sti ub2 instruction manual

8
ADA for operation UB-2 2” Universal Button UB-2/LTUL Universal Button with Latching Timer For UB-2/LTUL the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. For access control installations, power for the LT-1UL Timer must be supplied by a power source listed to UL294. When used for access control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should be used. Pour les modèles UB-2/LTUL, la minuterie intégrée doit être installée et utilisée suivant la fiche d’installation LT-1UL fournie. Pour les installations de contrôle d’accès, l’alimentation de la minuterie LT-1 doit être fournie par une source homologuée UL294. Lorsque cet appareil est utilisé aux fins de contrôle d’accès, il doit faire partie d’un système de porte de sortie à accès contrôlé. Il incombe donc à l’AHJ local d’autoriser l’utilisation de cet appareil au lieu d’un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés. We protect the things that protect you.

Upload: jmac-supply

Post on 08-Sep-2015

236 views

Category:

Documents


0 download

DESCRIPTION

Buy the STI UB2 at JMAC Supply!https://www.jmac.com/STI_UB2_p/sti-ub2.htm?=scribd

TRANSCRIPT

  • ADAfor operation

    UB-2 2 Universal ButtonUB-2/LTUL Universal Button with Latching Timer

    For UB-2/LTUL the enclosed timer is to be used and installed per the enclosed LT-1UL installationsheet. For access control installations, power for the LT-1UL Timer must be supplied by a powersource listed to UL294. When used for access control, this device shall be used as part of anaccess controlled egress door system. It is up to the local AHJ to allow use of this device in placeof an automatic sensor. For higher security installations, lower time limits should be used.

    Pour les modles UB-2/LTUL, la minuterie intgre doit tre installe et utilise suivant la fichedinstallation LT-1UL fournie. Pour les installations de contrle daccs, lalimentation de la minuterieLT-1 doit tre fournie par une source homologue UL294. Lorsque cet appareil est utilis aux finsde contrle daccs, il doit faire partie dun systme de porte de sortie accs contrl. Il incombedonc lAHJ local dautoriser lutilisation de cet appareil au lieu dun capteur automatique. Pourles installations de scurit plus renforce, des dlais infrieurs doivent tre utiliss.

    We protect the things that protect you.

  • - 2 -

    NOTESIt is important to read, understand and follow all instructions provided with thisproduct. It is the installers responsibility to comply with NFPA 70 & 101, NEC,mounting specifications according to ADA and other applicable electrical codes. ForType SM (Self Monitored) rating, the term Emergency message may be installed onModel UB-1 when used in a system with a Listed, compatible Releasing Device. Allother applications are rated Type NM (Non-Monitored) for non-emergency signaling.To avoid electrical shock, DO NOT attempt to install this product when power is on.ADA mounting compliance requires the operable part of the initiating device shallnot be less than 3 1/2 ft. (1.1m ) or greater than 4 1/2 ft. (1.37m) above finishedfloor surface. After installation and testing are complete, provide a copy of thismanual to all personnel responsible for testing and maintenance of this product. REMARQUESIl est important de lire, de comprendre et de suivre toutes les instructions fournies avec ceproduit. Il incombe linstallateur de se conformer aux normes NFPA 70 et 101, NEC, auxspcifications de montage selon lADA et aux autres codes de llectricit en vigueur. Pour lescotes de type SM (auto surveille), le message dUrgence peut tre appos sur le modle UB-1 lorsquil est utilis dans un systme intgrant un dispositif de dclenchement compatible ethomologu. Toutes les autres applications sont cotes de Type NM (non surveille) pour lasignalisation non urgente. Pour viterun choc lectrique, NE tentez PASdinstaller ce produit lorsquil est soustension. La conformit aux rglesdinstallation de lADA exige que lapartie utilisable du dispositif dedclenchement soit installe unehauteur situe entre 3 1/2 pi (1,1 m) et4 1/2 pi (1,37 m) au-dessus duplancher fini. Une fois linstallation et lesessais termins, vous devez fournir unecopie de ce manuel lensemble dupersonnel charg de lessai et delentretien de ce produit.

    SWITCH RATING 2 Independent Form C contacts UB-2 rated at: 10A, 1/2 HP, 125/250 VAC6A, 30 VDC100,000 OperationsTemperature: -40 to 185F (-40 to 85C)

    Model UB-2/LTULForm C contacts on timer rated:30 VDC 3A, 1.0 pf

    OF #2 ARROW

    1

    3.22 in.(82mm)

    4.83 in.(123mm)

    2 in.(51mm)

    .9 in.(24mm) 1.33 in.

    (34mm)

  • - 3 -

    TO CHANGE BUTTON COLOR AND ROUND MESSAGE

    1. Choose button message and color. If same as existing, proceed to 2. To remove push button actuator assembly, squeeze actuator tabs in di-rection of #1 arrows.

    3. Push acutator through plate in direction of #2 arrow.4. Align actuator cap to push button actuator. Align button slots to tabs onpush button actuator.

    5. Snap button onto push button actuator and rotate right to lock.6. Insert spring into push button actuator.7. Squeeze legs of push button actuator and align into die cast plate.

    1

    2

    OF #2 ARROW

    1

    1

    1

    2

    ALIGN TAB ON ACTUATORWITH SLOT BUTTON.TURN CLOCKWISE TO LOCK.INSERT ASSEMBLY WITHSPRING INTO PLATE.

    OF #2 ARROW

    1

    DIE CAST PLATE SPRING

    PUSH BUTTON ACTUATOR

    ACTUATOR CAP2 in. BUTTON

    OF #2 ARROW

    1

  • - 4 -

    CHANGE TOP MESSAGERefer to notes on pg. 2 for EMERGENCY message use.

    1. Remove LED circuit board.2. Remove current message by pushing in and down on tabs 1 and 2 with asmall screwdriver. If necessary, also push in and down on tabs 3 and 4.Once message is loose, remove from the front of the plate.

    3. Select new message and snap into place. Blank plates are included tocreate your own custom message.

    2

    12

    3 4

    SCREWDRIVER

    UB-1L LED PCBNYLON WASHER

    SELF TAPPING SCREW

    1

  • - 5 -

    INSTALL OR REMOVE CONTACT BLOCK3

    BUTTON ACTIVATED

    M

    TOP TAB

    A

    B

    STEP A COMPLETED

    STEP B

    STEP A

    STEP C

    REMOVERepeat STEP A for the top and bottom tab before removing contact block.Step A: Position small flat screwdriver blade under tab and gently rotateuntil tab disengages. The contact block will rotate a little. Do NOT pull yet.Step B: Repeat for opposite tab.Step C:When both tabs are disengaged, pull the contact block straight off.

    INSTALLTo attach, align tabs (as shown) and gentlysnap top, then bottom. Be sure to hear BOTHtabs snap into place. (Can be reversed ifwiring comes from the top of the box.)

  • - 6 -

    ATTACH POWER FOR LED (IF DESIRED)(See drawing)

    NOTELED connection: The polarity shown is factory installed. LED ispolarity sensitive. If LED does not light, switch positive and negativewiring or remove LED and rotate 180. 24 volt is included and willoperate on 12 volts; however not as bright. 12 volt LEDs are alsoavailable.

    4

    TO SUPERVISED STATIONOR AUXILLARY DEVICE

    SW1

    SW2

    NC

    COM

    NO

    NC

    COM

    NO

    MAG LOCK

    MESSAGE LENS PCB

    1224VDC

    BUTTON LED

    NORMAL POSITION BUTTON ACTIVATED

    MAGNETIC LOCKBUTTON LAMP

    MESSAGE LAMP

    ONONOFF

    OFFOFFON

    NONC

    COM

    LED

    LED +

    SWITCH

    1SW

    ITCH 2

  • - 7 -

    CUSTOM LABELSTo create your own custom label, size to fit in .48h x 2.23warea as shown below. Also available online at: www.sti-usa.com/ublabel

    2.23 in.

    .48 in.

    MOUNT BUTTON ONTO ELECTRICAL BOX5

    6

    WARRANTYThree year guarantee against breakage of polycarbonate in normal use(one year on electro mechanical and electronic components).

    Electronic warranty form at www.sti-usa.com/wc14.

    BUTTON ACTIVATED

    M

    19085 #6 - 32 x 1 OVALHEAD MACHINE SCREW(2) PROVIDED

  • 2306 Airport Rd Waterford, MI 48327Phone: 248-673-9898 Fax: 248-673-1246

    [email protected] www.sti-usa.comSafety Technology International (Europe) Ltd.Unit 49G Pipers Road Park Farm Industrial Estate RedditchWorcestershire B98 0HU England Tel: 44 (0) 1527 520 999Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only)

    E-mail: [email protected] Web: www.sti-europe.comPrinted in USA Inst. Sht. UB-2 Button DEC2012

    CONTACT BLOCK SUB-UB-1C

    COLOR MATCH BACK BOX KIT SUB-71100A - COLOR (red, blue, green, white or yellow)

    CUSTOM LABEL APPLIED TO BLANK UB-1CL-COLOR MESSAGE PLATES (blue, green, white or yellow)

    24 VOLT LED WHITE (STANDARD) 10147 RED 10145 BLUE 10141 GREEN 10143

    12 VOLT LED RED 10144 BLUE 10140 GREEN 10142

    COVERS BOPPER STOPPER STI-6518 UNIVERSAL STOPPER STI-13000 Series STOPPER II STI-1100 Series

    ACCESSORIES

    DESCRIPTION PART #

    See website for complete cover details