Drawing Description Drawing No.
Drawing Register CB 001 - 002
Introduction Series 000Sto Concrete Block Construction & Detailing CB 003Sto Concrete Block Construction & Detailing CB 004Sto Concrete Block Construction & Detailing CB 005Sto Concrete Block Plaster System CB 006
Block Layout Series 100Sto Concrete Block Stoarmat Miral System - Isometric CB 100
Foundation Series 200Sto Concrete Block Rebated Slab-on-Ground CB 200Sto Concrete Block Non-Rebated Slab-on-Ground CB 201Sto Concrete Block Strip Footing Detail CB 202Sto Concrete Block Tanking to Plaster Transition CB 203 Walls Series 300Sto Concrete Block Vertical Control Joint CB 300Sto Concrete Block Stair Waterproofing Detail CB 301 Sto Concrete Block Inter-Storey Slab Detail CB 302
Wall Penetrations & Fittings Series 350Sto Concrete Block Pipe Penetration (up to 150mm Ø) Detail CB 350Sto Concrete Block Meterbox CB 351Sto Concrete Block Fan Vent Detail CB 352Sto Concrete Block Architectural Profile CB 353Sto Concrete Block Handrail CB 354Sto Concrete Block RWH/Scupper Opening CB 355
Joinery Series 400Sto Concrete Block Alu.Joinery - Head & Sill Detail CB 400Sto Concrete Block Alu.Joinery - Jamb Detail CB 401Sto Concrete Block Alu.Entry Door Head & Threshold Detail CB 402Sto Concrete Block Alu.Entry Door Jamb Detail CB 403Sto Concrete Block Timber Joinery - Head & Sill Detail CB 404Sto Concrete Block Timber Joinery - Jamb Detail CB 405Sto Concrete Block Timber Entry Door Head & Threshold Detail CB 406Sto Concrete Block Timber Entry Door Jamb Detail CB 407
Parapets, Balustrades, Decks Series 500Sto Concrete Block Parapet/Metal Flashing Detail CB 500Sto Concrete Block Plastered Parapet/Balustrade Detail CB 501Sto Concrete Block Uncoated, Painted, Clear Coated or Plastered Parapet Detail CB 502Sto Concrete Block Parapet/Roof/Wall Detail CB 503Sto Concrete Block StoFlexyl Waterproofing Membrane - Isometric CB 504
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE ISRESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALLWATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
STO DRAWING REGISTER
PAGE 1 OF 2
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
DRAWING REGISTER
CB 001
2014
Drawing Description Drawing No.
Soffit Series 600Sto Concrete Block Eaves with Overhang CB 600
Sto Concrete Block Eaves without Overhang CB 601
Sto Concrete Block Barge with Overhang CB 602
Sto Concrete Block Roof to Conc.Block Gable End CB 603
Sto Concrete Block Raking Soffit (Reversed) CB 604
Roof Series 700Sto Concrete Block Gable End/Roof Junction CB 700
Sto Concrete Block Apron Flashing CB 701
Sto Concrete Block Parallel Roof/Hidden Gutter CB 702
Sto Concrete Block Face Fixed Fascia/Membrane Roof CB 703
Dissimilar Material
Bevel-Back Weatherboard Series 800Sto Concrete Block Ext.Corner CB 800
Sto Concrete Block Int.Corner CB 801
Sto Concrete Block Horizontal Junction CB 802
Brick Series 810 series not issued
Fibre Cement Sheet Series 820 series not issued
Manufactured Stone - Schist & Natural Stone Series 840 series not issued
Profile Metal Series 850Sto Concrete Block Ext.Cnr Horiz.Profiled Metal CB 850
Sto Concrete Block Int.Cnr Horiz.Profiled Metal CB 851
Sto Concrete Block Horizontal Junction Horiz.Profiled Metal CB 852
Sto Concrete Block External Corner Vertical Profiled Metal CB 853
Sto Concrete Block Internal Corner Vertical Profiled Metal CB 854
Sto Concrete Block Horiz.Junction Vertical Profiled Metal CB 855
Stotherm Panel EIPS 860 series not issued
DISSIMILAR JOINERY Series 870 series not issued
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 2 OF 2
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
DRAWING REGISTER
CB 002
2014
ENSURE CONC.BLOCK WALLS ARE
SUPPORTED DURING CONSTRUCTION
45mm MIN.REBATE IS RECOMMENDED
A NON-REBATED FOUNDATION
REQUIRES 100mm STO FLEXYL
MESHED WATERPROOFING STRIP
CENTERED OVER FLOOR JOINT
NOTE:
1. MAIN CONTRACTOR IS TO ENSURE SEPARATE WALLS, STAIRS or DISSIMILAR
MATERIAL AGAINST BLOCKWORK ARE WATERPROOFED AS NECESSARY TO
FORM A WATERTIGHT CONNECTION WITH THE STO PLASTER SYSTEM2. IT IS CRITICAL IN PARTIALLY FILLED BLOCKS THAT JOINTS ARE TOOLED FOR
EARTHQUAKE RESISTANCE
3. MASONRY CONCRETE BLOCKS as per NZS4210 / 4229 &4230 or SPECIFIC
ENGINEER DESIGN
4. ALLOW ADEQUATE TIME FOR BLOCKS TO DRY/STABILISE BEFORE PLASTERING.
IN NORMAL DRYING CONDITIONS 4-8 WEEKS
5. CONTROL JOINTS - REFER ENGINEERS SPECIFICATION, BLOCK
MANUFACTURERS RECOMMENDATION or NZS4229
SILL BLOCKS SHOULD BE FILLED.
CREATE OPENING TO ENABLE BLOCK
MORTAR TO FLOW THROUGH. REMOVE
PROJECTING SILL FOR A FLUSH FINISH
MORTAR = 10mm +/- 3mm
ALLOW MORTAR JOINTS TO BE
TOOL COMPRESSED
SCALE 1:20
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
CONSTRUCTION & DETAILING
CB 003
2014
CONCRETE BLOCK CONSTRUCTION & DETAILING
ResponsibilityAll work in this section shall be the responsibility of the Main Contractor . All concrete block
construction must be in accordance with the project drawings, specifications and block
manufactures technical data. The Main Contractor is to ensure they are fully conversant with all Stostandard installation and fixing details (Sto ACAD details www.sto.co.nz) and their responsibilities
before the block works commences. The Main Contractor is also responsible for all liaison with the
various sub contractors to ensure that all items or elements affecting the Sto Plaster System are
correctly detailed before installing the StoArmat Miral Plaster System.
Concrete BlocksThe concrete block installation including reinforcement and concrete infill shall be made in strict
accordance with the project drawings, specifications and the block manufactures technical
documentation. In particular the blocks shall be laid true in both vertical and horizontal planes with all
joinery and service openings correctly formed and waterproofed in accordance with Sto details.Control joints must be installed as per the projects structural drawings or manufactures details to
manage shrinkage and structural stress. The ground floor slab to block junction should be rebated to
provide waterproofing and inter-storey floors should be poured within the block structure leaving the
outer block shell to continue to avoid cracking. At least 28 days should be allowed after concrete
placement - as per AS/NZS 2311:2000 for curing and stabilization to take place before commencing
the StoArmat Miral Plaster System. All maximum tolerances shall be in strict accordance with
NZS4210:2001 2.7.1.4, Table 2.2 IE: no more than 3mm surface alignment deviation over a 1200mm
radius. The concrete blocks shall be clean, dry and free of all surface contaminants before plastering
and the Main Contractor is to ensure that any area or details adjacent to the Sto Plaster System have
been adequately waterproofed or flashed to avoid any water migration behind the plaster system.
Construction Block Construction
• A rebate is recommended in foundations for residential projects unless an exterior insulation
system is detailed.
• Joinery openings are to be formed using rebated blocks & sill blocks (cut sill flush as required).• Blocks should be covered on site and laid dry.
• Vertical control joints are placed at 6.0M max.centres - refer project documentation and NZS4229
for placement and detailing.
• Mortar to be 12.5MPa min.tool smooth and compressed as per NZS4210
• Manufacturers bagged mortar is recommended to meet the specifications
• Mortar to full depth of webbing up to 20MM thick in first course and then 10MM +/- 3mm
• Washout ports required to remove mortar droppings from foundation
• Ensure there is no impediment to grout flow, remove ends or biscuits to prevent air pockets
• Stack bonded, column blocks and insulation block voids may need to be grouted by the block
layer during laying process to ensure a solid fill is achieved
• Blocks should be filled in 1.2 lifts and mechanically vibrated to avoid air voids and subsequence
efflorescence
• Sill block should be filled by leaving one sill block out to avoid air entrapment
• Remove any grout slurry from block faces before it sets
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
CONSTRUCTION & DETAILING
CB 004
2014
CONCRETE BLOCK CONSTRUCTION & DETAILING......cont.
Construction Block Construction
• Drying times vary according to block thickness, grout and weather. A min.28days is
required for settlement & curing - the blocks must be completely dry before coating
• Where occupied walls are back filled a 50 year tanking membrane is required.
• Always waterproof blocks behind or adjacent to any overlays or abutments such as
concrete staircases, separate adjoining garden walls, soffits, porches, posts etc.
• Exposed tops of walls require waterproofing and should be finished with block caps
Exterior Insulation - refer to Sto Concrete Block Insulation Details
NZBC Acceptable Solution H1/AS1 or NZBC Verification Method H1/VM1 can be used for housing,
communal residential, communal non-residential and commercial buildings. For buildings with a
glazing area of 30% or less of the total wall area, the minimum wall R-values required for solid
construction are:
Climate Zone 1 (Nth Coromandel) - R0.8 (option 1a and 1b)
Climate Zone 2 Nth Island, Sth Coromandel excluding the Central Plateau - R1.0 (option 2a) or R0.9
(option 2b)
Climate Zone 3 Sth Island and Central Plateau) - R1.2 (option 3a) or R1.0 (option 3b)
Refer to the BRANZ House Insulation Guide Third Edition for further information and construction
R-values for concrete block construction with External Insulation.
Interior InsulationGenerally involves 90mm framing inside and installing insulation to meet 1.9 or 2.0 R-Value
Note: H1 Insulation - Internally insulated masonry walls must meet the timber insulation code
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
CONSTRUCTION & DETAILING
CB 005
2014
STO CONCRETE BLOCK PLASTER SYSTEM
StoArmat Reinforced Plaster System
To combat fractures and stress that can occur in concrete block construction during the curing and
settling process. The StoFlexyl waterproofing membrane is to ensure openings, junctions,
terminations and overlays are waterproofed.
SS202 STOARMAT MIRAL PLASTER SYSTEM BRANZ APPRAISAL CERTIFICATE No.515
INCORPORATING:
1. Stoflexyl Waterproofing 18Kg pail plus cement evaluated by BRANZ to meet AS/NZS4858
waterproofing membrane requirements as required by NZBC E2/AS1
2. Levellite Base Plaster 20Kg bag mineral fibre reinforced based plaster with EPS bead for levelling
and straightening walls. Can be machine applied
3. StoArmat Classic Plaster 23Kg pail European fibre reinforced non-cement based crack resistant
plaster used with European mesh as a reinforcement plaster
4. Stolit Coloured Finishing Render in 25Kg Pail
Stolit K - 1.0mm Coloured Float Finish Render
1.5mm Coloured Float Finish Render
2.0mm Coloured Float Finish Render
3.0mm Coloured Float Finish Render
Stolit - MP Fine Sponge or Adobe Coloured Finishing Render
MP Natural Sponge or Adobe Coloured Finishing Render
Milano Smooth or Adobe Coloured Finishing Render
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
PLASTER SYSTEM
CB 006
2014
SCALE 1:20
STOARMAT MIRAL PLASTERSYSTEM - SS202
STOLIT K COLOURED FINISH RENDER
1.0, 1.5, 2.0 & 3.0mm FLOAT FINISH.
STOLIT MP COLOURED FINISH RENDER
MP, MP NATURAL & MILANO FINE FINISH
BASECOAT: LEVELLITE 6/8mm
PLASTER
REINFORCEMENT: STOARMAT
CLASSIC PLASTER
PLUS: STO EUROPEAN MESH
FINISHING RENDER: STOLIT K
& MP RANGE
SKIM COAT: STOARMAT
CLASSIC PLASTER
COATING/STO COLOR:
:MAXICRYL MATT FACADE PAINT
:LASTIC SATIN FACADE PAINT
:LOTUSAN MINERAL RESIN PAINT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
STOARMAT MIRAL PLASTER SYSTEM - ISOMETRIC
CB 100
2014
CONCRETE SLAB/REINFORCING
AS PER NZS 4229 & 4210 ORENGINEER SPECIFIC DESIGN
INSULATION as per NZBC - H1
CONCRETE MASONRY WALL
50
DPM
50
100m
m
150
SCALE 1:5
DPC
SLAB
INSULATION
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
REBATED SLAB-ON-GROUND
CB 200
2014
SCALE 1:5
CONCRETE SLAB/REINFORCING AS PER
NZS 4229 & 4210 OR ENGINEER SPECIFIC
DESIGN
STO FLEXYL
WATERPROOFING
SHALL EXTEND
ABOVE GROUND BY
AT LEAST 150mm AND
IF DPM IS APPLIED
TO THE EXTERNAL
FACE OF FOOTING IT
SHALL OVERLAP BY
AT LEAST 50mm
INSULATION as per NZBC - H1
CONCRETE
MASONRY WALL
STOARMAT MIRAL
PLASTER SYSTEM
100mm STOFLEXYL
MESH OVER SLAB TO
BLOCK JUNCTION
STOFLEXYL - BRUSH
SHEETS & FOUNDATION
ADHESIVE MORTAR TO
FACE AND MECHANICAL
FIX @ 600mm CTRS
ABOVE GROUND
SCABBLE SLAB SURFACE
FOR BLOCK BOND
DPM REQUIRED
FOR POORLY
DRAINED SITES
100m
m
paved
150m
m
unpaved
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
NON-REBATED SLAB-ON-GROUND
CB 201
2014
NOTE:REFER TO NZS 4229 or
SPECIFIC DESIGN FOR
DIMENSION, REINFORCING
AND GROUND CLEARANCES
SCALE 1:10
see note
see note
150
CONCRETE MASONRY
WALL
INSULATION as per
NZBC - H1
STOFLEXYL WATERPROOFING
SHALL EXTEND ABOVE GROUND
BY AT LEAST 150mm AND IF DPMIS APPLIED TO THE EXTERNAL
FACE OF FOOTING IT SHALL
OVERLAP BY AT LEAST 50mm
50
G.L
STOARMAT MIRAL
PLASTER SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
STRIP FOOTING DETAIL
CB 202
2014
STOARMAT MIRAL
PLASTER SYSTEM
TANKING SEALANT
COMPRESSION BAR
MECHANICALLY FIXED TO
CONC.BLOCK
GRANDULAR FILL
RECOMMENDED
SELECTED BITUMOUS
PEEL & STICK TANKING
MEMBRANE
WITH PROTECTION
MATERIAL
TRANSITION APPROX.100mm
BELOW GROUND
NOTE:REFER TO NZS 4229 or
SPECIFIC DESIGN FOR
DIMENSION & REINFORCING
150
100
STOFLEXYL MESHED
WATERPROOFING FROM
150mm ABOVE GROUND
AND DOWN OVER
COMPRESSION BAR
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
TANKING TO PLASTER TRANSITION
CB 203
2014
SCALE 1:20
VERTICAL CONTROL JOINTS AT BLOCK
CONTROL JOINTS - NORMALLY @6.0M
CENTERS or AS PER PROJECT DRAWINGS
BASECOAT: LEVELLITE 6/8mm
REINFORCEMENT: STOARMAT
CLASSIC
STO 8 mm uPVC JOINT IN
STOARMAT MESH COAT
FINISHING RENDER: STOLIT K
& MP RANGE
NOTE:WHEN FITTING THE STO CONTROL JOINT, PULL TAB 75mm OUT TO ENSURE
EASIER REMOVAL. BED JOINT IN STOARMAT CLASSIC MESH COAT. THE
FINISHED JOINT MUST BE COATED FOR NEGATIVE DETAIL or FILLED WITH
MS SEALANT. REMOVE TABS AS SOON AS JOINT IS SET TO AVOID
CRACKING
BLOCK CONTROL JOINT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
VERTICAL CONTROL JOINT
CB 300
2014
STOFLEXYL WATERPROOFING 150mm
MIN.ABOVE & BELOW STAIRS WITH 50mm
MIN.UNDER PLASTERED STAIRS or TILE
MEMBRANE
INSULATION AS PER
NZBC - H1
CONCRETE MASONRY
WALL (20 Series shown)
APPLY STOFLEXYL MESHED BAND ON
CONC.BLOCKS 150mm MIN. ABOVE AND 150mm
BELOW STAIRS BEFORE BOXING - APPLY
STOFLEXYL MESH, 50mm MIN.ONTO STAIRS
ONCE CONCRETE HAS CURED BEFORE
PLASTERING OR APPLYING TILE MEMBRANE
10
0
50mm
STOFLEXYL WATERPROOFING MEMBRANE
• WALL CAPS, PARAPETS, BALUSTRADE TOPS
• JOINERY OPENINGS
• TIMBER OVERLAYS & SOFFITS
• STAIRS
• ADJACENT GARDEN WALLS
• FOUNDATIONS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
STAIR WATERPROOFING DETAIL
CB 301
2014
INTER-STOREY FLOOR
SLAB - REINFORCING NOTSHOWN FOR CLARITY
STOARMAT MIRAL
PLASTER SYSTEM
STOFLEXYL MESH COAT
OVER FLOOR JUNCTION IF
FLOOR SLAB PENETRATES
EXT.CONC.BLOCK
INSULATION AS PER
NZBC - H1
CONCRETE MASONRY
WALL (20 Series shown)
DPC
SCALE 1:10
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
INTER-STOREY SLAB DETAIL
CB 302
2014
5° MIN.SLOPE TO OUTSIDE
INTERIOR EXTERIOR
8/10mm SEALANT BEAD ON PEFROD BETWEEN PIPE AND PLASTER
PIPE OR OTHER PENETRATIONSLOPED DOWNWARD - TOWARD THEOUTSIDE
INSULATION AS PER NZBC - H1
CONCRETE MASONRY WALL
SECURE PIPE, APPLY SEALANTPLASTER AND REAPPLY SEALANT ONMESH COAT BEFORE FINISHING
SCALE 1:5
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
PIPE PENETRATION DETAIL (up to150mm)
CB 350
2014
METER BOX AT SILL
METER BOX AT HEAD
PREPARE REBATES, AND APPLY
TWO (2) COATS OF STOFLEXYL
WATERPROOFING BEFORE
APPLYING STOARMAT MIRAL
PLASTER SYSTEM. LEAVE 10mm
SEALANT JOINT
STOARMAT MIRAL PLASTER
SYSTEM
MS SEALANT OVER STO JOINT
SEAL TAPE TO PERIMETER OF
METERBOX
PREPARE REBATES, APPLY TWO (2)
COATS OF STOFLEXYL
WATERPROOFING BEFORE APPLYING
STOARMAT MIRAL SYSTEM. LEAVE
10mm SEALANT JOINT
APPLY STOARMAT MIRAL PLASTER
SYSTEM WITH STO uPVC DRIP EDGE
AT HEAD
MS SEALANT OVER STO
JOINT SEAL TAPE
THICKEN BASECOAT ON REBATES TO
ACHIEVE A 6-8mm FINISHING GAP
BEFORE SEALING
SCALE 1:5
POLYSTYRENE
INSULATION TO SUIT
PROVIDE
AIRSEAL
PROVIDE
AIRSEAL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
METER BOX
CB 351
2014
SLO
PE
TO
OU
TS
IDE
LEAVE 40mm DRAINAGE
GAP IN MIDDLE
INSULATION AS PER NZBC - H1
CONCRETE MASONRY WALL
MS SEALANT TO PERIMETER
SCALE 1:5
STOARMAT MIRAL PLASTER
SYSTEM
FA
N V
EN
T C
OV
ER
MS SEALANT AT PIPE
JUNCTION (FIX FAN COVER TOFLEXIBLE PIPE AS PERMANUFACTURERSINSTRUCTION) USE STO JOINT
SEAL TAPE TO SEAL TO
CONCRETE BLOCK
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
FAN VENT DETAIL
CB 352
2014
SCALE 1:5
ADHESIVE ADHERE
ARCHITECTURAL PROFILES
AND USE STOTHERM FIXINGSAS NECESSARY
INSULATION AS PER NZBC - H1
CONCRETE MASONRY WALL
PREMESHED ARCHITECTURAL
PROFILE OVER STOARMAT/MESH
COAT
STOARMAT MIRAL PLASTER
SYSTEM
MESH COAT UNDER PROFILE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
ARCHITECURAL PROFILE
CB 353
2014
ROOF SCREEDTO A FALL -
MIN FALL1.5°
CONCRETEROOF SLAB
SCALE 1:5
STOFLEXYL MESHEDWATERPROOFING WITH75mm DOWNTURM OVERBASECOAT FINISHED INSTOARMAT MIRAL PLASTERSYSTEM
75
75
INSULATION AS PERNZBC - H1
METAL OVERFLASHING SEALED INTOWALL CHASE (20mm x 10mm) & WITH
MASONRY FIXINGS
SELECTED ROOFMEMBRANE
ROOF MEMBRANE FLASHINGCHASED INTO WALL
SELECTED CONC.BLOCKSERIES (shown 20 seriesconc.block)
HANDRAIL DESIGN & HEIGHT INACCORDANCE WITH NZBCHANDRAIL PLATE ON EPDMGASKET WITH EPDM WASHERSUNDER FIXING WASHERS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
HANDRAIL
CB 354
2014
SCALE 1:5
H3.1 JOISTS,
LAID TO A FALL
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
METAL OVER-FLASHING
TO BE CHASED AND
SEALED INTO WALL
WITH MS SEALANT
STO uPVC FINISHING
EDGE TO PLASTER
70
BACKING ROD & STO SEAL
JOINT INSTALLED AROUND
PERIMETER OF OPENING
PROPRIETARY SCUPPER
OUTLET - CUT TO SUIT
CUSTOM FOLDED RAIN
WATER HEAD
50mm DRIP EDGE
SECURE RWH WITH MASONRY
FIXINGS WITH EDPM WASHER
BETWEEN RWH AND STO
PLASTER FINISH
REBATE INTO
SUBSTRATE
SELECTED MEMBRANE
low point
INSULATION AS
PER NZBC - H1
MASONRY
FIXING
DEBRIS SCREEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
RWH/SCUPPER OPENING
CB 355
2014
10
5
5
INSULATION AS
PER NZBC - H1
20 SERIES CONCRETE
MASONRY WALL
INSULATION AS
PER NZBC - H1
20 SERIES CONCRETE
MASONRY WALL
PREPARE REBATES AND
BRUSH APPLY TWO (2)
COATS OF STO FLEXYL
WATERPROOFING TO
HEAD & JAMB REBATES
BEFORE INSTALLING
JOINERY
STO PREMESHED
DRIP EDGE AT HEAD
MS SEALANT
CONTINUOUS ACROSS
HEAD & DOWN JAMBS
REMOVE
PROJECTING SILL
(as requested) -SHOWN DASHED
PROPRIETARY
ALU.WINDOW JOINERY
STOARMAT MIRAL
PLASTER SYSTEM
SCALE 1:5
BRUSHED STOFLEXYL
COAT
PREPARE REBATES AND
APPLY STO FLEXYL MESHED
WATERPROOFING TURNED
40mm UP JAMBS
HEAD DETAIL
SILL DETAIL
5
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
ALUMINIUM JOINERY - HEAD & SILL DETAIL
CB 400
2014
SCALE 1:5
5
INSULATION AS PER
NZBC - H1
20 SERIES CONCRETE
MASONRY WALL - REINFORCED
AS PER NZS 4229
PREPARE REBATES; BRUSH APPLY
TWO (2) COATS OF STO FLEXYL
WATERPROOFING TO JAMB & HEAD
REBATES BEFORE INSTALLING
JOINERY
MS SEALANT CONTINUOUS AROUND
HEAD & JAMBS
PROPRIETARY
ALU.WINDOW JOINERY
STOARMAT MIRAL
PLASTER SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
ALUMINIUM JOINERY - JAMB DETAIL
CB 401
2014
5
INSULATION AS PER
NZBC - H1
20 SERIES
CONCRETE
MASONRY WALL
PROPRIETARY ALU.DOOR
JOINERY
SCALE 1:5
STO PREMESHED DRIP EDGE
MS SEALANT CONTINUOUS
AROUND HEAD & JAMBS
TIMBER SILL - ADJUST
PACKER TO SUIT FLOOR
COVERINGS
STOARMAT MIRAL
PLASTER SYSTEM -
150mm MIN.FLOOR SLABto GROUND LEVEL100mm MIN.FLOOR SLABto PAVING
LINE OF CONCRETE
BLOCK & FOUNDATION -
SHOWN DASHED
10m
m M
IN
.
PREPARE REBATES AND BRUSH
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO
ALL REBATES BEFORE
INSTALLING JOINERY
5mm
PREPARE REBATES AND
BRUSH APPLY STO FLEXYL
WATERPROOFING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
ALU.JOINERY-DOOR HEAD & THRESHOLD DETAIL
CB 402
2014
SCALE 1:5
5
INSULATION AS PER
NZBC - H1
20 SERIES
CONCRETE BLOCK
AIRSEAL ON PEF ROD GAP
7.5-8mm APPROX & PACKER
PROPRIETARY ALU.DOOR
JOINERY
MS SEALANT CONTINUOUS
AROUND HEAD & JAMBS
STOARMAT MIRAL
PLASTER SYSTEM
PREPARE REBATES AND BRUSH
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO
ALL REBATES BEFORE
INSTALLING JOINERY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
ALUMINIUM JOINERY - JAMB DETAIL
CB 403
2014
SCALE 1:5
INSULATION AS
PER NZBC - H1
20 SERIES CONCRETE
MASONRY WALL
INSULATION AS
PER NZBC - H1
20 SERIES CONCRETE
MASONRY WALL
STO PREMESHED DRIP EDGE
MS SEALANT CONTINUOUS
ACROSS HEAD & DOWN
JAMBS. TIMBER TRIM
TIMBER JOINERY PROFILES
AS PER NZS 3610
STOARMAT MIRAL
PLASTER SYSTEM
AIR SEAL OVER
BACKING ROD
H3.2 TIMBER PACKER ON
DPC UNDER SILL
REMOVE
PROJECTING SILL -
SHOWN DASHED
PREPARE REBATES AND BRUSH
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO ALL
REBATES BEFORE INSTALLING
JOINERY ON DPC & PLASTERING
PREPARE REBATES AND
BRUSH APPLY STO FLEXYL TO
INTERNAL REBATE WITH MESH
WATERPROOFING TURNED
40mm UP JAMBS OVER SILL
STOARMAT MIRAL
PLASTER SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
TIMBER JOINERY - HEAD & SILL DETAIL
CB 404
2014
SCALE 1:5
INSULATION/STAPPING
AND LINING
20 SERIES CONCRETE
MASONRY WALL
MS SEALANT CONTINUOUS
ACROSS HEAD & JAMBS,
TIMBER TRIM
STOARMAT MIRAL
PLASTER SYSTEM
PREPARE REBATES AND BRUSH
APPLY STO FLEXYL MESHED
WATERPROOFING TURNED 40mm
UP JAMBS
AIR SEAL OVER
BACKING ROD
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
TIMBER JOINERY - JAMB DETAIL
CB 405
2014
50
INSULATION/STAPPING AND
LINING
20 SERIES
CONCRETE BLOCK
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO
ALL REBATES OVER BASE
COAT 50mm MIN.UP FACE OF
MASONRY WALL
STO PREMESHED DRIP EDGE
SEALANT OVER BOND
BREAKER CONTINUOUS
ACROSS HEAD & JAMB
TIMBER DOOR JOINERY
PROFILES AS PER NZS 3610
APPLY TWO COATS OF STO
FLEXYL WATERPROFFING TO
ALL REBATES OVER BASECOAT
50mm MIN.DOWN WALL
STOARMAT MIRAL
PLASTER SYSTEM
SCALE 1:5
AIR SEAL OVER
BACKING ROD
*
* REBATE TO SUIT
SILL PROFILE
LINE OF CONCRETE
BLOCK & FOUNDATION -
SHOWN DASHED
50
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
TIMBER DOOR JOINERY - HEAD & SILL DETAIL
CB 406
2014
SCALE 1:5
50
INSULATION/STAPPING AND
LINING (indicative only, notreq.for weathertightness)
20 SERIES
CONCRETE BLOCK
SEALANT OVER BOND BREAKER
CONTINUOUS ACROSS HEAD & JAMB
APPLY TWO COATS OF STO
FLEXYL WATERPROFFING TO
ALL REBATES OVER BASECOAT
50mm MIN.DOWN WALL
STOARMAT MIRAL
PLASTER SYSTEM
TIMBER DOOR JOINERY
PROFILES AS PER NZS 3610
AIRSEAL ON PEF ROD GAP
7.5-8mm APPROX & PACKER
ALU.EQUAL ANGLE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
TIMBER DOOR JOINERY - JAMB DETAIL
CB 407
2014
PROVIDE SEPARATION (ROOFUNDERLAY) UNDER METAL CAPPING
OVER 9mm H3 PLY ON DPCMETAL CAPPING WITH 5°MIN.FALL TO PARAPET -
MASONRY FIXINGS
5°
SELECTED CONC.BLOCKSERIES (shown 20 series
conc.block)
SCALE 1:5
STOARMAT MIRALPLASTER SYSTEM
NOTE: CUT BLOCK TO SUIT OR BASECOAT PLASTERTO A FALL APPROX.18mm FROM FRONT EDGE BEFOREINSTALLING PLYWOOD ON DPC. ALTERNATIVELY USEH3.1 TIMBER PLATE, MAINTAINING FLASHING COVEROVER CONC.BLOCK OF 50mm MIN.
50
50
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
PARAPET/METAL FLASHING DETAIL
CB 500
2014
SCALE 1:5
NOTE: CUT BLOCKS TO SUIT or BASECOAT PLASTER TOA FALL 10° MIN.FOR STOCLEAR COATING SYSTEM -REFER TO DRAWING DETAIL CB 502
10°
STOFLEXYL MEMBRANEUNDER MESH COAT TO TOP &
SIDES, 75mm DOWNTURNOVER LEVELITE BASE COAT
SELECTED CONC.BLOCK SERIES(shown 20 series conc.block)
STOARMAT MIRALPLASTER SYSTEM
75
75
CUT CONC.BLOCK TO FORMREQUIRED SLOPE OF 10° MIN.
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
PLASTERED PARAPET/BALUSTRADE DETAIL
CB 501
2014
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
SCALE 1:5
15
5
STOFLEXYL MESHED
WATERPROOFING
PAINTED, CLEAR COATED
or PLASTERED FINISH
MORTAR BED 15mm -
5mm FALL TO
INTERIOR SIDE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
UNCOATED,PAINTED CLEAR COATED or PLASTERED
CB 502
2014
ROOF SCREED TO AMIN FALL1.5°
CONCRETEROOF SLAB
SCALE 1:5
10°
STOFLEXYL MEMBRANE UNDER MESHCOAT TO TOP & SIDES, 75mm DOWNTURN
OVER LEVELITE BASE COATSELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
STOARMAT MIRALPLASTER SYSTEM
CUT CONCRETE BLOCK TO FORMREQUIRED SLOPE OF 10° MIN.
75
75
70
INSULATION AS PERNZBC - H1
SELECTED ROOFMEMBRANE 15
0
SELECTED ROOF MEMBRANEUPSTAND150mm MIN.
STO STICK ON CONNECTOR OR STOuPVC FINISHING EDGE & MS
SEALANT AT FLASHING
METAL OVERFLASHING SEALED INTOWALL CHASE (20mm x 10mm) & FIXED
WITH A MASONRY FIXINGS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
PARAPET/ROOF/WALL DETAIL
CB 503
2014
SCALE 1:20
OVERLAY OF STOFLEXYL MESHEDWATERPROOFING TO TOP & SIDES- 75mm DOWNTURN OVER BASECOAT75
NOTE:1. ALL ADJACENT WALLS ARE TO BE STRUCTURALLY TIED WITH
STEEL REINFORCEMENT.2. BALUSTRADES TO HAVE 10° MIN.FALL TO TOP3. ALL BALUSTRADES/PARAPETS & WALL CAPS TO HAVE STOFLEXYL
MESHED WATERPROOFING4. STO FLEXYL MESHED WATERPROOFING MEMBRANE HAS BEEN
TESTED BY BRANZ TO AS/NZS4858 - AS REQUIRED BY E2/AS1 &CCANZ CP01:2014
LEVELLITE BASECOAT
SELECTED CONC.BLOCK SERIES(shown 20 series conc.block)
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
STOFLEXYL WATERPROOFING MEMBRANE
CB 504
2014
SCALE 1:5
50
mm
MIN
.CO
VE
R
60mm
H3.1 PRE PRIMED &PAINTED
FASCIA/BARGEBOARD
SOFFIT LINING
PRE FINISHED METALROOFING OVER ROOFUNDERLAY
INSULATION ASPER NZBC - H1
M12 BOLT FIXING
MS SEALANT 6-8mm,WATERPROOF
CONC.BLOCK BEFOREINSTALLING SOFFIT
SOFFIT FRAMING
20 SERIES CONCRETEMASONRY WALL
STOARMAT MIRALPLASTER SYSTEM TO
TOP OF WALL
NOTE: EAVE FLASHING REQUIRED WHERE• ROOF SLOPE LESS THAN OR EQUAL TO 10°• SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm• WIND ZONES ARE VERY HIGH or EXTRA HIGH
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
EAVES WITH OVERHANG
CB 600
2014
SCALE 1:5
NOTE: EAVE FLASHING REQUIRED WHERE• ROOF SLOPE LESS THAN OR EQUAL TO 10°• SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm• WIND ZONES ARE VERY HIGH or EXTRA HIGH, MS
SEALANT REQUIRED
50 m
m125
35
MIN
.CO
VE
R
INSULATION AS PERNZBC - H1
20 SERIES CONCRETEMASONRY WALL
STOARMAT MIRALPLASTER SYSTEM TO
TOP OF WALL
H3.1 PRE PRIMED &PAINTED FASCIA/BARGE
BOARD
M12 BOLT FIXING
PRE FINISHED METALROOFING OVER ROOFUNDERLAY
PURLIN - REFERNZS 3604
COMPLIANT EAVEFLASHING/E2/AS1
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
EAVES WITH NO OVERHANG
CB 601
2014
SCALE 1:5
PRE FINISHED METAL
FLASHING
LAP - REFER NZBC, TABLE 7
E2/AS1
H3.1 PRE PRIMED &
PAINTED FASCIA/BARGE
BOARD
PRE FINISHED METAL
ROOFING OVER ROOF
UNDERLAY
RAFTER - REFER NZS 3604
FOR SIZE
PURLIN - REFER NZS 3604
SOFFIT LINING
50/90
MIN.2 x crests
INSULATION AS
PER NZBC - H1
20 SERIES CONCRETE
MASONRY WALL
STOARMAT MIRAL
PLASTER SYSTEM
RAKING WALL
PLATE ON DPC
BOLT FIXING
FLYING RAFTER
OUTRIGGER
STO 6mm FINISHING EDGE
20 x 20mm SCOTIA BEAD
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
BARGE WITH OVERHANG
CB 602
2014
SCALE 1:5
RAFTER - REFER NZS
3604 FOR SIZE
PURLIN - REFER
NZS 3604
INSULATION/STAPPING
AND LINING
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
STOFLEXYL MESHED
WATERPROOFING 75mm
MIN.DOWNTURN OVER BASECOAT
METAL OVER-FLASHING TO BE
CHASED AND SEALED INTO
WALL WITH MS SEALANT
35
75
STO uPVC FINISHING EDGE TO
PLASTER AND MS SEALANT AT
FLASHING JUNCTION
110m
m U
pstand for flashing
PROFILED ROOF FLASHING &
UNDERLAY TO RUN UP BENEATH
OVER-FLASHING AND TO BE
MECHANICALLY FIXED TO WALL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
ROOF TO CONC.BLOCK GABLE END
CB 603
2014
SCALE 1:10
SELECTED FIBRECEMENT SOFFIT LINING
STOARMAT MIRALPLASTER SYSTEM
NOTE:• MAX.ANGLE OF SOFFIT RESTRICTED TO
BETWEEN 91° - 115°• SOFFITS ARE FIXED AFTER PLASTERING
BRUSH STOFLEXYLWATERPROOFING TO CONC.BLOCK
- 50mm MIN. PAST SOFFIT
PRE FINISHED METALROOFING OVER ROOFUNDERLAY
INSULATION/STAPPINGAND LINING
20 SERIES CONCRETEMASONRY WALL
50
6mm MAX.GAP WITH MS SEALANTor STO JOINT SEAL TAPE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
RAKING SOFFIT (REVERSED)
CB 604
2014
SCALE 1:5
NOTE: INSTALL DIVERTER FLASHING
AT ROOF/GUTTER JUNCTION
METAL OVER-FLASHING TO BE CHASED
AND SEALED INTO WALL WITH MS SEALANT
SECURED WITH MASONRY FIXINGS
Refer E2/AS1 table 7
TIMBER ROOF STRUCTURE
STOARMAT MIRAL
PLASTER SYSTEM
35
75
STO uPVC FINISHING EDGE TO
PLASTER WITH MS SEALANT
110m
m U
pstand for flashing
PROFILED ROOF APRON
FLASHING & ROOF UNDERLAY TO
RUN UP BEHIND FLASHING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
GABLE END/ROOF JUNCTION
CB 700
2014
SCALE 1:5
R
e
fe
r E
2
/A
S
1
T
a
b
le
7
TIMBER ROOF STRUCTURE
METAL OVER-FLASHING TO BE CHASED
AND SEALED INTO WALL WITH MS SEALANT
SECURED WITH MASONRY FIXINGS
35
75
STO uPVC FINISHING EDGE TO
PLASTER WITH MS SEALNT
110m
m U
pstand for flashing
PROFILED ROOF, APRON
FLASHING & ROOF UNDERLAY TO
RUN UP BEHIND FLASHING
NOTE:ENSURE APRON FLASHING IS OVER
FLASHED AT BOTH ENDS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
APRON FLASHING
CB 701
2014
SCALE 1:5
35
75
110m
m U
pstand for flashing
20m
m
80mm 80mm
TIMBER ROOF
STRUCTURE
METAL OVER-FLASHING TO BE CHASED
AND SEALED INTO WALL WITH MS SEALANT
SECURED WITH MASONRY FIXINGS
STOARMAT MIRAL
PLASTER SYSTEM
STO uPVC FINISHING EDGE TO
PLASTER WITH MS SEALANT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
PARALLEL ROOF/HIDDEN GUTTER
CB 702
2014
SCALE 1:5
SELECTED MEMBRANE FINISH OVER H3"C" FACED
PLYWOOD LAID TO A 1:30MIN.FALL GLUE & SCREW
TO TIMBER FRAMING, ALL EDGES SUPPORTED
MIN. 5mm RADIUS
TO PLYWOOD
50mm MIN.LAP -
REFER E2/AS1
S/S ANGLE
PRE FINISHED
METAL SPOUTING
AND BRACKETS
H3.1 PRE PRIMED & PAINTED
FASCIA/BARDGE BOARD MS
SEALANT ON STO SEAL TAPE
50
INSULATION AS PER
NZBC - H1
20 SERIES CONCRETE
MASONRY WALL
STOARMAT MIRAL
PLASTER SYSTEM
50
CO
VE
R
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
FACE FIXED FASCIA/MEMBRANE ROOF
CB 703
2014
SCALE 1:5
INSULATION AS PER NZBC
- H1
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
SELECTED HORIZONTAL
TIMBER WEATHERBOARDS
OVER 20mm DRAINED CAVITY
WALL UNDERLAY
NOMINAL H3.1 TIMBER
BATTEN
E2/AS1 COMPLIANT BACK
FLASHING WITH MS SEALANT
50m
m M
IN
.C
OV
ER
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
EXTERNAL CORNER
CB 800
2014
SCALE 1:5
50m
m M
IN
.C
OV
ER
NOMINAL H3.1
TIMBER BATTEN
STO uPVC FINISHING EDGE
WITH MS SEALANT
E2/AS1 COMPLIANT
FLASHING IN
CONC.BLOCK CHASE
SELECTED HORIZONTAL
TIMBER WEATHERBOARDS
OVER 20mm DRAINED CAVITY
INSULATION AS PER
NZBC - H1
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
INTERNAL CORNER
CB 801
2014
SCALE 1:5
INSULATION/STAPPING
AND LINING
WALL PLATE ON
DPC
CAVITY CLOSURE
SELECTED FLOORING
JOISTS - REFER
NZS3604:2011 FOR SIZE
STOARMAT MIRAL PLASTER
SYSTEM WITH STO uPVC
FINISHING EDGE
15
50
WALL UNDERLAY
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
SELECTED HORIZONTAL
TIMBER
WEATHERBOARDS OVER
20mm DRAINED CAVITY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
HORIZONTAL JUNCTION/WEATHERBOARD
CB 802
2014
SCALE 1:5
MS SEALANT OVER
PEF ROD
INSULATION AS
PER NZBC - H1
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
NOMINAL H3.1 TIMBER
BATTEN
PROFILED FOAM CLOSURE
STRIP UNDER CLADDING
HORIZONTAL PROFILED METAL
WALL CLADDING
FLASHING (SPECIFY COATING)
E2/AS1 COMPLIANT FLASHING
REBATED IN CHASE CUT INTO
CONCRETE BLOCK
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
EXTERNAL CORNER HORIZ.PROFILED METAL
CB 850
2014
SCALE 1:5
27m
m M
IN
.C
OV
ER
INSULATION AS PER
NZBC - H1
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
DPC
NOMINAL H3.1 TIMBER
BATTEN
SELECTED INTERNAL
LININGS
E2/AS1 COMPLIANT BACK
FLASHING CHASED INTO
CONC.BLOCK
MS SEALANT OVER PEF ROD
PROFILED FOAM CLOSURE
STRIP UNDER CLADDING
HORIZONTAL PROFILED METAL
WALL CLADDING
PURPOSE MADE FLASHING
(SPECIFY COATING)
STOARMAT MIRAL SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
INTERNAL CORNER HORIZ.PROFILE METAL
CB 851
2014
SCALE 1:5
INSULATION AS PER
NZBC - H1
WALL PLATE ON
DPC
HORIZONTAL PROFILED
METAL CLADDING
CLOSE CAVITY VENTED
E2/AS1 COMPLIANT
FLASHING
SELECTED
FLOORING
JOISTS - REFER
NZS3604 FOR SIZE
CEILING
BATTENS
15
50
WALL UNDERLAY
20mm DRAINED &
VENTED CAVITY
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
STOARMAT MIRAL PLASTER
SYSTEM WITH STO uPVC
FINISHING EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
HORIZONTAL JUNCTION/HORIZ.PROFILED METAL
CB 852
2014
SCALE 1:5
MS SEALANT
OVER PEF ROD
INSULATION AS PER
NZBC - H1
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
DPC
E2/AS1 COMPLIANT BACK
FLASHING
20
VERTICAL PROFILED
METAL WALL CLADDING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
EXTERNAL CORNER VERTICAL.PROFILED METAL
CB 853
2014
SCALE 1:5
INSULATION AS PER
NZBC - H1
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
E2/AS1 COMPLIANT BACK
FLASHING CHASED INTO
CONC.BLOCK50
SELECTED INTERNAL
LININGS
MS SEALANT JOINT OVER
PEF ROD
VERTICAL PROFILED METAL WALL
CLADDING
STOARMAT MIRAL PLASTER
SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
INTERNAL CORNER VERTICAL PROFILE METAL
CB 854
2014
SCALE 1:5
INSULATION AS
PER NZBC - H1
WALL PLATE ON
DPC
VERTICAL PROFILED
METAL CLADDING
SELECTED
FLOORING
JOISTS - REFER
NZS3604 FOR SIZE
CEILING
BATTENS
STOARMAT MIRAL
PLASTER SYSTEM WITH
STO uPVC FINISHING EDGE
50
WALL UNDERLAY
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
3.5mm VENTILATION GAP,
NON VENTED CLOSER
FLASHING
6
3.5
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETEBLOCK
STO CONCRETE BLOCK
HORIZ.JUNCTION/VERTICAL PROFILED METAL
CB 855
2014