status of de/dx calibration
DESCRIPTION
Status of dE/dx Calibration. Yuri Fisyak October 17, 2002. Outlook. Why ? What ? Where ? Conclusions. Why ?. Last calibration was done in March, 2002: σ (dE/dx)/(dE/dx) = 8.2% for 76 cm track STAR CDR (p. 4C-33) σ (dE/dx)/(dE/dx) = 0.47 N -0.46 (Ph) -0.32 , P = 1atm - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/1.jpg)
Status of dE/dx Calibration
Yuri FisyakOctober 17, 2002
![Page 2: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/2.jpg)
Outlook
• Why ?• What ?• Where ?• Conclusions
![Page 3: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/3.jpg)
Why ?
• Last calibration was done in March, 2002:– σ(dE/dx)/(dE/dx) = 8.2% for 76 cm track– STAR CDR (p. 4C-33)
• σ(dE/dx)/(dE/dx) = 0.47 N-0.46(Ph)-0.32, P = 1atm• σInner = 14.3%, h = 1.15 cm, N = 12;• σOuter = 7.7%, h = 1.95 cm, N = 32;• σ = 6.8% for 76 cm track in TPC
– H.Bichsel simulation: • σ = 7.3 % for 11 * 1.2 cm + 31 * 2.0 cm
– I am not happy that ~1% is missing
![Page 4: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/4.jpg)
Why (cont.) ?• Comparison new and old tcl• H.Bichsel’s calculations reproduce data only
qualitatively. Is this due to calibration procedure ?• H.Bichsel claims that we have non linearity in dE
measurement. Can we check this ?• Can dE/dx calibration be done in one pass? Can we
move it into fast online ?
![Page 5: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/5.jpg)
What does calibration include?• Applying pad correction obtained from pulser data (Fabrice did this and I will not talk about)• For good clusters (used in fit, no overlaps) • For good global tracks (No. fit points ≥ 30, Track length in TPC > 40 cm)• Z =log[(dE/dx)measured/(dE/dx)predicted for π]
•Fit Z-distribution with Gauss(μ,σ) + pol3 in +/-3σ range. It is supposed that we have ~80% π and μ corresponds to π.
•μ should not depend on
•Time, Pressure
•Sector, row
•Drift distance
•…
![Page 6: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/6.jpg)
What does prediction mean ?
0.45 GeV/c
•Hans Bichsel made presentation about his model during the last collaboration meeting. He is preparing STAR TN on this subject.
•PAI model (Photo Absorption model for Ionization energy loss, V.Grishin V.Ermilova,S.Kotelnikov, NIM A309(1991) 476) gives the same predictions but PAI simulation program (provided by P.Nevski) has problem at low β (it was not tuned for this range). For this reason I will use Bichsel’s calculations.
![Page 7: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/7.jpg)
9.6% @ 76 cm
Resolution before calibration
![Page 8: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/8.jpg)
What does March calibration mean?
• March calibration included:– The same procedure as for Year 1 data– As prediction it was used Sirrf– Calibration was done for all tracks (no restriction on
momentum)– Time dependence : overall gain correction factor each
few hours (1-4)– Sector and pad row correction– Drift distance correction– Result : σ = 9.6 % → σ = 8.2 %
![Page 9: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/9.jpg)
Red – 40% truncation
Green – 30% truncation
Black - fit
8.2% @ 76 cm
![Page 10: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/10.jpg)
9.7%
9.9% =>9.8% after setting convolution flag
New tcl a little bit worse than old one
![Page 11: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/11.jpg)
New calibration• Calibration is based on tracks with 0.4 < p < 0.5 GeV/c
(~MIP for pions: βγ = p/m = 4).• Calibration has been done for new tcl only.• As prediction it was used Bichsel’s calculation with dx
dependence (see next slide) i.e. Z =log[(dE/dx)measured/(dE/dx)predicted for π(βγ,dx)]
• This calibration gives σ = 8.8% (instead of 8.2% obtained in March because it was done only for 0.4<p<0.5GeV/c but resolution is obtained for all momenta).
![Page 12: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/12.jpg)
![Page 13: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/13.jpg)
Calibration done for p in [0.4,0.5] GeV/c with new tcl
σ = 8.8% @76 cm
![Page 14: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/14.jpg)
Check of ADC nonlinearityFor uniquely identified tracks:• σ < 15% and• v = log[(dEdx)/(dE/dx)J],
where J = [e,π,K,p,d]• |v| < 3σ for only J, and • |(dE/dx)J - (dE/dx)k| >5σ, for
J≠KPlot predicted dE versus
measured dEInner
Outer
It is seen clean nonlinearity besides saturation (with offset ~1keV).
It is not clear what is origin for this nonlinearity:
•ADC, it has to be checked with pulser data
•tcl ? due to threshold effects?
![Page 15: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/15.jpg)
Time dependenceGain variation versus time. ~5%
Pressure variation versus time
Oxygen concentration variation versus time
![Page 16: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/16.jpg)
Time dependence (cont.)
• Drift distance correction: e+AdO
where A = 1.75e-6 (1/cm/ppmO2),
provided by A.Lebedev (ALEPH data) d – drift distance (cm), O – concentration of Oxygen (ppm)
![Page 17: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/17.jpg)
Pressure
•Both Drift distance and Pressure correction allow to remove time dependence.
•TPC Gain Monitor cannot be used (at least now) because its results depend on magnetic field.
![Page 18: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/18.jpg)
< 1 %
![Page 19: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/19.jpg)
After pad level correction from pulser calibration it still exists gain variation versus sector and row
![Page 20: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/20.jpg)
Dependence of gain correction versus drift distance (after accounting absorption) for Inner rows has opposite behavior with respect to expected. ADC nonlinearity is overcorrected !?
![Page 21: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/21.jpg)
7.4% @ 76 cm
![Page 22: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/22.jpg)
For both + and -
![Page 23: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/23.jpg)
For positive only
![Page 24: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/24.jpg)
Negative only
![Page 25: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/25.jpg)
Bichsel shapes
Inner
fit by φ(μ+(1+σ)z), where φ(z) is Bichsel shape and z = log(dE/dEmost probable);
![Page 26: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/26.jpg)
Outer
Both inner and outer rows are reasonably well described by Bichsel shape.
![Page 27: Status of dE/dx Calibration](https://reader033.vdocuments.mx/reader033/viewer/2022052302/568144db550346895db1a8b7/html5/thumbnails/27.jpg)
Conclusions
• In sense of dE/dx old and new tcl give comparable results.• It is observed significant nonlinearity in dE with respect to H.Bichsel
calculation.• Accounting this nonlinearity allows to improve resolution by ~1%
(8.2%=>7.4%) which is matched with our expectation.• To understand the nonlinearity is necessary to get pulser data with
different signal amplitudes.• If the linearity will be understood than it will be possible to move
dE/dx calibration in fast online.• With new calibration the Bichsel shape of dE/dx distribution
describes data pretty well. Thus we can claim that model calculations gives quantitative agreement with data.