sto concrete block drawing · pdf filesto concrete block alu.joinery - jamb detail cb 401 sto...

51
Drawing Description Drawing No. Drawing Register CB 001 - 002 Introduction Series 000 Sto Concrete Block Construction & Detailing CB 003 Sto Concrete Block Construction & Detailing CB 004 Sto Concrete Block Construction & Detailing CB 005 Sto Concrete Block Plaster System CB 006 Block Layout Series 100 Sto Concrete Block Stoarmat Miral System - Isometric CB 100 Foundation Series 200 Sto Concrete Block Rebated Slab-on-Ground CB 200 Sto Concrete Block Non-Rebated Slab-on-Ground CB 201 Sto Concrete Block Strip Footing Detail CB 202 Sto Concrete Block Tanking to Plaster Transition CB 203 Walls Series 300 Sto Concrete Block Vertical Control Joint CB 300 Sto Concrete Block Stair Waterproofing Detail CB 301 Sto Concrete Block Inter-Storey Slab Detail CB 302 Wall Penetrations & Fittings Series 350 Sto Concrete Block Pipe Penetration (up to 150mm Ø) Detail CB 350 Sto Concrete Block Meterbox CB 351 Sto Concrete Block Fan Vent Detail CB 352 Sto Concrete Block Architectural Profile CB 353 Sto Concrete Block Handrail CB 354 Sto Concrete Block RWH/Scupper Opening CB 355 Joinery Series 400 Sto Concrete Block Alu.Joinery - Head & Sill Detail CB 400 Sto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto Concrete Block Alu.Entry Door Head & Threshold Detail CB 402 Sto Concrete Block Alu.Entry Door Jamb Detail CB 403 Sto Concrete Block Timber Joinery - Head & Sill Detail CB 404 Sto Concrete Block Timber Joinery - Jamb Detail CB 405 Sto Concrete Block Timber Entry Door Head & Threshold Detail CB 406 Sto Concrete Block Timber Entry Door Jamb Detail CB 407 Parapets, Balustrades, Decks Series 500 Sto Concrete Block Parapet/Metal Flashing Detail CB 500 Sto Concrete Block Plastered Parapet/Balustrade Detail CB 501 Sto Concrete Block Uncoated, Painted, Clear Coated or Plastered Parapet Detail CB 502 Sto Concrete Block Parapet/Roof/Wall Detail CB 503 Sto Concrete Block StoFlexyl Waterproofing Membrane - Isometric CB 504 THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES. ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS. THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALL WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE. STO DRAWING REGISTER PAGE 1 OF 2 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. STO CONCRETE BLOCK STO CONCRETE BLOCK DRAWING REGISTER CB 001 2014

Upload: vuongngoc

Post on 06-Feb-2018

225 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

Drawing Description Drawing No.

Drawing Register CB 001 - 002

Introduction Series 000Sto Concrete Block Construction & Detailing CB 003Sto Concrete Block Construction & Detailing CB 004Sto Concrete Block Construction & Detailing CB 005Sto Concrete Block Plaster System CB 006

Block Layout Series 100Sto Concrete Block Stoarmat Miral System - Isometric CB 100

Foundation Series 200Sto Concrete Block Rebated Slab-on-Ground CB 200Sto Concrete Block Non-Rebated Slab-on-Ground CB 201Sto Concrete Block Strip Footing Detail CB 202Sto Concrete Block Tanking to Plaster Transition CB 203 Walls Series 300Sto Concrete Block Vertical Control Joint CB 300Sto Concrete Block Stair Waterproofing Detail CB 301 Sto Concrete Block Inter-Storey Slab Detail CB 302

Wall Penetrations & Fittings Series 350Sto Concrete Block Pipe Penetration (up to 150mm Ø) Detail CB 350Sto Concrete Block Meterbox CB 351Sto Concrete Block Fan Vent Detail CB 352Sto Concrete Block Architectural Profile CB 353Sto Concrete Block Handrail CB 354Sto Concrete Block RWH/Scupper Opening CB 355

Joinery Series 400Sto Concrete Block Alu.Joinery - Head & Sill Detail CB 400Sto Concrete Block Alu.Joinery - Jamb Detail CB 401Sto Concrete Block Alu.Entry Door Head & Threshold Detail CB 402Sto Concrete Block Alu.Entry Door Jamb Detail CB 403Sto Concrete Block Timber Joinery - Head & Sill Detail CB 404Sto Concrete Block Timber Joinery - Jamb Detail CB 405Sto Concrete Block Timber Entry Door Head & Threshold Detail CB 406Sto Concrete Block Timber Entry Door Jamb Detail CB 407

Parapets, Balustrades, Decks Series 500Sto Concrete Block Parapet/Metal Flashing Detail CB 500Sto Concrete Block Plastered Parapet/Balustrade Detail CB 501Sto Concrete Block Uncoated, Painted, Clear Coated or Plastered Parapet Detail CB 502Sto Concrete Block Parapet/Roof/Wall Detail CB 503Sto Concrete Block StoFlexyl Waterproofing Membrane - Isometric CB 504

THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE ISRESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALLWATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.

STO DRAWING REGISTER

PAGE 1 OF 2

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

DRAWING REGISTER

CB 001

2014

Page 2: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

Drawing Description Drawing No.

Soffit Series 600Sto Concrete Block Eaves with Overhang CB 600

Sto Concrete Block Eaves without Overhang CB 601

Sto Concrete Block Barge with Overhang CB 602

Sto Concrete Block Roof to Conc.Block Gable End CB 603

Sto Concrete Block Raking Soffit (Reversed) CB 604

Roof Series 700Sto Concrete Block Gable End/Roof Junction CB 700

Sto Concrete Block Apron Flashing CB 701

Sto Concrete Block Parallel Roof/Hidden Gutter CB 702

Sto Concrete Block Face Fixed Fascia/Membrane Roof CB 703

Dissimilar Material

Bevel-Back Weatherboard Series 800Sto Concrete Block Ext.Corner CB 800

Sto Concrete Block Int.Corner CB 801

Sto Concrete Block Horizontal Junction CB 802

Brick Series 810 series not issued

Fibre Cement Sheet Series 820 series not issued

Manufactured Stone - Schist & Natural Stone Series 840 series not issued

Profile Metal Series 850Sto Concrete Block Ext.Cnr Horiz.Profiled Metal CB 850

Sto Concrete Block Int.Cnr Horiz.Profiled Metal CB 851

Sto Concrete Block Horizontal Junction Horiz.Profiled Metal CB 852

Sto Concrete Block External Corner Vertical Profiled Metal CB 853

Sto Concrete Block Internal Corner Vertical Profiled Metal CB 854

Sto Concrete Block Horiz.Junction Vertical Profiled Metal CB 855

Stotherm Panel EIPS 860 series not issued

DISSIMILAR JOINERY Series 870 series not issued

STO DRAWING REGISTER

THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.

ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.

THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS

RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALL

WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.

PAGE 2 OF 2

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

DRAWING REGISTER

CB 002

2014

Page 3: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

ENSURE CONC.BLOCK WALLS ARE

SUPPORTED DURING CONSTRUCTION

45mm MIN.REBATE IS RECOMMENDED

A NON-REBATED FOUNDATION

REQUIRES 100mm STO FLEXYL

MESHED WATERPROOFING STRIP

CENTERED OVER FLOOR JOINT

NOTE:

1. MAIN CONTRACTOR IS TO ENSURE SEPARATE WALLS, STAIRS or DISSIMILAR

MATERIAL AGAINST BLOCKWORK ARE WATERPROOFED AS NECESSARY TO

FORM A WATERTIGHT CONNECTION WITH THE STO PLASTER SYSTEM2. IT IS CRITICAL IN PARTIALLY FILLED BLOCKS THAT JOINTS ARE TOOLED FOR

EARTHQUAKE RESISTANCE

3. MASONRY CONCRETE BLOCKS as per NZS4210 / 4229 &4230 or SPECIFIC

ENGINEER DESIGN

4. ALLOW ADEQUATE TIME FOR BLOCKS TO DRY/STABILISE BEFORE PLASTERING.

IN NORMAL DRYING CONDITIONS 4-8 WEEKS

5. CONTROL JOINTS - REFER ENGINEERS SPECIFICATION, BLOCK

MANUFACTURERS RECOMMENDATION or NZS4229

SILL BLOCKS SHOULD BE FILLED.

CREATE OPENING TO ENABLE BLOCK

MORTAR TO FLOW THROUGH. REMOVE

PROJECTING SILL FOR A FLUSH FINISH

MORTAR = 10mm +/- 3mm

ALLOW MORTAR JOINTS TO BE

TOOL COMPRESSED

SCALE 1:20

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

CONSTRUCTION & DETAILING

CB 003

2014

Page 4: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

CONCRETE BLOCK CONSTRUCTION & DETAILING

ResponsibilityAll work in this section shall be the responsibility of the Main Contractor . All concrete block

construction must be in accordance with the project drawings, specifications and block

manufactures technical data. The Main Contractor is to ensure they are fully conversant with all Stostandard installation and fixing details (Sto ACAD details www.sto.co.nz) and their responsibilities

before the block works commences. The Main Contractor is also responsible for all liaison with the

various sub contractors to ensure that all items or elements affecting the Sto Plaster System are

correctly detailed before installing the StoArmat Miral Plaster System.

Concrete BlocksThe concrete block installation including reinforcement and concrete infill shall be made in strict

accordance with the project drawings, specifications and the block manufactures technical

documentation. In particular the blocks shall be laid true in both vertical and horizontal planes with all

joinery and service openings correctly formed and waterproofed in accordance with Sto details.Control joints must be installed as per the projects structural drawings or manufactures details to

manage shrinkage and structural stress. The ground floor slab to block junction should be rebated to

provide waterproofing and inter-storey floors should be poured within the block structure leaving the

outer block shell to continue to avoid cracking. At least 28 days should be allowed after concrete

placement - as per AS/NZS 2311:2000 for curing and stabilization to take place before commencing

the StoArmat Miral Plaster System. All maximum tolerances shall be in strict accordance with

NZS4210:2001 2.7.1.4, Table 2.2 IE: no more than 3mm surface alignment deviation over a 1200mm

radius. The concrete blocks shall be clean, dry and free of all surface contaminants before plastering

and the Main Contractor is to ensure that any area or details adjacent to the Sto Plaster System have

been adequately waterproofed or flashed to avoid any water migration behind the plaster system.

Construction Block Construction

• A rebate is recommended in foundations for residential projects unless an exterior insulation

system is detailed.

• Joinery openings are to be formed using rebated blocks & sill blocks (cut sill flush as required).• Blocks should be covered on site and laid dry.

• Vertical control joints are placed at 6.0M max.centres - refer project documentation and NZS4229

for placement and detailing.

• Mortar to be 12.5MPa min.tool smooth and compressed as per NZS4210

• Manufacturers bagged mortar is recommended to meet the specifications

• Mortar to full depth of webbing up to 20MM thick in first course and then 10MM +/- 3mm

• Washout ports required to remove mortar droppings from foundation

• Ensure there is no impediment to grout flow, remove ends or biscuits to prevent air pockets

• Stack bonded, column blocks and insulation block voids may need to be grouted by the block

layer during laying process to ensure a solid fill is achieved

• Blocks should be filled in 1.2 lifts and mechanically vibrated to avoid air voids and subsequence

efflorescence

• Sill block should be filled by leaving one sill block out to avoid air entrapment

• Remove any grout slurry from block faces before it sets

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

CONSTRUCTION & DETAILING

CB 004

2014

Page 5: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

CONCRETE BLOCK CONSTRUCTION & DETAILING......cont.

Construction Block Construction

• Drying times vary according to block thickness, grout and weather. A min.28days is

required for settlement & curing - the blocks must be completely dry before coating

• Where occupied walls are back filled a 50 year tanking membrane is required.

• Always waterproof blocks behind or adjacent to any overlays or abutments such as

concrete staircases, separate adjoining garden walls, soffits, porches, posts etc.

• Exposed tops of walls require waterproofing and should be finished with block caps

Exterior Insulation - refer to Sto Concrete Block Insulation Details

NZBC Acceptable Solution H1/AS1 or NZBC Verification Method H1/VM1 can be used for housing,

communal residential, communal non-residential and commercial buildings. For buildings with a

glazing area of 30% or less of the total wall area, the minimum wall R-values required for solid

construction are:

Climate Zone 1 (Nth Coromandel) - R0.8 (option 1a and 1b)

Climate Zone 2 Nth Island, Sth Coromandel excluding the Central Plateau - R1.0 (option 2a) or R0.9

(option 2b)

Climate Zone 3 Sth Island and Central Plateau) - R1.2 (option 3a) or R1.0 (option 3b)

Refer to the BRANZ House Insulation Guide Third Edition for further information and construction

R-values for concrete block construction with External Insulation.

Interior InsulationGenerally involves 90mm framing inside and installing insulation to meet 1.9 or 2.0 R-Value

Note: H1 Insulation - Internally insulated masonry walls must meet the timber insulation code

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

CONSTRUCTION & DETAILING

CB 005

2014

Page 6: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

STO CONCRETE BLOCK PLASTER SYSTEM

StoArmat Reinforced Plaster System

To combat fractures and stress that can occur in concrete block construction during the curing and

settling process. The StoFlexyl waterproofing membrane is to ensure openings, junctions,

terminations and overlays are waterproofed.

SS202 STOARMAT MIRAL PLASTER SYSTEM BRANZ APPRAISAL CERTIFICATE No.515

INCORPORATING:

1. Stoflexyl Waterproofing 18Kg pail plus cement evaluated by BRANZ to meet AS/NZS4858

waterproofing membrane requirements as required by NZBC E2/AS1

2. Levellite Base Plaster 20Kg bag mineral fibre reinforced based plaster with EPS bead for levelling

and straightening walls. Can be machine applied

3. StoArmat Classic Plaster 23Kg pail European fibre reinforced non-cement based crack resistant

plaster used with European mesh as a reinforcement plaster

4. Stolit Coloured Finishing Render in 25Kg Pail

Stolit K - 1.0mm Coloured Float Finish Render

1.5mm Coloured Float Finish Render

2.0mm Coloured Float Finish Render

3.0mm Coloured Float Finish Render

Stolit - MP Fine Sponge or Adobe Coloured Finishing Render

MP Natural Sponge or Adobe Coloured Finishing Render

Milano Smooth or Adobe Coloured Finishing Render

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

PLASTER SYSTEM

CB 006

2014

Page 7: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:20

STOARMAT MIRAL PLASTERSYSTEM - SS202

STOLIT K COLOURED FINISH RENDER

1.0, 1.5, 2.0 & 3.0mm FLOAT FINISH.

STOLIT MP COLOURED FINISH RENDER

MP, MP NATURAL & MILANO FINE FINISH

BASECOAT: LEVELLITE 6/8mm

PLASTER

REINFORCEMENT: STOARMAT

CLASSIC PLASTER

PLUS: STO EUROPEAN MESH

FINISHING RENDER: STOLIT K

& MP RANGE

SKIM COAT: STOARMAT

CLASSIC PLASTER

COATING/STO COLOR:

:MAXICRYL MATT FACADE PAINT

:LASTIC SATIN FACADE PAINT

:LOTUSAN MINERAL RESIN PAINT

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

STOARMAT MIRAL PLASTER SYSTEM - ISOMETRIC

CB 100

2014

Page 8: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

CONCRETE SLAB/REINFORCING

AS PER NZS 4229 & 4210 ORENGINEER SPECIFIC DESIGN

INSULATION as per NZBC - H1

CONCRETE MASONRY WALL

50

DPM

50

100m

m

150

SCALE 1:5

DPC

SLAB

INSULATION

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

REBATED SLAB-ON-GROUND

CB 200

2014

Page 9: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

CONCRETE SLAB/REINFORCING AS PER

NZS 4229 & 4210 OR ENGINEER SPECIFIC

DESIGN

STO FLEXYL

WATERPROOFING

SHALL EXTEND

ABOVE GROUND BY

AT LEAST 150mm AND

IF DPM IS APPLIED

TO THE EXTERNAL

FACE OF FOOTING IT

SHALL OVERLAP BY

AT LEAST 50mm

INSULATION as per NZBC - H1

CONCRETE

MASONRY WALL

STOARMAT MIRAL

PLASTER SYSTEM

100mm STOFLEXYL

MESH OVER SLAB TO

BLOCK JUNCTION

STOFLEXYL - BRUSH

SHEETS & FOUNDATION

ADHESIVE MORTAR TO

FACE AND MECHANICAL

FIX @ 600mm CTRS

ABOVE GROUND

SCABBLE SLAB SURFACE

FOR BLOCK BOND

DPM REQUIRED

FOR POORLY

DRAINED SITES

100m

m

paved

150m

m

unpaved

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

NON-REBATED SLAB-ON-GROUND

CB 201

2014

Page 10: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

NOTE:REFER TO NZS 4229 or

SPECIFIC DESIGN FOR

DIMENSION, REINFORCING

AND GROUND CLEARANCES

SCALE 1:10

see note

see note

150

CONCRETE MASONRY

WALL

INSULATION as per

NZBC - H1

STOFLEXYL WATERPROOFING

SHALL EXTEND ABOVE GROUND

BY AT LEAST 150mm AND IF DPMIS APPLIED TO THE EXTERNAL

FACE OF FOOTING IT SHALL

OVERLAP BY AT LEAST 50mm

50

G.L

STOARMAT MIRAL

PLASTER SYSTEM

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

STRIP FOOTING DETAIL

CB 202

2014

Page 11: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

STOARMAT MIRAL

PLASTER SYSTEM

TANKING SEALANT

COMPRESSION BAR

MECHANICALLY FIXED TO

CONC.BLOCK

GRANDULAR FILL

RECOMMENDED

SELECTED BITUMOUS

PEEL & STICK TANKING

MEMBRANE

WITH PROTECTION

MATERIAL

TRANSITION APPROX.100mm

BELOW GROUND

NOTE:REFER TO NZS 4229 or

SPECIFIC DESIGN FOR

DIMENSION & REINFORCING

150

100

STOFLEXYL MESHED

WATERPROOFING FROM

150mm ABOVE GROUND

AND DOWN OVER

COMPRESSION BAR

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

TANKING TO PLASTER TRANSITION

CB 203

2014

Page 12: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:20

VERTICAL CONTROL JOINTS AT BLOCK

CONTROL JOINTS - NORMALLY @6.0M

CENTERS or AS PER PROJECT DRAWINGS

BASECOAT: LEVELLITE 6/8mm

REINFORCEMENT: STOARMAT

CLASSIC

STO 8 mm uPVC JOINT IN

STOARMAT MESH COAT

FINISHING RENDER: STOLIT K

& MP RANGE

NOTE:WHEN FITTING THE STO CONTROL JOINT, PULL TAB 75mm OUT TO ENSURE

EASIER REMOVAL. BED JOINT IN STOARMAT CLASSIC MESH COAT. THE

FINISHED JOINT MUST BE COATED FOR NEGATIVE DETAIL or FILLED WITH

MS SEALANT. REMOVE TABS AS SOON AS JOINT IS SET TO AVOID

CRACKING

BLOCK CONTROL JOINT

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

VERTICAL CONTROL JOINT

CB 300

2014

Page 13: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

STOFLEXYL WATERPROOFING 150mm

MIN.ABOVE & BELOW STAIRS WITH 50mm

MIN.UNDER PLASTERED STAIRS or TILE

MEMBRANE

INSULATION AS PER

NZBC - H1

CONCRETE MASONRY

WALL (20 Series shown)

APPLY STOFLEXYL MESHED BAND ON

CONC.BLOCKS 150mm MIN. ABOVE AND 150mm

BELOW STAIRS BEFORE BOXING - APPLY

STOFLEXYL MESH, 50mm MIN.ONTO STAIRS

ONCE CONCRETE HAS CURED BEFORE

PLASTERING OR APPLYING TILE MEMBRANE

10

0

50mm

STOFLEXYL WATERPROOFING MEMBRANE

• WALL CAPS, PARAPETS, BALUSTRADE TOPS

• JOINERY OPENINGS

• TIMBER OVERLAYS & SOFFITS

• STAIRS

• ADJACENT GARDEN WALLS

• FOUNDATIONS

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

STAIR WATERPROOFING DETAIL

CB 301

2014

Page 14: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

INTER-STOREY FLOOR

SLAB - REINFORCING NOTSHOWN FOR CLARITY

STOARMAT MIRAL

PLASTER SYSTEM

STOFLEXYL MESH COAT

OVER FLOOR JUNCTION IF

FLOOR SLAB PENETRATES

EXT.CONC.BLOCK

INSULATION AS PER

NZBC - H1

CONCRETE MASONRY

WALL (20 Series shown)

DPC

SCALE 1:10

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

INTER-STOREY SLAB DETAIL

CB 302

2014

Page 15: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

5° MIN.SLOPE TO OUTSIDE

INTERIOR EXTERIOR

8/10mm SEALANT BEAD ON PEFROD BETWEEN PIPE AND PLASTER

PIPE OR OTHER PENETRATIONSLOPED DOWNWARD - TOWARD THEOUTSIDE

INSULATION AS PER NZBC - H1

CONCRETE MASONRY WALL

SECURE PIPE, APPLY SEALANTPLASTER AND REAPPLY SEALANT ONMESH COAT BEFORE FINISHING

SCALE 1:5

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

PIPE PENETRATION DETAIL (up to150mm)

CB 350

2014

Page 16: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

METER BOX AT SILL

METER BOX AT HEAD

PREPARE REBATES, AND APPLY

TWO (2) COATS OF STOFLEXYL

WATERPROOFING BEFORE

APPLYING STOARMAT MIRAL

PLASTER SYSTEM. LEAVE 10mm

SEALANT JOINT

STOARMAT MIRAL PLASTER

SYSTEM

MS SEALANT OVER STO JOINT

SEAL TAPE TO PERIMETER OF

METERBOX

PREPARE REBATES, APPLY TWO (2)

COATS OF STOFLEXYL

WATERPROOFING BEFORE APPLYING

STOARMAT MIRAL SYSTEM. LEAVE

10mm SEALANT JOINT

APPLY STOARMAT MIRAL PLASTER

SYSTEM WITH STO uPVC DRIP EDGE

AT HEAD

MS SEALANT OVER STO

JOINT SEAL TAPE

THICKEN BASECOAT ON REBATES TO

ACHIEVE A 6-8mm FINISHING GAP

BEFORE SEALING

SCALE 1:5

POLYSTYRENE

INSULATION TO SUIT

PROVIDE

AIRSEAL

PROVIDE

AIRSEAL

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

METER BOX

CB 351

2014

Page 17: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SLO

PE

TO

OU

TS

IDE

LEAVE 40mm DRAINAGE

GAP IN MIDDLE

INSULATION AS PER NZBC - H1

CONCRETE MASONRY WALL

MS SEALANT TO PERIMETER

SCALE 1:5

STOARMAT MIRAL PLASTER

SYSTEM

FA

N V

EN

T C

OV

ER

MS SEALANT AT PIPE

JUNCTION (FIX FAN COVER TOFLEXIBLE PIPE AS PERMANUFACTURERSINSTRUCTION) USE STO JOINT

SEAL TAPE TO SEAL TO

CONCRETE BLOCK

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

FAN VENT DETAIL

CB 352

2014

Page 18: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

ADHESIVE ADHERE

ARCHITECTURAL PROFILES

AND USE STOTHERM FIXINGSAS NECESSARY

INSULATION AS PER NZBC - H1

CONCRETE MASONRY WALL

PREMESHED ARCHITECTURAL

PROFILE OVER STOARMAT/MESH

COAT

STOARMAT MIRAL PLASTER

SYSTEM

MESH COAT UNDER PROFILE

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

ARCHITECURAL PROFILE

CB 353

2014

Page 19: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

ROOF SCREEDTO A FALL -

MIN FALL1.5°

CONCRETEROOF SLAB

SCALE 1:5

STOFLEXYL MESHEDWATERPROOFING WITH75mm DOWNTURM OVERBASECOAT FINISHED INSTOARMAT MIRAL PLASTERSYSTEM

75

75

INSULATION AS PERNZBC - H1

METAL OVERFLASHING SEALED INTOWALL CHASE (20mm x 10mm) & WITH

MASONRY FIXINGS

SELECTED ROOFMEMBRANE

ROOF MEMBRANE FLASHINGCHASED INTO WALL

SELECTED CONC.BLOCKSERIES (shown 20 seriesconc.block)

HANDRAIL DESIGN & HEIGHT INACCORDANCE WITH NZBCHANDRAIL PLATE ON EPDMGASKET WITH EPDM WASHERSUNDER FIXING WASHERS

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

HANDRAIL

CB 354

2014

Page 20: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

H3.1 JOISTS,

LAID TO A FALL

SELECTED CONC.BLOCK SERIES

(shown 20 series conc.block)

STOARMAT MIRAL

PLASTER SYSTEM

METAL OVER-FLASHING

TO BE CHASED AND

SEALED INTO WALL

WITH MS SEALANT

STO uPVC FINISHING

EDGE TO PLASTER

70

BACKING ROD & STO SEAL

JOINT INSTALLED AROUND

PERIMETER OF OPENING

PROPRIETARY SCUPPER

OUTLET - CUT TO SUIT

CUSTOM FOLDED RAIN

WATER HEAD

50mm DRIP EDGE

SECURE RWH WITH MASONRY

FIXINGS WITH EDPM WASHER

BETWEEN RWH AND STO

PLASTER FINISH

REBATE INTO

SUBSTRATE

SELECTED MEMBRANE

low point

INSULATION AS

PER NZBC - H1

MASONRY

FIXING

DEBRIS SCREEN

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

RWH/SCUPPER OPENING

CB 355

2014

Page 21: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

10

5

5

INSULATION AS

PER NZBC - H1

20 SERIES CONCRETE

MASONRY WALL

INSULATION AS

PER NZBC - H1

20 SERIES CONCRETE

MASONRY WALL

PREPARE REBATES AND

BRUSH APPLY TWO (2)

COATS OF STO FLEXYL

WATERPROOFING TO

HEAD & JAMB REBATES

BEFORE INSTALLING

JOINERY

STO PREMESHED

DRIP EDGE AT HEAD

MS SEALANT

CONTINUOUS ACROSS

HEAD & DOWN JAMBS

REMOVE

PROJECTING SILL

(as requested) -SHOWN DASHED

PROPRIETARY

ALU.WINDOW JOINERY

STOARMAT MIRAL

PLASTER SYSTEM

SCALE 1:5

BRUSHED STOFLEXYL

COAT

PREPARE REBATES AND

APPLY STO FLEXYL MESHED

WATERPROOFING TURNED

40mm UP JAMBS

HEAD DETAIL

SILL DETAIL

5

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

ALUMINIUM JOINERY - HEAD & SILL DETAIL

CB 400

2014

Page 22: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

5

INSULATION AS PER

NZBC - H1

20 SERIES CONCRETE

MASONRY WALL - REINFORCED

AS PER NZS 4229

PREPARE REBATES; BRUSH APPLY

TWO (2) COATS OF STO FLEXYL

WATERPROOFING TO JAMB & HEAD

REBATES BEFORE INSTALLING

JOINERY

MS SEALANT CONTINUOUS AROUND

HEAD & JAMBS

PROPRIETARY

ALU.WINDOW JOINERY

STOARMAT MIRAL

PLASTER SYSTEM

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

ALUMINIUM JOINERY - JAMB DETAIL

CB 401

2014

Page 23: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

5

INSULATION AS PER

NZBC - H1

20 SERIES

CONCRETE

MASONRY WALL

PROPRIETARY ALU.DOOR

JOINERY

SCALE 1:5

STO PREMESHED DRIP EDGE

MS SEALANT CONTINUOUS

AROUND HEAD & JAMBS

TIMBER SILL - ADJUST

PACKER TO SUIT FLOOR

COVERINGS

STOARMAT MIRAL

PLASTER SYSTEM -

150mm MIN.FLOOR SLABto GROUND LEVEL100mm MIN.FLOOR SLABto PAVING

LINE OF CONCRETE

BLOCK & FOUNDATION -

SHOWN DASHED

10m

m M

IN

.

PREPARE REBATES AND BRUSH

APPLY TWO (2) COATS OF STO

FLEXYL WATERPROOFING TO

ALL REBATES BEFORE

INSTALLING JOINERY

5mm

PREPARE REBATES AND

BRUSH APPLY STO FLEXYL

WATERPROOFING

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

ALU.JOINERY-DOOR HEAD & THRESHOLD DETAIL

CB 402

2014

Page 24: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

5

INSULATION AS PER

NZBC - H1

20 SERIES

CONCRETE BLOCK

AIRSEAL ON PEF ROD GAP

7.5-8mm APPROX & PACKER

PROPRIETARY ALU.DOOR

JOINERY

MS SEALANT CONTINUOUS

AROUND HEAD & JAMBS

STOARMAT MIRAL

PLASTER SYSTEM

PREPARE REBATES AND BRUSH

APPLY TWO (2) COATS OF STO

FLEXYL WATERPROOFING TO

ALL REBATES BEFORE

INSTALLING JOINERY

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

ALUMINIUM JOINERY - JAMB DETAIL

CB 403

2014

Page 25: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

INSULATION AS

PER NZBC - H1

20 SERIES CONCRETE

MASONRY WALL

INSULATION AS

PER NZBC - H1

20 SERIES CONCRETE

MASONRY WALL

STO PREMESHED DRIP EDGE

MS SEALANT CONTINUOUS

ACROSS HEAD & DOWN

JAMBS. TIMBER TRIM

TIMBER JOINERY PROFILES

AS PER NZS 3610

STOARMAT MIRAL

PLASTER SYSTEM

AIR SEAL OVER

BACKING ROD

H3.2 TIMBER PACKER ON

DPC UNDER SILL

REMOVE

PROJECTING SILL -

SHOWN DASHED

PREPARE REBATES AND BRUSH

APPLY TWO (2) COATS OF STO

FLEXYL WATERPROOFING TO ALL

REBATES BEFORE INSTALLING

JOINERY ON DPC & PLASTERING

PREPARE REBATES AND

BRUSH APPLY STO FLEXYL TO

INTERNAL REBATE WITH MESH

WATERPROOFING TURNED

40mm UP JAMBS OVER SILL

STOARMAT MIRAL

PLASTER SYSTEM

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

TIMBER JOINERY - HEAD & SILL DETAIL

CB 404

2014

Page 26: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

INSULATION/STAPPING

AND LINING

20 SERIES CONCRETE

MASONRY WALL

MS SEALANT CONTINUOUS

ACROSS HEAD & JAMBS,

TIMBER TRIM

STOARMAT MIRAL

PLASTER SYSTEM

PREPARE REBATES AND BRUSH

APPLY STO FLEXYL MESHED

WATERPROOFING TURNED 40mm

UP JAMBS

AIR SEAL OVER

BACKING ROD

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

TIMBER JOINERY - JAMB DETAIL

CB 405

2014

Page 27: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

50

INSULATION/STAPPING AND

LINING

20 SERIES

CONCRETE BLOCK

APPLY TWO (2) COATS OF STO

FLEXYL WATERPROOFING TO

ALL REBATES OVER BASE

COAT 50mm MIN.UP FACE OF

MASONRY WALL

STO PREMESHED DRIP EDGE

SEALANT OVER BOND

BREAKER CONTINUOUS

ACROSS HEAD & JAMB

TIMBER DOOR JOINERY

PROFILES AS PER NZS 3610

APPLY TWO COATS OF STO

FLEXYL WATERPROFFING TO

ALL REBATES OVER BASECOAT

50mm MIN.DOWN WALL

STOARMAT MIRAL

PLASTER SYSTEM

SCALE 1:5

AIR SEAL OVER

BACKING ROD

*

* REBATE TO SUIT

SILL PROFILE

LINE OF CONCRETE

BLOCK & FOUNDATION -

SHOWN DASHED

50

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

TIMBER DOOR JOINERY - HEAD & SILL DETAIL

CB 406

2014

Page 28: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

50

INSULATION/STAPPING AND

LINING (indicative only, notreq.for weathertightness)

20 SERIES

CONCRETE BLOCK

SEALANT OVER BOND BREAKER

CONTINUOUS ACROSS HEAD & JAMB

APPLY TWO COATS OF STO

FLEXYL WATERPROFFING TO

ALL REBATES OVER BASECOAT

50mm MIN.DOWN WALL

STOARMAT MIRAL

PLASTER SYSTEM

TIMBER DOOR JOINERY

PROFILES AS PER NZS 3610

AIRSEAL ON PEF ROD GAP

7.5-8mm APPROX & PACKER

ALU.EQUAL ANGLE

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

TIMBER DOOR JOINERY - JAMB DETAIL

CB 407

2014

Page 29: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

PROVIDE SEPARATION (ROOFUNDERLAY) UNDER METAL CAPPING

OVER 9mm H3 PLY ON DPCMETAL CAPPING WITH 5°MIN.FALL TO PARAPET -

MASONRY FIXINGS

SELECTED CONC.BLOCKSERIES (shown 20 series

conc.block)

SCALE 1:5

STOARMAT MIRALPLASTER SYSTEM

NOTE: CUT BLOCK TO SUIT OR BASECOAT PLASTERTO A FALL APPROX.18mm FROM FRONT EDGE BEFOREINSTALLING PLYWOOD ON DPC. ALTERNATIVELY USEH3.1 TIMBER PLATE, MAINTAINING FLASHING COVEROVER CONC.BLOCK OF 50mm MIN.

50

50

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

PARAPET/METAL FLASHING DETAIL

CB 500

2014

Page 30: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

NOTE: CUT BLOCKS TO SUIT or BASECOAT PLASTER TOA FALL 10° MIN.FOR STOCLEAR COATING SYSTEM -REFER TO DRAWING DETAIL CB 502

10°

STOFLEXYL MEMBRANEUNDER MESH COAT TO TOP &

SIDES, 75mm DOWNTURNOVER LEVELITE BASE COAT

SELECTED CONC.BLOCK SERIES(shown 20 series conc.block)

STOARMAT MIRALPLASTER SYSTEM

75

75

CUT CONC.BLOCK TO FORMREQUIRED SLOPE OF 10° MIN.

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

PLASTERED PARAPET/BALUSTRADE DETAIL

CB 501

2014

Page 31: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SELECTED CONC.BLOCK

SERIES (shown 20 series

conc.block)

SCALE 1:5

15

5

STOFLEXYL MESHED

WATERPROOFING

PAINTED, CLEAR COATED

or PLASTERED FINISH

MORTAR BED 15mm -

5mm FALL TO

INTERIOR SIDE

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

UNCOATED,PAINTED CLEAR COATED or PLASTERED

CB 502

2014

Page 32: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

ROOF SCREED TO AMIN FALL1.5°

CONCRETEROOF SLAB

SCALE 1:5

10°

STOFLEXYL MEMBRANE UNDER MESHCOAT TO TOP & SIDES, 75mm DOWNTURN

OVER LEVELITE BASE COATSELECTED CONC.BLOCK SERIES

(shown 20 series conc.block)

STOARMAT MIRALPLASTER SYSTEM

CUT CONCRETE BLOCK TO FORMREQUIRED SLOPE OF 10° MIN.

75

75

70

INSULATION AS PERNZBC - H1

SELECTED ROOFMEMBRANE 15

0

SELECTED ROOF MEMBRANEUPSTAND150mm MIN.

STO STICK ON CONNECTOR OR STOuPVC FINISHING EDGE & MS

SEALANT AT FLASHING

METAL OVERFLASHING SEALED INTOWALL CHASE (20mm x 10mm) & FIXED

WITH A MASONRY FIXINGS

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

PARAPET/ROOF/WALL DETAIL

CB 503

2014

Page 33: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:20

OVERLAY OF STOFLEXYL MESHEDWATERPROOFING TO TOP & SIDES- 75mm DOWNTURN OVER BASECOAT75

NOTE:1. ALL ADJACENT WALLS ARE TO BE STRUCTURALLY TIED WITH

STEEL REINFORCEMENT.2. BALUSTRADES TO HAVE 10° MIN.FALL TO TOP3. ALL BALUSTRADES/PARAPETS & WALL CAPS TO HAVE STOFLEXYL

MESHED WATERPROOFING4. STO FLEXYL MESHED WATERPROOFING MEMBRANE HAS BEEN

TESTED BY BRANZ TO AS/NZS4858 - AS REQUIRED BY E2/AS1 &CCANZ CP01:2014

LEVELLITE BASECOAT

SELECTED CONC.BLOCK SERIES(shown 20 series conc.block)

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

STOFLEXYL WATERPROOFING MEMBRANE

CB 504

2014

Page 34: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

50

mm

MIN

.CO

VE

R

60mm

H3.1 PRE PRIMED &PAINTED

FASCIA/BARGEBOARD

SOFFIT LINING

PRE FINISHED METALROOFING OVER ROOFUNDERLAY

INSULATION ASPER NZBC - H1

M12 BOLT FIXING

MS SEALANT 6-8mm,WATERPROOF

CONC.BLOCK BEFOREINSTALLING SOFFIT

SOFFIT FRAMING

20 SERIES CONCRETEMASONRY WALL

STOARMAT MIRALPLASTER SYSTEM TO

TOP OF WALL

NOTE: EAVE FLASHING REQUIRED WHERE• ROOF SLOPE LESS THAN OR EQUAL TO 10°• SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm• WIND ZONES ARE VERY HIGH or EXTRA HIGH

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

EAVES WITH OVERHANG

CB 600

2014

Page 35: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

NOTE: EAVE FLASHING REQUIRED WHERE• ROOF SLOPE LESS THAN OR EQUAL TO 10°• SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm• WIND ZONES ARE VERY HIGH or EXTRA HIGH, MS

SEALANT REQUIRED

50 m

m125

35

MIN

.CO

VE

R

INSULATION AS PERNZBC - H1

20 SERIES CONCRETEMASONRY WALL

STOARMAT MIRALPLASTER SYSTEM TO

TOP OF WALL

H3.1 PRE PRIMED &PAINTED FASCIA/BARGE

BOARD

M12 BOLT FIXING

PRE FINISHED METALROOFING OVER ROOFUNDERLAY

PURLIN - REFERNZS 3604

COMPLIANT EAVEFLASHING/E2/AS1

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

EAVES WITH NO OVERHANG

CB 601

2014

Page 36: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

PRE FINISHED METAL

FLASHING

LAP - REFER NZBC, TABLE 7

E2/AS1

H3.1 PRE PRIMED &

PAINTED FASCIA/BARGE

BOARD

PRE FINISHED METAL

ROOFING OVER ROOF

UNDERLAY

RAFTER - REFER NZS 3604

FOR SIZE

PURLIN - REFER NZS 3604

SOFFIT LINING

50/90

MIN.2 x crests

INSULATION AS

PER NZBC - H1

20 SERIES CONCRETE

MASONRY WALL

STOARMAT MIRAL

PLASTER SYSTEM

RAKING WALL

PLATE ON DPC

BOLT FIXING

FLYING RAFTER

OUTRIGGER

STO 6mm FINISHING EDGE

20 x 20mm SCOTIA BEAD

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

BARGE WITH OVERHANG

CB 602

2014

Page 37: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

RAFTER - REFER NZS

3604 FOR SIZE

PURLIN - REFER

NZS 3604

INSULATION/STAPPING

AND LINING

SELECTED CONC.BLOCK

SERIES (shown 20 series

conc.block)

STOARMAT MIRAL

PLASTER SYSTEM

STOFLEXYL MESHED

WATERPROOFING 75mm

MIN.DOWNTURN OVER BASECOAT

METAL OVER-FLASHING TO BE

CHASED AND SEALED INTO

WALL WITH MS SEALANT

35

75

STO uPVC FINISHING EDGE TO

PLASTER AND MS SEALANT AT

FLASHING JUNCTION

110m

m U

pstand for flashing

PROFILED ROOF FLASHING &

UNDERLAY TO RUN UP BENEATH

OVER-FLASHING AND TO BE

MECHANICALLY FIXED TO WALL

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

ROOF TO CONC.BLOCK GABLE END

CB 603

2014

Page 38: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:10

SELECTED FIBRECEMENT SOFFIT LINING

STOARMAT MIRALPLASTER SYSTEM

NOTE:• MAX.ANGLE OF SOFFIT RESTRICTED TO

BETWEEN 91° - 115°• SOFFITS ARE FIXED AFTER PLASTERING

BRUSH STOFLEXYLWATERPROOFING TO CONC.BLOCK

- 50mm MIN. PAST SOFFIT

PRE FINISHED METALROOFING OVER ROOFUNDERLAY

INSULATION/STAPPINGAND LINING

20 SERIES CONCRETEMASONRY WALL

50

6mm MAX.GAP WITH MS SEALANTor STO JOINT SEAL TAPE

The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

RAKING SOFFIT (REVERSED)

CB 604

2014

Page 39: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

NOTE: INSTALL DIVERTER FLASHING

AT ROOF/GUTTER JUNCTION

METAL OVER-FLASHING TO BE CHASED

AND SEALED INTO WALL WITH MS SEALANT

SECURED WITH MASONRY FIXINGS

Refer E2/AS1 table 7

TIMBER ROOF STRUCTURE

STOARMAT MIRAL

PLASTER SYSTEM

35

75

STO uPVC FINISHING EDGE TO

PLASTER WITH MS SEALANT

110m

m U

pstand for flashing

PROFILED ROOF APRON

FLASHING & ROOF UNDERLAY TO

RUN UP BEHIND FLASHING

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

GABLE END/ROOF JUNCTION

CB 700

2014

Page 40: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

R

e

fe

r E

2

/A

S

1

T

a

b

le

7

TIMBER ROOF STRUCTURE

METAL OVER-FLASHING TO BE CHASED

AND SEALED INTO WALL WITH MS SEALANT

SECURED WITH MASONRY FIXINGS

35

75

STO uPVC FINISHING EDGE TO

PLASTER WITH MS SEALNT

110m

m U

pstand for flashing

PROFILED ROOF, APRON

FLASHING & ROOF UNDERLAY TO

RUN UP BEHIND FLASHING

NOTE:ENSURE APRON FLASHING IS OVER

FLASHED AT BOTH ENDS

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

APRON FLASHING

CB 701

2014

Page 41: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

35

75

110m

m U

pstand for flashing

20m

m

80mm 80mm

TIMBER ROOF

STRUCTURE

METAL OVER-FLASHING TO BE CHASED

AND SEALED INTO WALL WITH MS SEALANT

SECURED WITH MASONRY FIXINGS

STOARMAT MIRAL

PLASTER SYSTEM

STO uPVC FINISHING EDGE TO

PLASTER WITH MS SEALANT

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

PARALLEL ROOF/HIDDEN GUTTER

CB 702

2014

Page 42: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

SELECTED MEMBRANE FINISH OVER H3"C" FACED

PLYWOOD LAID TO A 1:30MIN.FALL GLUE & SCREW

TO TIMBER FRAMING, ALL EDGES SUPPORTED

MIN. 5mm RADIUS

TO PLYWOOD

50mm MIN.LAP -

REFER E2/AS1

S/S ANGLE

PRE FINISHED

METAL SPOUTING

AND BRACKETS

H3.1 PRE PRIMED & PAINTED

FASCIA/BARDGE BOARD MS

SEALANT ON STO SEAL TAPE

50

INSULATION AS PER

NZBC - H1

20 SERIES CONCRETE

MASONRY WALL

STOARMAT MIRAL

PLASTER SYSTEM

50

CO

VE

R

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

FACE FIXED FASCIA/MEMBRANE ROOF

CB 703

2014

Page 43: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

INSULATION AS PER NZBC

- H1

SELECTED CONC.BLOCK SERIES

(shown 20 series conc.block)

STOARMAT MIRAL

PLASTER SYSTEM

SELECTED HORIZONTAL

TIMBER WEATHERBOARDS

OVER 20mm DRAINED CAVITY

WALL UNDERLAY

NOMINAL H3.1 TIMBER

BATTEN

E2/AS1 COMPLIANT BACK

FLASHING WITH MS SEALANT

50m

m M

IN

.C

OV

ER

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

EXTERNAL CORNER

CB 800

2014

Page 44: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

50m

m M

IN

.C

OV

ER

NOMINAL H3.1

TIMBER BATTEN

STO uPVC FINISHING EDGE

WITH MS SEALANT

E2/AS1 COMPLIANT

FLASHING IN

CONC.BLOCK CHASE

SELECTED HORIZONTAL

TIMBER WEATHERBOARDS

OVER 20mm DRAINED CAVITY

INSULATION AS PER

NZBC - H1

SELECTED CONC.BLOCK

SERIES (shown 20 series

conc.block)

STOARMAT MIRAL

PLASTER SYSTEM

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

INTERNAL CORNER

CB 801

2014

Page 45: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

INSULATION/STAPPING

AND LINING

WALL PLATE ON

DPC

CAVITY CLOSURE

SELECTED FLOORING

JOISTS - REFER

NZS3604:2011 FOR SIZE

STOARMAT MIRAL PLASTER

SYSTEM WITH STO uPVC

FINISHING EDGE

15

50

WALL UNDERLAY

SELECTED CONC.BLOCK SERIES

(shown 20 series conc.block)

SELECTED HORIZONTAL

TIMBER

WEATHERBOARDS OVER

20mm DRAINED CAVITY

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

HORIZONTAL JUNCTION/WEATHERBOARD

CB 802

2014

Page 46: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

MS SEALANT OVER

PEF ROD

INSULATION AS

PER NZBC - H1

SELECTED CONC.BLOCK

SERIES (shown 20 series

conc.block)

STOARMAT MIRAL

PLASTER SYSTEM

NOMINAL H3.1 TIMBER

BATTEN

PROFILED FOAM CLOSURE

STRIP UNDER CLADDING

HORIZONTAL PROFILED METAL

WALL CLADDING

FLASHING (SPECIFY COATING)

E2/AS1 COMPLIANT FLASHING

REBATED IN CHASE CUT INTO

CONCRETE BLOCK

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

EXTERNAL CORNER HORIZ.PROFILED METAL

CB 850

2014

Page 47: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

27m

m M

IN

.C

OV

ER

INSULATION AS PER

NZBC - H1

SELECTED CONC.BLOCK

SERIES (shown 20 series

conc.block)

DPC

NOMINAL H3.1 TIMBER

BATTEN

SELECTED INTERNAL

LININGS

E2/AS1 COMPLIANT BACK

FLASHING CHASED INTO

CONC.BLOCK

MS SEALANT OVER PEF ROD

PROFILED FOAM CLOSURE

STRIP UNDER CLADDING

HORIZONTAL PROFILED METAL

WALL CLADDING

PURPOSE MADE FLASHING

(SPECIFY COATING)

STOARMAT MIRAL SYSTEM

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

INTERNAL CORNER HORIZ.PROFILE METAL

CB 851

2014

Page 48: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

INSULATION AS PER

NZBC - H1

WALL PLATE ON

DPC

HORIZONTAL PROFILED

METAL CLADDING

CLOSE CAVITY VENTED

E2/AS1 COMPLIANT

FLASHING

SELECTED

FLOORING

JOISTS - REFER

NZS3604 FOR SIZE

CEILING

BATTENS

15

50

WALL UNDERLAY

20mm DRAINED &

VENTED CAVITY

SELECTED CONC.BLOCK SERIES

(shown 20 series conc.block)

STOARMAT MIRAL PLASTER

SYSTEM WITH STO uPVC

FINISHING EDGE

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

HORIZONTAL JUNCTION/HORIZ.PROFILED METAL

CB 852

2014

Page 49: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

MS SEALANT

OVER PEF ROD

INSULATION AS PER

NZBC - H1

SELECTED CONC.BLOCK

SERIES (shown 20 series

conc.block)

STOARMAT MIRAL

PLASTER SYSTEM

DPC

E2/AS1 COMPLIANT BACK

FLASHING

20

VERTICAL PROFILED

METAL WALL CLADDING

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

EXTERNAL CORNER VERTICAL.PROFILED METAL

CB 853

2014

Page 50: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

INSULATION AS PER

NZBC - H1

SELECTED CONC.BLOCK

SERIES (shown 20 series

conc.block)

E2/AS1 COMPLIANT BACK

FLASHING CHASED INTO

CONC.BLOCK50

SELECTED INTERNAL

LININGS

MS SEALANT JOINT OVER

PEF ROD

VERTICAL PROFILED METAL WALL

CLADDING

STOARMAT MIRAL PLASTER

SYSTEM

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

INTERNAL CORNER VERTICAL PROFILE METAL

CB 854

2014

Page 51: STO CONCRETE BLOCK DRAWING  · PDF fileSto Concrete Block Alu.Joinery - Jamb Detail CB 401 Sto ... STO CONCRETE BLOCK DRAWING REGISTER CB 002 2014. ENSURE CONC.BLOCK WALLS ARE

SCALE 1:5

INSULATION AS

PER NZBC - H1

WALL PLATE ON

DPC

VERTICAL PROFILED

METAL CLADDING

SELECTED

FLOORING

JOISTS - REFER

NZS3604 FOR SIZE

CEILING

BATTENS

STOARMAT MIRAL

PLASTER SYSTEM WITH

STO uPVC FINISHING EDGE

50

WALL UNDERLAY

SELECTED CONC.BLOCK SERIES

(shown 20 series conc.block)

3.5mm VENTILATION GAP,

NON VENTED CLOSER

FLASHING

6

3.5

The information contained in this detail is based on our experience and testing and represents the latest information available at the date of

issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be

used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the

responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.

STO CONCRETEBLOCK

STO CONCRETE BLOCK

HORIZ.JUNCTION/VERTICAL PROFILED METAL

CB 855

2014