steel interchange - aisc home...'x"-bolts steel interchange steel interchange is an open...

2
'X"-bolts Steel Interchange Steel Interchange is an open forum for Modern Steel Construc- tion readers to exchange useful and practical professional ideas and information on all phases of steel building and bridge construc- tion. Opinions and suggestions are welcome on any subject cov- ered in this magazine. The opinions expressed in Steel Interchange do not necessarily represent an official position of the American Institute of Steel Con- struction, Inc. and have not been reviewed. It is recognized that the design of structures is within the scope and expertise of a compe- tent licensed structural engineer, architect or other licensed profes- sional for the application of principles to a particular structure. Question from February 2000: Are we dangerou sly kidding our selves wh en we specify "X" high-strength bolts? Th e allowable she ar stress es are increa s ed more than 40 % for thr e ad s exclud ed from the she ar plane. The installer of these bolts is an ironworker working man y feet above th e ground with a bolt bag filled with po ss ibl y man y varieties of bolts. How do es he know that the connec- tion he is working with at the moment requires "X" bolts? Ther e is also a very small tolerance for instaHing a bolt with the threads excluded from th e shear plane. For exampl e; a bolt with a lf2" shank (un thread ed portion under the bolt head) that is in s talled from the clip-angle side (5/16" thickness) to th e flang e of a W8x40 column flange has the thread s excluded. Tins same bolt installed form the column flang e s id e (9/16" thickne ss) doe s not ex clude th e threads. Anoth er aspect to consider is th e abilit y of th e structural steel inspector to verify that a bolted con- nection he observes after erection has in fact exclud- ed the thr e ads from the shear plan e sinc e the shank of the bolt is hidden from view. David E. Ayers, P.E. ESource Detailing Richmond, VA A STM A325 and A4 90 high- str ength bolt s are purposefully proportioned and produ ce d so that th e thr eads can be ex cluded from th e shear plane(s) when it is d esired to do so. Su ch variables as th e grip, number and placement of wa sher s, bolt length , thickn ess of the ply closest to th e nut, and dimen- sional tolerances all pl ay a part in proper design to exclude th e thr eads. For a complete di scu ssion of thi s, see "Specify ing Bolt Length for Hi gh-Strength Bolts" in th e 2,](1 quarter 1996 iss ue of th e AI SC Engineering Journal. Althou gh it is often po ss ibl e to ex clud e th e thr eads in specific cases with lesser pl y thic kn esses (see the abo ve referen ce d paper) , th e folJowing gen- eral rul es of thumb will always work. }< or 3/4-in. and 7/8-in. diameter high-strength bolts, a ply thic kn ess of 3/8 in. adjace nt to the nut will always exclude the If you have a question or problem that your fellow readers might help you to solve, please forward it to us . At the same time, feel free to respond to any of the questions that you have read here. Contact Steel Interchange at: Steel Interchange Attn : Keith A. Grubb, S.E., P.E. One East Wacker Dr. , Suite 3100 Chicago, IL 60601-2001 fax: 312/670-5403 email : [email protected] thr e ad s. For I-in . and 1 lI8-in. diameter hi gh - strength bolts, a ply thic kn ess of 112 in. adja ce nt to th e nut will alwa ys ex clud e th e thr e ad s. Th ese thic kn esses can be reduced to 114 in. and 3/8 in., r es pecti vel y, if an ASTM F436 washer is used und er the nut. As far as th e QA/Q C iss u es you raised, you can ensur e that thr eads will alwa ys be ex cluded from the she ar plan e without need for specific in spec tion quite simply by specifying all exterior pli es in the appropriate joints to meet th e minimum thicknesses listed abo ve . If you're willing to spend a little more time looking at grips and placement and number of wa sher s, you may be able to use lesser pl y thickn ess - es and th e information in th e abo ve referenced paper. For routine joint design s, I'd use strength valu es ass uming the thr eads will be included in th e shear plane ( ). With bolt bearin g, block shear ruptur e and shear rupture as limit stat es in bolted joints, you often won't get to the bolt shear strength for thr eads excluded (X) before something else controls. A final related, but se parat e item: A SIIASME B18.2.6 now contains all thr eading and dimensional standards relating to high-strength structural bolting products, including those for ASTM A32 5 and A490 bolts. The latest ve rsions of ASTM A325 and A490, ho weve r, s till referen ce th e o ld er sta nd a rd ANS IIAS ME B18.2.1, which co ve rs man y oth er applications than just high-strength bolts. With the variety of thr eading options cove red in ANSII AS ME B18.2. 1, th ere has been some confusion about w hat specific thr ea din g re quir eme nt s mu st be met for ASTM A325 and A490 bolts. Fortunatel y, bolt man- ufacturers know what th ey are suppo se d to be doing and produce ASTM A325 and A4 90 high- strength bolt s as th ey s hould-in acc ordan ce with ANS II AS ME B18. 2. 6. This inconsisten cy in refer- encing will sur ely be eliminated in the next avail- able re vi sions of ASTM A325 and A4 90, as well as th e AISC Specification and Manual. Charles J. Carter, S.E., P .E. American Institut e of Steel Cons truction Chicago,IL \1odc rn Steel Constru cti on / April 2000 / 9

Upload: others

Post on 02-Apr-2020

19 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Steel Interchange - AISC Home...'X"-bolts Steel Interchange Steel Interchange is an open forum for Modern Steel Construc tion readers to exchange useful and practical professional

'X"-bolts

Steel Interchange Steel Interchange is an open forum for Modern Steel Construc­

tion readers to exchange useful and practical professional ideas and information on all phases of steel building and bridge construc­tion . Opinions and suggestions are welcome on any subject cov­ered in this magazine.

The opinions expressed in Steel Interchange do not necessarily represent an official position of the American Institute of Steel Con­struction, Inc. and have not been reviewed. It is recognized that the design of structures is within the scope and expertise of a compe­tent licensed structural engineer, architect or other licensed profes­sional for the application of principles to a particular structure.

Question from February 2000:

Are we dangerously kidding ourselves when we specify "X" high-strength bolts? The allowable shear stresses are increased more than 40% for threads excluded from the shear plane. The installer of these bolts is an ironworker working many feet above the ground with a bolt bag filled with possibly many varieties of bolts. How does he know that the connec­tion he is working with at the moment requires "X" bolts?

There is also a very small tolerance for instaHing a bolt with the threads excluded from the shear plane. For example; a bolt with a lf2" shank (un threaded portion under the bolt h ead) that is installed from the clip-angle side (5/16" thickness) to the flange of a W8x40 column flange has the threads excluded. Tins same bolt installed form the column flange side (9/16" thickness) does not exclude the threads.

Another aspect to consider is the ability of the structural steel inspector to verify that a bolted con­nection he observes after erection has in fact exclud­ed the threads from the shear plane since the shank of the bolt is hidden from view.

David E. Ayers, P.E. ESource Detailing Richmond, VA

ASTM A325 and A490 high-strength bolts are purposefully proportioned and produced so that

the threads can be excluded from the shear plane(s) when it is desired to do so. Such variables as the grip, number and placement of washers, bolt length, thickness of the ply closest to the nut, and dimen­sional tolerances all play a part in proper design to exclude the threads. For a complete discussion of this, see "Specifying Bolt Length for High-Strength Bolts" in the 2,](1 qu arter 1996 issue of the AISC Engineering Journal.

Althou gh it is often possible to exclude th e threads in specific cases with lesser ply thicknesses (see the above referenced paper) , the folJowing gen­eral rules of thumb will always work. }<o r 3/4-in. and 7/8-in. diameter high-strength bolts, a ply thi ckness of 3/8 in. adjacent to the nut will always exclude the

If you have a question or problem that your fellow readers might help you to solve, please forward it to us. At the same time, feel free to respond to any of the questions that you have read here. Contact Steel Interchange at:

Steel Interchange Attn : Keith A. Grubb, S.E., P.E.

One East Wacker Dr. , Suite 3100 Chicago, IL 60601-2001

fax: 312/670-5403 email : [email protected]

threads. For I-in. and 1 lI8-in. diameter high ­strength bolts, a ply thickness of 112 in. adjacent to the nu t will alwa ys exclude th e threads. These thicknesses can be reduced to 114 in. and 3/8 in. , respectively, if an ASTM F436 washer is used under the nut.

As far as the QA/QC issues you raised, you can ensure that threads will always be excluded from the shear plane without need for specific inspection quite simply by specifying all exterior plies in the appropriate joints to meet the minimum thicknesses listed above. If you're willing to spend a little more time looking at grips and placement and number of washers, you may be able to use lesser ply thickness­es and the information in the abo ve refe renced paper.

For routine joint designs, I'd use strength values assuming the threads will be included in the shear plane ( ). With bolt bearing, block shear rupture and shear rupture as limit states in bolted joints, you often won't get to the bolt shear strength for threads excluded (X) before something else controls.

A final related, but separate item: A SIIASME B18.2.6 now contains all threading and dimensional standards relating to high-strength structural bolting products, including those for ASTM A325 and A490 bolts. The latest versions of ASTM A325 and A490, ho weve r , still r efer en ce th e older standard ANSIIAS ME B18.2.1 , which covers many other applications than just high-strength bolts. With the variety of threading options covered in ANSIIASME B18.2.1, there has been some confusion about what specific threading requirements must be met for ASTM A325 and A490 bolts. Fortunately, bolt man­ufacturers know what they are supposed to be doing and produce ASTM A325 and A490 high-strength bolts as they should-in accordance with ANSIIASME B18.2.6. This inconsistency in refer­encing will surely be eliminated in the next avail­able revisions of ASTM A325 and A490, as well as the AISC Specification and Manual.

Charles J. Carter, S.E., P .E. American Institute of Steel Construction Chicago,IL

\1odcrn Steel Constru ction / April 2000 / 9

Page 2: Steel Interchange - AISC Home...'X"-bolts Steel Interchange Steel Interchange is an open forum for Modern Steel Construc tion readers to exchange useful and practical professional

Girts, double angle connections

Steel Interchange Question from February 2000:

Girts are typically designed to support the vertical tributary area weight of siding for each girt level as well as the horizontal (component and cladding) tributary area wind pressure for each girt member.

Considering that siding is necessarily erected from the base upward and that the diaphragm arching effect of the siding would certainly bridge between columns and load them directly, why does it make any sense to consider channel girts to eccentrically support siding wei~ht on one flange? Suppose no sag rods are used'?

James G. Brooks, P .E. OnBoard Engineering Newark, DE

Th e load components on girts in thc vertical direction consist of the dead load of the girt and

siding. The dead load component of the girt passes through its centroid. However, the siding weight component does not pass through the centroid of the girts since the siding is attached to the outside flan ge. As a result, the outside flanges of the girts are eccentri cally loaded by the siding.

With this in mind, most of the channel girt's sec­tion oHers little resistance to bending about its weak axis, therefore the moment of inertia of the outside flange alone (approximately one half total I y) is used to compute stresses for weak axis bending. Since the sag rods only provide lateral support for the flange in the weak axis, they may be used to deter­mine the unbraeed length of the girts for weak-axis bending. In the absence of sag rods, the distance between columns becomes the girt's unbraced length for bending in the weak axis.

Sam Babatunde, P.E. Engineering Dynamics & Associates Edgewood, PA

Via email:

Table 9-3 and its accompanying paragraph (page 9-16) in the LRFD Manual of Steel Con­struction, 2 nd ed., Volume II, requires that for knife connections the leg of the clip angle weld­ed to the supporting member be 4" (with reduc­tion to 3 112" or 3" in some cases). If the con­nection is to be used on a column with a flange width of less than 8", can the clip be reduced to have a 2 112" leg welded to the supporting mem-

10 / \1 odern Sleel Construclion / April 2000

bel' without affecting its rated capacity in Table 9-3? The tables in the CISC Handbook are based on similar size angles.

Lome Hyatt Lambton Metal Works Ltd. Ontario, Canada

The strength of the connection would not change with a r educed angle leg dimension, but the

flexibility of the connection will change. The double angle connection is supposed to accommodate the end-rotation of the simple beam through flexing of the angle legs. The smaller you make the angle leg, the thinner you 'll have to make the angles to ensure flexibility.

I suggest you confirm with the engineer that the combination of reduced angle leg dimension and thickness will bc acceptable for this case. If you or they want to put some numbers on the acceptability of the combination, take a look at the calculations that are outlined for tee connections on page 9-170 of the AISC LRFD Manual, 2 nd ed., Volume H . Those same calculations can be applied to double angles to determine if the combination of thickness and angle leg lIimension is acceptable.

Charles]. Carter, S.E., P.E. American Institute of Steel Construction Chicago,IL