st9120u1003 universal electronic fan timer training module

20
ST9120U1003 Universal Electronic Fan Timer Training Module

Upload: brenna-gilbert

Post on 30-Dec-2015

48 views

Category:

Documents


5 download

DESCRIPTION

ST9120U1003 Universal Electronic Fan Timer Training Module. ST9120U - What You Will Learn:. Product Overview Set Up Installation Troubleshooting Product Cross Reference ST9120 Advantage. What is the ST9120U Electronic Fan Timer?. - PowerPoint PPT Presentation

TRANSCRIPT

ST9120U1003Universal Electronic

Fan TimerTraining Module

2

• Product Overview• Set Up• Installation• Troubleshooting• Product Cross Reference• ST9120 Advantage

ST9120U - What You Will Learn:

3

What is the ST9120U Electronic Fan Timer?

• A universal electronic fan timer that integrates control of all combustion blower and circulating fan operations in a gas warm air appliance

- Monitors the thermostat for heat, cool and fan demands.

- Runs the induced draft blower motor and runs the circulating fan (up to two speeds) as needed.

- Monitors limit switch strings and energizes ignition control.

- Central wiring point for the electrical components of the furnace. Saves time! One part number:

ST9120U1003

4

ST9120U Electronic Fan Timer Features

• Why choose the Honeywell ST9120U?

• Universal application• Replaces over 25 existing Honeywell controls

• Easy installation• DIP switch selectable circulating fan delays

• Heat on/off delay• Cool on/off delay (cool off fixed at 30 seconds)

Single model services multiple furnace applications Included with the ST9120U:

• Wiring information and adapter for the ST9101• Original appliance application• Delay timing recommendation

• Quality construction for a long service life

Installation

6

Installation of the ST9120U

• Location and Mounting- Mount the ST9120U Electronic Fan Timer in the appliance wiring

compartment or furnace vestibule

- Mounting screws provided

• Wiring- Make sure that all wiring complies with local codes and

ordinances.

- Disconnect power before making wiring connections.

Set-Up

8

Set up of the ST9120U

• Setting DIP switches- Heat fan-on delay

On: 30/60 Seconds Starts timing when main valve energized

- Heat fan-off delay Off: 60/100/140/180 Seconds Starts timing when main valve is de-energized

- Cool fan-on delay On: 4/30 Seconds Starts with call for cooling

- Cool fan-off delay fixed at 30 seconds

- Post Purge: 5 seconds

9

Set up of the ST9120U

Recommended dip switch settings are included in the installation instructions as well as the Honeywell Residential Combustion Application and Selection Guide.

Troubleshooting

11

Troubleshooting of the ST9120U

• Look for appropriate voltages at the ST9120U terminals

• Check operation and timing of:- Combustion blower

- Fan at heating speed

- Fan at cooling speed

• Check limit operation and system response

Note: The ST9120U schematics show internal switching to clarify operation and assist in troubleshooting.

Product Cross Reference

13

Product Cross Reference

The ST9120U replaces over 25 existing Honeywell controls:

ST9101A1006 ST9120C1020 ST9120C4016 ST9120G2016

ST9101A1014 ST9120C2002 ST9120C4040 ST9120G2024

ST9101A1022 ST9120C2010 ST9120C4057 ST9120G2032

ST9120A1006 ST9120C2028 ST9120C5005 ST9120G4004

ST9120A2004 ST9120C3000 ST9120C5013 ST9120G4012

ST9120B1005 ST9120C3018 ST9120D3009 ST9120G4038

ST9120C1012 ST9120C4008 ST9120G2008  

14

Product Cross Reference

• Where do I find Honeywell universal fan timer cross reference information?

- www.customer.honeywell.com

- Honeywell Application Selection and Cross

Reference Guide – Form 63-9575

- Honeywell Laminated Truck Visor – Form 63-9581

- Honeywell Residential Technical Support: 1-800-468-1502

15

www.customer.honeywell.com

• See Cross Reference Search box in right column.

16

ST9120U Advantage

• When promoting the ST9120U keep these advantages in mind:

- The ST9120U universal control replaces over 25 existing Honeywell controls. This in turn, reduces inventory and saves time looking for the right part.

- A central wiring point for most of the electrical components of the furnace makes installation easy and gets the installer on to the next job faster.

- Easy to set selectable heat and cool on/off settings adapt to the application.

- The ST9120U makes the choice simple; one control saves time and money, improving your bottom line.

ST9120U1003Universal Electronic Fan Timer

Knowledge Test

18

• Now that you completed this training module, take the short quiz to test your knowledge.

ST9120U Knowledge Test

19

Test

1. The ST9120U Universal Electronic Fan Timer controls the blower and circulating fan in gas warm air appliances? T or F

2. The ST9120U is a central wiring point for most of the electrical components in the furnace? T or F

3. The ST9120U replaces over 25 Honeywell and competitor controls? T or F

4. The universal electronic fan timer monitors the thermostat for heat, cool and fan demands? T or F

5. The heat and cool on/off delays are set through dip switches? T or F

6. Honeywell only has one resource for cross reference information? T or F

20

Answer Key

1. T2. T3. F4. T5. T6. F