stax disposable depth filtersg-eitan.com/pdf/active pharmaceutical ingredients... · minimal...
TRANSCRIPT
![Page 1: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/1.jpg)
USD 2758
Stax™ Disposable Depth FiltersFeaturing Seitz® AKS Activated Carbon Media
![Page 2: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/2.jpg)
Highest Efficiency in Adsorption and Design
2
PAC Process AKS Process ImprovementsComplex multiple steps Streamlined single step Faster process
Better yieldsReduced labor
Powder addition Flow through single pass Better adsorptionand mixing Improved yields
Faster process
Carbon powder No upstream carbon No cleaningcontamination distributed No/trace carbon Minimalthroughout process plant downstream of module downstream
filtration
Dusty, difficult to handle No dust Improved health and safety
![Page 3: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/3.jpg)
3
The Stax System Design Provides Simple and Intuitive Operation
Complete Flexibility in Process Design
Stax AKS Systems
Features BenefitsNo housing Easier to use and manipulate while
eliminating operator safety issues
Completely disposable Eliminates need for cleaning and cleaning validation
Small footprint Enables use in close proximity to other equipment and reduces cost to install
Intuitive design Reduces operator training and increases time to acceptance
Encapsulated design Reduces operator exposure to potential biohazards
Low hold-up volume Greater product recovery and lower post use rinse volume required than traditional modules and housings
Combining the high efficiency SeitzAKS media grades with the Stax capsule represents a milestone inminimal handling of activated carbon.
![Page 4: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/4.jpg)
4
Seitz AKS Filter Media
Typical Molecular W eight Media Grade Efficiency Characteristics of Target ContaminantsAKS 1 Ultra high efficiency 400 – 1500 Daltons
AKS 2 Ultra high efficiency 400 – 1000 Daltons
AKS 5 High efficiency 200 – 400 Daltons
AKS 6 High efficiency 400 – 1500 Daltons
AKS 7 Ultra high efficiency 400 – 1500 Daltons
AKS 8 High efficiency 400 – 1000 Daltons
AKS 9 High efficiency 400 – 1000 Daltons
![Page 5: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/5.jpg)
5
Technical Information
Configuration for Media Grade Media Code Stax AKS Capsule Amount of PAC Present / Stax Capsule in Kg Media Area / Stax AKS Capsule in m²AKS 1 XAK1 406 1.45 1.40
AKS 2 XAK2 406 1.45 1.40
AKS 5 XAK5 407 1.05 1.62
AKS 6 XAK6 407 1.30 1.62
AKS 7 XAK7 406 1.45 1.40
AKS 8 XAK8 407 1.30 1.62
AKS 9 XAK9 407 1.30 1.62
Typical Endotoxin Level Media Grade Typical Ash Content in % (in EU/mL)AKS 1 < 3 < 0.12
AKS 2 < 4 < 0.12
AKS 5 < 1 < 0.06
AKS 6 < 3 < 0.06
AKS 7 < 3 < 0.12
AKS 8 < 2 < 0.12
AKS 9 < 2 < 0.12
Capsule Footprint Capsule WeightCapsule Size Diameter Height Dry Wet* Large 442 mm 128.8 mm 7-7.5 Kg < 13 Kg
(17.4 in.) (5.1 in.)
![Page 6: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/6.jpg)
6
Technical Information
Media Cellulose base and PAC
Capsule shell Glass filled polypropylene
Filter element Polypropylene
Gaskets Silicone
Maximum operating temperature 60 °C
Maximum operating pressure 3.5 bar at 25 °C1.0 bar at 60 °C
Maximum differential pressure 2.5 bar at 25 °C – forward direction
Hot water sanitization 80 °C at 1 bar for 1 h
Post use caustic treatment 1 M NaOH at 3.5 bar for 1 h at 25 °C
Capsule part number Media batch numberlaser engraved with Internal sales order number
Unique serial number
![Page 7: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/7.jpg)
7
Stax Chassis Information
Footprint SizeChassis Model Height Length WidthSXLSC02 1018 mm (40.0 in.) 516 mm (20.3 in.) 516 mm (20.3 in.)
SXLSC02W 1059 mm (41.7 in.) 591 mm (23.2 in.) 560 mm (22.0 in.)
SXPSC05P 1241 mm (48.9 in.) 610 mm (24.0 in.) 610 mm (24.0 in.)
SXPSC05W 1312 mm (51.6 in.) 1150 mm (45.3 in.) 800 mm (31.5 in.)
SXPSC10P 1864 mm (73.4 in.) 610 mm (24.0 in.) 610 mm (24.0 in.)
SXPSC10W 1935 mm (76.2 in.) 1150 mm (45.3 in.) 800 mm (31.5 in.)
Number of Stax AKS CapsulesChassis Model Weight Minimum MaximumSXLSC02 75 Kg 1 2
SXLSC02W 75 Kg 1 2
SXPSC05P 190 Kg 1 5
SXPSC05W 192 Kg 1 5
SXPSC10P 238 Kg 1 10
SXPSC10W 240 Kg 1 10
304/1.4301 Stainless Steel 1.2 m / 64 in Ra (typical) Electro-polish
Design Basis
Ordering Information
Part Number DescriptionSXLXAK1406SP Stax capsule with AKS1 media
SXLXAK2406SP Stax capsule with AKS2 media
SXLXAK5407SP Stax capsule with AKS5 media
SXLXAK6407SP Stax capsule with AKS6 media
SXLXAK7406SP Stax capsule with AKS7 media
SXLXAK8407SP Stax capsule with AKS8 media
SXLXAK9407SP Stax capsule with AKS9 media
Part Number DescriptionSXLSC02 Pilot scale without castors
SXLSC02W Pilot scale with castors
SXPSC05P 5 high process scale without castors
SXPSC05W 5 high process scale with castors
SXPSC10P 10 high process scale without castors
SXPSC10W 10 high process scale with castors
Part Number DescriptionSXBBM400SP Bottom in – Bottom out
SXTBM400SP Bottom in – Top out
![Page 8: Stax Disposable Depth Filtersg-eitan.com/pdf/Active Pharmaceutical Ingredients... · minimal handling of activated carbon. ... Seitz AKS Filter Media Typical Molecular Weight Media](https://reader034.vdocuments.mx/reader034/viewer/2022042518/5f776757aeac7e65eb702fa7/html5/thumbnails/8.jpg)
Europe
International Offices
© 2011, Pall Corporation. Pall, , Seitz, and Stax are trademarksof Pall Corporation. ® indicates a trademark registered in the USA. Filtration. Separation. Solution. is aservice mark of Pall Corporation.
Visit us on the Web at www.pall.com/biopharmE-mail us at [email protected]
Europe
United States
International Offices
© 2011, Pall Corporation. Pall, , Seitz, and Stax are trademarksof Pall Corporation. ® indicates a trademark registered in the USA.Filtration. Separation. Solution. is a service mark of Pall Corporation.
Visit us on the Web at www.pall.com/biopharmE-mail us at [email protected]