standard drawing 4083b cattle underpass road cross section and guard fence treatment
DESCRIPTION
cattel underpassTRANSCRIPT
C
DISCLAIMER
(REFER NOTE 4)
OR FLATTER
SLOPE 10 TO 1
(REFER NOTE 4)
OR FLATTER
SLOPE 10 TO 1
BCTA TERMINAL
SPACING1m POST
5m
T.T
SPACING1m POST
5m
5m
40m RADIUS
SPACING1m POST
SINGLE CELL PLAN
UNDERPASS
C 06/14
SAFETY BARRIERS SHALL BE APPROVED PRODUCTS BY THE RELEVANT LOCAL ROAD AUTHORITY.2.
ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE SHOWN.1.
APPROVED TERMINAL
LOCAL ROAD AUTHORITY
APPROVED TERMINAL
LOCAL ROAD AUTHORITY
APPROVED TERMINAL
LOCAL ROAD AUTHORITY
CELL PLAN AND CLASS A-C CROSS SECTIONS
ADDED DISCLAIMER AND NOTES 5-8, REMOVED TWIN
THIS DRAWING IS INTERIM ACCEPTED UNTIL FURTHER REVIEW
MIN 15m WHEN
D.C.
MIN 15m WHEN USED WITH A 5.1m
USED WITH A 5.1m BCTA TERMINAL
BCTA TERMINAL
MIN 15m WHEN USED WITH A 5.1m
LOCAL ROAD SINGLE LANE WITH SEAL WIDTH 5m
LOCAL ROAD WITH SEAL WIDTH 5m
MINIMUM CLEAR WIDTH BETWEEN BARRIERS
CATTLE UNDERPASS GUIDELINES
CROSS-SECTIONS
LOCAL ROAD ONE LANE TWO WAY
PLAN
CLEARANCE TRAFFIC LANE CLEARANCE
CLEARANCE TRAFFIC LANES CLEARANCE
DIRECTION OF TRAFFIC
DIRECTION OF TRAFFIC
(SEE NOTE 5)
OR FLATTER
SLOPE 10 TO 1
40m RADIUS RAD6m
UNDERPASS
(REFER SD 3544)
4m TRAILING TERMINAL
UNDERPASS
C
SHOULDER
DIRECTION OF TRAFFIC
SHOULDER
RADIUS40m
1000
126
2.5m2.5m
75
300
1000
126
2.5m 2.5m
75
300
5m
5m
L
UNDERPASS
C
L
5m
2.0m 2.0m
330
300
75
2.5m2.5m
1000
126
2.0m 2.0m3.3m 3.3m
10.6m
2.0m 2.0m
8.0m
4.0m
NOT TO SCALE
Vic
Roads
Dra
win
g
No.
ROAD SAFETY BARRIERS
CATTLE UNDERPASS
CROSS SECTION AND GUARD FENCE TREATMENT
SD 4083
OUTSIDE THE CLEAR ZONE FOR THE OPPOSING TRAFFIC DIRECTION.
TRAILING TERMINALS AS SPECIFIED SHALL ONLY BE USED WHERE LOCATED 8.
DIRECTIONS.
ON THE SINGLE CELL PLAN WILL APPLY FROM THE MIDDLE IN BOTH
THE OUTER CELL. E.G. FOR A TWIN CELL UNDERPASS, THE LENGTHS SHOWN
LENGTHS OF GUARD FENCE SHOWN SHALL BE MEASURED FROM THE BACK OF 7.
ARE MOST EFFECTIVE FOR THE REQUIRED HAZARD.
DRIVEABLE TERRAIN, TO ENSURE THAT LENGTHS OF GUARD FENCE SHOWN
THE PREFERRED BARRIER OFFSET IS CLOSE TO THE HAZARD OR LIMIT OF 6.
PART 6, SECTION 4.2.2.
TO FLATTER THAN 3:1 SO THEY ARE TRAVERSABLE BY CARS. REFER AGRD
WHERE POSSIBLE, BATTERS OUTSIDE THE CLEAR ZONE SHOULD BE SHAPED 5.
OF VERGE TO THE GUARD FENCE.
IDEALLY, THIS FLAT AREA SHOULD COVER THE FULL WIDTH FROM THE EDGE
STEEPER THAN 10 to 1 SHALL BE PROVIDED IN FRONT OF GUARD FENCE.
AN OBSTACLE-FREE AREA OF AT LEAST 2m WIDE WITH A SLOPE NOT 4.
RURAL CARRIAGEWAY ELEMENTS.
REFER VICROADS SUPPLEMENT TO AGRD PART 3, TABLE V4.2 WIDTHS OF 3.
IF THE VERGE IS NARROW AND THE BATTER 5:1, REFER TO SD 3521.2.
CONSULTATION WITH THE RELEVANT ROAD AUTHORITY. E.G. COUNCIL.
CONDITIONS. APPLICABLE CROSS SECTION TO BE DETERMINED IN
THE ABOVE CROSS SECTIONS MAY INCREASE DUE TO INDIVIDUAL SITE 1.
NOTES:
1. GUARD FENCE TREATMENTS SHOWN IN THIS DRAWING SHALL ONLY BE USED ON LOCAL ROADS WITH LESS THAN 500
VEHICLES PER DAY (VPD) AND WITH APPROVAL FROM THE RESPONSIBLE LOCAL ROAD AUTHORITY.
2. DESIGNS AND INSTALLATION OF CATTLE UNDERPASS TREATMENTS ON VICROADS DECLARED ROADS SHALL BE IN
ACCORDANCE WITH AUSTROADS GUIDE TO ROAD DESIGN - PART 6, RELEVANT VICROADS SUPPLEMENTS AND VICROADS ROAD
DESIGN NOTE 06-04 - ACCEPTED SAFETY BARRIER PRODUCTS.
3. SITE SPECIFIC INFORMATION SHOULD ALWAYS BE CONSIDERED DURING DESIGN TO ESTABLISH THE RISK OF THE ROADSIDE
HAZARD AND THE ACCEPTABLE LEVEL OF RISK BY THE RESPONSIBLE ROAD AUTHORITY.
SEE NOTE 8
TRAFFIC DIRECTION.
ZONE FOR OPPOSING
BARRIER OUTSIDE CLEAR
720379
ISSUEAPPROVED
AMENDMENT
STANDARD DRAWING
REFERENCES AND NOTES:
ISSUE DATEAPP’D
FAX (03) 9811 8329
PHONE (03) 9811 8355
VICTORIA 3124
CAMBERWELL
3 PROSPECT HILL ROAD
SD NO.
SERVICES
TECHNICAL