUSTOMER:

    SUBMITTAL DATE: SPEC. SYMBOL:

    Submittal Sheet

    06/25/2020

    OF REVSHEET 1 1© Copyright PRICE INDUSTRIES 2020

    So

    lid E

    dge

    FDCLP2-1-1

    B C B C

    10 43 1/2 7 1/2 1105 191

    20/30 36 1/2 10 927 254

    50 50 10 1270 254

    UNIT SIZEIMPERIAL UNITS (INCHES) SI UNITS (mm)

    STANDARD CONSTRUCTION: MEDIUM PRESSURE STYLE, 22 GAUGE GALVANIZED CASING WITH PERFORATED LINER

    OVER FIBERGLASS ACOUSTIC MEDIA.•

    SIZE 10, 20, 30, 50

    PRIMARY

    AIRDISCHARGE

    AIR

    RETURN SILENCER RETURN

    AIR

    B

    C

    13 330

    12 305

    1 25

    SENSIBLE COOLING COIL

    SIZE 50/14x8

    PRIMARY

    AIR

    DISCHARGE

    AIR

    SENSIBLE COOLING COIL

    RETURN SILENCER RETURN

    AIR

    266718-C (003).PDF266719-C.PDF266720-B.PDF266722-D.PDF241538-O.PDF266727-C.PDF271378-0.PDF