standard / double standard magnetic lock · standard installation door door glass frame em lock u...
TRANSCRIPT
INSTALLATION MANUAL
STANDARD / DOUBLE STANDARDMAGNETIC LOCK
Basic Installation Concept & Accessories
EM Lock
Glass
UBK Bracket For
Frame
GlassDoor
Glass Frame & Glass Door
Inswing
Door
Door
Frame
EM Lock
EM Bracket ForInswing Door With Cover
Inswing
LZ Bracket For Inswing Door
Door
Door
Frame
EM Lock
Inswing
Door
Door
EM Lock
Outswing
Frame
Standard Installation
Door
DoorGlass
Frame
EM Lock
U Bracket For Glass Door
Outswing
EM Lock
Door
L Bracket For Outswing Door
FrameDoor
Outswing
Cable Wire
Mounting Plate
Self-tappingScrew x10
Allen Wrench
Electromagnet x2
ArmaturePlate x2
Guide Pin x4
RubberWasher x2
ArmatureScrew x2
Cover PlateCover Screw x2
Anti ResidualMagnetismPart x2
Sexnut Bolt x2
Metal Washer x4
12/24 VDCPower
Anti-tamper Nut x4
Fixing Screw x4
250mA/24VDC500mA/12VDC
Holding Force
Voltage Input
Current Draw
Spec/Model
Cable Wire
Mounting Plate
Self-tappingScrew x5
12/24 VDCPower
Fixing Screw x2
Allen Wrench
Electromagnet
Armature Plate
Guide Pin x2
RubberWasher
ArmatureScrew
Cover Plate
CoverScrew
Anti ResidualMagnetismPart
Sexnut Bolt
Metal Washer x2
300lbs (136kg)
12/24VDC
GEM-300
250mA/24VDC500mA/12VDC
600lbs (272kg)
12/24VDC
GEM-600
250mA/24VDC500mA/12VDC
800lbs (363kg)
12/24VDC
GEM-800
250mA/24VDC500mA/12VDC
1200lbs (545kg)
12/24VDC
GEM-1200
250mA/24VDC x2500mA/12VDC x2
600lbs (272kg)x2
12/24VDC
GEM-D600 GEM-D800 GEM-D1200
250mA/24VDC x2500mA/12VDC x2
800lbs (363kg)x2
12/24VDC
250mA/24VDC x2
500mA/12VDC x2
1200lbs (545kg)x2
12/24VDC
Single Door Double Door
For Outswing Door
INDOOR ELECTROMAGNETIC LOCK SERIES
Standard Installation
1
2
3
4
Template
Armature Plate
Allen wrench
9
Outswing
Power
12.7mm 8mm
Hollow Metal Door
6.8mm for M8-1.25 thread
Reinforced Door
12.7mm 8mm
Solid Door
36mm
5
Rubber Washer
6
77
8
OutdoorOutdoorOutdoor
Recommendation:
For Micro EM-locks (300 LBS), maximum thickness of door is 44 mm.
For Mini EM-locks (600 LBS), maximum thickness of door is 50 mm.
For Midi EM-locks (800 LBS), maximum thickness of door is 48 mm.
For Maxi EM-locks (1200 LBS), maximum thickness of door is 46 mm.
Fold the mounting template 90°
Place the template to the properposition of the door and frame. Mark the hole positions of the template on the door and frame.
Drill the holes according to themarks.
Fix the mounting plate on the door with mounting screws
Use the Allen wrench and fixingbolts to tighten the electromagneticlock to mounting plate
Connect the power and test theunit.
Fasten the mounting plate withthe mounting screws. The positionof the mounting plate should beadjustable.
The rubber washer makes thesurface of the armature plateadjustable in order to completelyfit the surface of magnetic lock.
Please install the armature plateas illustrated here. (Dimensions of the holes depend on the doortypes illustrated below.)
Drill a Ø8mm hole throughdoor on closing side.Enlargeto Ø12.7mm by a sexnutblot on the opening side. The depth is 36mm.
Drill a Ø6.8mm holeand tap on closing sidea M8x12.5 thread.
Drill a Ø8mm hole throughdoor, on closing side.Enlargeto Ø12.7mm by a sexnut bloton the opening side.
LZ bracket for Inswing doors
2
Use the fixing bolt to tighten theelectromagnetic lock on L bracket
1
Find a mounting location on thedoor frame for the L bracket. Makesure that the door is still closeable.
Close the door and connect thepower.
4
Insert the guide pins into thearmature plate.
3
5 6 7 Power
Outdoor
Finish
Outdoor
Power
Assemble the Z bracket, and makesure that the position of the Z bracketis adjustable.
Fasten the armature plate to the Zbracket (Must add rubber washer)
After the maglock attracts thearmature plate, adjust the Z bracket to fit the door.
Fasten the Z bracket to the door
H
Connecting Diagram
Models:
N.O.COM.N.C.
Mag Power Input
Sensor Input
Model:GEM-300M
Control Device N.C. contact or
LED indicatorGREEN: OpenRED : LockedNO LED: No power
Pow reI tupn
SPDT relay0.5A/125VAC
1A/24VDC
Sensor Input
Power Input
N.O.COM.N.C.
Access Relay
Bond sensor outputN.C. contact output: open statusN.O. contact output: locked status
Bond sensor output
N.C. contact output: open statusN.O. contact output: locked status
12 or 24VAutoswitchable
12 or 24VAutoswitchable
Control Device N.C. contact orAccess Relay
12 or 24VAutoswitchable
Bond sensor output
N.C. contact output: open statusN.O. contact output: locked status
LED indicatorGREEN: OpenRED: LockedNO LED: No power
Timer Adjustment
DEL neerG
DEL deR
SP
DT
rel
ay
Sensor in
sdnoces 08~10.5A
/125
VA
C1A
/24V
DC
tupnI rewoP
tupnI rosneS kcoL
.C.N MOC .O.N TSR TSR
JP Setting
(PCB back)
Models:GEM-800MDS-TD-LD, GEM-800MTD-LDGEM-1200MDS-TD-LD, GEM-1200MTD-LD
Relock time delay (Optional)Ensures the automatic lock modeworks after the door is closed properlyand it can be adjusted from 1 to 80
Models: TD series
Orange: N.O.White: ComBrown: N.C.
Door Status Sensor (optional)Door Status Sensor indicates thedoor is in an open or closed status.Models: DS seriesGreen LED (Default)
Red LED
seconds.
Control Device N.C. contact orAccess Relay
Control Device N.C. contact orAccess Relay
GEM-300, GEM-600, GEM-800, GEM-1200GEM-D600, GEM-D800, GEM-D1200
Problem Possible Cause Solution
Door does not lock No power
Poor contact between electromagnet and armature plate
Low voltage or incorrect voltage setting
A secondary diode was installed across the electromagnetic lock
Misalignment between the armature plateand electromagnetic lock
Make sure the wires are connected properly
Check that the power supply is connected and works properlyMake sure the lock switch is wired correctly (N.C.)
Make sure if the armature plate is deformed
Make sure the contact surfaces of the electromagnet and armature plate are clean and free from dust
Make sure the armature plate and electromagnetic lock are aligned correctly
Make sure if the rubber washer was used between magnet lock and armature plate
Ensure the electromagnet lock is set for the correct voltage.
Check for proper voltage at the electromagnetic locks input. If low, determine if the correct wire gauge is being used to prevent excessive voltage drop.
Remove any diode installed across the magnet for "spike" suppression. (The magnet is fitted with a metal oxide varistor to prevent back EMF)
Low holding force
Sensor output is not functioning
Trouble Shooting
N.O.COM.N.C. Mag Power Input
Sensor Input
Orange: N.O.White: ComBrown: N.C.
Timer Adjustment
1~80 seconds
LED indicatorGREEN: OpenRED : LockedNO LED: No power
Control Device N.C. contact orAccess Relay
Bond sensor outputN.C. contact output: open statusN.O. contact output: locked statusModels:
Door Status Sensor (optional)Door Status Sensor indicates the door is in an open or closed status.Models:
Buzzer Alarm (on the reverse)Door Held Open Alarm is an auditory feedback for users.Alarm sounds when the door is not closed for over a specifiedtime limit. VR timer (Timer Adjustment) is adjustable from1 to 80 seconds.
12 or 24VAutoswitchable
(Available for GEM-800MBZ & GEM-1200MBZ)
Relock time delay (Optional)Ensures the automatic lock mode works after the door isclosed properly and it can be adjusted from 1 to 80 seconds.
Connecting Diagram
GEM-600MDS, GEM-800MDS, GEM-1200MDSGEM-D600MDS, GEM-D800MDS, GEM-D1200MDS
GEM-600M, GEM-800M, GEM-1200MGEM-D600M, GEM-D800M, GEM-D1200M
GEM-600M, GEM-800M, GEM-1200MGEM-D600M, GEM-D800M, GEM-D1200M
GEM-D800MBZ & GEM-D1200MBZ)
The warranty period of Transmitter Solutions magnetic locks is twenty-four (24) months. This warranty shall begin on the date the keypad is manufactured. During the warranty period, the product will be repaired or replaced (at the sole discretion of Transmitter Solutions) if the product does not operate correctly due to a defective component. This warranty does not extend to (a) the case, which can be damaged by conditions outside the control of Transmitter Solutions, or (b) battery life. This warranty is further limited by the following disclaimer of warranty and liability:
EXCEPT AS SET FORTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARDING THE GOODS, EXPRESS OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS, EXPRESS OR IMPLIED, WITH REGARD TO THE GOODS AND ACCEPTS THEM “AS-IS/WHERE-IS”. TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE. BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING INJURIES TO PERSONS OR PROPERTY, TO BUYER, ITS EMPLOYEES OR AGENTS, AS A RESULT OF THE SALE. BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS HARMLESS FROM ANY CLAIMS BUYER, OR ANY THIRD PARTY, MAY HAVE AS A RESULT OF BUYER’S USE OR DISPOSAL OF THE GOODS. BUYER HAS READ THIS DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.
WARRANTY:
H