Stairwell Fixture Solutions NEW! Stairwell LED fixture Radio Powr SavrTM wireless corner-mount occupancy/vacancy sensor

Upload: others

Post on 15-May-2020

21 views

Category:

Documents


6 download

TRANSCRIPT

Stairwell Fixture Solutions

NEW! Stairwell LED fixture

Radio Powr SavrTM wireless corner-mount occupancy/vacancy sensor

Stairwell Fixture Solutions

What are stairwell fixture solutions? Stairwell fixtures are a retrofit solution that automatically adjust light output based on stairwell occupancy.

• Utilizes an integral Lutron wireless lighting control device, programmed to occupied and unoccupied light levels that are field-adjustable and specific to a project’s code requirements

• Receives signal from Radio Powr SavrTM occupancy/vacancy sensors (sold separately) via Lutron reliable Clear Connect® RF technology

• Provides the flexibility to determine occupancy/vacancy sensor quantities, mounting configuration, and placement requirements per the stairwell design

How does it work?Occupied: 50% light levelUnoccupied: 10% light level

2

3

1

Stairwell fixture

Radio Powr Savr occupancy/vacancy sensor (wall mount)

Wireless Signal ReceivedLutron ® Clear Connect ®

Wireless Signal SentLutron ® Clear Connect ®

Wireless Signal Two-wayLutron ® Clear Connect ®

Wireless Signal ReceivedLutron ® Clear Connect ®

Wireless Signal SentLutron ® Clear Connect ®

Wireless Signal Two-wayLutron ® Clear Connect ®

2

3

1

Benefits Energy savings – ability to save over 80% of lighting energy usage1

– high-end trim reduces light levels when occupied

– occupancy sensing lowers light levels when unoccupied

Simple installation – wireless communication between devices allows the occupancy/vacancy sensor(s) to be mounted in the location that provides the maximum area of coverage with no need for additional wiring

High ROI – payback as low as 3-years; utility rebates available in most locations2

Flexible – assign multiple fixtures to a single occupancy/vacancy sensor, allowing multiple fixtures to adjust to the occupied light level

Meets codes and standards (see back cover for details)

1 Rebates and savings assumes the replacement of a 2 lamp 40W T12 stairwell fixture at full output for 8760 hours with a 2 lamp 32W T8 fixture at 50% output for 2190 hours and 10% output for 6570 hours. LEDs may see greater savings due to reduced wattage.

2 Payback varies depending upon lamp wattage, usage, electricity rates, and available rebates. For more information on utility rebates, visit www.lutron.com/incentives.

3 Reduced wattage T8 lamps only available in 4 ft fixture with the lowest end dimming of 10%.

Features Stairwell fixtures

• PowPak® fixture: 2, 3, 4, or 8 ft; 1, 2, or 4 lamps; lamp options: T8, reduced wattage T83, T5HE, or T5HO• Vandal-resistant fixture: 2 or 4 ft; 2 lamps; lamp options: T8, T5HE, or T5HO• LED fixture: 2 ft; 4000 K color temperature LED module; module options: 17 W, 1500 Lumens or 30 W, 2400 Lumens• 120-277 V~ universal input voltage• Ceiling or wall surface mount• Optional emergency ballast battery backup available for Stairwell PowPak fixtures• ADA compliant

Radio Powr SavrTM occupancy/vacancy sensors• Ceiling-, wall-, hall-, and corner-mount configurations available • Customize timeout to 1, 5, 15 or 30 minutes• Exclusive Lutron XCTTM technology – enhanced passive infrared (PIR) sensing• Control up to 9 fixtures with one sensor• 10-year battery life

Stairwell PowPak® fixture

NEW Stairwell LED fixture

Stairwell vandal-resistant

fixture

Radio Powr Savr

occupancy/vacancy sensors

www.lutron.com

World Headquarters 1.610.282.3800Technical Support 1.800.523.9466 (Available 24/7)Customer Service 1.888.LUTRON1 (1.888.588.7661)

© 09/2012 Lutron Electronics Co., Inc. I P/N 367-2034 REV E

How to build a model number

Codes and standards• ASHRAE 90.1 2010 Additional Control (9.4.1.6) Lighting in stairwells shall have one or more control devices to automatically reduce lighting power in

any one controlled zone by at least 50% within 30 minutes of all occupants leaving that controlled zone.

• IgCC (International Green Construction Code) Interior Light Reduction Controls (609.3) Occupant sensor controls shall be provided to automatically reduce connected lighting power by not

less than 45% during periods when occupants are not present in all of the following locations: 1. Corridors and enclosed stairwells. 2. Storage and stack areas not open to the public. 3. Parking garages.

FXSW ____ ____ ____ ____ ____ U ____ _____ _____ WH

Size:121,2 = 1’ x 2’

13 = 1’ x 3’

142 = 1’ x 4’

18 = 1’ x 8’

Lens options:SL1 = Standard

CP = Clear Prismatic Acrylic

OA = Opal Acrylic

PO2 = PolyCarbonate

Lamp type:142 = 14 W, T5HE, 2 ft172 = 17 W, T8, 2 ft21 = 21 W, T5HE, 3 ft242 = 24 W, T5HO, 2 ft25 = 25 W, T8, 3 ft282 = 28 W, T5HE, 4 ft322 = 32 W, T8, 4 ft39 = 39 W, T5HO, 3 ft542 = 54 W, T5HO, 4 ftRW = 25, 28, 30 W T8 reduced wattage, 4 ftC11 = 17 W, 4000 K, 1500 LumensC31 = 30 W, 4000 K, 2400 Lumens

Controls:51 = 50% High, 10% Low

82 = 80% High, 20% Low

Mounting:SM = Surface-mount

M4 = 4 ft Mounting Plate

(available for 2 ft LED stairwell only)

Options:XX = None

E1 = T8 Emergency Ballast

E33,4 = T5HE Emergency Ballast

E53,4 = T5HO Emergency Ballast

Lamps:1 = 1 Lamp

22 = 2 Lamps

4 = 4 Lamps (8 ft fixture only)

L1 = LED module

Type:XX1 = Standard

VR = Vandal-resistant

Example:FXSWXX12CP114U51SMXXWHStandard, 1-lamp with clear prismatic acrylic lens, 14 W, 2 ft fixture, preset high (occupied) and low end (unoccupied) levels are 50% and 10%, no emergency ballast

For pricing and availability, please contact your local Lutron representative or [email protected].

1 Stairwell LED fixture is only available in these select options2 Stairwell vandal-resistant fixture is only available in these

select options3 Emergency ballast “option” not available

if 2’ “lamp type” is chosen 4 Emergency ballast “option” is determined by “lamp type”

MarkWinters
Typewritten Text
E7 = LED Emergency Driver