submittal data: pla-a24ba & puy-a24nha 24,000 btu/h ... · air intake grille air outlet hole air...
TRANSCRIPT
-
Job Name: Location: Date:
Purchaser: Engineer:
Submitted to: For Reference Approval Construction
Unit Designation: Schedule No.:
Cooling*Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24,000 Btu/hMinimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000 Btu/hSEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13.6 Btu/h/WTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2,500 WPower Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 HzBreaker Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 A* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB.Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB.
VoltageIndoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230VIndoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC 24VIndoor - Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . .DC 12V
Operating range
Indoor Intake Air Temp. Outdoor Intake Air Temp.
Cooling Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB
115ºF (46ºC) DB
Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB
0ºF** (-18ºC) DB
** With optional wind baffle accessory installed. If not installed, the minimum temperature will be 23ºF (-5ºC) DB.
Indoor Unit: PLA-A24BA
Outdoor Unit: PUY-A24NHAindoor UnitMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.51 F.L.A.Fan Motor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 WAirflow (Lo - M1 - M2 - Hi) . . . . . . . 420 - 490 - 570 - 640 Dry CFM 390 - 460 - 530 - 600 Wet CFMSound Level (Lo - M1 - M2 - Hi) . . . . . . . . . . 28 - 29 - 31 - 32 dB(A)
DiMenSiOnS Unit inCHeS / MM paneL inCHeS / MMW 33-1/16 / 840 37-3/8 / 950D 33-1/16 / 840 37-3/8 / 950H 10-3/16 / 258 1-3/8 / 35
Weight (Unit/Grille)lbs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 / 13kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 / 6Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4" / 32 mmWall-mounted Remote Controller . . . . . . . . . . . . . . . . . PAR-21MAA
(See Data Submittal Sheet)
Outdoor UnitCompressor . . . . . . . . . . . . . . . . . . . . . . DC Inverter-driven RotaryMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .…18 AFan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.75 F.L.A.Sound Pressure Level . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 dB(A)
DiMenSiOnS inCHeS / MMW 37-3/8 / 950D 13 + 1-3/16 / 330 + 30H 37-1/8 / 943
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 lbs. / 74 kgRefrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410ARefrigerant Pipe Size O.D. Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8" / 15.88 mm Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9.52 mmMax. Refrigerant Pipe Length. . . . . . . . . . . . . . . . . . . . . 165' / 50 mMax. Refrigerant Pipe Height Difference . . . . . . . . . . . . 100' / 30 mConnection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared
SUbMittaL Data: pLa-a24ba & pUY-a24nHa 24,000 btU/H CeiLing CaSSette air-COnDitiOning SYSteM
Remote Controller: PAR-21MAA
OptiOnaL aCCeSSOrieSIndoor Unit•Multi-functionCasement(PAC-SH53TM-E)•AirOutletShutterPlates(PAC-SH51SP-E)•WirelessSignalReceiver(PAR-SA9FA-E)•WirelessRemoteController(PAR-FL32MA)•i-seeSensorCornerPanel(PAC-SA1ME-E)•High-efficiency(MERV10)Filter(PAC-SH59KF-E)Outdoor Unit•M-NETAdapter(PAC-SF80MA-E)•AirOutletGuide(PAC-SG59SG-E)•WindBaffle(WB-PA2)
generaL FeatUreS•Compactside-dischargeoutdoorunit•Quietoperation—indoorandoutdoorunits•Built-indrainliftmechanismforcondensateremoval;liftsto33-7/16in.•Wideairflowpatternforbetterairdistribution•Autowaveairflowinheatingmode—unitindependentlycyclesthroughhorizontalandverticalpositionsformoreevenheatdistribution•Independentvaneadjustment•Automaticfanspeedcontrol•Self-checkfunction—integrateddiagnostics•Advancedmicroprocessorcontrol•Hard-wired,wall-mounted,remotecontroller(PAR-21MAA)•Limitedwarranty:oneyearonpartsanddefectsandsixyearson
compressor
-
Dimensions: PLA-A24BA
14-27/3211-3/162-3/8
+5 0
(7.5
)
+35
-5
(160)
(500
)
(950
)
Floor
Min.94-1/2(2400)from floor
Entireperiphery
(36)(83)
(83)
(36) (500)
(950)
(597
)
(597)
( 1
58)
(ø175)(350)
(ø150)
(14-ø2.8)
(167
)(1
55)
(130
)(1
00)(90) (90)
(100) (100)
(35)
(17
)
+3/1
60
(190
)
(156
)(1
05)
(50~
70)
(140
)
(170
)
(377)(284)(60)
(24)
(187.5)(840)
(160)(1
60)
(20~
45)
to 1
-25/
32(8
60~
910)
(620
)
(605
)-3
/16
+1-
3/8
(90)
(150
)(1
60)
(7.5
)
(20 ~
45)
1-25
/32
Corner pocket
In case of wireless remote controllerIn case of standard grilleDrain lift mechanism cleanhole and Drain emergency drainage hole
For MA-Remote controllerterminal block
Emergency operation switch
Emergency operation switch
Indoor unit
Ceiling
Cut out hole
Burring hole pitch3-ø1/8(3-ø2.8)Burring hole
Detail drawing of ventilation air intake connection
Burring hole14-ø1/8
Cut out hole
Burring hole pitch
Cut out hole
Detail connecting of branch duct (nominal 6"round or nominal 4 x 14" rectangular)
(77)3-1/32
(85)3-11/32
(298)11-3/411-1/16
(281)
(74)(80)(258)(241)2-29/323-5/3210-3/16
PLA-A36BAPLA-A42BA
PLA-A24BAPLA-A30BA
9-1/2
DCBA2
Refrigerant pipe ····ø15.88mmFlared connection····5/8
Refrigerant pipe ····ø12.7mmFlared connection····1/2
1
Refrigerant pipe ····ø6.35mmFlared connection····1/4
Refrigerant pipe ····ø9.52mmFlared connection····3/8
ModelsPLA-A12BAPLA-A18BA
Min.19-11/16(500)
Grille
Ceiling
Suspension bolt lower edge
Vane motor
Air intake grille
Air outlet hole
Air
outle
t hol
e
Auto vane(Air outlet)
Air
inta
ke h
ole
Air intake hole
GrilleCeiling
Keep 25/64(10)to 19/32(15)between unit ceiling and ceiling slab.
)(Connected the attachedflexible pipe or socket.Drainpipe connected to1-1/4 in. O.D. PVC tube
Suspension bolt M10 or 3/8
Branch duct hole
Ventilation air intake hole
Branch ducthole
Cei
ling
hole
Sus
pens
ion
bolt
pitc
h
Suspension bolt pitch
Ceiling hole
(5/1
6)(5
/16)
23-1
3/16
24-1
3/32
DEFROST/STAND BY lampReceiverOperation lamp
For wiring replacement kit terminal block
6-5/16
6-5/16
1
2
3-15
/16
5-1/
8
13-25/32
3-17/32
3-15/16 3-15/16
3-17/32
* 6-9
/16
* 6-3
/32
ø5-29/32
ø6-7/8
19-11/16
19-1
1/16
23-1/2
M
M
M
M
3-17/641-27/64
37-3/8
3-17
/64
1-27
/64
37-3
/8
23-1
/2
1-15
/16~
2-3/
4
* 5-
1/2
* 6-
11/16
1-3/
8
11/1
6
* 4-
1/8
* 6-
9/64
* 7-
15/3
2 A
* B
6-5/
16
33-1
/16(
840)
5-29
/32
3-17
/32
C D
33-1/16
7-3/8
25/32 to 1-25/32(20~45)25/32 to 1-25/32(20~45) 33-27/32 to 35-13/16(860~910)
31-7/8(810)
25/3
2 to
33-2
7/32
to 3
5-13
/16
25/3
2
15/1
66-
5/16
Indoor unit/Outdoor unit connecting terminal block
ø4-29/32(ø125)
ø3-15/16(ø100)
6-7/
32 120
˚
120˚
**
Note1. Use 1-1/4 in. O.D. (32) PVC TUBE.Drain lift mechanism is included.
2. Suspension bolt, use M10 or W3/8. (Field supplied)
3. Electrical box may be removed for service purposes.Make sure to slack the electrical wire little bit for control/power wires connection.
4. The height of the indoor unit is adjustable with the grilleattached.
5. For the installation of the optional high efficiency filter,the optional multi-functional casement is required.1) Add 5-5/16 (135mm) to the dimensions marked with an * in the figures 2) The optional high efficiency filter required optional
multi-functional casement.6. When installing the branch ducts, be sure to insulate adequately.
Otherwise condensation may occur.7. As for necessary installation/service space, please refer to the
bottom left figure.
-
Min.
10m
m
<3/
8>M
in. 1
0mm
Min.
100
mm
M
in. 5
00m
m
Max.
100mmMin.
500mmMin.
500m
mM
in.
10m
mM
in.
Ser
vice
spa
ce
30mm
FOUN
DATIO
N
FREE
31
74
40
Whe
n in
stal
ling
the
cond
uit,
Set t
he a
ttach
men
t to
the
inne
r sid
e of
eac
h pa
nel.
1/2 C
ondu
it atta
chme
nt2-ø
22.2<
7/8>
330
175
600
175
53
28 370 19
56
45
42 <
1-21
/32>
66 <
2-5/
8>
417
2-U S
hape
d notc
hed h
ole(F
ound
fation
Bolt
M10
)
Side
Air
Inta
ke
Rear
Air
Inta
ke
Air D
ischa
rge
2-12*
36 ov
al ho
le(F
ound
ation
Bolt
M10
)
30
Side A
ir Inta
ke
Hand
le
Rear
pipi
ng co
ver
Fron
t pipi
ng co
ver
81219
145
22
0 <
8-21
/32>
30 <
1-3/
16>
145
71
71 <
2-13
/16>
145
Botto
m p
iping
hole
(Kno
ckou
t)
Drain
hole
(5-ø
33
)
Hand
le
Hand
le
Rear
Air In
take
Air
Inta
ke
670
*1 443
*1 447
322
950
473
943
23
21
Hand
le
Hand
le
Serv
ice p
anel
Earth
term
inal
Left··
·Pow
er su
pply
wirin
gRe
ight···
Indoo
r/Outd
oor w
iring
Term
inal B
lock
63 73
75
40 <
1-9/
16>
92
9227 23
55
19
Cond
uit ho
le (2-
ø27<
1-1/16
>Kno
ckou
t)Ri
ght tr
unkin
g hole
(Kno
ckou
t)Ri
ght p
iping
hole
(Kno
ckou
t)
ø92
45
65
92
40 <
1-9/
16>
63
2373
55 27
Cond
uit ho
le (2-
ø27<
1-1/16
>Kno
ckou
t)
Fron
t trun
king h
ole(K
nock
out)
Fron
t pipi
ng ho
le(K
nock
out)
ø92
40 <
1-9/
16>
45
6373 23
55 27
92
65
Cond
uit ho
le (2-
ø27<
1-1/16
>Kno
ckou
t)Re
ar tru
nking
hole
(Kno
ckou
t)
Rear
piping
hole
(Kno
ckou
t)
ø92
Pipi
ng a
nd w
iring
con
nect
ions
can
be m
ade
from
4 d
irect
ions
:fro
nt, r
ight
, rea
r and
bel
ow.
Dim
ensio
ns o
f spa
ce n
eede
dfo
r ser
vice
acce
ss a
resh
own
in th
e be
low
diag
ram
.
Plea
se s
ecur
e th
e un
it fir
mly
with
4 fo
unda
tion
(M10
)
bolts
. (Bo
lts a
nd w
ashe
rs m
ust
be p
urch
ased
loca
lly.)
The
diag
ram
bel
ow s
hows
aba
sic e
xam
ple.
Expl
antio
n of
par
ticul
ar d
etai
ls ar
egi
ven
in th
e in
stal
latio
n m
anua
ls et
c.
1···
·Ref
riger
ant G
AS p
ipe
conn
ctio
n (F
LAR
E)[1
5.88
2
····R
efrig
eran
t LIQ
UID
pip
e co
nnec
tion
(FLA
RE)[
9.52
*1
····I
ndic
atio
n of
STO
P VA
LVE
conn
ectio
n lo
catio
n.
Exam
ple
of N
otes
Pipi
ng K
nock
out H
ole
Deta
ils
1 FR
EE S
PACE
(Aro
und
the
unit)
2 SE
RVIC
E SP
ACE
3 FO
UNDA
TION
BOL
TS4
PIPI
NG-W
IRIN
G DI
RECT
IONS
Dimensions: PUY-A24nHA
-
3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice.C SD - PLA-A24BA / PUY-A24NHA - 200710 © MITSUBISHI ELECTRIC / HVAC 2007
noTes
Reference: OffApproval: OffConstruction: OffJob Name: Location: Date: Purchaser: Engineer: Submitted to: Unit Designation: Schedule No: Notes: