Prerequisites: IMPORTANT: Before deploying software updates on a target system, be sure that a recent backup of the target system is available in the event the deployment procedure fails. Supplement installation for Linux servers has the following minimum requirements: glibc 2.2.4-26 or later gawk 3.1.0-3 or later sed 3.02-10 or later pciutils-2.1.8-25.i386.rpm or later The following RPMs are also required: rpm 4.0.4 or later rpm-build 4.0.4 or later rpm-devel 4.0.4 or later To successfully deploy HP SUM on remote target systems based on a Linux operating system, the following must be available: tcl-8.x package expect-5.x package The command interpreter (shell) /bin/bash must be installed. For autorun capabilties, the system must be running X with a window manager and an installed browser. For some distributions, the CD must be mounted and the ./autorun command executed for autorun to function. Note: Please ensure the following RPMs are also installed. For Red Hat Enterprise Linux 5 AMD64/EM64T servers: compat-libstdc++-296-2.96-132.7.2.i386 or later lm_sensors-2.8.7-2.x86_64 or later net-snmp-5.3.1-14.el5.x86_64 or later perl (needed to provide the libperl.so) libnl (needed for QLogic and Emulex drivers) To ensure the integrity of your download, HP recommends verifying your results with the following MD5 Checksum values: 40a04656174146939ad32cc988b8e16b temp/bp002012.xml cd986ac5f370de2f010a80787528f295 supspp_rhel5.10.en.tar.gz

Upload: jjagdishh

Post on 23-Nov-2015

8 views

Category:

Documents


0 download

DESCRIPTION

SPP Installation Doc

TRANSCRIPT

Prerequisites:IMPORTANT:Before deploying software updates on a target system, be sure that a recent backup of the target system is available in the event the deployment procedure fails.Supplement installation for Linux servers has the following minimum requirements: glibc 2.2.4-26 or later gawk 3.1.0-3 or later sed 3.02-10 or later pciutils-2.1.8-25.i386.rpm or laterThe following RPMs are also required: rpm 4.0.4 or later rpm-build 4.0.4 or later rpm-devel 4.0.4 or laterTo successfully deploy HP SUM on remote target systems based on a Linux operating system, the following must be available: tcl-8.x package expect-5.x packageThe command interpreter (shell) /bin/bash must be installed.For autorun capabilties, the system must be running X with a window manager and an installed browser. For some distributions, the CD must be mounted and the ./autorun command executed for autorun to function.Note:Please ensure the following RPMs are also installed.For Red Hat Enterprise Linux 5 AMD64/EM64T servers: compat-libstdc++-296-2.96-132.7.2.i386 or later lm_sensors-2.8.7-2.x86_64 or later net-snmp-5.3.1-14.el5.x86_64 or later perl (needed to provide the libperl.so) libnl (needed for QLogic and Emulex drivers)

To ensure the integrity of your download, HP recommends verifying your results with the following MD5 Checksum values:40a04656174146939ad32cc988b8e16btemp/bp002012.xml

cd986ac5f370de2f010a80787528f295supspp_rhel5.10.en.tar.gz

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:Installation of the Supplement for HP Service Pack for ProLiant Using Autorun:supplements may be installed via autorun if autorun is configured on the target Linux server.Red Hat distributions include autorun. If autorun is not installed, it must be installed and properly configured before beginning.

Note:Red Hat Enterprise Linux automount the CD with the noexec property set. In order to run Autorun, the CD must be first be unmounted and then manually remounted.For other distributions, several autorun utilities are available for download from various Internet sites. These distributions will typically mount the CD-ROM on /media/cdrom.For the purposes of these instructions, the CD-ROM is assumed to have been mounted on /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions.Manual Installation of theSupplement for HP Service Pack: For the remainder of this discussion, the CD mount directory will be considered to be /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions. If the CD-ROM mount point is not defined in /etc/fstab, a complete mount command will be required. Download the latest Supplemental SPP as applicable. It will be in zipped format. Login on the console as root Copy the Supplement SPP on your local server. The Supplement will be in zipped format. Unzip/ Untar the supplement SPP. Go to the supplement SPP folder either through GUI and run hpsum file or in command prompt give ./hpsum. Make sure to give read write permission to this file. Or

If the Operating is of x64bit architecture, go to x64bit folder in supplement SPP, and run ./hpsum_bin_x64. This will launch HPSUM in the browser automatically. If the Operating system is of x86bit architecture, go to x86 folder in supplement SPP, and run ./hpsum_bin_x86. This will launch HPSUM in the browser automatically. Note: Make sure to have the supported browser installed on your system.The installer will open an interactive session which will allow you to install the Linux ProLiant Support Pack OR Linux Supplemental Service pack for proliant.

NOTE:Be sure to include the version of the compatibility libraries that is appropriate for your architecture. In some cases, there are separate 32-bit and 64-bit compatibility libraries for a given distribution.For a current list of supported Linux distributions and versions (and their associated errata kernels), see theoperating system support matrixes. The supplments are designed for use after you install the operating system so that you can update drivers, install HP utilities (such as Health and iLO drivers), and install agents (Server, NIC, and Storage).