Submittal Data Information 101-150 ITEM NO. MODEL NO. EFFECTIVE: November 1, 2014 SUPERSEDES: June 1, 2014 JOB ENGINEER CONTRACTOR REP. PUMP: Casing (Volute): Stainless Steel Stator Housing: Steel Cartridge: 304 Stainless Steel Impeller: Noryl Shaft: Ceramic Bearings: Carbon O-Ring: EPDM INTEGRAL FLOW CHECK (IFC ® ): Body, Plunger: Acetal O-Rings: EPDM TacoGenie Circulator Hard Wire Push Button (2) Copper T’s (2) Flex Hoses Materials of Construction: TacoGenie Includes: TacoGenie Model Numbers Product Number Connection Sizes Motor Ship Wgt. Voltage RPM HP 006-CT 1 2" Male NPT 115/60/1 3250 1 40 7 006-CT-USK 1 2" Male NPT, with Plumbing Kit 1 40 8 008-CT 1 2" Male NPT 1 25 10 008-CT-USK 1 2" Male NPT, with Plumbing Kit 1 25 11 0011-CF 3 4" Shut-off Flange 1 8 14 0011-CF-USK 3 4" Shut-off Flange, with Plumbing Kit 1 8 15 A Taco resource – saving product Application: The TacoGenie provides hot water at your command at the same time it saves water, energy and money. The TacoGenie is a small, silent pump that you attach to the hot and cold water lines in the cabinet under the most remote kitchen or bath fixture in the home. When the TacoGenie pump is activat- ed, the cool water you normally let run down the drain is recircu- lated back to the water heater through the cold water line. TacoGenie, the pump circulates the hot water from the water heater and returns the cooled water back through the cold water line. When the hot water arrives at the fixture, the TacoGenie’s heat sensor and control board shut off the pump to prevent pump- ing excess hot water into the cold water line. NOTE: Standard plumbing and distance requires the TacoGenie to be installed between the hot and cold water line at the most distant hot water location. CT – TacoGenie Threaded USK – Undersink Kit CF – TacoGenie Flanged Nomenclature: TacoGenie System - Accessories Product Number Description What It Does 554-7 Remote Transmitter/ Receiver Kit To start system with wireless remote control 554-8 Individual Remote Transmitter For wireless remote control at multiple locations 554-3 Individual Starter Button For hard-wired starter control at multiple locations 554-4 Motion Sensor Starter Kit For automatic motion detection start ® Motion Sensor Receiver and Transmitter FOR INDOOR USE ONLY.

Upload: others

Post on 13-Jan-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Submittal Data Information 101-150 - TACO - HVACSizing Your TacoGenie Circulator Pump: Dimensional and Weight Data: Performance Field Information - 60 Hz FLOW-GPM 01 23 45 67 8910

Submittal Data Information 101-150

ITEM NO. MODEL NO.

EFFECTIVE: November 1, 2014 SUPERSEDES: June 1, 2014

JOB ENGINEER CONTRACTOR REP.

PUMP:Casing (Volute): Stainless SteelStator Housing: SteelCartridge: 304 Stainless SteelImpeller: NorylShaft: CeramicBearings: CarbonO-Ring: EPDM

INTEGRAL FLOW CHECK (IFC®):Body, Plunger: AcetalO-Rings: EPDM

TacoGenie CirculatorHard Wire Push Button(2) Copper T’s(2) Flex Hoses

Materials of Construction:

TacoGenie Includes:

TacoGenie Model NumbersProductNumber

ConnectionSizes

Motor ShipWgt.Voltage RPM HP

006-CT 1⁄2" Male NPT

115/60/1 3250

1⁄40 7

006-CT-USK1⁄2" Male NPT,with Plumbing Kit

1⁄40 8

008-CT 1⁄2" Male NPT 1⁄25 10

008-CT-USK1⁄2" Male NPT,with Plumbing Kit

1⁄25 11

0011-CF 3⁄4" Shut-off Flange 1⁄8 14

0011-CF-USK3⁄4" Shut-off Flange,with Plumbing Kit

1⁄8 15

A Taco resource – saving product

Application:The TacoGenie provides hot water at your command at the sametime it saves water, energy and money.The TacoGenie is a small, silent pump that you attach to the hotand cold water lines in the cabinet under the most remote kitchenor bath fixture in the home. When the TacoGenie pump is activat-ed, the cool water you normally let run down the drain is recircu-lated back to the water heater through the cold water line.TacoGenie, the pump circulates the hot water from the waterheater and returns the cooled water back through the cold waterline. When the hot water arrives at the fixture, the TacoGenie’sheat sensor and control board shut off the pump to prevent pump-ing excess hot water into the cold water line.NOTE: Standard plumbing and distance requires the TacoGenieto be installed between the hot and cold water line at the mostdistant hot water location.

CT – TacoGenie Threaded USK – Undersink KitCF – TacoGenie Flanged

Nomenclature:

TacoGenie System - AccessoriesProductNumber Description What It Does

554-7 Remote Transmitter/Receiver Kit

To start system withwireless remote control

554-8 Individual RemoteTransmitter

For wireless remote control atmultiple locations

554-3 Individual StarterButton

For hard-wired starter control atmultiple locations

554-4 Motion SensorStarter Kit

For automatic motiondetection start

®

Motion Sensor

Receiver andTransmitter

FOR INDOOR USE ONLY.

Page 2: Submittal Data Information 101-150 - TACO - HVACSizing Your TacoGenie Circulator Pump: Dimensional and Weight Data: Performance Field Information - 60 Hz FLOW-GPM 01 23 45 67 8910

Sizing Your TacoGenie Circulator Pump:

Dimensional and Weight Data:

Performance Field Information - 60 Hz

FLOW-GPM0 1 2 3 4 5 6 7 8 9 10

TOTA

L HE

AD -

FEET

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

FLOW-M3/H0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25

0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.0

006-CT-USK008-CT-USK0011-CF-USK

123

1

3

TacoGenie Models

2

TOTA

L HE

AD -

MET

ERS

STANDARD PIPING - Tank Type Water HeaterSize of Home Total Length of Pipe (ft) Model

Small 50 006Medium 100 008

Large/Commercial Over 100 0011

STANDARD PIPING - Tankless Water HeaterSize of Home Total Length of Pipe (ft) ModelSmall/Medium < 60 008

Large/Commercial > 60 0011

RECIRCULATION PIPING - Tank Type Water HeaterSize of Home Total Length of Pipe (ft) Model

Small 100 006Medium 200 008

Large/Commercial Over 200 0011

RECIRCULATION PIPING - Tankless Water HeaterSize of Home Square Feet ModelSmall/Medium < 2500 008

Large/Commercial > 2500 0011

G

F

E

C

D

AB

MODEL 006-CTA B C D E F G

Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm67⁄32 158 411⁄16 119 31⁄2 89 615⁄16 176 7 178 321⁄32 93 521⁄32 144

Page 3: Submittal Data Information 101-150 - TACO - HVACSizing Your TacoGenie Circulator Pump: Dimensional and Weight Data: Performance Field Information - 60 Hz FLOW-GPM 01 23 45 67 8910

Dimensional and Weight Data (continued):

G

F

E

C

D

A

B

MODEL 008-CTA B C D E F G

Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm61⁄2 165 45⁄8 118 4 102 7 178 87⁄32 209 321⁄32 93 521⁄32 144

G

F

E

C

D

A

B

MODEL 0011-CFA B C D E F G

Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm71⁄2 191 61⁄8 156 31⁄2 89 79⁄16 192 61⁄2 165 4 102 65⁄8 168

Page 4: Submittal Data Information 101-150 - TACO - HVACSizing Your TacoGenie Circulator Pump: Dimensional and Weight Data: Performance Field Information - 60 Hz FLOW-GPM 01 23 45 67 8910

TACO, INC., 1160 Cranston Street, Cranston, RI 02920    Telephone: (401) 942-8000    FAX: (401) 942-2360.TACO (Canadá), Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8.    Telephone: 905/564-9422.    FAX: 905/564-9436.Visit our web site at: http://www.taco-hvac.com

Printed in USA

Copyright 2014

TACO, Inc.