DETAIL LIST
00 / 17 COVER SHEET01 / 17 RIDGE DETAIL02 / 17 HEAD FLASHING DETAIL03 / 17 EAVES GUTTER DETAIL04 / 17 INSULATED GUTTER05 / 17 INSULATED VALLEY BOX GUTTER06 / 17 BARGE CAPPING DETAIL07 / 17 BARGE/PARAPET DETAIL08 / 17 END LAP DETAIL09 / 17 STEP DETAIL10 / 17 SKYLIGHT PANEL DETAIL (OPTIONAL)11 / 17 INSULATED PENETRATION DETAIL12 / 17 STANDARD SIDE LAP DETAIL13 / 17 SIDE LAP DETAIL (ALTERNATIVE 1)14 / 17 SIDE LAP DETAIL (ALTERNATIVE)15 / 17 FASCIA AND HEAD BARGE FLASHING DIMENSIONS16 / 17 SIDE BARGE FLASHING DIMENSIONS17 / 17 PANEL PROFILES AND SIZES
0.55mm RIDGE FLASHINGFLASHING
METALCRAFT MSS PURLINBY ENGINEER
STRUCTURAL STEELFRAMING BY ENGINEER
FOAM INFILL
0.55mm COLORSTEELFLASHING
PROFILLED FILLER SEALEDTOP & BOTTOM
6x4mm BUTYL TAPE
FIXINGMETALCRAFTMETECNOSPANINSULATED PANEL
PRE-FINISHED SELF-TAPPING TEK SCREW WITHNEOPRENE WASHER
5mm
GAP
XX
STOP ENDS TO ROOFCLADDING
300mm MAX
PROFILED EDGE
3° min.
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
SITUATION 2
1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°
MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
X
SITUATION 3
1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mmX
ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE
ACCEPTABLE SOLUTION AS PER E2/ASI
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
RIDGE DETAIL
01 / 1730.08.2016
0.55 COLORSTEEL FLASHING
TURN UP ROOF PANSTO FULL RIB HEIGHT
METALCRAFTMETECNOSPAN CLADDING
METALCRAFT METECNOSPANROOFING
FOAM SEAL
STRUCTURAL STEELFRAMING BY ENGINEER
6x4mm BUTYL TAPE
PRE-FINISHED SELF-TAPPING TEKSCREW
PROFILED FILLER SEALED TOPAND BOTTOM
Z
X
5mm
GAP
PROFILED EDGE
3° m
in.
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. LOW, MEDIUM AND HIGH WINDZONES WHERE ROOF PITCH ≤ 10°MIN. 200mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 70mm
X
Z
SITUATION 3
1. ALL ROOF PITCHES IN EXTRAHIGH WIND ZONE
MIN. 200mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 90mm
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mm
MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)
X
Z
ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE
ACCEPTABLE SOLUTION AS PER E2/ASI
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
HEAD FLASHING DETAIL
02 / 1730.08.2016
PRE-FINISHED 0.55 GUTTERFLASHING
PRE-FINISHED SELF-TAPPING TEK SCREW
METALCRAFTMETECNOSPANROOFING
INSULATED PANELSTRUCTURAL STEELFRAMING BY ENGINEER
FASTEN GUTTER BRACKETWITH SUITABLE LENGTH TEKSCREWS INTO FASCIAPURLIN (BY OTHERS)
METALCRAFT BOXGUTTER 175 WITHEXTERNAL BRACKET
FR FOAM SEAL
75 MIN
3° min.
6x4mm BUTYL TAPE
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
EAVES GUTTER DETAIL
03 / 1730.08.2016
75
0.55mm COLORSTEEL FLASHING
METALCRAFT METECNOSPANROOFING
ROOF SUPPORT STRUCTURE(BY OTHERS)
METALCRAFT MSS PURLINBY ENGINEER
PRE-FINISHED SELF-TAPPING TEKSCREW TO EVERY RIB WITHSEALED WASHERPARAPET AND COVER
FLASHINGS (BYOTHERS)
CONCRETE PARAPET (BYOTHERS)
75m
m M
IN
150m
m M
IN
0.55mm COLORSTEEL FLASHING
1.5mm STEEL BRACKET(BY OTHERS)
INSULATED PANEL GUTTER(SUPPORTED BY OTHERS)
INSULATED PANEL
0.55mm COLORSTEEL FLASHING
BUTYNOL (BY OTHERS)
0.55mm COLORSTEELFLASHING
BUTYL TAPE (OPTIONAL)
CONTINUED
100mm BUTYNOL
75m
m M
IN 3° min.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
INSULATED GUTTER
04 / 1730.08.2016
80 80
0.55mm COLORSTEEL FLASHING
METALCRAFT METECNOSPANROOFING
METALCRAFT METECNOSPANROOFING
ROOF SUPPORT STRUCTURE(BY OTHERS)
METALCRAFT MSS PURLINBY ENGINEER
SELF-TAPPING TEK SCREW WITHNEOPRENE WASHER IN EVERY RIB
INSULATED PANEL
INSULATED PANEL
0.55mm COLORSTEEL FLASHING
1.5mm STEEL BRACKET (BYOTHERS)
BUTYNOL (BY OTHERS)
INSULATED PANELS (BY OTHERS)
250mm MIN
BUTYL TAPE (OPTIONAL)
0.55 FILLET BRACKET
75m
m M
IN
75m
m M
IN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
INSULATED VALLEY BOX GUTTER
05 / 1730.08.2016
0.55 Z PROFILE FLASHING (NOTNEEDED WHEN OVER 2 RIBS)
FOAM FILL
ROOF SUPPORTSTRUCTURE (BY OTHERS)
0.55mm COLORSTEEL FLASHING
METALCRAFT INSULATED PANEL
Z
PRE-FINISHED SELF-TAPINGTEK SCREW
Y
5mm
GAP
METALCRAFTMETECNOSPAN ROOFING
0.55 Z PROFILE FLASHING (NOTNEEDED WHEN OVER 2 RIBS)
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°
AT LEAST TWO CRESTS
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. LOW, MEDIUM & HIGH WINDZONES WHERE ROOF PITCH ≤ 10°AT LEAST TWO CRESTS
MIN. 70mm
Y
Z
SITUATION 3
1.ALL ROOF PITCHES IN EXTRAHIGH WIND ZONE
AT LEAST TWO CRESTS
MIN. 90mm
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Y
Z
ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE
ACCEPTABLE SOLUTION AS PER E2/ASI
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
BARGE CAPPING DETAIL
06 / 1730.08.2016
0.55mm COLORSTEEL FLASHING
METALCRAFTMETECNOSPAN PANEL
FLASHING TO SECOND CROWNOR USE 'Z' FLASHING
ROOF SUPPORT STRUCTURE(BY OTHERS)
PRE-FINISHED SELF-TAPPINGTEK SCREW TO EVERY RIBWITH SEALED WASHER
6X4 BUTYL TAPE
0.55mm APRON FLASHING
PARAPET AND COVERFLASHINGS (BY OTHERS)
CONCRETE PARAPET (BYOTHERS)
5mm
GAP
Z
GN
L
L BRACKET (BY OTHERS)
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES,WHERE ROOF PITCH ≥ 10°
MIN. 35mm
MIN. 75mm
MIN. 130mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, & HIGH WINDZONES WHERE ROOF PITCH ≤ 10°
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 70mm
G
N
L
Z
SITUATION 3
1. ALL ROOF PITCHES IN EXTRAHIGH WIND ZONE
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)
MIN. 90mm
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
MIN. 150mm
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
25mm
MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)
MIN. 200mm
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)
G
N
L
Z
ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE
ACCEPTABLE SOLUTION AS PER E2/ASI
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
BARGE/PARAPET DETAIL
07 / 1730.08.2016
PRE-FINISHED SELF-TAPPINGTEK SCREW TO EVERY RIB
METALCRAFTMETECNOSPANROOFING
6x4mm BUTYL SEALANT
STITCHING SCREWS WITHNEO WASHER TWO PERPAN
OVERLAP
225
ROOF SUPPORT STRUCTURE(BY OTHERS)
METALCRAFT METECNOSPANROOFING
3° min.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
END LAP DETAIL
08 / 1730.08.2016
FOAM INFILL
TURN DOWN PAN APRROX20° (SPECIAL TOOLAVAILABLE)
4mm Ø STEEL RIVET
0.55mm COLORSTEELFLASHING
PRE-FINISHED SELF-TAPPING TEK SCREWS TOEVERY RIB (TYPICAL)
PROFILED FILLER SEALEDTOP AND BOTTOM
6x4mm BUTYL TAPE SEALANT
TURN UP PAN TO FULL RIBHEIGHT(SPECIAL TOOL AVAILABLE)
0.55mm COLORSTEEL FLASHING
ROOF SUPPORT STRUCTURE(BY OTHERS)
250
DETAIL RECOMMENDEDWHERE ROOF RUNSEXCEED 16m
5mm
GAP
3° min.
RO
OF STEP
50mm
METALCRAFT METECNOSPANROOFING
METALCRAFTMETECNOSPAN ROOFING
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
STEP DETAIL
09 / 1730.08.2016
TOPGLASS GC ULTRASAFE 1.8mm3660GSM TOP SKIN
• ALSYNITE RECOMMEND CONTINUOUSRUN FROM RIDGE TO GUTTER
• R-VALUE OF ROOFLIGHT =0.57• NO SAFETY MESH REQUIRED• FOR MORE INFORMATION REFER
www.alsynite.co.nz
TEK SCREW TO EVERY RIB WITHSEALED WASHER
12mmØ EPDM SEAL
ROOF SUPPORTSTRUCTURE (BY OTHERS)
METALCRAFTMETECNOSPAN ROOFING
LASERLITE MAKROLON TWO LAYERS,6mm LAMINATED TOGETHER
STITCHING SCREWS @ 300CRS
TEK SCREW TO EVERY RIBWITH SEALED WASHER
12mmØ EPDM SEAL
METALCRAFTMETECNOSPAN ROOFING
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
SKYLIGHT PANEL DETAIL (OPTIONAL)
10 / 1730.08.2016
1.6mm SOAKER TRAY
PENETRATION PROVIDED &WEATHER SEALED BY OTHERS
250mm MINIMUM
700mm MAXIMUM
50
INSULATED PANEL UPSTANDSAME R-VALUE(min) AS ROOF
TURN UP PANS TO FULL RIBHEIGHT
0.55mm COLORSTEEL FLASHING
PRE-FINISHED SELF-TAPPINGTEK SCREW WITH NEOPRENEWASHER
PROFILED FILLER SEALEDTOP AND BOTTOM
METALCRAFTMETECNOSPAN INSULATEDPANEL
6x4mm BUTYL TAPE
1.6mm ALUMINIUMDIVERTER WELDED TOSOAKER TRAY
1.6mm SOAKER TRAY
CUT BACK CROWNOF ROOF PROFILE
6x4mm BUTYL TAPE
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 5
INSULATED PENETRATION DETAIL
11 / 1730.08.2016
ROOF SUPPORT STRUCTURE(BY OTHERS)
METALCRAFTMETECNOSPANROOFING
TEK SCREW
ROOF WASHER
12mmØ EPDM SEAL
BUTYL TAPE SEALANT
6x4mm BUTYL TAPESEALANT (WHERE OPTIMUMSEALING IS REQUIRED)
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems As indicated
STANDARD SIDE LAP DETAIL
12 / 1730.08.2016
ROOF SUPPORT STRUCTURE(BY OTHERS)
METALCRAFTMETECNOSPANROOFING
TEK SCREWROOF WASHER
12mmØ EPDM SEAL
6x4mm BUTYL TAPESEALANT (WHERE OPTIMUMSEALING IS REQUIRED)
EPDM SEAL
SIPHON GROOVE
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFING
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet
Rev: R0CRMS
MetecnoSpan (PIR)
1 : 2
SIDE LAP DETAIL (ALTERNATIVE 1)
13 / 1730.08.2016
ROOF SUPPORT STRUCTURE(BY OTHERS)
METALCRAFTMETECNOSPANROOFING
STORM TIGHTFASTENER
ROOF WASHER
EPDM DOMED SEALINGWASHER
6x4mm BUTYL TAPESEALANT (WHERE OPTIMUMSEALING IS REQUIRED)
SIPHON GROOVE
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFING
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet
Rev: R0CRMS
MetecnoSpan (PIR)
1 : 2
SIDE LAP DETAIL (ALTERNATIVE)
14 / 1730.08.2016
METALCRAFTMETECNOSPANROOFING
GUTTER
FASCIA FLASHINGØ5mm STEEL RIVETS @300mm CRS
HEAD BARGE FLASHING
TURN UP WEATHERPROOF
150
40
50 10
TO SUIT ROOF PITCH (90° - ROOF PITCH)
TO SUIT ROOF PITCH (90° + ROOF PITCH)
20
20
TO SUIT ROOF PITCH(90° - ROOF PITCH)
TO SUIT ROOF PITCH(90° + ROOF PITCH)
METECNOSPAN HEAD BARGE FLASHING METECNOSPAN FASCIA FLASHINGVA
RIE
S D
EPEN
DEN
T O
N P
ITC
H
VAR
IES
DEP
END
ENT
ON
PIT
CH
30
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 2
FASCIA AND HEAD BARGE FLASHING DIMENSIONS
15 / 1730.08.2016
METALCRAFT METECNOSPANROOFING
METECNOSPAN BARGE FLASHING METECNOSPAN BARGE FLASHING
Ø5mm RIVETS @ 300 CRS
x = 2RIBS
110
10
38
METECNOSPAN SIDE BARGE
Metecnospanthickness
FlashingHeight (a)
40mm 111mm
60mm 131mm
80mm 151mm
100mm 171mm
SIDE BARGEa
30
38
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems 1 : 2
SIDE BARGE FLASHING DIMENSIONS
16 / 1730.08.2016
Metecnospan PIR
A38
1000
FINELINE FINISH
SCALE @ 1:5
SCALE @ 1:2
A = 40, 60, 80 & 100mm
20
3
34 34
2
2
INTERNAL LINER FINISHES
SATINLINE FINISH
MICRO V RIB FINISH
1
15 30
4 59
3
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer.
COMMERCIAL ROOFING
ScaleDate Sheet
MetecnoSpan CommercialMetalcraftInsulated Panel Systems As indicated
PANEL PROFILES AND SIZES
17 / 1730.08.2016