statistic-total.mcel novo ber test.2011!07!23.20!08!25

9
Document Information Started: 2011-07-23 20:08:24, Stopped: 2011-07-24 13:51:09, Duration: 0 - 17:42:45 Description: GUAVA test do Sinal Comment Customer: Project/description: Operator: Notes: mcel novo BER test, Total: 2011-07-23 20:08:25 Document Information 1

Upload: peter-de-sa

Post on 06-Mar-2015

28 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

Document InformationStarted: 2011−07−23 20:08:24, Stopped: 2011−07−24 13:51:09, Duration: 0 − 17:42:45Description: GUAVA test do Sinal

Comment

Customer:

Project/description:

Operator:

Notes:

mcel novo BER test, Total: 2011−07−23 20:08:25

Document Information 1

Page 2: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

2Mbps Alarms & ErrorsStarted: 2011−07−23 20:08:24, Stopped: 2011−07−24 13:51:09, Duration: 0 − 17:42:45Description: GUAVA test do Sinal

Alarms RxA (Seconds, Ratio) RxB (Seconds, Ratio)

No Signal 0 0

AIS 34 0.000533

No Frame 0 0

No CRC4 MF

No Flag

Message Impaired

Distant Alarm 0 0

No Sync 0 0

No CAS MF

Link unavailable

Distant MF

mcel novo BER test, Total: 2011−07−23 20:08:25

2Mbps Alarms & Errors 2

Page 3: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

Errors RxA (Count, Ratio) RxB (Count, Ratio)

FAS 0 0

Pattern 0 0

CRC4

E−Bit

Code 0 0

Pattern Slips 0

Frame Slips 0

Rx Frequency RxA(UI, ppm) RxB(UI, ppm)

Deviation 212 0.00162

Difference RxA−RxB

mcel novo BER test, Total: 2011−07−23 20:08:25

2Mbps Alarms & Errors 3

Page 4: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

2Mbps − G.826Started: 2011−07−23 20:08:24, Stopped: 2011−07−24 13:51:09, Duration: 0 − 17:42:45Description: GUAVA test do Sinal

FAS Errors RxA ( Count, Ratio[ % ] ) RxB ( Count, Ratio[ % ] )

ES 0 0

SES 0 0

BBE 0 0

ALS 0 0

UAT 34 0.0533

AVT 63726 99.9

EFS 6.37e+04 100

Pattern Errors RxA ( Count, Ratio[ % ] ) RxB ( Count, Ratio[ % ] )

ES 0 0

SES 0 0

BBE 0 0

ALS 0 0

UAT 34 0.0533

AVT 63726 99.9

EFS 6.37e+04 100

mcel novo BER test, Total: 2011−07−23 20:08:25

2Mbps − G.826 4

Page 5: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

CRC4 Errors RxA ( Count, Ratio[ % ] ) RxB ( Count, Ratio[ % ] )

ES

SES

BBE

ALS

UAT

AVT

EFS

E−bit Errors RxA ( Count, Ratio[ % ] ) RxB ( Count, Ratio[ % ] )

ES

SES

BBE

ALS

UAT

AVT

EFS

mcel novo BER test, Total: 2011−07−23 20:08:25

2Mbps − G.826 5

Page 6: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

2Mbps BERTStarted: 2011−07−23 20:08:24, Stopped: 2011−07−24 13:51:09, Duration: 0 − 17:42:45Description: GUAVA test do Sinal

Alarms/Errors RxA (Count, Ratio) RxB (Count, Ratio)

Pattern Block Errors 0 0

Pattern Slip 0

Sequence Errors

Pattern Bit Count 4.08e+09

No Signal−seconds 0 0

AIS−seconds 34 0.000533

No Sync−seconds 0 0

G.826 RxA (Count, Ratio[%]) RxB (Count, Ratio[%])

ES 0 0

SES 0 0

BBE 0 0

ALS 0 0

UAT 34 0.0533

AVT 63726 99.9

EFS 6.37e+04 100

mcel novo BER test, Total: 2011−07−23 20:08:25

2Mbps BERT 6

Page 7: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

Instrument SetupStarted: 2011−07−23 20:08:24, Stopped: 2011−07−24 13:51:09, Duration: 0 − 17:42:45Description: GUAVA test do Sinal

Printing Setup

Receiver A Enabled

Receiver B Enabled

Report Content Selected Interval

Measurement Setup

Instrument serial number 846380004

Software version 3.71

Software date 2009−07−06 13:32:57

Measurement name mcel novo BER test

Measurement start time 2011−07−23 20:08:24

Measurement stop time 2011−07−24 13:51:09

Interval duration 5 s

2Mbps Evaluations RxA RxB

Performance parameters G.826 G.826

Evalution type Any error or alarm Any error or alarm

Pass limits <= ... and > ... , HR% = ... <= ... and > ... , HR% = ...

2Mbps Receivers RxA RxB

Reception On Off

Connector Unbalanced ...

Input Mode Terminate ...

Input Sensitivity Full ...

Line Code HDB3 ...

PCM Frame On ...

CRC4 Off ...

E−bits ... ...

Pattern Type PRBS 11 ...

mcel novo BER test, Total: 2011−07−23 20:08:25

Instrument Setup 7

Page 8: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

Pattern Inverse Normal ...

Pattern Time Slots ...

User Pattern[16] ... ...

Subchannel Content Off ...

Channel Time Slots ... ...

Subchannel ... ...

Audio Off ...

Audio Time Slots ... ...

Audio Subchannel ... ...

Output Clock Off ...

2Mbps Transmitters TxA TxB

Transmission On Off

Connector Unbalanced ...

Drop and Insert Off ...

Clock Source Internal ...

Clock Offset 0 ppm ...

Line Code HDB3 ...

PCM Frame On ...

CRC4 Off ...

Sa−Bits ... ...

Sa−Bits D&I ... ...

Pattern Type PRBS 11 ...

Pattern Invert Normal ...

Pattern Time Slots ...

User Patter [16] ... ...

Unused Time Slots 1010101 ...

Channel Contents Off ...

Sub Channel Frame Type ... ...

Channel Time Slot ... ...

SubChannel ... ...

mcel novo BER test, Total: 2011−07−23 20:08:25

Instrument Setup 8

Page 9: Statistic-Total.mcel Novo BER Test.2011!07!23.20!08!25

Tone Frequency ... ...

Tone Level ... ...

CAS Off ...

CAS Channel ... ...

CAS Select Ch. Bits ... ...

CAS Other Ch. Bits ... ...

Alarms No Alarm ...

Error Insertion Off ...

Error Destination ... ...

Error Burst Length ... ...

V−Series/Codir. Interface

Selection None

mcel novo BER test, Total: 2011−07−23 20:08:25

Instrument Setup 9