Page 1: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Step by StepStreet Lighting Simulation with OSRAM LEDs in DIALux

Page 2: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 2SSL | Application Design Center Asia | V.Chen

Page

3

8

12

20

Agenda

• Introduction and Install of DIALux

• Import IES files of OSRAM LEDs

• Quick Street Planning Wizard with DIALux

• Step by Step – Design with OSRAM LEDs in DIALux

Page 3: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 3SSL | Application Design Center Asia | V.Chen

What is special about DIALux?

• DIALux - a planning software for your project presentation.

• Calculation: latest radiosity procedures, fast and always correct. • Results: Results can be printed out or transmitted as a pdf file. Each

view and each rendering can be saved as a .jpg file. • Interactive 3-D visualization: Simply move around the room. • Visualization: Use of textures and furniture for realistic rendering. • Photo realism: with integrated raytracing module. • False colours: False colours provide quantitative analysis of

complex geometries at a glance. • Movies: Walk through the photo realistic visualization of your light

planning and send the film to your customer via email. • Interaction: Import and export: .dwg and .dxf files can be imported

and exported with results after completion of the planning process. • DIALux Light: Easy to use, step-by-step lighting design.

Page 4: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 4SSL | Application Design Center Asia | V.Chen

Free Download DIALux from website

• Download the DIALux Setup (version DIALux 4.5.0.1 ) from homepage (www.DIAL.de or www.dialux.com) on your hard-disk.

• Language available– deutsch– english– français– italiano– español– 中文

• Download file size: about 250MB

www.DIAL.de or www.dialux.com

Page 5: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 5SSL | Application Design Center Asia | V.Chen

Online Update

• If you have already installed old version of DIALux, you could use “ online update” to newest version.

• In DIALux you will find a new menu named “Online”.• After selecting “Online Update…” DIALux automatically checks for newer versions of the

software and for new online PlugIns.• But it will take some time to finish update.

Page 6: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 6SSL | Application Design Center Asia | V.Chen

The DIALux User Interface • These three work areas enable effective and clearly arranged planning of lighting

installation with DIALux.

CAD-Window Task Pane

Project manager with Inspector

Page 7: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 7SSL | Application Design Center Asia | V.Chen

Page

Agenda

• Introduction and Install of DIALux

• Import IES files of OSRAM LEDs

• Quick Street Planning Wizard with DIALux

• Step by Step – Design with OSRAM LEDs in DIALux

3

8

12

20

Page 8: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 8SSL | Application Design Center Asia | V.Chen

.IES or .Idt files

• .IES or .Idt file describe the information of light distribution, luminous flux, and power.

• .IES or .Idt file are very small ( only about 10K) compared to ray data (about 200M).

• OSRAM OS provide both .IES (or .Idt) file and ray data of our LED products on website.

Page 9: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 9SSL | Application Design Center Asia | V.Chen

Download .IES file of OSRAM LED from website• http://www.ledlightforyou.com• Tools & Downloads >> Optical Tools

Page 10: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 10SSL | Application Design Center Asia | V.Chen

Import .IES file to DIALux

Page 11: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 11SSL | Application Design Center Asia | V.Chen

• Introduction and Install of DIALux

• Import IES files of OSRAM LEDs

• Quick Street Planning Wizard with DIALux

• Step by Step – Design with OSRAM LEDs in DIALux

Page

Agenda

3

8

12

20

Page 12: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 12SSL | Application Design Center Asia | V.Chen

Quick Street Planning Wizard

• you will find the wizards in the menu File >> Wizard

This wizard guides you through the quick planning for streets.

Page 13: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 13SSL | Application Design Center Asia | V.Chen

Street profile and illumination class

• Street profile

• Street name and maintenance factor are likewise inserted on this page.

• In the following window you can fix the individual or combined valuation fields for the street. In order to define photometric requirements for the street, select an illumination class for every valuation field.

Page 14: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 14SSL | Application Design Center Asia | V.Chen

Luminaire arrangement

• In the window Luminaire arrangement you can select a luminaire and place this in an arrangement. (You need to import the IES file of OSRAM LEDs first, otherwise you can only select the existing traditional luminaire in DIALux)

• You can optimize the arrangement parameters depending on the predefined photometric requirements.

Page 15: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 15SSL | Application Design Center Asia | V.Chen

Start Calculation

• Afterwards a final dialogue will appear automatically. If you activate the checkbox, the generated street will be calculated immediately.

• Click on the Finish button and your street project will be displayed.

Page 16: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 16SSL | Application Design Center Asia | V.Chen

Rotate 3D View

Rotate 3D View; left-click and move the mouse while holding the mouse button pressed.

Page 17: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 17SSL | Application Design Center Asia | V.Chen

3D light distribution DisplayHelp Rays for Luminaires / 3D light distribution Display / Show false colors in CAD

Page 18: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 18SSL | Application Design Center Asia | V.Chen

Show false colors in CAD

• Display the 3D rendering in a false colour rendering

• Easy to check the illuminance uniformity• Freely scaleable value ranges and definable

colour gradients

Page 19: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 19SSL | Application Design Center Asia | V.Chen

• Introduction and Install of DIALux

• Import IES files of OSRAM LEDs

• Quick Street Planning Wizard with DIALux

• Step by Step – Design with OSRAM LEDs in DIALux

Page

Agenda

3

8

12

20

Page 20: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 20SSL | Application Design Center Asia | V.Chen

Street profile, width, N of lanes, coating…

Step 1: Collecting road information

Information list before design:1. Street location and photos 2. Width of street3. N of lanes4. Coating material5. Existing mounting height or pole distance?

Decide the road classification and required Eav and Uo

according to street lighting standards

Information needed for lighting simulation

Page 21: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 21SSL | Application Design Center Asia | V.Chen

Step 2: Edit street in DIALux

Arrangement of street component according to the road information.

Page 22: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 22SSL | Application Design Center Asia | V.Chen

Step 3: Decide which LED (color bin and brightness group)• CCT: from 5000K-6500K (LW, LUW)• If need CCT from 4000K-5000K, can be mixed by LUW and LY.

Golden DRAGON PlusGolden DRAGON

with Oval Lens

No need of secondary optical design

Need lens or reflector

Higher brightness

Page 23: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 23SSL | Application Design Center Asia | V.Chen

Step 4: Change luminous flux

You can change the luminous flux and power here. It’s related to how many LEDs in one lamp.

Page 24: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 24SSL | Application Design Center Asia | V.Chen

Step 5: luminaire arrangement

0.4~0.5

W ≤ 6mN ≤2

Single row

Figure

0.5~0.80.5~0.8Uniformity

W ≥ 16mN ≥4

W ≥ 8mN ≥2Road information

Double row, opposing

Double row, with offsetLighting Class

Normal methods of luminaire arrangement

• Single row

• Double row, opposing

• Double row, with offset

Luminaire arrangement will be decided based on

• street profile

• requirements

• For LUW W5JM, Double row, opposing was recommended.

!Rules of thumb

Page 25: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 25SSL | Application Design Center Asia | V.Chen

Step 6: Optimize arrangement parameters

• (1) Mounting Height: 6m~10m• (2) Overhang: 1m~2m• (3) Boom Angle: 10°~15°• (4) Boom Length: 1m~3m• (5) Pole Distance

• These parameter will be optimized according to street profile to achieve best performance: Eav and Uo.

• If a certain Uo was required, the most economic mounting height and pole distance could be optimized.

• Lower distance, longer pole distance could save energy and pole cost.

Mounting Height

Overhang

Boom Angle

Boom Length

Lamp

(5)Pole Distance

Optimize arrangement parameters

Page 26: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 26SSL | Application Design Center Asia | V.Chen

Step 7: calculation and simulation

Not so uniform, need to be improved

Double row, opposing0.360.52248.617

Emin/EmaxUoEmax(lx)Emin(lx)Eav(lx)Change to double row, offset

Optimized results

0.720.83221619Emin/EmaxUoEmax(lx)Emin(lx)Eav(lx)

1

2

3

Page 27: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 27SSL | Application Design Center Asia | V.Chen

Step 8: Save the selected output as PDF file

Page 28: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 28SSL | Application Design Center Asia | V.Chen

Step 9: output design plan

Luminaire arrangement

Page 29: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux

Event / Title | December 17, 2008 | Page 29SSL | Application Design Center Asia | V.Chen

Step 10: output simulation results

0.720.83221619Emin/EmaxUoEmax(lx)Emin(lx)Eav(lx)

Isolines (E)

Table (E)

Main results

Page 30: Step by Step Street Lighting Simulation with OSRAM LEDs in DIALux