standard drawing 4083b cattle underpass road cross section and guard fence treatment

1
C DISCLAIMER (REFER NOTE 4) OR FLATTER SLOPE 10 TO 1 (REFER NOTE 4) OR FLATTER SLOPE 10 TO 1 BC T A TE R M I NA L SPACING 1 m P O S T 5m T.T SPACING 1 m P O S T 5m 5m 40 m R A D I U S SP A C I NG 1m POST SINGLE CELL PLAN UNDERPASS C 06/14 SAFETY BARRIERS SHALL BE APPROVED PRODUCTS BY THE RELEVANT LOCAL ROAD AUTHORITY. 2. ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE SHOWN. 1. APPROVED TERMINAL LOCAL ROAD AUTHORITY APPROVED TERMINAL LOCAL ROAD AUTHORITY APPROVED TERMINAL LOCAL ROAD AUTHORITY CELL PLAN AND CLASS A-C CROSS SECTIONS ADDED DISCLAIMER AND NOTES 5-8, REMOVED TWIN THIS DRAWING IS INTERIM ACCEPTED UNTIL FURTHER REVIEW MIN 15 m W H E N D.C. M I N 15 m W H E N U S E D W I T H A 5 . 1 m U S E D W I T H A 5 . 1 m BC T A TE R M I NA L BC T A TE R M I NA L M I N 15 m W H E N U S E D W I T H A 5 . 1 m LOCAL ROAD SINGLE LANE WITH SEAL WIDTH 5m LOCAL ROAD WITH SEAL WIDTH 5m MINIMUM CLEAR WIDTH BETWEEN BARRIERS CATTLE UNDERPASS GUIDELINES CROSS-SECTIONS LOCAL ROAD ONE LANE TWO WAY PLAN CLEARANCE TRAFFIC LANE CLEARANCE CLEARANCE TRAFFIC LANES CLEARANCE DIRECTION OF TRAFFIC DIRECTION OF TRAFFIC (SEE NOTE 5) OR FLATTER SLOPE 10 TO 1 40 m R AD I U S R AD 6 m UNDERPASS (REFER SD 3544) 4m TRAILING TERMINAL UNDERPASS C SHOULDER DIRECTION OF TRAFFIC SHOULDER R AD I U S 40 m 1000 126 2.5m 2.5m 75 300 1000 126 2.5m 2.5m 75 300 5m 5m L UNDERPASS C L 5m 2.0m 2.0m 330 300 75 2.5m 2.5m 1000 126 2.0m 2.0m 3.3m 3.3m 10.6m 2.0m 2.0m 8.0m 4.0m NOT TO SCALE Vi c R o a d s Dr a wi ng No . ROAD SAFETY BARRIERS CATTLE UNDERPASS CROSS SECTION AND GUARD FENCE TREATMENT SD 4083 OUTSIDE THE CLEAR ZONE FOR THE OPPOSING TRAFFIC DIRECTION. TRAILING TERMINALS AS SPECIFIED SHALL ONLY BE USED WHERE LOCATED 8. DIRECTIONS. ON THE SINGLE CELL PLAN WILL APPLY FROM THE MIDDLE IN BOTH THE OUTER CELL. E.G. FOR A TWIN CELL UNDERPASS, THE LENGTHS SHOWN LENGTHS OF GUARD FENCE SHOWN SHALL BE MEASURED FROM THE BACK OF 7. ARE MOST EFFECTIVE FOR THE REQUIRED HAZARD. DRIVEABLE TERRAIN, TO ENSURE THAT LENGTHS OF GUARD FENCE SHOWN THE PREFERRED BARRIER OFFSET IS CLOSE TO THE HAZARD OR LIMIT OF 6. PART 6, SECTION 4.2.2. TO FLATTER THAN 3:1 SO THEY ARE TRAVERSABLE BY CARS. REFER AGRD WHERE POSSIBLE, BATTERS OUTSIDE THE CLEAR ZONE SHOULD BE SHAPED 5. OF VERGE TO THE GUARD FENCE. IDEALLY, THIS FLAT AREA SHOULD COVER THE FULL WIDTH FROM THE EDGE STEEPER THAN 10 to 1 SHALL BE PROVIDED IN FRONT OF GUARD FENCE. AN OBSTACLE-FREE AREA OF AT LEAST 2m WIDE WITH A SLOPE NOT 4. RURAL CARRIAGEWAY ELEMENTS. REFER VICROADS SUPPLEMENT TO AGRD PART 3, TABLE V4.2 WIDTHS OF 3. IF THE VERGE IS NARROW AND THE BATTER 5:1, REFER TO SD 3521. 2. CONSULTATION WITH THE RELEVANT ROAD AUTHORITY. E.G. COUNCIL. CONDITIONS. APPLICABLE CROSS SECTION TO BE DETERMINED IN THE ABOVE CROSS SECTIONS MAY INCREASE DUE TO INDIVIDUAL SITE 1. NOTES: 1. GUARD FENCE TREATMENTS SHOWN IN THIS DRAWING SHALL ONLY BE USED ON LOCAL ROADS WITH LESS THAN 500 VEHICLES PER DAY (VPD) AND WITH APPROVAL FROM THE RESPONSIBLE LOCAL ROAD AUTHORITY. 2. DESIGNS AND INSTALLATION OF CATTLE UNDERPASS TREATMENTS ON VICROADS DECLARED ROADS SHALL BE IN ACCORDANCE WITH AUSTROADS GUIDE TO ROAD DESIGN - PART 6, RELEVANT VICROADS SUPPLEMENTS AND VICROADS ROAD DESIGN NOTE 06-04 - ACCEPTED SAFETY BARRIER PRODUCTS. 3. SITE SPECIFIC INFORMATION SHOULD ALWAYS BE CONSIDERED DURING DESIGN TO ESTABLISH THE RISK OF THE ROADSIDE HAZARD AND THE ACCEPTABLE LEVEL OF RISK BY THE RESPONSIBLE ROAD AUTHORITY. SEE NOTE 8 TRAFFIC DIRECTION. ZONE FOR OPPOSING BARRIER OUTSIDE CLEAR 720379 ISSUE APPROVED AMENDMENT STANDARD DRAWING REFERENCES AND NOTES: ISSUE DATE APP’D FAX (03) 9811 8329 PHONE (03) 9811 8355 VICTORIA 3124 CAMBERWELL 3 PROSPECT HILL ROAD SD NO. SERVICES TECHNICAL

Upload: shravan38

Post on 26-Jan-2016

213 views

Category:

Documents


0 download

DESCRIPTION

cattel underpass

TRANSCRIPT

Page 1: Standard Drawing 4083B Cattle Underpass Road Cross Section and Guard Fence Treatment

C

DISCLAIMER

(REFER NOTE 4)

OR FLATTER

SLOPE 10 TO 1

(REFER NOTE 4)

OR FLATTER

SLOPE 10 TO 1

BCTA TERMINAL

SPACING1m POST

5m

T.T

SPACING1m POST

5m

5m

40m RADIUS

SPACING1m POST

SINGLE CELL PLAN

UNDERPASS

C 06/14

SAFETY BARRIERS SHALL BE APPROVED PRODUCTS BY THE RELEVANT LOCAL ROAD AUTHORITY.2.

ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE SHOWN.1.

APPROVED TERMINAL

LOCAL ROAD AUTHORITY

APPROVED TERMINAL

LOCAL ROAD AUTHORITY

APPROVED TERMINAL

LOCAL ROAD AUTHORITY

CELL PLAN AND CLASS A-C CROSS SECTIONS

ADDED DISCLAIMER AND NOTES 5-8, REMOVED TWIN

THIS DRAWING IS INTERIM ACCEPTED UNTIL FURTHER REVIEW

MIN 15m WHEN

D.C.

MIN 15m WHEN USED WITH A 5.1m

USED WITH A 5.1m BCTA TERMINAL

BCTA TERMINAL

MIN 15m WHEN USED WITH A 5.1m

LOCAL ROAD SINGLE LANE WITH SEAL WIDTH 5m

LOCAL ROAD WITH SEAL WIDTH 5m

MINIMUM CLEAR WIDTH BETWEEN BARRIERS

CATTLE UNDERPASS GUIDELINES

CROSS-SECTIONS

LOCAL ROAD ONE LANE TWO WAY

PLAN

CLEARANCE TRAFFIC LANE CLEARANCE

CLEARANCE TRAFFIC LANES CLEARANCE

DIRECTION OF TRAFFIC

DIRECTION OF TRAFFIC

(SEE NOTE 5)

OR FLATTER

SLOPE 10 TO 1

40m RADIUS RAD6m

UNDERPASS

(REFER SD 3544)

4m TRAILING TERMINAL

UNDERPASS

C

SHOULDER

DIRECTION OF TRAFFIC

SHOULDER

RADIUS40m

1000

126

2.5m2.5m

75

300

1000

126

2.5m 2.5m

75

300

5m

5m

L

UNDERPASS

C

L

5m

2.0m 2.0m

330

300

75

2.5m2.5m

1000

126

2.0m 2.0m3.3m 3.3m

10.6m

2.0m 2.0m

8.0m

4.0m

NOT TO SCALE

Vic

Roads

Dra

win

g

No.

ROAD SAFETY BARRIERS

CATTLE UNDERPASS

CROSS SECTION AND GUARD FENCE TREATMENT

SD 4083

OUTSIDE THE CLEAR ZONE FOR THE OPPOSING TRAFFIC DIRECTION.

TRAILING TERMINALS AS SPECIFIED SHALL ONLY BE USED WHERE LOCATED 8.

DIRECTIONS.

ON THE SINGLE CELL PLAN WILL APPLY FROM THE MIDDLE IN BOTH

THE OUTER CELL. E.G. FOR A TWIN CELL UNDERPASS, THE LENGTHS SHOWN

LENGTHS OF GUARD FENCE SHOWN SHALL BE MEASURED FROM THE BACK OF 7.

ARE MOST EFFECTIVE FOR THE REQUIRED HAZARD.

DRIVEABLE TERRAIN, TO ENSURE THAT LENGTHS OF GUARD FENCE SHOWN

THE PREFERRED BARRIER OFFSET IS CLOSE TO THE HAZARD OR LIMIT OF 6.

PART 6, SECTION 4.2.2.

TO FLATTER THAN 3:1 SO THEY ARE TRAVERSABLE BY CARS. REFER AGRD

WHERE POSSIBLE, BATTERS OUTSIDE THE CLEAR ZONE SHOULD BE SHAPED 5.

OF VERGE TO THE GUARD FENCE.

IDEALLY, THIS FLAT AREA SHOULD COVER THE FULL WIDTH FROM THE EDGE

STEEPER THAN 10 to 1 SHALL BE PROVIDED IN FRONT OF GUARD FENCE.

AN OBSTACLE-FREE AREA OF AT LEAST 2m WIDE WITH A SLOPE NOT 4.

RURAL CARRIAGEWAY ELEMENTS.

REFER VICROADS SUPPLEMENT TO AGRD PART 3, TABLE V4.2 WIDTHS OF 3.

IF THE VERGE IS NARROW AND THE BATTER 5:1, REFER TO SD 3521.2.

CONSULTATION WITH THE RELEVANT ROAD AUTHORITY. E.G. COUNCIL.

CONDITIONS. APPLICABLE CROSS SECTION TO BE DETERMINED IN

THE ABOVE CROSS SECTIONS MAY INCREASE DUE TO INDIVIDUAL SITE 1.

NOTES:

1. GUARD FENCE TREATMENTS SHOWN IN THIS DRAWING SHALL ONLY BE USED ON LOCAL ROADS WITH LESS THAN 500

VEHICLES PER DAY (VPD) AND WITH APPROVAL FROM THE RESPONSIBLE LOCAL ROAD AUTHORITY.

2. DESIGNS AND INSTALLATION OF CATTLE UNDERPASS TREATMENTS ON VICROADS DECLARED ROADS SHALL BE IN

ACCORDANCE WITH AUSTROADS GUIDE TO ROAD DESIGN - PART 6, RELEVANT VICROADS SUPPLEMENTS AND VICROADS ROAD

DESIGN NOTE 06-04 - ACCEPTED SAFETY BARRIER PRODUCTS.

3. SITE SPECIFIC INFORMATION SHOULD ALWAYS BE CONSIDERED DURING DESIGN TO ESTABLISH THE RISK OF THE ROADSIDE

HAZARD AND THE ACCEPTABLE LEVEL OF RISK BY THE RESPONSIBLE ROAD AUTHORITY.

SEE NOTE 8

TRAFFIC DIRECTION.

ZONE FOR OPPOSING

BARRIER OUTSIDE CLEAR

720379

ISSUEAPPROVED

AMENDMENT

STANDARD DRAWING

REFERENCES AND NOTES:

ISSUE DATEAPP’D

FAX (03) 9811 8329

PHONE (03) 9811 8355

VICTORIA 3124

CAMBERWELL

3 PROSPECT HILL ROAD

SD NO.

SERVICES

TECHNICAL