1. Features Introductions
2. Reader Front panel & types of proximity card
3. Operation instructions
Start reader
Mode inquiry
Antiduress
Setup mode
4. Quick setting
5. Setup mode function selection instructions (00~28)
3
4
5
5
5
5
5
6
6
6. Installation instructions
7. Hardware specifications
8. Attentions
9. TROUBLESHOOTING
(01) Add new card
(02) Delete card
(04) Shunt time
(05) Open door mode
(07) Reset to release alarm
(08) Change system password
(09) Reset to release antiduress alarm
(10) Reader ID number
(11) Password error times
(12) Antiduress code
(13) Total cards
(14) Program version
(15) Set time
(16) Set date
(17) Auto record range
(18) Main reader location
(19) Door shutting time
(20) Alarm mode
(21) Antiduress alarm mode
(22) Door sensing mode
(23) Antitheft sensing mode
(24) Push button door open sensing mode
(25) BEEP sound mode
(26) Print mode
(27) Antipass mode
(28)Display card number mode
(00) Instand door open
(90) Historical Data Inquiry
Reader connector
Wiring connection for additional electric lock and push button door open switch
Wiring connection for additional magnetic door sensing
Wiring connection for antitheft sensing (NO Type)
Wiring connection for additional alarm
Wiring connection for linking with computer
20
20
20
21
21
22
23
24
24
24
-
ST680 OPERATION INSTRUCTIONS
1. Features introductions
When connecting with computer, it can be used for data inquiry and function setting
simutaneously.(Door open/close,start a larm system,etc).I t can also operate solely to
manage access control.
Function setting can be done by computer or reader itself.(Single registration or
deletion,door open time,etc).
The capacity data input/output can reach up to 6,000 by single reader operation.When
linking with computer,its data input/output capacity can be unlimited.
Main reader has 9,000 card regis trations capability.Each card can be selfsetting for
personal password and effective in/out time.
Main reader has 48 units of time zone.Each time zone unit also has 5 time ranges for
selfsett ing by user.
Example:It can be set from"G" hour "H" minute to "I" hour "J" minute on every
Mondays,Wednesdays,Saturdays in periodic of "A" year "B" month "C"
day to"D" year "E" month "F" day as effective in/out time range.
Directly link to series type printer for direct data printing.
Additional subreader for in/out control .
Equipped with hardware selftesting function.
Internal batteries wil l provide power supply when power cut occurred to prevent any
data from being erased and system time can operate as normal.
Main reader access control's range:
Main reader's sensing range:
Card number
Password
Time zone
Special holidays
Error control
Antipass
Antitamper
Antitheft
Illegal door open
It must be registered before use.
Personal password has to key in to open the door.
Setting the effective of year,month,day,time range,Monday~Sunday.
User could set any holidays as to prevent any unauthorized access.
A larm will actvate when"N" times of consecutive error password
entering occurred.
The card could only be used for matching single entry and exit.
(Otherwise,it will be considered the card has been duplicated
causing access denial.)
When the reader is tampered,alarm will be activated.
Alarm will be activated when sensing any abnormal operations.
Alarm will be activated when door is destroyed and opened by force.
3
-
Antiduress
Exceed door shut time Alarm will be activated,when door is not closed exceeding intial
time sett ing control.
Door open button sensing Door will open immediately when the button is pushed.
It will operate when password and duress code are keyes in to send help
signal to the nearest police station.It must be done manually to disable
antiduress function.
2. Reader Front Panel & Types of Proximity Card
(a) Front Panel Indicator Lights
(b) 10 entry (button),two function keys : "#"&" ".
(c) Types of prox imity card
(1). POWER (red)
(2). OK (green)
(3). DENY (yellow)
(4). STATUS (yellow)
# key : input data confirm key (Enter)
key : clear or escape key (CLR/ESC)
: power indicator.
: door open indicator.
: operation error or unregis tered card indicator.
: system starts and setup mode indicator.
12345678
4
SC10 : Thin card , thickness 0.8 mm, ISO standardcard dimensions. It can be printed directlyfrom card printer. Read rangeEM 125KHz 10 15cm, Mifare 13.56MHz 3 7cm.
SC20 : Thick card , thickness 1.8 mm, ISO standardcard dimensions. Read rangeEM 125KHz 10 20cm
SC30 : Key tag, dimensions: 5.5L X 7.5H X 3.2W (mm).Ultrasonic connection, waterproof,shock proof. Read rangeEM 125KHz 6 10cm,Mifare 13.56MHz 1.5 4cm
-
3. Operation instructions
Start reader:It will begin selftesting function when power is switched on.Its operation
procedures are as follow:
LCD DISPLAY
SRAM TESTING
RTC TESTING
INITIAL FUNCTION
08:05
0010
INSTRUCTIONS
Memory tesying
Real time clock teseing
Init ial system setting
Model (ST680),present time (08:05),10 registrations.
Note:Card must not exceed the read range (refer to different models) to
gain induction.
a).OK (green) light is on to indicate registered card to gain access.
b).DENY (yellow) light is on and consecutive beeping sound is on to
indicate unregistered card or used under unauthorized time zone.
(Please refer to troubleshooting if neither of above statuses occurred)
Mode inquiry:Press , LCD will display: MD ADR YYYY/MM/DD2 001 1999 / 01 / 01
MD
ADR YYYY/MM/DD
: open door mode (2 shows door open by proximity card
sensing, 3 shows door open by proximity card sensing with
password.)
: main reader number. : current date.
Repress to escape.
Antiduress:When under duress, usermay press button before keyingin password to activate alarm.(Duress code presetting is, it can be changed by user)
Example : antiduress code is , password is ,then to activate antiduress alarm, the user should key in
.
Setup Mode:
SYSTEM FUNCTIONS SELECTION : _ _
User must get into setting mode first beforechanging any system functions. User mustkey in for systemfunction selection. is beingset initially by manufacturer.(Example: User can get into the set up modeby keying ).
system passwordSystem password
5
-
4. Quick setup:
5. SETTING MODES & FUNCTIONS
User will get into the setup mode as the right diagram shown for any setting
to be made.
(A) Add new card , key in then key in .
(B) Delete card, key in then key in .
(C) Door open time, key in then key in the seconds .
(D) Change reader number, key in then key in the reader number .
(E) Door open mode, key in then key in the mode code .
(F) Time setting, key in then key in the time .
(G) Date setting, key in then key in .
Note: (1)Sunday (2)Monday (3)Tuesday (4)Wednesday (5)Thursday (6)Friday
(7)Saturday
(H) Release alarm, key in , confirmed then press .
( I ) Release antiduress alarm, key in , confirmed then press .
8dig it card number
8digit card number
13:00:15
2000/01/01 (6)
FUNCTION (01) Add new card:
Either key in 8digit card number or use proximity card to register, both can beaccepted but should be registered prior using.
key in#system password# Key in 01
Key in # or
Key in the # or
Go into function 01.
Queuing 8dig it card number inputkey in manual ly or by proximity.
Registra tion successfulbeep sound occurred .
Registration repeated,beepsound on continuously.
back to system function selection.
Esc system function select ion.
SYSTEM FUNCTIONSELECTION : _ _
ADD ONE CARD_ _ _ _ _ _ _ _
ADD ONE CARD00000001
ADD ONE CARDACCESS DENIAL
Go into system function setup.sta tus loght on,displayfunction selection.
6
-
Function (02) Delete card:
Deletion of user's card (such as loss of card or to prevent specific user to gain
access) can be achieved by keying 8digit card number indicated on the
proximity card.
key in#system password#
key in#system password#
Key in 02
Key in 04
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into function 02.
Go into function 04.
Queuing 8dig it card number inputkey in manual ly or by proximity.
Queuing 8dig it card number inputkey in manual ly or by proximity.
Deletion successful,abeep sound occurred .
Deletion successful,abeep sound occurred .
NO such card,beepsound on continuously.
NO such card,beepsound on continuously.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
DELETE ONE CARD_ _ _ _ _ _ _ _
SET SHUNT TIME(1255):003_ _ _
SET SHUNT TIME(1255):003 000
SET SHUNT TIME(1255):003 005
DELETE ONE CARD00000001
DELETE ONE CARDACCESS DENIAL
Go into system function setup.
Go into system function setup.
sta tus light on,displayfunction selection.
sta tus light on,displayfunction selection.
Function (04) Shunt time:
Setting of relay's ON/OFF time in the proximity reader can be set from 01255
seconds. (presetting time is 003 )
7
-
Function (05) Door open mode:
Reader has 2 types of identification modes. (presetting figure is 002)
Card proximity door opening: The door will be opened, when the card
is sensed.
Door open by proximity card and password: The door will be opened
by keying additional 4digit password after sensing the registered
card.
Mode (2).
Mode (3).
key in#system password#
key in#system password#
Key in 05
Key in 07
Key in # or
Key in # or
Key in the # or
Press other keys
Go into function 05.
Go into function 07.
Queuing the identificationmode input.
Queuing the alarm inputis reset or not.
Wrong input beepsound on continuously.
Setting successfully,ala rm is released.
Setting successful ly,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
ALARM RELEASEDYES => "#"
Key in the #
Go into system function setup.
Go into system function setup.
sta tus light on,displayfunction selection.
sta tus light on,displayfunction selection.
Function (07) Reset to release alarm:
User sets to release the alarm.
IDENTIFICATIONMODE (23) :2
IDENTIFICATIONMODE (23) :1
IDENTIFICATIONMODE (23) :3
8
-
Function (08) Change system password:
The reader's password is being set at initially by manufacturer.In order to enter into system setting mode for the first time, user mustkey in the initial system password . User may change the systempassword after entering into system setting mode.
key in#system password# Key in 08
Key in # or
Key in the # or
Go into func tion 08.Queuing new systempassword input.
Input successfully (4 digits).
Error input.
Esc system function selection.
Esc system function selecti on.
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.sta tus light on,d isplayfunction selection.
INPUT NEW SYSTEMPASSWORD : _ _ _ _
CONFIRM SYSTEMPASSWORD : _ _ _ _
CONFIRM SYSTEMPASSWORD : 0000
CONFIRM SYSTEMPASSWORD : 1234
INPUT NEW SYSTEMPASSWORD : 1234
INPUT NEW SYSTEMPASSWORD : _12#
Beep sound on consecutively,error input.(first last 4digit password different) Reenter new system
password for confirmation.
Input successfully,(same password)
Function (09) Reset to release antiduress alarm:
User sets to release the antiduress alarm.
key in#system password# Key in 09
Key in # or
Press other keys
Go into function 09.Queuing for anti duressalarm released or not.
Setting successfully,antiduress a larm is released.
back to system function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
ALARM RELEASEDYES => "#"
Key in the #
Go into system function setup.sta tus light on,displayfunction selection.
9
-
Function (10) Reader ID number:
Each reader has a reader ID number for computer identification and the number
should not be repeated. (presetting figure is 001)
key in#system password#
key in#system password#
Key in 10
Key in 11
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 10.
Go into func tion 11 .
Queuing the identificationmode input.
Queuing the identificationmode input.
Wrong input beepsound on continuously.
Wrong input beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selec tion.
back to system function selec tion.
Esc system function selecti on.
Esc system function selecti on.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
READER ID NUMBER(1255) : 001 _ _ _
ERROR TIMES(1255) : 003 _ _ _
ERROR TIMES(1255) : 003 256
ERROR TIMES(1255) : 003 002
READER ID NUMBER(1255) : 001 256
READER ID NUMBER(1255) : 001 002
Function (11) Password error times:
Alarm will be activated when "N" times of consecutive error password entering
occurred. (presetting figure is 003)
10
-
Function (12) Antiduress code :
Set up of antiduress code ( , ). (presetting code is )
key in#system password#
key in#system password#
key in#system password#
Key in 12
Key in 13
Key in 14
Key in # or
Key in # or
Key in # or
Go into function 12.
Go into function 13.
Go into function 14.
Queuing for antiduresscode input.
Display total number ofcurrent registered cards.
Display program version.
Setting successfully,beep sound occurred .
back to system function selection.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
SET DURESS CODE09, : _
USER CARD COUNT0200
VERSION : V1.08
SET DURESS CODE09, : 9
Key in the # or
Press any key
Press any key
Go into system function setup.
Go into system function setup.
Go into system function setup.
sta tus light on,displayfunction selection.
sta tus light on,displayfunction selection.
sta tus light on,displayfunction selection.
Function (13) Total cards:
Display total number of current registered cards.
Function (14) Program version:
Display program version.
11
-
Function (15) Set time:
Example: 18 hour 00 minute 00 second => 18:00:00 (presetting figure is
00:00:00)
key in#system password#
key in#system password#
Key in 10
Key in 16
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 10.
Go into func tion 16.
Queuing for systemtime input.
Queuing for systemdate input.
Wrong input, beepsound on continuously.
Wrong input, beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
SET TIME17 : 50 : 50
SET DATA1999/01/01(5)
SET TIME17 : 50 : 99
SET DATA1999/03/29(0)
SET TIME18 : 00 : 00
SET DATA1999/03/29(1)
Function (16) Set date:
Example 2000/04/30 Sunday => 2000/04/30 (1) (presetting is 2000/01/01 (5))
12
-
Function (17) Auto Record range:
This is to set under what kind of status to save by stand alone operation.
(presetting figure is 003). There are 4 kinds of status to choose:
A. Detect point / output action. (+1) B. Computer special command. (+2)
C. Single reader operation status. (+4) D. User error status. (+8)
Example:
If A and B statuses are chosen, the setting figure for auto record range is 3 (1+2)
If A, B, and D statuses are chosen, the setting figure for auto record range
is 11 (1+2+8)
key in#system password#
key in#system password#
Key in 17
Key in 18
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 17.
Go into func tion 18.
Queuing for autorecord range input.
Queuing for main readerlocation input.
Wrong input, beepsound on continuously.
Wrong input, beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
AUTO REC RANGE(1255) : 012 _ _ _
READER=>0/INDOOR1/OUTDOOR :1
READER=>0/INDOOR1/OUTDOOR :2
READER=>0/INDOOR1/OUTDOOR :0
AUTO REC RANGE(1255) : 012 256
AUTO REC RANGE(1255) : 012 011
Function (18) Main reader location:
To show the location of the reader: (0) Indoor, (1) outdoor. (presetting location
is 001)
13
-
Function (19) Door shutting time:
Time setting for sensing doorshutting time as to activate the alarm when
exceeding the set value. (presetting value is 030)
key in#system password#
key in#system password#
Key in 19
Key in 20
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 19.
Go into func tion 20.
Queuing for doorshuntting time input .
Queuing for alarmmode input.
Wrong input, beepsound on continuously.
Wrong input, beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
DOOR SENSOR SEC(1255) : 030 _ _ _
ALARM MODE(0/ON,1/OFF) :1
ALARM MODE(0/ON,1/OFF) :2
ALARM MODE(0/ON,1/OFF) :0
DOOR SENSOR SEC(1255) : 030 256
DOOR SENSOR SEC(1255) : 030 015
Function (20) Alarm mode:
(0)shows "ON",(1) shows "OFF ". (presetting figure is 000)
Once set at "OFF" , alarm will not function.
14
-
Function (21) Antiduress alarm mode:
(0) shows "ON" ,(1) shows "OFF", (presetting figure is 000). Once set at
"OFF", antiduress alarm will not funct ion.
key in#system password#
key in#system password#
Key in 21
Key in 22
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 21.
Go into func tion 22.
Queuing for antiduress mode input.
Queuing for doorsensing mode input.
Wrong input, beepsound on continuously.
Wrong input, beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
ANTIDURESS MODE(0/ON,1/OFF) :1
DOOR SENSOR MODE(0/ON,1/OFF) :0
DOOR SENSOR MODE(0/ON,1/OFF) :2
DOOR SENSOR MODE(0/ON,1/OFF) :1
ANTIDURESS MODE(0/ON,1/OFF) :2
ANTIDURESS MODE(0/ON,1/OFF) :0
Function (22): Door sensing mode:
(0) shows "ON", (1) shows "OFF". (presetting figure is 000). Once set at "OFF",
the sensing mode will not function at any abnormal door opening.
15
-
Function (23) Antitheft sensing mode:
(0) shows "ON", (1) shows "OFF". (presetting figure is 000). Once set at
"OFF", the sensing mode will not funct ion at any cases of broken in.
key in#system password#
key in#system password#
Key in 23
Key in 24
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 23.
Go into func tion 24.
Queuing for antitheft mode input.
Queuing for push buttonswitch mode input.
Wrong input, beepsound on continuously.
Wrong input, beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
ANTITHEFT MODE(0/ON,1/OFF) :0
PUSH BUTTON MODE(0/ON,1/OFF) :0
ANTITHEFT MODE(0/ON,1/OFF) :2
PUSH BUTTONMODE(0/ON,1/OFF) :2
ANTITHEFT MODE(0/ON,1/OFF) :1
PUSH BUTTONMODE(0/ON,1/OFF) :1
Function (24) Push button door opening sensing mode:
(0) shows "ON", (1) shows "OFF". (presetting figure is 000). Once set at
"OFF', the sensing mode will not function if the push button is pressed.
16
-
Function (25) BEEP sound mode:
(0) shows "ON", (1) shows "OFF". (presetting figure is 000). Once set at "OFF"
, the BEEP sound will not function.
key in#system password#
key in#system password#
Key in 25
Key in 26
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 25.
Go into func tion 26.
Queuing for BEEPsound mode input.
Queuing for BEEPsound mode input.
Wrong input, beepsound on continuously.
Wrong input, beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
BEEP MODE(0/ON,1/OFF) :0
BEEP MODE(0/ON,1/OFF) :1
BEEP MODE(0/ON,1/OFF) :2
BEEP MODE(0/ON,1/OFF) :2
BEEP MODE(0/ON,1/OFF) :1
BEEP MODE(0/ON,1/OFF) :0
Function (26) Print mode:
(0) shows "ON", (1) shows "OFF". (presetting figure is 001) Once set at "ON",
stored data can be printed out immediately.
17
-
Function (27) Antipass mode:
(0) shows "ON", (1) shows "OFF". (presetting figure is 001) Once set at "ON"
, the card could only be used for matching single entry and exit. This is to
prevent double entry by using the same card if card has been duplicated.
key in#system password#
key in#system password#
Key in 27
Key in 28
Key in # or
Key in # or
Key in the # or
Key in the # or
Go into func tion 27.
Go into func tion 28.
Queuing for antipass mode input.
Queuing for d isplay cardunmber mode input.
Wrong input, beepsound on continuously.
Wrong input, beepsound on continuously.
Setting successfully,beep sound occurred.
Setting successfully,beep sound occurred.
back to system function selection.
back to system function selection.
Esc sys tem function selection.
Esc sys tem function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Go into system function setup.
Go into system function setup.
sta tus light on,d isplayfunction selection.
sta tus light on,d isplayfunction selection.
ANTIPASS MODE(0/ON,1/OFF) :1
D ISPLAY USER ID(0/ON,1/OFF) :0
D ISPLAY USER ID(0/ON,1/OFF) :2
D ISPLAY USER ID(0/ON,1/OFF) :1
ANTIPASS MODE(0/ON,1/OFF) :2
ANTIPASS MODE(0/ON,1/OFF) :0
Function (28) Display card number mode:
(0) shows "ON", (1) shows "OFF". (presetting figure is 000). Once set at "OFF",
LCD will not display the card number.
18
-
Function (00) Instant door open:
Authorized personnel could get into the setup mode to open the door when any
emergency cases happened.
key in#system password#
key in#system password#
Key in 00
Key in 90
Key in
Date Time
0001 12345678 17
04/01/01 16:30
OPEN DOORYES = > " # "
Key in # or
Key in # or
Go into function 00.
Go into function 00.
Queuing for dooropen input.
Setting successfully,beep sound occurred.
back to system function selection.
Esc system function selection.
Esc system function selection.
SYSTEM FUNCTIONSELECTION : _ _
SYSTEM FUNCTIONSELECTION : _ _
Key in the #
Press other key
Go into system function setup.
Go into system function setup.
status light on,displayfunction selection.
status light on,displayfunct ion selection.
Function (90) Historical Data Inquiry:
Inquiring historical data from standalone unit.
Press 1: Minus one 2: Add one 3: Minus 10 4: Add 10 5: MiddleState:01 Enter 06 Push Button Door Open02 Exit 17 Invalid Card No.03 Reader has already been taken apart 24 System Door Open
19
-
6. Reader instal lation instructions
(1)Reader connector
YellowPurpleBlueGreenBrownRed
PurpleBlueGreenBrownRed
PWMSub Reader connector 1.Sub Reader connector 2.Output power,positive 5VOutput power,negative GND
GNDAntiduress output terminal (low active)Door sensing terminal 2Door sensing terminal 1Antitheft sensing termina l (low active)Push button door open point terminal
PurpleBlueGreenYellowOrangeBrownBlackRed
Alarm Relay terminal N.O or N.CAlarm Relay terminal COMDoor open relay (N .O or N.C) terminalDoor open relay (Common) terminalSigna l (data) receiverSigna l (data+) transmitterInput power,negative GNDInput power,posit ive 12V
ST680 Wiring diagram
6 PINCONNECTOR
5 PIN CONNECTOR
8 PIN CONNECTOR 6 PIN CONNECTOR
Push butt on switch
Diode s white color termina l
Nude typeelectrica l lock
RS232/RS485 Swi tch
RS232 RS485
8 PINCONNECTOR
Note: (1) Door open relay electrical rating is 2A/24 VDC.
(2) Push button door open / door sensing / antitheft sensing all are
connection terminal. Any other power supplying is not al lowed.
(3) In order to avoid any disturbance of read range, user is advised to
use two separate adaptors.
(4) Related position of reader connector: Please refer to Appendix A.
(2) Wiring connection for additional electric lock and push button door open
switch.
As of different types of electric lock, the wiring methods are also different .
Overall, there are two types of wiring instructions as below:
(a) Fail secure :
Jump Adjustment(JP10)
R BK BR O Y G BL P R BR G BL P Y
AP10DC 12V
AP10DC 12V
A EL
- -N.O Output
20
-
8 PIN CONNECTOR 6 PIN CONNECTOR
6 PIN CONNECTOR
6 PIN CONNECTOR
6 PIN CONNECTOR
Push butt on switch
Diode s white color termina l
Electro Magnetic lock
(b) Fail safe :
Jump Adjustment(JP10)
R BK BR O Y G BL P R BR G BL P Y
AP10DC 12V
AP10DC 12V
- -N.C Output
Note:User must ensure the polarity (Diode) of the wiring connection for
additional electric lock is arranged correctly so that it is functional.
(3)Wiring connection for additional magnetic door sensing.
(a) N.O. type magnetic spring : (b) N.C. type magnetic spring :
R BR G BL P Y
R BR G BL P Y
R BR G BL P YN.O. type
magnet ic spring
N.O. type magnetic spring
N.C. type magnet ic spring
(4) Wiring connection for antitheft sensing. ( N.O. type )
21
-
(5) Wiring connection for additional alarm.
(a) Alarm :
(b) Antiduress alarm :
8 PIN CONNECTOR
Diode s whitecolor terminal
Diode s whitecolor te rminal Eternal Relay
Connection DC12V
Alarm powersupply DC12V
Alarm powersupply DC12V
Jump Adjustment(JP10) R BK BR O Y G BL P
N.C OutputN.O Output
+
-
Note User must ensure the polarity (Diode) of the wiring connection for
additional alarm is arranged correctly so that it is functional. User
must also ensure that Setting Mode (20) Alarm Mode is set ON.
:
8 PIN CONNECTOR 6 PIN CONNECTOR
R BK BR O Y G BL P R BR G BL P Y
K
ANO
NCCOM
Note User must ensure the polarity (Diode) of the wiring connection for
additional antiduress alarm is arranged correctly so that it is
functional. User must also ensure that Setting Mode (21) Anti
Duress Alarm Mode is set ON.
:
22
-
(6) Wiring connection for linking with computer
8 PIN CONNECTOR 8 PIN CONNECTOR 8 PIN CONNECTOR
R BK BR O Y G BL P R BK BR O Y G BL P R BK BR O Y G BL P
POWERTXDRXD
AP30 CONVERTERRS232 to RS485
RS232
RS485
RS232
+-
RS485 interface transit connector
PC
PC
RS232communication line
RS232commun ication line
8 PIN
RedBlackBrownOrangeYellowGreenBluePurple
1
2
3
4
5 9
8
7
6
23
-
7. HARDWARE SPECIFICATIONS
8. ATTENTIONS
9. TROUBLESHOOTING
Power supplyWorking enviromentLCDButtonsReal time clockRAMPower backup systemCommunication system
Output control system
Input sensinsystem
(A) Alarm output terminal can be connected with additional external alarm unit forsounding.
(B) Open door output terminal can be matching used with electric lock for accesscontrol.
(C) Antiduress output terminal can be connected with hidden alarm to send helpsignal to the nearest police station.
(A) Push button door open sensing point.Door wil l open instantly when button ispressed.
(B) Door status terminal can be connected with external magnetic spring for sensingif the door is closed or not.
(C) Antitheft sensing terminal can be connected with external magnetic spring forsensing if any appliances are closed or not.
(D) Antitamper sensing terminal used to sense if the reader is being tampered byforce.
DC 12V/1A,Adapter.Temperature 0 C6
0 C,Humidity 15%85%.16*2 STN LCD display with 4 LED's indicators.12 stainless steel buttons.Internal equipped with a Real Time Clock(RTC)IC.128 KB memory.Equipped with standby battery for saving if power is cut.Equipped intermally with RS485 interface.It can beexpanded to 255 terminals linking with computer operationsimultaneously.
1. Confirm the power supply voltage and polarly before installation to prevent anywrong connection that causedamage to the reader.
2. Use separate power supply to the electric lock and the proximity reader.3. Do not install the reader nearly any metal equiments or detector area to prevent
interference of read distance.4. Do not try to fix or modify the reader without authorized electrician.The reader is
guaranteed for one year.
1. Reader has no reaction or door does not open with proximity card.Solution: (1) Please check if the POWER light(red)is on.If not,p lease check the power
supply to run the reader on.(2) Please check if the proximity card is defected.User may use another proximity
card to test.(3) Please check if personal password is entered incorrectly or the user is still in
the setup mode.(4) Continuous proximity.Please remove the card from the reader and try again.(5) Check if the DENY light(yellow) is on and continuous beep sound occur. This
indicates the user's proximity card is not registered yet.(6) Please check if OK Light(green) is on and dooropening sound can be heard
at the same time.If door is still not opened,please ensure that if the wiring or
24
-
power supply of electric lock is instal led properly or broken.
2. System password is entered but user cannot enter into various function selection ofthe setting mode.
3. How to use antiduress setting?
Solution: (1) System password is entered incorrectly.Please check if the fol lwing step hasbeen entered correctly. # XXXX # .(XXXX represent system password),orpress button first and then enter the correct system password # 5678 # .
(2) Bad wiring arrangement may affect key enter data.Please confirm that thepower supply wire and the control wire have been arranged to the space at theback of the LCD (this is the wiring arrangement area of this unit).This is toprevent the wires pressing on the wiring on the PC board causing bad contact,short circuit and interference.
Solution: (1) Please change the door open mode to mode 3.Therefore,door will be openedonly by keying additional 4digi t password after sensing the registeredproximity card.
(2) When the door open mode is set,press antiduress code (user can preset theantiduress code)before entering 4digit password,thus the antiduress alarmwill be activated.
25
-
APPENDIX A
Installat ion Steps :Step 1,2Secure power supply wire and control wire through the base panel.Step 3 Fit the reader on the base panel (power supply wire and control wire
must first be inserted and the wires must be arranged correctly)Step 4 Use enclosed key wrench and screws to mount the reader up.
JP8
JP10 JP11
5 PIN
6 PIN 8 PIN
RS232/RS485 SWITCH
Related posit ion of reader connector :
26
-
Wiring diagram of ST680 and ST110ERB/ST120ERB
AP10DC 12V
R BK BR O Y GR BL P
8Pin
ST680
R BR GR BL P
GND
SP0
DATA0
SP1
DATA1
Wiegand input
ST680 5Pin
AP10DC 12V
ReaderST110ERB/ST120ERB
27
-
AP10DC 12V
1
2
3
4
5 9
8
7
6