step by step street lighting simulation with osram leds in dialux
TRANSCRIPT
Step by StepStreet Lighting Simulation with OSRAM LEDs in DIALux
Event / Title | December 17, 2008 | Page 2SSL | Application Design Center Asia | V.Chen
Page
3
8
12
20
Agenda
• Introduction and Install of DIALux
• Import IES files of OSRAM LEDs
• Quick Street Planning Wizard with DIALux
• Step by Step – Design with OSRAM LEDs in DIALux
Event / Title | December 17, 2008 | Page 3SSL | Application Design Center Asia | V.Chen
What is special about DIALux?
• DIALux - a planning software for your project presentation.
• Calculation: latest radiosity procedures, fast and always correct. • Results: Results can be printed out or transmitted as a pdf file. Each
view and each rendering can be saved as a .jpg file. • Interactive 3-D visualization: Simply move around the room. • Visualization: Use of textures and furniture for realistic rendering. • Photo realism: with integrated raytracing module. • False colours: False colours provide quantitative analysis of
complex geometries at a glance. • Movies: Walk through the photo realistic visualization of your light
planning and send the film to your customer via email. • Interaction: Import and export: .dwg and .dxf files can be imported
and exported with results after completion of the planning process. • DIALux Light: Easy to use, step-by-step lighting design.
Event / Title | December 17, 2008 | Page 4SSL | Application Design Center Asia | V.Chen
Free Download DIALux from website
• Download the DIALux Setup (version DIALux 4.5.0.1 ) from homepage (www.DIAL.de or www.dialux.com) on your hard-disk.
• Language available– deutsch– english– français– italiano– español– 中文
• Download file size: about 250MB
www.DIAL.de or www.dialux.com
Event / Title | December 17, 2008 | Page 5SSL | Application Design Center Asia | V.Chen
Online Update
• If you have already installed old version of DIALux, you could use “ online update” to newest version.
• In DIALux you will find a new menu named “Online”.• After selecting “Online Update…” DIALux automatically checks for newer versions of the
software and for new online PlugIns.• But it will take some time to finish update.
Event / Title | December 17, 2008 | Page 6SSL | Application Design Center Asia | V.Chen
The DIALux User Interface • These three work areas enable effective and clearly arranged planning of lighting
installation with DIALux.
CAD-Window Task Pane
Project manager with Inspector
Event / Title | December 17, 2008 | Page 7SSL | Application Design Center Asia | V.Chen
Page
Agenda
• Introduction and Install of DIALux
• Import IES files of OSRAM LEDs
• Quick Street Planning Wizard with DIALux
• Step by Step – Design with OSRAM LEDs in DIALux
3
8
12
20
Event / Title | December 17, 2008 | Page 8SSL | Application Design Center Asia | V.Chen
.IES or .Idt files
• .IES or .Idt file describe the information of light distribution, luminous flux, and power.
• .IES or .Idt file are very small ( only about 10K) compared to ray data (about 200M).
• OSRAM OS provide both .IES (or .Idt) file and ray data of our LED products on website.
Event / Title | December 17, 2008 | Page 9SSL | Application Design Center Asia | V.Chen
Download .IES file of OSRAM LED from website• http://www.ledlightforyou.com• Tools & Downloads >> Optical Tools
Event / Title | December 17, 2008 | Page 10SSL | Application Design Center Asia | V.Chen
Import .IES file to DIALux
Event / Title | December 17, 2008 | Page 11SSL | Application Design Center Asia | V.Chen
• Introduction and Install of DIALux
• Import IES files of OSRAM LEDs
• Quick Street Planning Wizard with DIALux
• Step by Step – Design with OSRAM LEDs in DIALux
Page
Agenda
3
8
12
20
Event / Title | December 17, 2008 | Page 12SSL | Application Design Center Asia | V.Chen
Quick Street Planning Wizard
• you will find the wizards in the menu File >> Wizard
This wizard guides you through the quick planning for streets.
Event / Title | December 17, 2008 | Page 13SSL | Application Design Center Asia | V.Chen
Street profile and illumination class
• Street profile
• Street name and maintenance factor are likewise inserted on this page.
• In the following window you can fix the individual or combined valuation fields for the street. In order to define photometric requirements for the street, select an illumination class for every valuation field.
Event / Title | December 17, 2008 | Page 14SSL | Application Design Center Asia | V.Chen
Luminaire arrangement
• In the window Luminaire arrangement you can select a luminaire and place this in an arrangement. (You need to import the IES file of OSRAM LEDs first, otherwise you can only select the existing traditional luminaire in DIALux)
• You can optimize the arrangement parameters depending on the predefined photometric requirements.
Event / Title | December 17, 2008 | Page 15SSL | Application Design Center Asia | V.Chen
Start Calculation
• Afterwards a final dialogue will appear automatically. If you activate the checkbox, the generated street will be calculated immediately.
• Click on the Finish button and your street project will be displayed.
Event / Title | December 17, 2008 | Page 16SSL | Application Design Center Asia | V.Chen
Rotate 3D View
Rotate 3D View; left-click and move the mouse while holding the mouse button pressed.
Event / Title | December 17, 2008 | Page 17SSL | Application Design Center Asia | V.Chen
3D light distribution DisplayHelp Rays for Luminaires / 3D light distribution Display / Show false colors in CAD
Event / Title | December 17, 2008 | Page 18SSL | Application Design Center Asia | V.Chen
Show false colors in CAD
• Display the 3D rendering in a false colour rendering
• Easy to check the illuminance uniformity• Freely scaleable value ranges and definable
colour gradients
Event / Title | December 17, 2008 | Page 19SSL | Application Design Center Asia | V.Chen
• Introduction and Install of DIALux
• Import IES files of OSRAM LEDs
• Quick Street Planning Wizard with DIALux
• Step by Step – Design with OSRAM LEDs in DIALux
Page
Agenda
3
8
12
20
Event / Title | December 17, 2008 | Page 20SSL | Application Design Center Asia | V.Chen
Street profile, width, N of lanes, coating…
Step 1: Collecting road information
Information list before design:1. Street location and photos 2. Width of street3. N of lanes4. Coating material5. Existing mounting height or pole distance?
Decide the road classification and required Eav and Uo
according to street lighting standards
Information needed for lighting simulation
Event / Title | December 17, 2008 | Page 21SSL | Application Design Center Asia | V.Chen
Step 2: Edit street in DIALux
Arrangement of street component according to the road information.
Event / Title | December 17, 2008 | Page 22SSL | Application Design Center Asia | V.Chen
Step 3: Decide which LED (color bin and brightness group)• CCT: from 5000K-6500K (LW, LUW)• If need CCT from 4000K-5000K, can be mixed by LUW and LY.
Golden DRAGON PlusGolden DRAGON
with Oval Lens
No need of secondary optical design
Need lens or reflector
Higher brightness
Event / Title | December 17, 2008 | Page 23SSL | Application Design Center Asia | V.Chen
Step 4: Change luminous flux
You can change the luminous flux and power here. It’s related to how many LEDs in one lamp.
Event / Title | December 17, 2008 | Page 24SSL | Application Design Center Asia | V.Chen
Step 5: luminaire arrangement
0.4~0.5
W ≤ 6mN ≤2
Single row
Figure
0.5~0.80.5~0.8Uniformity
W ≥ 16mN ≥4
W ≥ 8mN ≥2Road information
Double row, opposing
Double row, with offsetLighting Class
Normal methods of luminaire arrangement
• Single row
• Double row, opposing
• Double row, with offset
Luminaire arrangement will be decided based on
• street profile
• requirements
• For LUW W5JM, Double row, opposing was recommended.
!Rules of thumb
Event / Title | December 17, 2008 | Page 25SSL | Application Design Center Asia | V.Chen
Step 6: Optimize arrangement parameters
• (1) Mounting Height: 6m~10m• (2) Overhang: 1m~2m• (3) Boom Angle: 10°~15°• (4) Boom Length: 1m~3m• (5) Pole Distance
• These parameter will be optimized according to street profile to achieve best performance: Eav and Uo.
• If a certain Uo was required, the most economic mounting height and pole distance could be optimized.
• Lower distance, longer pole distance could save energy and pole cost.
Mounting Height
Overhang
Boom Angle
Boom Length
Lamp
(5)Pole Distance
Optimize arrangement parameters
Event / Title | December 17, 2008 | Page 26SSL | Application Design Center Asia | V.Chen
Step 7: calculation and simulation
Not so uniform, need to be improved
Double row, opposing0.360.52248.617
Emin/EmaxUoEmax(lx)Emin(lx)Eav(lx)Change to double row, offset
Optimized results
0.720.83221619Emin/EmaxUoEmax(lx)Emin(lx)Eav(lx)
1
2
3
Event / Title | December 17, 2008 | Page 27SSL | Application Design Center Asia | V.Chen
Step 8: Save the selected output as PDF file
Event / Title | December 17, 2008 | Page 28SSL | Application Design Center Asia | V.Chen
Step 9: output design plan
Luminaire arrangement
Event / Title | December 17, 2008 | Page 29SSL | Application Design Center Asia | V.Chen
Step 10: output simulation results
0.720.83221619Emin/EmaxUoEmax(lx)Emin(lx)Eav(lx)
Isolines (E)
Table (E)
Main results
Thank you for your attention.