stile t of ontents - sweetssweets.construction.com/swts_content_files/613s/715367.pdf · stile®...
TRANSCRIPT
STILE®
PST-1© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
Fastener Installation Technique ............................PST-8Condition of Substructure .....................................PST-8Ventilation .............................................................PST-9Panel Applications ................................................PST-9
Eave Detail .........................................................PST-10Extended Eave Detail .........................................PST-10Gutter Detail .......................................................PST-11Valley Detail ........................................................PST-11Slope Change Detail...........................................PST-12Endlap Detail ......................................................PST-12Rake Detail .........................................................PST-13Formed Rake Detail............................................PST-13Rake Parapet Siding Detail ................................PST-14Endwall with Counter Detail................................PST-14Endwall with Reglet Detail ..................................PST-15Junction Sheet Detail..........................................PST-15Ridge/Hip Detail..................................................PST-16Formed Ridge/Hip Detail ....................................PST-16Formed Vented Ridge Detail ..............................PST-17Roof Vent Detail..................................................PST-17
Notes ..................................................................PST-18
Table of ConTenTs
Product Page No.
Stile Panel Profile .................................................PST-2Panel Overview ....................................................PST-2
Eave .....................................................................PST-3Extended Eave .....................................................PST-3Cleat .....................................................................PST-3Stile Starter ...........................................................PST-3Box Gutter ............................................................PST-3Box Gutter End .....................................................PST-3Universal Gutter/Downspout Strap .......................PST-34" x 31/2" Downspout .............................................PST-34" x 31/2" 95° Elbow ...............................................PST-3Downspout Bracket ..............................................PST-3Stile Valley ............................................................PST-3Valley Cover .........................................................PST-3Formed Rake ........................................................PST-3Rake .....................................................................PST-3Rake Starter .........................................................PST-3Pitch Break ...........................................................PST-4Counter Flashing ..................................................PST-4Reglet Flashing.....................................................PST-4Ridge/Hip Cover ...................................................PST-4Formed Ridge .......................................................PST-4Vent Drip ...............................................................PST-4Stile C-Closure .....................................................PST-4Junction Sheet ......................................................PST-4Stile Ridge Drip.....................................................PST-4
Stile Inside/Outside Closure .................................PST-5Stile Formed Ridge Closure .................................PST-5Universal Closure .................................................PST-5Tube Sealant ........................................................PST-5Tape Sealant.........................................................PST-5Rubber Roof Jack .................................................PST-5Touch-Up Paint .....................................................PST-5Stile Roof Vent ......................................................PST-5Vent Material.........................................................PST-5
UL 580 Wind Uplift Information .............................PST-6Section Properties and General Information ........PST-7
Panel Information
Flashing Profiles
Accessory Profiles
Detail Conditions
Notes
Product Page No.
Testing Information
Design/Installation Considerations
PST-2
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
Panel overview
PANEL PROFILE
SLOPE
SUBSTRATE
COVERAGE
LENGTH
AVAILABILITY
APPLICATION
FASTENING SYSTEM
FASTENERS
MATERIALS
FINISH
The minimum recommended slope for any Stile roofing panel is 3:12.
The recommended substrate is 5/8" plywood with a 30 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure. If your application is over a solid substrate other than 5/8" plywood, please contact the your Metal Sales branch location (see pages PGI-2-3).
Each panel has a coverage of 39.4" (1 meter).
Minimum factory cut length is 3'-0", and the maximum panel length is 20'-0". Lengths between 3'-0" and 20'-0" will be cut at 1'-0" increments.
Stile panels are available in 26 Gauge Galvanized (G-90) coating.
Architectural panel.
Direct Fasten (exposed).
The fastener selection guide should be consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14).
5"
1/2" Step2"
2"
12"
Available in lengths
up to 20'-0"
PERFORMANCE TESTUL 580, UL 790, UL 263, UL 2218, Miami-Dade County, FBC
Steel Grade 40, per ASTM A-653
**PVDF Fluorocarbon ** Meets both Kynar 500 and Hylar 5000 specifications.
13/16"
42.3" Overall w
idth
39.4" Coverage
STILE®
PST-3© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
Length 10'-2" - *Specify Slope Angle
EAVE
flashing Profiles
5"
1"
1"4"
5"
11/2"
16"
Hem
EXTENDED EAVE CLEAT
STILE STARTER BOX GUTTER BOX GUTTER END
UNIVERSAL GUTTER/
1/2"
21/2"
C135°
Length 10'-2"
Length 10'-2", 20'-3" - *Specify Slope Angle
C
31/2"
5"
1"
1"
Hem
4"
5"
X*
DOWNSPOUT STRAP
Length 10'-2"
C
Hem
21/2"X*
5/8"
31/8"
4"
DOWNSPOUT 4" x 31/2" 950 ELBOW 4" x 31/2"
DOWNSPOUT BRACKET
(Also available 6" x 4")Length 10'-2", 20'-3"
(Also available 6" x 4")
(Also available 6")
C
VALLEY
C
15"X*
Length 10'-2", 20'-3" - *Specify Slope Angle
RAKE
Length 10'-2", 20'-3"
C
5/8"
5"
Hem
4"
6"
5/8"
11/2"X*
3" C
Length 10'-2" - *Specify Slope Angle
11/2"
VALLEY COVER
FORMED RAKE RAKE STARTER
3/8"
1/2"21/8"
2"
X*
53/8"
CHem
C1"
7/8"
23/16"3/4"
23/16" 41/2"
1/2"
C
13/4"27/8"
Length 10'-2" - *Specify Slope Angle
Length 10'-2"Length 3'-6"
4" 31/2"
C
4"
C
31/2"
PST-4
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
REGLET FLASHING
1/2"C
1"
2"
Hem
Length 10'-2"
flashing Profiles (ConT.)PITCH BREAK
RIDGE/HIP COVER
C
53/8"X*
Hem
Length 10'-2", 20'-3" - *Specify Slope Angle
C
6"
X*4"
Length 10'-2" - *Specify Slope Angle
Length 10'-2", 20'-3"
C- Indicates color side of flashing.
COUNTER FLASHING
1" C
3/4"
3/4"
5/8"
Length 10'-2"
FORMED RIDGE VENT DRIP
STILE C-CLOSURE JUNCTION SHEET STILE RIDGE DRIP
31/4"
3/4"
60°
C
Length 10'-2"
3/4"
1/2" 1/4"
1/2"
3/4"65/8"
17/8"4"
C
11/2"
13/4"
41/2"
5"
471/5"
5"5"
23" 7/8"
29/16"
X*
Length 3'-6"
C
Length 1'-11" *Specify Slope Angle
11/4" 120°
STILE®
PST-5© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
aCCessory Profiles
TUBE SEALANT
10.3 oz. CartridgeUrethane
TAPE SEALANT
7/8" X 3/16" X 25'Double BeadButyl - Gray
MINI (1/4" to 11/8" O.D. Pipe)#2 (13/4" to 3" O.D. Pipe)#4 (3" to 6" O.D. Pipe)#6 (6" to 9" O.D. Pipe)#8 (7" to 13" O.D. Pipe)
RUBBER ROOF JACK
TOUCH-UP PAINT
Available in pintsPVDF
STILE FORMED RIDGE UNIVERSAL CLOSURE
STILE ROOF VENT
STILE INSIDE/OUTSIDECLOSURE CLOSURE
163/4"
35/8"
141/8"
41/2"
Side View
Front View
VENT MATERIAL
33/8"
4"
7/8"
Polyethylene Foam Polyethylene Foam1" x 11/2" x 50' Polyethylene Foam1" x 11/2" x 10' Polyethylene Foam
Right Valley Closure
Left Valley Closure
STILE VALLEY CLOSURE
Polyethylene Foam
Underwriters Laboratories Inc. ®UL®
LISTED
PST-6
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
1. Metal Roof Deck Panels* No. 26 MSG min thick coated steel. Width 39.4 in., height at ribs 1-3/16 in. METAL SALES MANUFACTURING CORPORATION - “Stile”
2. Cover Board (Optional)-1/4 in. Georgia-Pacific “Dens- Deck”.
3. Underlayment 30 lb organic felt. Sides overlapped min 2 in., end laps per manufacturer’s instructions.
4. Insulation* (Optional)-Any UL Classified rigid insulation, thickness not to exceed 3-1/2 in.
5. Fasteners (Screws) Fasteners to be No. 14-14 x 1-1/2 in., hex head, Type AB, self- tapping screws with sealing washer and painted finish.
5A. Fasteners (Rivets) Fasteners used to attach panels (Item 1) at side and end laps to be 1/8 in. diameter by 3/16 in. long stainless steel pop rivets.
6. Plywood Decking Decking to be min 5/8 in. (19/32 in. actual) thick. APA 20 span rated plywood sheathing. Fastened to supports with No. 8 by 2 in. long coarse thread wood screws. All butt joints to be sealed against leakage by using tape and/or caulk or with one-part urethane sealant.
7. Supports (Joists) Spaced max 2 ft OC. Graded dimension lumber, No. 2 or better.
Refer to general information, Roof Deck Construction, for Items not evaluated.
*Bearing the UL Classification Marking
Ul 580 wind UPlifT informaTion
Construction No. 533November 11, 1999Uplift - Class 90Fire Not Investigated
STILE
1
2
3
5 6
7
1
2
35A
65
36" o.c.
5"
4
STILE®
PST-7© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
seCTion ProPerTies and general informaTion
1. TheoreticalsectionpropertieshavebeencalculatedperAISI2001“SpecificationfortheDesignofCold-formedSteelStructuralMembers.”IxxandSxxare effectivesectionpropertiesfordeflectionandbending.2. AllowableloadiscalculatedinaccordancewithAISI2001specificationsconsideringbending,shear,combinedbendingandshear,deflection,uplifttesting, pulloutfrom5/8"plywood,andpullover.Allowableloadconsiderstheworstcaseof3and4equalspanconditions.Allowableloaddoesnotaddressweb crippling.Panelweightisnotconsidered.3. DeflectionconsiderationislimitedbyamaximumdeflectionratioofL/180ofspan.4. Allowableloadsdonotincludea1/3stressincreaseinuplift.
ALLOWABLE UNIFORM LIVE LOADS PSF(3 or More Equal Spans)
1'-0"
SECTION PROPERTIES
Bottom in CompressionWidth(in.)
YieldKSI
39.4" 2526
Ga. SxxIn3/ft
IxxIn4/ft
WeightPSF
0.83
Top in Compression
SxxIn3/ft
IxxIn4/ft
0.0396 0.0644 0.0396 0.0643
Outward Uplift (Stress) Load
2'-0" 3'-0"103 77 50
2"
2"
12"
Available in lengths
up to 20'-0"
42.3" Overall width
39.4" Coverage
GENERAL INFORMATIONATTACHMENT DETAIL
FASTENING PATTERNS
The minimum recommended slope for the Stile® roof panel is 3:12.
The recommended substrate is 5/8" plywood with a 30 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure.NOTE: Stile® roof panels are not recommended for use over open structural framing.
Stile® panels have a coverage of 39.4" (1 meter).
Minimum factory cut panel length is 3'-0". Maximum panel length is 20'-0". Panel lengths are available in 1'-0" increments.
The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements. NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. Finish: Kynar 500 (PVDF) colors.Gauge: 26 ga standard
1/4"-14 x 1 1/2" Woodscrew XLStile® Panel
Stile® Closure
Tube Sealant (Top and Bottom of Closure)
1/8" x 3/16" Pop Rivet with Tube Sealant1/4"-14 x 1 1/2" Woodscrew XL
Stile® Panel
Pop Rivet or Stitch Screw w/ Tube Sealant
END FASTENING PATTERN
Interior Fastening Patternat every third step
End Fastening Pattern
End Fastening Pattern
Sidelaps fastened 1'-0" o.c. with a 1/8" x 3/16" Pop Rivet or a1/4"-14 x 1 7/8" Stitch Screw
High end
Low end
Slope
Substructure
Coverage
Length
Fasteners
Availability
PST-8
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
design / insTallaTion ConsideraTions
To prevent wobbling - Make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket - tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time.Protect drill point - Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. Correct pressure will allow screw to drill and tap without binding.Drilling through sheet and insulation - Ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the point - apply more pressure after drill point contacts purlin or girt.
Recommended Tool Type - Use depth locating nose or adjustable clutch on screw gun to prevent overdrilling and strip out. Do not use impact tools or runners.Seating the washer - Apply sufficient torque to seat the washer - do not overdrive the fastener.
FASTENER INSTALLATION TECHNIQUE
Whether over solid substrate or open structural framing, panel distortion may occur if not applied over properly aligned and uniform substructure.
The installer should check the roof deck for squareness before installing Stile panels. Several methods can be used to verify squareness of the structure for proper installation of the panels.
METHOD "A" - One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension.
METHOD "B" - The 3-4-5 triangle system may also be used. To use this system measure a point from the corner along the edge of the roof at a module of three (3). Measure a point from the same corner along another edge at a module of four (4). Then by measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square, the roof system cannot be installed as shown in these instructions.
CONDITION OF SUBSTRUCTURE
METHOD A
METHOD B4
30
30
35
TOO LOOSESealing material is not visible;not enough compression to
seal properly.
CORRECTSealing material slightly vis-ible at edge of metal washer.
Assembly is watertight.
TOO TIGHTMetal washer deformed; sealing material pressed
beyond washer edge.
WO
OD
SC
RE
W
STILE®
PST-9© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
design / insTallaTion ConsideraTions (ConT)
Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency.
Condensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique with metal roofing; these problems are common to all types of construction.
The underside of the metal roof on a typical Architectural building should be protected from condensation by installing panels directly over a minimum 30 lb moisture barrier and uniform solid substrate. This reduces airspace and the potential of condensation forming on the underside of the panels.
VENTILATION
Typical metal building (no attic)
Vent
Vent at wall Vent at eave
Building with attic or retrofitted
Vent
Insulation
PANEL APPLICATIONS
The following chart highlights UL 580 Class 90 for fastener spacing on the selected applications (see Fastener Selection Guide page PGI-12-14 for other fasteners available). For more information on UL Construction numbers, refer to UL Roofing Materials and System Directories.
* ABMP XL Fastener also available in #1/4-14 x 1" - Painted.** Based on UL-580. Subject to project loading, closer fastener spacing may be required. Contact your local Metal Sales branch representative for more information (see pages PGI-2-3).
NUMBER REQUIREDTYPE OF FASTENERAPPLICATION INSTALLATION
REQUIREMENTSFASTENERSPACINGPANEL TYPE
1/4"-14 x 1 1/2" ABMP XL - PAINTED 4 FASTENERS*26 GAUGE 3'-0" O.C.**FASTENERS OVER
5/8" PLYWOOD DECKCONST. #533
UL-90STILE
PST-10
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
eave deTail
exTended eave deTail
1/4"-14 x 11/2" Woodscrew XL (1'-0" o.c.)
Stile Closure
Double Bead Tape Sealant
Stile Starter
Cleat
Stile Panel
Moisture Barrier (by others)
Eave
#10-12 x 1" PHW (1'-0" o.c.)
Cleat
Extended Eave
3/16" x 6" Spacer
1/4"-14 x 11/2" Woodscrew XL (see below)
Double Bead Tape Sealant
1/4"-14 x 11/2" Woodscrew XL (1'-0" o.c.)
Stile Closure
Double Bead Tape Sealant
Stile Starter
Stile Panel
Moisture Barrier (by others)
#10-12 x 1" PHW (1'-0" o.c.)
3/16" x 6" Spacer
1/4"-14 x 11/2" Woodscrew XL (see below)
Double Bead Tape Sealant
sTile®
3:12 SlopeMinimum
3:12 SlopeMinimum
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
STILE®
PST-11© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
gUTTer deTail
Double Bead Tape Sealant
Box GutterUniversal Gutter / Downspout Strap
1/4"-14 x 11/2" Woodscrew XL (1'-0" o.c.)
Stile Closure
Stile Starter
Stile PanelMoisture Barrier (by others)
3/16" x 6" Spacer
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet
1/4"-14 x 11/2" Woodscrew XL (see below)
sTile® valley deTail
Valley Plate
Universal Closure
Stile Panel
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet (every other rib)1/4"-14 x 11/2" Woodscrew XL (see below)
Valley
3:12 SlopeMinimum
3:12 SlopeMinimum
Moisture Barrier (by others)
#1/4-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
PST-12
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
sloPe Change deTail
sTile®
3:12 SlopeMinimum
Double Bead Tape Sealant
1/4"-14 x 11/2" Woodscrew XL (see below)
Stile Closure
Stile Closure
Stile PanelMoisture Barrier (by others)
Pitch Break
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet (every other rib)
1/4"-14 x 11/2" Woodscrew XL (see below)
endlaP deTail
1/4"-14 x 11/2" Woodscrew XL (see below)
3:12 SlopeMinimum
Tube Sealant (put in flats)
4" overlap
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
STILE®
PST-13© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
rake deTail
sTile® formed rake deTail
1/4"-14 x 11/2" Woodscrew XL (1'-0" o.c.)
Cleat
Rake
Stile Panel
Moisture Barrier (by others)
Rake Starter
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet (1'-0" o.c.)
Fastener (by others)
1/4"-14 x 11/2" Woodscrew XL (1'-0" o.c.)
Formed Rake
Stile Panel
Moisture Barrier (by others)
Rake Starter
PST-14
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
rake ParaPeT siding deTail
endwall wiTh CoUnTer deTail
Moisture Barrier (by others)
sTile®
1/4"-14 x 11/2" Woodscrew XL (1'-0" o.c.)
Rake Starter
Stile Panel
Pitch Break
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet (1'-0" o.c.)
1/4"-14 x 11/2" Woodscrew XL (1'-0" o.c.)
Fastener (by others)
Moisture Barrier (by others)
Counter Flashing
Stile Panel
Pitch Break
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet (every other rib)
1/4"-14 x 11/2" Woodscrew XL (see below)
Fasteners (by others)
Stile Closure
Tube Sealant3:12 SlopeMinimum
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
STILE®
PST-15© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
endwall wiTh regleT deTail
JUnCTion sheeT deTailsTile®
Moisture Barrier (by others)
Reglet Flashing
Stile Panel
Pitch Break
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet (every other rib)
1/4"-14 x 11/2" Woodscrew XL (see below)
Fasteners (by others)
Stile Closure
Tube Sealant
Moisture Barrier (by others)
Junction Sheet
Stile PanelDouble Bead Tape Sealant
1/4"-14 x 11/2" Woodscrew XL (see below)
Fasteners (by others)Counter Flashing
Tube Sealant
3:12 SlopeMinimum
3:12 SlopeMinimum
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
PST-16
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
ridge/hiP deTail
sTile®
Moisture Barrier (by others)
Stile Panel
Double Bead Tape Sealant1/8" x 3/16" Pop-Rivet (every other rib)
1/4"-14 x 11/2" Woodscrew XL (see below)
Stile Closure
Ridge/Hip Cover
formed ridge/hiP deTail
Moisture Barrier (by others)
Stile Panel
Double Bead Tape Sealant
1/8" x 3/16" Pop-Rivet (every other rib)
1/4"-14 x 11/2" Woodscrew XL (see below)
Stile Closure / Stile Hip Closure
Formed Ridge/Hip Cover
3:12 SlopeMinimum
3:12 SlopeMinimum
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
STILE®
PST-17© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
formed venTed ridge deTail
Vent Drip
Double Bead Tape Sealant
Offset CleatStile Ridge Drip
#14-13 x 2" (1'-0" o.c.)Vent Material
Stile Panel1/8" x 3/16" Pop-Rivet (1'-0" o.c.)
Stile Closure / Stile Hip Closure
Formed Ridge1/8" x 3/16" Pop-RivetDouble Bead Tape SealantMoisture Barrier (by others)
1/4"-14 x 11/2" Woodscrew XL (see below)
31/4"
7/8"
sTile® roof venT deTail
3:12 SlopeMinimum
3:12 SlopeMinimum
1/4"-14 x 11/2" Woodscrew XL
Stile Roof Vent
Roof Opening
91/2"
17"
91/2" x 17" Field Cut Roof Opening
Stile Roof Vent
Stile Roof Panel
Double Bead Tape Sealant
1/4"-14 x 11/2" Woodscrew XL
Stile Fastening Pattern
PST-18
STILE®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com
noTes