spectrum techniques ucs-20spectrumtechniques.com/manuals/ucs20manual.pdf · the ucs-20 requires...

129
S S p p e e c c t t r r u u m m T T e e c c h h n n i i q q u u e e s s U U C C S S - - 2 2 0 0 U U n n i i v v e e r r s s a a l l C C o o m m p p u u t t e e r r S S p p e e c c t t r r o o m m e e t t e e r r SPECTRUM TECHNIQUES, INC. 106 Union Valley Road Oak Ridge, TN 37830 USA Tel. (865) 482-9937 Fax. (865) 483-0473 e-mail: [email protected] Web Site: http://www.spectrumtechniques.com

Upload: others

Post on 24-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

SSSpppeeeccctttrrruuummm TTTeeeccchhhnnniiiqqquuueeesss UUUCCCSSS---222000

UUUnnniiivvveeerrrsssaaalll CCCooommmpppuuuttteeerrr SSSpppeeeccctttrrrooommmeeettteeerrr

SPECTRUM TECHNIQUES, INC. 106 Union Valley Road Oak Ridge, TN 37830

USA Tel. (865) 482-9937 Fax. (865) 483-0473 e-mail: [email protected]

Web Site: http://www.spectrumtechniques.com

Page 2: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

Table of Contents Introduction ......................................................................................................................... 5

Screen View .................................................................................................................... 7 Installation........................................................................................................................... 8

Connections On Rear Panel............................................................................................. 9 Installing Software ........................................................................................................ 11 Uninstalling Software.................................................................................................... 12

Analysis Modes ................................................................................................................. 13 Pulse Height Analysis ................................................................................................... 14 Multi Channel Scaling................................................................................................... 15 External Multi Channel Scaling .................................................................................... 17

Operation........................................................................................................................... 18 Live Mode ..................................................................................................................... 19 File Mode ...................................................................................................................... 20 Amp/HV/ADC .............................................................................................................. 21

High Voltage ............................................................................................................. 23 Amplifier Coarse Gain .............................................................................................. 24 Amplifier Fine Gain .................................................................................................. 25 ADC Conversion Gain .............................................................................................. 26 Lower and Upper Level Discriminators.................................................................... 27

Presets............................................................................................................................ 28 Preset Time................................................................................................................ 29 Preset Integral............................................................................................................ 30

Go, Stop and Erase ........................................................................................................ 31 Region of Interest (ROI) ............................................................................................... 32

Functions ........................................................................................................................... 34 Energy Calibration ........................................................................................................ 35 Isotope Matching........................................................................................................... 36 Strip Background........................................................................................................... 39

Load Spectrum .......................................................................................................... 40 Load Background ...................................................................................................... 41 Show Spectrum ......................................................................................................... 42 Show Background ..................................................................................................... 43 Overlay Spectra ......................................................................................................... 44 Strip Background from Spectrum ............................................................................. 45

Data Smoothing............................................................................................................. 46 Menu Bar........................................................................................................................... 47

File................................................................................................................................. 48 File Open ................................................................................................................... 49 File Save.................................................................................................................... 50 File Load Setup ......................................................................................................... 51 File Save Setup.......................................................................................................... 52 File Load Library ...................................................................................................... 53 File Save Library....................................................................................................... 54

Page 3: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

File Print.................................................................................................................... 55 File Print Preview...................................................................................................... 56 File Print Setup.......................................................................................................... 57 File Exit ..................................................................................................................... 58

Edit ................................................................................................................................ 59 Edit Experiment......................................................................................................... 60 Edit Iso Match ........................................................................................................... 61 Edit Smooth Data ...................................................................................................... 62

Mode.............................................................................................................................. 63 Mode Pulse Height .................................................................................................... 64 Mode Multi Channel Scaling .................................................................................... 65 Mode External Multi Channel Scaling...................................................................... 66

Display .......................................................................................................................... 67 Display Peak Report.................................................................................................. 68 Display Data Report .................................................................................................. 69 Display Calibration ................................................................................................... 70 Display ROIs ............................................................................................................. 71 Display Iso Match ..................................................................................................... 72 Display Pixel Sizes.................................................................................................... 73

Settings .......................................................................................................................... 74 Settings ROIs............................................................................................................. 75 Settings Energy Calibrate.......................................................................................... 78 Settings Preset ........................................................................................................... 82 Settings Amp/HV/ADC............................................................................................. 83 Settings MCS ............................................................................................................ 84 Settings Color............................................................................................................ 85

Strip Background........................................................................................................... 87 Strip Background - Load Spectrum........................................................................... 88 Strip Background - Load Background ...................................................................... 89 Strip Background - Show Spectrum.......................................................................... 90 Strip Background - Show Background...................................................................... 91 Strip Background – Overlay Spectra......................................................................... 92 Strip Background – Strip Background from Spectrum ............................................. 93

View .............................................................................................................................. 94 Tool Bar..................................................................................................................... 95 Status Bar .................................................................................................................. 96

Help ............................................................................................................................... 97 Contents..................................................................................................................... 98 Using Help................................................................................................................. 99 About....................................................................................................................... 100

Tool Bar........................................................................................................................... 101 Go................................................................................................................................ 102 Stop.............................................................................................................................. 103 Erase ............................................................................................................................ 104 Show Peak Report ....................................................................................................... 105 Show Data Report ....................................................................................................... 106

Page 4: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

Amp/HV/ADC ............................................................................................................ 107 Presets.......................................................................................................................... 108 ROI.............................................................................................................................. 109 Spectrum Window Sizing............................................................................................ 110

Y axis Increase ........................................................................................................ 111 Y axis Decrease....................................................................................................... 112 Y axis Log ............................................................................................................... 113 X axis expand.......................................................................................................... 114 X axis contract......................................................................................................... 115 X axis right 256 channels ........................................................................................ 116 X axis right 16 channels .......................................................................................... 117 X axis left 16 channels ............................................................................................ 118 X axis left 256 channels .......................................................................................... 119

Status Bar ........................................................................................................................ 120 Specifications .................................................................................................................. 121

Hardware ..................................................................................................................... 122 Software ...................................................................................................................... 123

Spectrum Techniques Contact......................................................................................... 124

Page 5: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KIntroduction

Hardware

The Universal Computer Spectrometer offers a unique solution for nuclear spectrometry using the PC platform. A 2K ADC combined with 8K of data memory and multi-channel scaling is ideally suited to scintillation spectroscopy and time related studies such as half-life decay.

Constructed in a sturdy, fully-shielded bench top enclosure with Universal Serial Bus (USB) computer interface, the multi channel analyzer contains many advanced features including computer controlled amplifier and high voltage for PM tubes, upper and lower level discriminators, on instrument data memory, and a comprehensive software package for use under Windows 98 or higher. (Windows 95 may be used if you have installed the USB patch.)

The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs. For stability and low noise operation, the unit is AC-line powered with an auto-sensing power supply for 100-250 VAC operation. An on-board microprocessor acts as the master controller and data storage device, as well as the communication link directly to the USB interface.

The integrated amplifier and high voltage are fully compatible with most standard scintillation detectors, eliminating the need for special tube bases and external modules. For ease of setup and calibration, coarse gain, fine gain, high voltage, and lower and upper level discriminator settings are controlled directly from the desktop computer. For operation with other types of detector systems such as alpha spectrometers or single photon counting, a DIRECT input is provided to bypass the scintillation amplifier and allow direct access to the ADC.

A 2048 channel ADC with de-randomizing buffer offers excellent data throughput at high counting rates with minimal dead-time losses. Conversion gain may be changed from 2048 to 1024 to 512 or 256 channels via the software. Data from the ADC is stored directly in on-board memory for autonomy and high-speed operation, freeing the host computer for other tasks.

Software

The UCS-20 produces a high-resolution, real-time live color display of spectral data with standard PC graphics running under Windows (95 and above). Operation is intuitive

#IDH_INTRODUCTION $Introduction KIntroduction

Page 6: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

using pull-down menus and function buttons for the most commonly used commands and display options. The software offers full control of all features including preset live/real time, and regions-of-interest together with centroid, gross and net area calculations.

Control of the hardware amplifier, high voltage, ADC and input discriminators is also through function buttons for straightforward calibration and operation. To simplify identification of peaks, the cursor may be calibrated to read directly in energy units, using either a 2-point linear, or 3-point quadratic relationship to allow for detector non-linearity.

Spectral files may be transferred to disk for long-term storage as binary files or transferred through the clipboard in ASCII format for exporting to other programs. Stored files may be used to collect background data over a long counting period that can be subtracted on a time proportional basis from the spectral data.

To aid in the identification of nuclides, the UCS-20 contains a unique peak-labeling feature named ISOMATCH. Providing the unit is accurately energy calibrated, the user may select a nuclide from the library and the corresponding characteristic emission lines are superimposed on the spectrum along with isotope and energy information. Using this feature, users may quickly check a spectrum and visually identify the emission components for each nuclide present. The ISOMATCH libraries may be created or customized using a text editor.

When operating in multi channel scaling mode, the system may be calibrated in time units for direct readout from the cursor.

Both linear and logarithmic vertical display ranges are included which can be useful when performing decay studies

Spectrum files, can be transferred from the ICS 10 DOS program and the ICSW 16 Windows program to the UCS20 Windows version. Most functions may be accessed by more than one method. All the functions can be accessed from the Pull Down Menu, some from the Tool Bar Buttons, or by the mouse. If the function has a Tool Bar Button, its symbol will be shown on the left hand side of the description.

Page 7: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KScreen View

#IDH_INTROSCREENVIEW $Screen View KScreen View

Page 8: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KInstallation System Requirements The UCS20 instrument uses a Universal Serial Bus (USB) to communicate with a PC. The PC must have USB compatible drivers, which are available standard on Windows 98 and later releases. Windows 95 must have the USB upgrade or patch to work. The performance of the USB on older systems may affect the perceived performance of the software; so we recommend that you use a Pentium 2 or greater class of microprocessor running at 250 mHz or greater to achieve desirable performance. The executable code is less than 600 kb, but the help files are more than 5 mb; so if you have limited disk space, you may wish to leave the help files on the CD.

Installing Software Connections On Rear Panel Uninstalling Software

#IDH_INSTALLATION $Installation KInstallation

Page 9: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KConnections On Rear Panel The UCS-20 is equipped with an internal Amplifier/Preamplifier allowing direct connection of a scintillation detector. If you plan to use this feature, connect the signal (anode) output of the detector tube base to the PREAMP IN connector on the rear of the instrument using a BNC cable and connect the high voltage to HIGH VOLTAGE with the MHV cable These cables appear similar with the MHV being slightly longer than the BNC

Rear Panel HV Output: MHV (or optional SHV) connector supplies positive 0 - 2500 volt @ 1mA maximum current to power scintillation detector. High voltage is fully regulated and computer controlled in 25 volt increments. PREAMP IN: BNC connector for direct connection to PMT anode signal. Uses internal

#IDH_INSTCONNECTIONSONREARPANEL $Connections On Rear Panel KConnections On Rear Panel

Page 10: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

amplifier/preamp. AMP IN: BNC connector for signal connection to external preamplifier. DIRECT IN: BNC connector for connection to external amplifier. Bypasses internal amplifier and connects directly to ADC input. Accepts unipolar or bipolar signals 0-8volt range. EXT MCS: BNC connector to input positive MCS TTL pulses > 150nsec. 5 MHz maximum rate. ROI OUT: BNC connector supplies a pulse out when data is acquired in a channel marked as a ROI. The pulse width is adjustable from 100usec to 25 msec by an internal pot. The pulse amplitude is adjustable from 0volt to 7.5 volts by an internal pot. GATE IN: BNC connector for connection to external coincidence unit. A positive TTL pulse causes the ADC to accept the next pulse. The Gate pulse must be present before the peak of the input Pulse. Gate pulse width = 50nsec to 2usec. MSB OUT: (OPTIONAL) BNC connector to output the most significant MCS bit for Mossbauer Applications. T/COMP: Modular connector for connection to temperature compensated tube base. HIGH VOLTAGE: MHV (OPTIONAL SHV) connector supplies positive 0 to 2500 volts to power scintillation detectors and proportional tubes. 1-Watt maximum Power available. USB: Universal Serial Bus connector for communication with computer. PREAMP POWER: (OPTIONAL) DB-9 connector, supplies + – 12v power for External preamplifier. When using an external amplifier system, connect the amplifier unipolar or bipolar output to the DIRECT IN connector.

Page 11: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KInstalling Software Insert the included CD in your CD-ROM drove. The install program will automatically run. Follow the instructions to select the options you want to install. The application is less than 600 kb, but the help files are greater than 3 mb; if you have limited disk space, you may not want the help file installed. You can access the help file on the CD. The default installation directory is C:\SpecTech\UCS20 Example files Spectrum (*.spu) files: Normal.spu – contains an uncalibrated spectrum of CS-137. Calibrated.spu – contains a calibrated spectrum of CS-137. Setup (*.sup) files: Normal.sup – has settings used in Normal.spu. Calibrated.sup – has settings used in Calibrated.spu. Library (*.itm) files Isotopes.itm – contains a list of common isotope peaks for use with the IsoMatch function.

#IDH_INSTINSTALLINGSOFTWARE $Installing Software KInstalling Software

Page 12: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KUninstalling Software Go to the Windows Start Menu, select Settings, then Control Panel. On the Control Panel, select Add/Remove Software. Find UCS20, double click and follow the instructions.

#IDH_INSTUNINSTALLINGSOFTWARE $Uninstalling Software KUninstalling Software

Page 13: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KAnalysis Modes

See:

Pulse Height Analysis Multi Channel Scaling External Multi Channel Scaling

#IDH_MODES $Analysis Modes KAnalysis Modes

Page 14: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KPulse Height Analysis

This is the normal operating mode for collecting sample gamma emission spectra. The amplitude of each detector pulse is measured by the ADC and stored as an amplitude (energy) spectrum. The X axis is scaled to the selected channels and the Y axis is scaled for the counts for each channel. Y axis counts that exceed the maximum Y axis value are ‘wrapped’, they no longer are scaled to the Y axis, and they appear in a different color.

#IDH_MODESPHA $Pulse Height Analysis KPulse Height Analysis

Page 15: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KMulti Channel Scaling

Multi Channel Scaling mode is used for measuring time related phenomena such as half-life decay or single photon counting. The ADC is bypassed and incoming events are routed directly into memory for specific predetermined times (dwell time) and stored in sequential memory locations. To use this mode, first acquire a spectrum using the Pulse Height Analysis mode. While acquiring the spectrum, adjust the LLD and the ULD to select the energy range of interest (for example, selecting only the 662 keV peak form CS-137 can eliminate unwanted background and produce a superior decay curve when using a Cs-137/Ba-137 mini-generator.)

Click the Mode menu and select MCS #IDH_MODESMCS $Multi Channel Scaling KMulti Channel Scaling

Page 16: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

Click the Settings menu and select MCS

Enter the Dwell Time. This time is for each memory location (channel). Remember the total pass time will be (Conversion Gain x Dwell Time). Erase any current memory data and click start. The UCS20 will proceed to count incoming events for the selected dwell time, store the total in the first channel location, reset the counter and repeat the cycle storing each total in sequential channels.

Page 17: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KExternal Multi Channel Scaling

If you wish to use an external pulse generation system such as a coincidence circuit, it will be necessary to bypass the on-board amplifier and discriminators. Connect the external counts connector to the Ext MCS connector on the back of the instrument and select the menu item MODE then select External MCS. When operating in this mode, the MCS input requires positive TTL signals (>2.5v, >150 ns duration).

#IDH_MODESEXTERNALMCS $External Multi Channel Scaling KExternal Multi Channel Scaling

Page 18: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KOperation

Screen View Live Mode File Mode Amp/HV/ADC Presets Go, Stop and Erase Region of Interest (ROI)

#IDH_OPERATION $Operation KOperation

Page 19: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KLive Mode

The software starts up in the Live Mode. This mode uses the USB to communicate with the instrument. If you access the File Menu and click on Open, a new window appears which looks like the current window, except that the title bar shows ‘File Mode’ instead of ‘Live Mode’. File mode does not communicate with the instrument and is used only to view and manipulate files that have been saved to disk.

#IDH_LIVEMODE $Live Mode KLive Mode

Page 20: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Mode

File Mode is accessible from the live mode by going to the File Menu and clicking on Open. Select the file you want to view. Some functions, which have no use when viewing files, are disabled in the Menus and the Toolbar.

#IDH_FILEMODE $File Mode KFile Mode

Page 21: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KAmp/HV/ADC

Click the Amp/HV/ADC Button on the toolbar:

Or use the settings menu and click on Amp/HV/ADC

The Amp/HV/ADC dialog box will appear. Adjustments may be made to the amplification, high voltage, conversion gain, low level discriminator, and the high level discriminator. #IDH_SETTINGSAMP/HV/ADC $Amp/HV/ADC KAmp/HV/ADC

Page 22: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

Selecting OK will cause these values to be written to the UCS20 instrument. Configuring System Parameters: Once the program is running it will be necessary to configure the system parameters for correct operation and calibration. Place a gamma emitting check source near the detector face. Cesium-137 (Cs-137) is a good choice. It has single peak at 662 keV. Click on Settings, then click on Amp/HV/ADC Set the high voltage to the voltage as listed by the detector manufacturer. As an example, set the high voltage to 600 volts, click ON. DO NOT exceed the maximum high voltage rating of the detector, usually 1200 volts. Set the amplifier COARSE GAIN to 8, and set the FINE GAIN to 1 as a starting position. Click on OK, to set adjustments and exit the menu. Start the data acquisition and adjust the amplifier gain until the 662 keV peak is approximately mid-scale. Once the acquisition is started, you may enter the Amp/HV/ADC menu, make adjustments while viewing the spectrum. This will allow you to position the peak in the desired channels.

High Voltage Amplifier Coarse Gain Amplifier Fine Gain ADC Conversion Gain Lower and Upper Level Discriminators

Page 23: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KHigh Voltage

High Voltage may be entered directly in the text box or may be scrolled to the value desired. A warning will be issued if you attempt to input a value higher than 1200 volts, since this is the highest value that many probes can tolerate without damage. If you know that your probe can accept higher than 1200 volts, you may increase the voltage up to 2500 volts. See also:

Amp/HV/ADC

#IDH_SETTINGSHVA $High Voltage KHigh Voltage

Page 24: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KAmplifier Coarse Gain

Amplifier coarse gain may be set by clicking the radio-button next to the desired multiplier. See also:

Amp/HV/ADC

#IDH_SETTINGSCOARSEGAIN $Amplifier Coarse Gain KAmplifier Coarse Gain

Page 25: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KAmplifier Fine Gain

Amplifier fine gain may be directly entered as a multiplier value between 1.0 and 2.55. See also:

Amp/HV/ADC

#IDH_SETTINGSFINEGAIN $Amplifier Fine Gain KAmplifier Fine Gain

Page 26: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KADC Conversion Gain

Conversion Gain represents the number of channels that will be sampled and displayed on the screen. Smaller values save as smaller files The conversion gain default setting is 1024 channels. This is preferred for most scintillation detector applications and generally no adjustment is required. For certain applications, such as alpha spectroscopy, it may be necessary to change this parameter to either 256, 512, or 2048 channels. See also:

Amp/HV/ADC

#IDH_SETTINGSADCCONVERSIONGAIN $ADC Conversion Gain KADC Conversion Gain

Page 27: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KLower and Upper Level Discriminators

LLD and ULD, Lower Level Discriminator, and Upper Level Discriminator, allow the user to set a value between 0 and 106 (roughly percent) that cuts off signal before it gets to the ADC. The LLD is often used to block high-count signals in the low range that are not of interest, but require excessive time to sample. The ULD may be set up to 106. Low level discrimination (LLD) may be scrolled or directly entered. Upper level discrimination (ULD) may be scrolled or directly entered.

An alternative method to change the LLD and ULD is to use the mouse to move the triangles under the X axis. Move the mouse over the triangle to be moved, press the left button, drag the triangle and release it where desired. The software will not allow the LLD and the ULD set outside appropriate ranges. See also:

Amp/HV/ADC

#IDH_STARTUPLLDULD $Lower and Upper Level Discriminators KLower and Upper Level Discriminators

Page 28: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KPresets Preset Time The real time count and the live time count may be changed using the Preset function. Preset Integral The instrument can be set to stop automatically after a ROI integral.

Click the Preset Time Button on the toolbar:

Click the Preset Integral Button on the toolbar:

Or use the settings menu and click on Presets For details see:

Preset Time Preset Integral

# IDH_PRESETS $Presets KPresets

Page 29: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KPreset Time

Preset Live Time provides automatic correction for counting losses caused by the system deadtime. Events which occur during the pulse processing cycle are lost to the system so the timer is automatically updated to compensate for these losses. When operating at excessively high count-rates the deadtime meter will indicate a high value and the real counting time may be more than doubled. Increasing the LLD setting can help reduce some high deadtime effects. Preset Real Time sets the counting timer to run for actual clocktime and makes no correction for losses due to deadtime effects. Click on Settings, click on Presets Enter the LIVE or REAL time in the correct box. Click on OK, to set adjustment and exit menu.

Both the LIVE TIME and REAL TIME values are displayed on the UCS20 status bar as LT and RT. These values are saved in the file during data storage.

#IDH_OPPRESETTIME $Preset Time KPreset Time

Page 30: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KPreset Integral

Set Integral To set an integral count it is necessary to first establish a ROI and then position the marker within the region. Selecting an ROI and setting a value other than 0 in preset integral will cause the system to STOP counting when the total of all the channels within the ROI reaches that value.

#IDH_OPPRESETINTEGRAL $Preset Integral KPreset Integral

Page 31: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KGo, Stop and Erase

Go, Stop and Erase functions are accessed with the Tool Bar buttons. Clicking on Start begins data collection. Clicking on Stop ends data collection. Clicking on Erase sets each channel’s data to zero.

#IDH_OPSTARTETC $Go, Stop, and Erase KGo, Stop, and Erase

Page 32: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KRegion of Interest (ROI)

Region of interest (ROI) selection is an advanced feature which provides instantaneous computation of peak gross and net counts. These values may be used along with isotope decay tables and detection efficiency to calculate absolute or relative isotopic activities. ROI’s must not overlap and need to be separated by at least one channel for correct area calculation. Up to 16 different ROI’s are possible using the color selector from the pull down Settings menu.

Set ROI To set an ROI around a peak, click the ROI button on the Tool Bar. Click the left mouse button at the beginning of the ROI, hold down the left mouse button and drag the marker to the other side of the peak, release mouse button. Clear ROI Move marker to the ROI to be cleared. Open the Setting Menu, open ROI and select Clear ROI. Gross and Net Count When the marker is positioned in a region of interest (ROI), the UCS20 software automatically calculates the Gross and Net area of the region. In order to minimize statistical effects at the ROI endpoints, a 3-point averaging technique is applied. The contents of channels (n-1), (n), and (n+1) are summed and averaged to derive the content of the endpoint channel for the net area computation. A linear interpolation is performed between these averaged endpoint values and counts below this interpolation are #IDH_OPROI $Region Of Interest KRegion Of Interest

Page 33: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

subtracted to arrive at the Net area of the peak. Gross counts is the sum of all channels in the ROI. Position the marker in the peak of interest. The Gross and Net areas are automatically computed and displayed on the spectrum screen.

Preset Integral

Page 34: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFunctions

Energy Calibration Isotope Matching Strip Spectrum Smoothing

#IDH_FUNCTIONS $Functions KFunctions

Page 35: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KEnergy Calibration

The energy calibration feature allows the marker to read directly in energy units. Two calibration functions are possible, a 2-point linear, or a 3-point quadratic fit. In order to perform an energy calibration, it is first necessary to acquire a spectrum using known isotopes. Cs-137 together with Co-60 works well for many applications, producing gamma lines at 32 keV, 662 keV, 1173 keV and 1332 keV. Select 2-point or 3-point mode and enter the calibration units to be used, (keV or MeV). Position the marker at the highest channel of the first peak and enter the peak energy value. Move the marker to the high point on the second peak to be used for the calibration, enter energy number. If a 3-point calibration is required, continue by moving the marker to the peak channel of the third peak, enter its energy and click OK. The system will now be calibrated and the marker position will read directly in energy. To return to the channel number mode, click on Settings, click on Uncalibrate. Energy Calibration may also be selected using the right mouse button.

#IDH_FUNCENERCAL $Energy Calibration KEnergy Calibration

Page 36: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KIsotope Matching

Displaying Isotope Peaks Isotope peaks may be indicated on calibrated spectra. These peaks are selected from a list provided by selecting the Display menu and clicking on Iso Match. The following dialog box will be displayed:

#IDH_FUNCISOMATCH $Isotope Matching KIsotope Matching

Page 37: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

Click the isotopes peaks in the left window that you want to display. These will be transferred to the right window. When your list is complete, click Okay to display them. Editing the Iso Match list Select the Edit menu and click Iso Match. The following dialog box will be displayed:

IsoMatch Library NOT loaded. IsoMatch Library IS loaded The dialog box top window labeled ‘Select an existing isotope’ will be empty unless an Iso Match library has been loaded. If a library has been loaded, you can select on of the entries from the window, if a library has not been loaded, or you want to add an entry to

Page 38: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

the list, enter the name in the second window titled ‘or enter and isotope name’. Enter the number of peaks you want to add for this isotope in the third box labeled ‘Enter number of peaks [10 max]’ and click on Edit. Further dialog boxes will appear that allow you to enter peak(s) for the isotope.

If you want to save the Iso Match to a disk file, open the File Menu and click on Save Library.

Page 39: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background

The Strip Background option is available only in the File Mode. The user may load two files (Spectrum and Background) and subtract the second file from the first. The portion subtracted is based on a time adjustment to the data in the second file. For example if the first file was measured with 100 seconds live time and the second file was measured with 200 seconds live time, then the data in the second file is divided by 2 (200 seconds / 100 seconds) before it is subtracted.

Load Spectrum Load Background Show Spectrum Show Background Overlay Spectra Strip Background from Spectrum

Background Subtraction This is a special case of spectrum stripping. Collect a background sample spectrum, usually for a long collection time. Load this spectrum as Background and click on ‘Strip Background from Spectrum.’ The live time fraction of the background is subtracted from spectrum. This provides a convenient method of removing naturally occurring background from a sample spectrum and can be very useful when working with low level environmental samples.

#IDH_STRIP $Strip Background KStrip Background

Page 40: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KLoad Spectrum

Click on Load Spectrum and in the File Dialog Box that opens, select the spectrum you intend to have the background stripped from. For example, the spectrum may be taken for an isotope, the background may be the readings with no isotope present.

#IDH_LOADSPECTRUM1 $Load Spectrum KLoad Spectrum

Page 41: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KLoad Background

Click on Load background and in the File Dialog Box that opens, select the background you intend to strip from the first. For example, the spectrum may be taken for an isotope, the background may be readings with no isotope present.

#IDH_LOADSPECTRUM2 $Load Background KLoad Background

Page 42: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KShow Spectrum

Click Show Spectrum to view spectrum.

#IDH_SHOWSPECTRUM1 $Show Spectrum KShow Spectrum

Page 43: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KShow Background

Click Show Background to view background.

#IDH_SHOWSPECTRUM2 $Show Background KShow Background

Page 44: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KOverlay Spectra

Click Overlay Spectra to view the spectrum and the background at the same time.

#IDH_OVERLAYSPECTRA $Overlay Spectra KOverlay Spectra

Page 45: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background from Spectrum

Click Strip Background from Spectrum to subtract the two spectra, where the background is corrected for the difference in the data collection time to give a correct proportion.

#IDH_STRIPSPECTRUM2FROM1 $Strip Background from Spectrum KStrip Background from Spectrum

Page 46: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KData Smoothing

Click Smooth Data to perform a 3-point averaging of the data currently being displayed. The function uses the following algorithm to average data in each channel, where ‘n’ is the channel number.

(n-1)+(n)+(n+1) . 3

#IDH_FUNCSMOOTH $Data Smoothing KData Smoothing

Page 47: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KMenu Bar Many advanced functions are possible via the pulldown menus. This section describes each operation in the sequence they appear. Black letters indicate the function is operational, gray indicates not-operational, highlighted indicates the function the be be activated.

For details:

File Edit Mode Display Settings Strip View Help

#IDH_MENU $Menu Bar KMenu Bar

Page 48: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile

For details:

File Open File Save File Load Setup File Save Setup File Load Library File Save Library File Print File Print Preview File Print Setup File Exit

#IDH_MENUFILE $File Menu KFile Menu

Page 49: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Open File Open allows the user to open data files. A new instance of the UCS20 application in the File Mode is generated. See Also:

Window Live Mode Window File Mode

#IDH_MENUFILEOPEN $File Open KFile Open

Page 50: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Save The spectrum data and the associated setup and experiment data are saved to a *.spu file.

#IDH_MENUFILESAVE $File Save KFile Save

Page 51: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Load Setup Once the UCS20 has been setup and calibrated, all operating parameters may be stored (Save Setup) as a disk file for subsequent retrieval. If power has been turn off, it is a simple and convenient process to reload the setup file and quickly restore (Load Setup) the analyzer to its previous operating condition.

High Voltage must be turned on after loading setup !

#IDH_MENUFILELOADSETUP $File Load Setup KFile Load Setup

Page 52: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Save Setup Once the UCS20 has been setup and calibrated, all operating parameters may be stored (Save Setup) as a disk file for subsequent retrieval. If power has been turn off, it is a simple and convenient process to reload the setup file and quickly restore (Load Setup) the analyzer to its previous operating condition.

#IDH_MENUFILESAVESETUP $File Save Setup KFile Save Setup

Page 53: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Load Library Allows loading of an Iso Match library file (*.itm). See also:

Isotope Matching

#IDH_MENUFILELOADLIBRARY $File Load Library KFile Load Library

Page 54: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Save Library Allows saving of an Iso Match library file (*.itm). See also:

Isotope Matching

#IDH_MENUFILESAVELIBRARY $File Save Library KFile Save Library

Page 55: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Print Allows the user to print the displayed spectrum.

#IDH_MENUFILEPRINT $File Print KFile Print

Page 56: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Print Preview Allows the user to preview the spectrum as it will be printed.

#IDH_MENUFILEPRINTPREVIEW $File Print Preview KFile Print Preview

Page 57: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Print Setup Allows the user to adjust the printer parameters before printing.

#IDH_MENUFILEPRINTSETUP $File Print Setup KFile Print Setup

Page 58: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KFile Exit Closes the application.

#IDH_MENUFILEEXIT $File Exit KFile Exit

Page 59: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KEdit

For details see:

Edit Experiment Edit Iso Match Edit Smooth Data

#IDH_MENUEDIT $Edit Menu KEdit Menu

Page 60: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KEdit Experiment

Edit Experiment provides a means of inserting text into spectral file headers for referencing specific measurements. This text is saved along with data and parameter information in .SPE and .TSV files, and it is used for the Peak Report and the Data Report. Enter the desired text into the dialog box and click Okay when finished.

#IDH_EDITEXPERIMENT $Edit Experiment KEdit Experiment

Page 61: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KEdit Iso Match Edit Iso Match allows the user to edit isotope data, add and delete isotopes from library. See also:

Isotope Matching

#IDH_EDITISOMATCH $Edit Iso Match KEdit Iso Match

Page 62: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KEdit Smooth Data Edit Smooth Data allows the user to apply a three-point smoothing algorithm to the displaed data. For details see:

Data Smoothing

#IDH_EDITSMOOTHDATA $Edit Smooth Data KEdit Smooth Data

Page 63: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KMode

For details see:

Mode Pulse Height Mode Multi Channel Scaling Mode External MCS

#IDH_MENUMODE $Mode KMode

Page 64: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KMode Pulse Height

Click on Pulse Height to select the Pulse Height Mode. See:

Pulse Height Analysis

#IDH_MENUMODEPULSEHEIGHT $Mode Pulse Height KMode Pulse Height

Page 65: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KMode Multi Channel Scaling

Click on Multi Channel Scaling to select the Multi Channel Scaling Mode. See:

Multi Channel Scaling

#IDH_MENUMODEMCS $Mode Multi Channel Scaling KMode Multi Channel Scaling

Page 66: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KMode External Multi Channel Scaling

Click on External MCS to select the External Multi Channel Scaling Mode. See:

External Multi Channel Scaling

#IDH_MENUMODEEXTMCS $Mode External Multi Channel Scaling KMode External Multi Channel Scaling

Page 67: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KDisplay

For details see:

Display Peak Report Display Data Report Display Calibration Display ROIs Display Iso Match Display Pixel Size

#IDH_MENUDISPLAY $Display KDisplay

Page 68: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KDisplay Peak Report If regions of interest have been set around peaks in a spectrum, the Peak Report provides a convenient method of displaying peak information in tabular form. Readout will be in energy units if the energy calibration is active.

#IDH_MENUDISPLAYPEAKREPORT $Display Peak Report KDisplay Peak Report

Page 69: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KDisplay Data Report The Data Report includes all hardware setting, counting parameters and spectrum data. ROI data is reported by lower and upper channels set, gross, net, FWHM, centroid, all channels and corresponding counts.

#IDH_MENUDISPLAYDATAREPORT $Display Data Report KDisplay Data Report

Page 70: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KDisplay Calibration Display Calibration allows the user to switch between on/off in calibration mode and channel numbers or energy is displayed on the horizontal line.

#IDH_MENUDISPLAYCALIBRATION $ Display Calibration K Display Calibration

Page 71: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KDisplay ROIs Display ROIs lets the user toggle between displaying and not displaying the ROIs.

#IDH_MENUDISPLAYROIS $Display ROIs KDisplay ROIs

Page 72: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KDisplay Iso Match Display Iso Match lets the user toggle between displaying and not displaying the Iso Match peaks.

#IDH_MENUDISPLAYISOMATCH $Display Iso Match KDisplay Iso Match

Page 73: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KDisplay Pixel Sizes

Allows the user to choose between 1, 2, and 3 pixels per data point displayed. The default is 2.

#IDH_DISPLAYPIXELSIZES $Display Pixel Sizes KDisplay Pixel Sizes

Page 74: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings

In Preset mode In MCS mode

ROIs Clear ROI Set ROI

Presets Preset Time Preset Integral

Amp/HV/ADC

High Voltage Amplifier Coarse Gain Amplifier Fine Gain ADC Conversion Gain lower and Upper Level Discriminators

#IDH_MENUSETTINGS $Settings Menu KSettings Menu

Page 75: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings ROIs

Allows the user to select the option to set or clear an ROI. See:

Clear ROI Set ROI

#IDH_MENUSETTINGSROIS $Settings ROIs KSettings ROIs

Page 76: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KClear ROI

Clicking on Clear ROI will clear the ROI indicated by the marker.

#IDH_MENUSETTINGSROICLEARROI $Clear ROI KClear ROI

Page 77: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSet ROI

Clicking on Set ROI allows the user to set the ROI. See also:

Region of Interest (ROI)

#IDH_MENUSETTINGSROISETROI $Set ROI KSet ROI

Page 78: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings Energy Calibrate

Opens a submenu for calibrating and uncalibrating the spectrum. See:

Settings Energy Uncalibration Settings Energy Calibrate 2 Point Settings Energy Calibrate 3 Point

#IDH_MENUSETTINGSENERGYCALIBRATE $Settings Energy Calibrate KSettings Energy Calibrate

Page 79: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$#Settings Energy Uncalibrate Clicking Energy Uncalibrate will undo energy calibration and return the spectrum to the channel mode of data display. See:

Energy Calibration

#IDH_MENUSETTINGSENERGYUNCALIBRATE $Settings Energy Uncalibrate #Settings Energy Uncalibrate

Page 80: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings Energy Calibrate 2 Point Clicking 2-Point allows the user to calibrate the date using two points. See:

Energy Calibration

#IDH_MENUSETTINGSENERGY2POINT $Settings Energy Calibrate 2 Point KSettings Energy Calibrate 2 Point

Page 81: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings Energy Calibrate 3 Point Clicking 3-Point allows the user to calibrate the date using three points. See:

Energy Calibration

#IDH_MENUSETTINGSENERGY3POINT $Settings Energy Calibrate 3 Point KSettings Energy Calibrate 3 Point

Page 82: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings Preset Clicking Presets allows the user to select the Presets Dialog box. See:

Preset Time Preset Integral

#IDH_MENUSETTINGSPRESET $Settings Preset KSettings Preset

Page 83: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings Amp/HV/ADC Clicking Amp/HV/ADC allows the user to select the Amp/HV/ADC Dialog box. See:

Amp/HV/ADC High Voltage Amplifier Coarse Gain Amplifier Fine Gain ADC Conversion Gain lower and Upper Level Discriminators

#IDH_MENUSETTINGSAMP/HV/ADC $Settings Amp/HV/ADC KSettings Amp/HV/ADC

Page 84: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings MCS Clicking MCS allows the user to access the MCS Dwell Time dialog box, if the Mode is set to MCS.

Scroll to the desired Dwell Time then highlight the value selected then press OK. See:

Multi Channel Scaling

#IDH_MENUSETTINGSMCS $Settings MCS KSettings MCS

Page 85: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSettings Color Clicking Color allows the user to select the Colors Dialog Box to set or change the colors for the ROIs, Background, .

The Color Dialog Box allows the user to select custom colors for ROIs, Plot Background, Plot Border and Text. Select the item to change, click on Change, select the desire color, click on OK, returns to the Color screen, make additional color changes, when all color changes have been made, click on OK, enters data and returns to spectrum screen. Color allows the user to select a range of Basic Colors or create Custom Colors.

#IDH_MENUSETTINGSCOLOR $Settings Color KSettings Color

Page 86: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

Dialog Box with standard Colors.

Dialog Box expanded for custom colors. Note: Setup of computer graphic may affect the true color of the color selected.

Page 87: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background

Allows the user to load a spectrum and a background and then strip the background from the spectrum. See:

Strip Background

#IDH_MENUSTRIP $Strip Background KStrip Background

Page 88: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background - Load Spectrum See:

Load Spectrum

#IDH_STRIPLOADSPECTRUM1 $Strip Background – Load Spectrum KStrip Background – Load Spectrum

Page 89: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background - Load Background See:

Load Background

#IDH_STRIPLOADSPECTRUM2 $Strip Background – Load Background KStrip Background – Load Background

Page 90: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background - Show Spectrum See:

Show Spectrum

#IDH_STRIPSHOWSPECTRUM1 $Strip Background – Show Spectrum KStrip Background – Show Spectrum

Page 91: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background - Show Background See:

Show Background

#IDH_STRIPSHOWSPECTRUM2 $Strip Background – Show Background KStrip Background – Show Background

Page 92: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background – Overlay Spectra See:

Overlay Spectra

#IDH_STRIPOVERLAYSPECTRA $Strip Background – Overlay Spectra KStrip Background – Overlay Spectra

Page 93: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStrip Background – Strip Background from Spectrum See:

Strip Background from Spectrum

#IDH_ASTRIPSPECTRUM2FROM1 $Strip Background – Strip Background from Spectrum KStrip Background – Strip Background from Spectrum

Page 94: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KView

Allows the user to display or not display the Tool Bar and/or the Status Bar.

Tool Bar Status Bar

#IDH_MENUVIEW $View KView

Page 95: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KTool Bar Allows the user to display or not display the Tool Bar.

#IDH_MENUVIEWTOOLBAR $Tool Bar KTool Bar

Page 96: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStatus Bar Allows the user to display or not display the Status Bar.

#IDH_MENUVIEWSTATUSBAR $Status Bar KStatus Bar

Page 97: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KHelp

The Help menu provides a convenient operator reference for the UCS20 in the standard Windows Help format.

#IDH_MENUHELP $Help Menu KHelp Menu

Page 98: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KContents The Help menu provides a convenient operator reference for the UCS20 in the standard Windows Help format.

#IDH_MENUHELPCONTENTS $Contents KContents

Page 99: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KUsing Help The Using Help item provides the standard Windows Help on using the Windows Help system.

#IDH_MENUHELPUSINGHELP $Using Help KUsing Help

Page 100: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KAbout Displays a splash screen with the Application name and version number.

#IDH_MENUHELPABOUT $About KAbout

Page 101: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KTool Bar

Go Stop Erase Show Peak Report Show Data Report Amp/HV/ADC Presets ROI Spectrum Window Sizing Y axis Increase Y axis Decrease Y axis Log X axis expand X axis contract X axis right 256 channels X axis right 16 channels X axis left 16 channels X axis left 256 channels

#IDH_TOOLBAR $Toolbar KToolbar

Page 102: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KGo

Go allows the user to start the acquire mode of a spectrum. This can also be accomplished by clicking on the green start icon on the display screen. See:

Go, Stop and Erase

#IDH_TBGO $Go Button K Go Button

Page 103: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KStop

Stop allows the user to stop the acquire mode of a spectrum. This can also be accomplished by clicking on the red stop icon on the display. See:

Go, Stop and Erase

#IDH_TBSTOP $Stop Button K Stop Button

Page 104: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KErase

Erase allows the user to erase the spectrum when in stop mode. This can also be accomplished by clicking on the Eraser Icon on the display screen. See:

Go, Stop and Erase

#IDH_TBERASE $Erase Button KErase Button

Page 105: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KShow Peak Report

If regions of interest have been set around peaks in a spectrum, the Peak Report provides a convenient method of displaying peak information in tabular form. Readout will be in energy units if the energy calibration is active.

#IDH_TBSHOWPEAK $Show Peak Button KShow Peak Button

Page 106: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KShow Data Report

Data Report includes all hardware setting, counting parameters and spectrum data. ROI data is reported by lower and upper channels set, gross, net, FWHM, centroid, all channels and corresponding counts.

#IDH_TBSHOWDATA $Show Data Button KShow Data Button

Page 107: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KAmp/HV/ADC

Allows the user to select the Amp/HV/ADC Dialog box. See:

Amp/HV/ADC High Voltage Amplifier Coarse Gain Amplifier Fine Gain ADC Conversion Gain lower and Upper Level Discriminators

#IDH_TBAMPHVADC $AMP/HV/ADC Button KAMP/HV/ADC Button

Page 108: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KPresets

Allows the user to select the Presets Dialog box. See:

Preset Time Preset Integral

#IDH_TBPRESETS $Presets Button KPresets Button

Page 109: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KROI

Allows the user to set an ROI. See:

Region Of Interest

#IDH_TBROI $Region Of Interest Button K Region Of Interest Button

Page 110: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSpectrum Window Sizing

These buttons allow the user to set the size of the X and Y axes. If a button is grayed, its function is not available for use.

#IDH_SPECTRUMWINDOW $Spectrum Window KSpectrum Window

Page 111: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KY axis Increase

Clicking the Y axis increase button doubles the magnitude of the Y axis.

#IDH_TBYINC $Y axis increase Button K Y axis increase Button

Page 112: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KY axis Decrease

Clicking the Y axis decrease button halves the magnitude of the Y axis.

#IDH_TBYDEC $Y axis decrease Button KY axis decrease Button

Page 113: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KY axis Log

Clicking the Y axis Log button sets the Y axis to a logarithmic scale with a maximum of 16 meg.

#IDH_TBYLOG $Y axis Log Button KY axis Log Button

Page 114: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KX axis expand

Clicking the X axis expand button increases the span of the X axis, up to the maximum set by the Conversion Gain.

#IDH_TBXEXP $X axis expands Button KX axis expands Button

Page 115: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KX axis contract

Clicking the X axis contract button decreases the span of the X axis.

#IDH_TBXCONT $X axis contract Button KX axis contract Button

Page 116: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KX axis right 256 channels

Active if there are 256 channels to the right of the displayed X axis span. Clicking this button will shift The X axis span 256 channels to the right.

#IDH_TBXR256 $X axis right 256 channels Button KX axis right 256 channels Button

Page 117: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KX axis right 16 channels

Active if there are 16 channels to the right of the displayed X axis span. Clicking this button will shift The X axis span 16 channels to the right.

#IDH_TBXR16 $X axis right 16 channels Button KX axis right 16 channels Button

Page 118: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KX axis left 16 channels

Active if there are 16 channels to the left of the displayed X axis span. Clicking this button will shift The X axis span 16 channels to the left.

#IDH_TBXL16 $X axis left 16 channels Button KX axis left 16 channels Button

Page 119: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KX axis left 256 channels

Active if there are 256 channels to the left of the displayed X axis span. Clicking this button will shift The X axis span 256 channels to the left.

#IDH_TBXL256 $X axis left 256 Button KUSC20 Topics

Page 120: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

####$KStatus Bar

The status bar at the bottom of the window displays a context sensitive help message on the left side, the high voltage, live time, real time, and selected device on the right side.

#IDH_STATUSBAR #IDH_SBHV #IDH_SBLT #IDH_SBRT $Status Bar Button KStatus Bar Button

Page 121: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSpecifications

Hardware Software

#IDH_SPECIFICATIONS $Specifications KSpecifications

Page 122: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KHardware Physical: Single instrument includes preamplifier, amplifier, detector high voltage, 2048-channel multichannel analyzer with data memory, LLD and ULD. Fully compatible with many scintillation detectors and commercial tube bases. Amplifier: On-board combination preamplifier/amplifier for use with scintillation detectors and PMT's. Computer controlled coarse and fine gain from (x) 1 to (x) 160. ADC: Wilkinson type with 80 MHz clock and computer selected convrsion gain of 2048,1024. 512, or 256 channels. Direct input accepts pulse peaking times of 1 µsec. to 10 µsec. Includes dead-time correction when used in Live-time mode. LLD & ULD: Independently computer controlled in 4-channel increments over entire input range. Operates prior to ADC for reduced system dead time. Modes: MCA for pulse height analysis, or MCS for half-life decay or other time related studies. Timers: Real-time or Live-time operation selectable in 1-second increments for PHA, or dwell times from 10 msec. to 600 seconds per channel in MCS mode. Data Memory: On-board static RAM, 2048 channel (x) 3 Bytes for data, plus region-of-interest flag. Deadtime: System dead-time is computed and displayed on screen during acquisition. Power: AC line powered with an auto sensing power supply for 100 – 250 VAC, 10 watts total. Connections On Rear Panel:

Connections On Rear Panel

#IDH_SPECHW $Hardware Button KHardware Button

Page 123: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSoftware System: Operates under Microsoft Windows® 98, Windows® 2000, Windows® XP with 600 kb for the executable and 5 meg for the optional help file available disk space, 32 meg RAM (48 recommended), and compatible mouse. Display: VGA or SVGA color graphics (800x600 recommended. Vertical scale adjusts from 32 to 16M and LOG display. Horizontal 2048 channels with reduction down to 256 channels. Time Mode: Preset live-time or preset real-time selection. Both times are recorded and displayed. ROI'S: Multiple Regions-of Interest using color coding. Integral: When cursor is in ROI, computes gross area, net area with end point averaging, centroid and FWHM. Energy Cal: 2-point linear or 3-point quadratic converts cursor position reading directly to energy units. (Time units in MCS mode.) Strip: Subtracts channel-by-channel time normalized data stored in File Mode. Overlays two saved spectra in File Mode Smooth: 3-point smoothing of selected displayed data. Control: Software control of High Voltage, Amplifier Gain, Lower and Upper level discriminators, and ADC Con- version Gain. File: Save or load data file and header information in binary, or spreadsheet compatible formats. Print: Prints current screen display to Windows printer. ROI File: Saves ROI data, centroid, FWHM, gross and net integrals, and header information in spreadsheet compatible format. ISOMATCH: Isotope library text file with peak markers and labeling for overlaying on spectrum for quick isotope identification. Library may be edited from Edit, IsoMatch pull down menu.

#IDH_SPECSW $Software Button KSoftware Button

Page 124: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

#$KSpectrum Techniques Contact

SPECTRUM TECHNIQUES, INC. 106 Union Valley Road Oak Ridge, TN 37830

USA Tel. (865) 482-9937 Fax. (865) 483-0473 e-mail: [email protected]

Web Site: http://www.spectrumtechniques.com

#IDH_SPECTECHCONTACT $Spectrum Techniques Contact KSpectrum Techniques Contact

Page 125: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

GN

D2G

ND

1

G5100 REV1 C 2000SPECTRUM TECHNIQUES INC.UCS-20

ABC

Page 126: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

WPC1

WPB

1

WPA1

SN74F32N

U21:D12

1311

WP21

WP3

1

U2

5565AL-10I/O8

19I/O7

18I/O6

17I/O5

16I/O4

15I/O3

13I/O2

12I/O1

11

A122

A1123

A1021

A924

A825

A73

A64

A55

A46

A37

A28

A19

A010

OE22

R/W27

CE226 CE120

U26

74LS374

4D8

8Q19

7Q16

6Q15

5Q12

4Q9

3Q6

1Q2

8D18

7D17

6D14

5D13

3D7

2D4

1D3

CLK11 OC

1

2Q5

U23

74LS3748Q

197Q

166Q

155Q

124Q

93Q

62Q

51Q

2

8D18

7D17

6D14

5D13

4D8

3D7

2D4

1D3

CLK11 OC

1

390PFC8

U17

SN74LS373N

1Q2

2Q5

3Q6

4Q9

5Q12

6Q15

7Q16

8Q19

8D18

7D17

6D14

5D13

4D8

3D7

2D4

1D3

C11 OC

1

82C55AN

U6

PB728

PB222

PB020

PB121

CS7

RESET39

RD6

WR40

A19

A010

D038

D137

D236

D335

D433

D532

D631

D730

PA05

PA14

PA23

PA32

PA444

PA543

PA642

PA741

PC016

PC117

PC218

PC319

PC415

PC514

PC613

PC711

PB324

PB425

PB526

PB627

U3

PA7140JI12

43I11

42I4

19I/O12

18

I/O49

I/O38

I/O27

I/O16

CLK12

CLK224

I927

I725

I826

I13

I24

I/O1328

I/O1429

I/O1530

I/O1631

I/O1732

I/O1833

I35

I/O510

I/O611

I/O1934

I/O2035

I/O2136

I/O2338

I/O2440

I1041

I/O914

I/O1015

I/O1116

I520

I621

I/O712

I/O813

I/O2237

SN74F32N

U21:B

4

56

SN74F08N

U15:D

12

1311

SN74F08N

U15:C

9

108

GND

2K

R24

LED2

+5V

R20

10K10uF

C7

+5V

U14

74LS3748Q

197Q

166Q

155Q

124Q

93Q

62Q

51Q

2

8D18

7D17

6D14

5D13

4D8

3D7

2D4

1D3

CLK11 OC

1

TP3

TP2

1K

R19

1K

R18

1K

R17

GND

TP1

U20

80C188

DEN39

DT/ R40

CLKOUT56

PCS6 / A232PCS5 / A131

PCS329PCS228PCS127

UCS34MCS335MCS236MCS137

INT3 / INTA141 INT2 / INTA042

A19/S665

A18/S566

A17/S467

A16/S368

X258

TEST47

RFSH64

LOCK48

HLDA51

TMROUT123

TMROUT022

ALE/QS061

AD72

AD64

AD56

AD48

AD311

AD213

AD115

AD017

S254S153S052WR/ QS163

RD/ QSMD62

RESET57

PCS430

PCS025LCS33

MCS038

ARDY55

HOLD50 RES24

DRQ119

DRQ018

INT144

INT045

NMI46

X159

A143

A135

A127

A1110

A1012

A914

A816

SRDY49

TMRIN121

A151

TMRIN020

+5V

IN914

D1

100

R21

U24

EP610C-25XJ

I/O36

I317

I/O1626

I/O1525

I/O1424

I/O1323

I/O1222

I/O1121

I/O1020

I/O918

I/O812

I/O710

I/O69

I/O58

I/O47

I/O25

GND14

GND15

CLK12

CLK216

I13

I/O14

I427

I213

+5VF28

+5VF1

GND

U25

EP910C-30XJ

I/O510

I/O611

I/O2136

I/O2035

I/O1934

I/O1833

I/O1732

I/O1631

I/O1530

I1041

I1142

I1243

I/O2440

I/O2338

I/O2237

I/O1429

I/O1328

I826

I725

I621

I520

I419

I/O1218

I/O1116

I/O1015

I/O914

I/O813

I/O712

I/O49

I/O38

I/O27

I/O16

I35

I24

I13

CLK224

CLK12

I927

27K

R23

U16

74193

QC6

QB2

QA3

BO13

CO12

DOWN4

QD7

D9

C10

B1

A15

UP5 LOAD

11CLR

14

+5V

TP6.01

C9TP5

TP4

GND

WP111

WP121

GND

IN914

D2

U22:B

74LS244Y4

3Y3

5Y2

7Y1

9

A417

A315

A213

A111

G19

U22:A

74LS244Y4

12Y3

14Y2

16Y1

18

A48

A36

A24

A12

G1

U19:A

SN74LS08N

32

1

U19:B

SN74LS08N

65

4

U19:C

SN74LS08N

810

9

TMM27256A-20D

U5

VPP1

CE20

OE22

A010

A19

A28

A37

A46

A55

A64

A73

A825

A924

A1021

A1123

A122

A1326

A1427

O011

O112

O213

O315

O416

O517

O618

O719

WP41

WP51

WP71

U10

PA7140J

I/O2338

I1041

I1142

I1243

I/O1116

I/O1015

I/O914

I/O813

I/O712

I/O611

I/O510

I/O49

I/O38

I/O27

I/O16

CLK12

CLK224

I927

I725

I826

I13

I24

I/O1328

I/O1429

I/O1530

I/O1631

I/O1732

I/O1833

I35

I/O1934

I/O2035

I/O2136

I/O2237

I/O2440

I/O1218

I419

I520

I621

GND

GND

.1C4

10

R14

2.49K*

R16

2.49K*

R15

10K

R13CW

W

CCW

.1

C3

TLO74CN

U12:A

1

4

11

3

2

2K

R12

LED1

+5V

R11

10K

CCW

W

CW

.01

C6

.1

C5LM555CNB

U13

VCC8

RESET4

TRIG2

THR6

CONT5

DIS7

GND1

OUT3

1K

R9

WP11

10

R10

K6T1008C2C-

U4

A162

A1531

I/O821

I/O720

I/O619

I/O518

I/O417

I/O315

I/O214

I/O113

A143

A1328

A124

A1125

A1023

A926

A827

A75

A66

A57

A48

A39

A210

A111

A012 CS122 OE24

R/W29

CS230

J3

CONN15PIN

123456789101112131415

J2

CONN9PIN

123456789

USBCONN

J11234

GND

SN74F08N

U15:A1

23

SN74F08N

U15:B4

56

X2

80MHzOSCILLATOR

8

SN74F04N

U18:A

1 2

C1F

47UF

R1F

10

U18:B

SN74F04N

43

U18:C

SN74F04N

65

U18:D

SN74F04N

89

U18:E

SN74F04N

1011

U18:F

SN74F04N

1213U21:A

SN74F32N

32

1U21:C

SN74F32N

810

9

100R22

IN914D20

2K

R172

100

R171WP29

1

WP301

IN914

D21

+5V

GND

237

RLIM1

CA

220PF

GND

3-28-00

1

ROI WIDTH

ROI AMP

’HICLR’

’LOCLR’

’CMCS’

’CEMCS’

AD7D

AD6D

AD5D

AD4D

AD3D

AD2D

AD1D

AD0D

A0

RD*

WR*

PCS4*

PCS3*

G1

G2

G3

G4

G5

G6

G7

G8

31

R.S.S.

TEMP SENS

EXT MCS

ROI OUT

MSB OUT

UCS-20 SYSTEM & CONTROL

UCS-20.S01

(REV1 03-22-01)

GATE IN

ADDED RILM1 6/14/02

SYNC

PCS6*

A16A15

ROI*

+5V

HVLEDCNTHICNTLO

INT0STB0*

ACK0*

AD1

CNTTACQ*EMCSMCS

CNTLOCNTHITEMP

PCS2*

AD0

LA0

BIT10

ENAHI*CVRDY

BIT8BIT9

ENALO*CVRDY

BIT0BIT1BIT2BIT3BIT4BIT5BIT6BIT7

AD7AD6AD5AD4AD3AD2AD1AD0

ALE

A1A2A3A4A5A6A7

A0

GND

GNDGND

PCS0*

RES

RD*WR*

A1A0

AD0AD1AD2AD3AD4AD5AD6AD7

PCLKWR*RD*A0A1

PCS0*OBF0*DRQ0IOCS0*IOCS1*ACK0*STB0*

LA13LRD*LWR*

ACQ*

PCLK

RESET*

G1G2G3G4G5G6G7G8

GND

AD0DAD1DAD2DAD3DAD4DAD5DAD6DAD7D

PCS2*PCS1*

INT1

INT1

INT2

INT3

STAT2

STAT1

STAT0

GND

GND

+5V+5V

+5V

UCS*RD*

A0A1A2A3A4A5A6A7A8A9A10A11A12

INT0

BSY

DRQ0CVRDY

A8A9A10A11A12A13A14

STAT2STAT1STAT0WR*ALERD*

RES

AD0AD1AD2AD3AD4AD5AD6AD7

PCS4*PCS3*

PCS0*

UCS*

CNTT

PCS5*

PCS6*

WR*

ENALO*CBA

SIGIN

GND

RUN

ENAHI*

CLK2

OFPCS1*RD*

SIGOUT

LP

SYNCACQ*

LLD*ULD*PKDPKDL*PKDL

ZLDL

RUN

AD0AD1AD2AD3AD4AD5AD6AD7

AD0AD1AD2AD3AD4AD5AD6AD7

CNTBIT2BIT10BIT5

BIT6BIT3

PKD

CLK1

RDNOFBIT7BIT0BIT8BIT4BIT9

CVRDYGND

MCS

BIT1

CLK2

CLK1

RSET

LP

CNT

DMCSEMCS

SIGOUT B

ASIGIN

ZLD*

BSY

C

AD7DAD6DAD5DAD4D

AD3DAD2DAD1D

AD7AD6AD5AD4

AD3AD2AD1

AD0DAD0

PCS3*

PCS4*

PCS5*

AD7AD6AD5AD4AD3AD2AD1AD0

A13A14

TEMP

+5V

GND

RA0RA1RA2RA3RA4RA5RA6RA7RA8RA9RA10

RAD0

RRD*RWR*

ROICS*

BIT0BIT1BIT2A0A1A2A3A4A5A6A7A8A9A10RA0BIT3BIT4BIT5

BIT6BIT7BIT8RA1RA2RA3RA4RA5RA6RA7RA8RA9RA10CVRDYRRD*BIT9BIT10ACQ*

GNDGND

+12V

HVLED

+5V

ROI*MCS0*RRD*

ROICS*

SYNC

LP

MSB

MSB

-12V

LCS*

+5VWR*RD*LCS*A0A1A2A3A4A5A6A7A8A9A10A11A12A13A14A15A16

AD7AD6AD5AD4AD3AD2AD1AD0

HD0HD1HD2

HD5

HD7HD6

HD4HD3

IOCS0*GND

+3.3V

INT2INT3

IOCS1*

LA0LA13

LRD*

LWR*

RES

USBD+USBD-

OBF0*

IBF0

COMCOM

COMCOM

IBF0

OBF0*

MCS0*

PCS6*

RAD0

+5V +5VF GND

+5V +5V

+5V

+5V

RSET

GATE

GATE

+5V

RWR*

A B C D E F G H

6

5

4

3

2

1

HGFEDCBA

1

2

3

4

5

6

DRevNumber

Title

Size

Date

Filename

Drawn by

ofSheet

Page 127: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

C17 .1

R45

19.6K*

R72

2.15K*

R57

1.1K*

C25

10PF

LED3

R94

2K

+5V

C39

.1

R87

3.3M

Q1

MPSA64

C

E

B

R79

1MD5

1N914

R103

1.00K*

R99

7.5K*

LM385

D10+12V

D11

1N914

R118

2.49K*

WP141

U39

MPQ3904

EA3

CD14

GA1

BA2

NC4

EB5

BB6

CC8

BC9

EC10

NC11

ED12

BD13

CB7

-12V

R120

2.00

K*

51

R129

10

R10

6

100

R77100

R76

10R67

100

R60100

R55

10R51

10

R48

51

R41

10

R37

-12V

MC34085P

U31:CU31:C

MC34085P

8

9

10

MC34085P

U31:A

1

4

11

2

3MC34085P

U31:BU31:B

MC34085P

7

6

5

MC34085P

U31:DU31:D

MC34085P

14

13

12MC34085P

U30:DU30:D

MC34085P

14

13

12MC34085P

U30:CU30:C

MC34085P

8

9

10MC34085P

U30:BU30:B

MC34085P

7

6

5

MC34085P

U30:A

1

4

11

2

3

+5V

+12V

-12V

GND

+12V

+12V

LM306P

U387

-3

+2

4

85

6

1

+12V

-12V

-12V

-12V

LM319N

U32:B7

+9

-10

8

+5V

+5V

+12V+12V

+12V

-12V-12V

-12V

-12V+12V

100K

R56W

CCW CW

1N914

D3

+5V

D12

1N914

Q3

2N3906

CE

B

Q4

2N3906

CE

B

+5V

-12V

+12V

-12V

+12V

+12V+12V

-12V

-12V-12V

R110

10.2K*

-12V +12V

1N914

D8

1N914

D6

LM306P

U357

-3

+2

4

85

6

1

D7

1N914U36

MPQ3904

CC8

BA2

EA3

EB5

BB6

CB7

BC9

EC10

NC11

ED12

BD13

CD14

NC4

GA1

2N3906

Q2B

E

C

U37

SD5000

OA1

GA3

SUB2

GB6

IB5

OB8

OC9

IC11

GD14

OD16

NC7

NC15

NC10

GC12

IA4

ID13

R28

499*

R43

100K*

R38

1.1K*

R33

4.42K*

R42

1.1K*

R35

909*

R25

1.33K*

R26

1.62K*

R27

4.99K*

R39

100K

C18

10UF

C19

10UF

R36

909*

R29

1.33K*

R30

1.62K*

R31

4.99K* R32

237*

R34

750*R40

332*

R65 499*

R71

2.15K*

R64

1.1K*

10

R74

10

R63

R52

5.62K*

R66

1.00K*

R59

1.00K*

.1

C28 R61

274K*

R68

2.00K*

R62

2.00K*

10

R53

R88

1K

R89

1K

R102

1K

R101

7.5K

R113

10K

R90

1.00K*

R105

2.87K*

R107

1.00

K*

R108

4.99

K*

51

R10

9

51

R97

R83

1K

R80

3.83K*

R111

10.0*

R81

6.19K*

R91

2.00K* R92

100

R78

100K

C38

10UF

C42

10UF

R82

100

R119

2.00

K*

R127

3.83K*

R121

7.50K*

R115

1K

R116

1K

R114

2.00K*

R130

499*

51

R125

R117

1.50K*

C27

10UF

R54

237*

C23

10UF

R75

1K

R86

100K

10

R104

10

R93

100

R98100

R96

R95

1K

R112

100K

C10

200PF

C20

1000PF

C11

10PF

C12

15PF

C14

15PF

C16

10PF

C33

470PF

C35

390PF

C31 100PF

C24

.1

C34

.1

C26

47PF

C30

10PF

C43

.1

C40

10PF

C48

.1

C46

.0022

C44

.1

C41

.1

C37

.1

C29

.1

U27

SW201

OB15

OC10

OD7

SC9

SA1

NC12

V+13

IC11

GND5

V-4

IA3

IB14

SD8

ID6

SB16

OA2

U29

SW201

OB15

OC10

OD7

OA2

SC9

SA1

NC12

V+13

IC11

GND5

V-4

IA3

IB14

SD8

ID6

SB16

R44

1.1K*

U32:A

LM319N6

11

12

-5

+4

3

100

R84

U28:A

RFBA3

DGND5

OUTA2

VDD17

AGND1

WR16

CS15

DB014

DB113

DB212

DB311

DB410

DB59

DB68

DB77

DA/ DB6

REFA4

1N914

D9

C45

.1R126

1.5K*

-12V

R128

3.01K*

C47

10UF

R124

6.19

K*

R123

6.19K*

R122750*

U34:D

TLO74CN

14

13

12

U34:B

TLO74CN

7

6

5

U34:C

TLO74CN

8

10

9

U34:A

TLO74CN

1

4

11

3

2

DAC8228

U33:B

GND5

VDD17

DA/ DB6

DB77

DB68

DB59

DB410

DB311

DB212

DB113

DB014 CS15 WR16

VOB19

REFB18

VZ1

U33:A

DAC8228

WR16

CS15

DB014

DB113

DB212

DB311

DB410

DB59

DB68

DB77

DA/ DB6

VDD17

GND5

VOA3

REFA4

VZ1

C21

10UF

C13

10UF

C36

.1

332*

R69-12V

R70

200

CCW

W

CW

750*

R73

1N5231

D4

A

K

WP131

WP151

R46

1.1K*

R47

10K

R49

100K*

C22

1000PFWP16

1

WP171

WP181

R50

2.49K*

R58

3.16K*

R100

51

-12V

C32

1UF

10UFC15

R85

1.00K*

R1

237*

11-14-00

1

32

PREAMP

DIRECT

AMP

ZERO

ACTIVITY

UCS-20 ANALOG CIRCUITS

UCS-20.S02

(REV1 03-22-01)

ECN 01-18-02 R-125 & R-128 SWAP

LAST ECN R99 15K>>>7.5K

DIRIN

SIGCSIGC

SIGB

+5V

SIGA

RDN

PKD

ZLDL

ULD*

LLD*

ZLD*

A0AD7DAD6DAD5DAD4DAD3DAD2DAD1DAD0DPCS4*WR*

A0AD7DAD6DAD5DAD4DAD3DAD2DAD1DAD0DPCS4*WR*

SIGA

PKDL*

PKDL

GND

GNDGND

SIGB

A0AD7DAD6DAD5DAD4DAD3DAD2DAD1DAD0DPCS3*WR*

G7

G8

G5

G6

G3

G4

G1

G2

DIRIN

A B C D E F G H

6

5

4

3

2

1

HGFEDCBA

1

2

3

4

5

6

DRevNumber

Title

Size

Date

Filename

Drawn by

ofSheet

Page 128: Spectrum Techniques UCS-20spectrumtechniques.com/manuals/UCS20manual.pdf · The UCS-20 requires only an available USB port and is designed to work seamlessly with USB-equipped PCs

47UF

CF4

470UF

CF3

DB9M

CNX

123456789

GND

.1

C69

10UF

C68

U43

78LO33

VIN3

GND2

VOUT1

C70

.1

GND

1.8K

R169

C89

.1

C88

.1

C87

.1

C86

.1

C85

.1

C84

.1

C83

.1

C82

.1

C81

.1

C80

.1

C79

.1

C78

.1

C77

.1

GND

LED

LED4

10.0K*

R138

R1500F

D15R1500F

D14

R1500F

D13

R1500F

D16

51

R132

GND

R136

5.1K

R137

5.1K

R1465.1K

R141

10k

2N3904

Q7

35.0K*

R135

10K

R134CW

W

CCW

U40

LM555CHC

OUT3

GND1

CONT5

THR6

TRIG2

RESET4

VCC8

DIS7

C50

10UF

GND

+12V

15.0K*R131

10KR133

CW

W

CCW

.01

C56

.001

C57

GND

DAC7528

U42:B

RFBB19

REFB18

OUTB20

DGND5

VDD17

AGND1

DA/ DB6

DB77

DB68

DB59

DB410

DB311

DB212

DB113

DB014 CS15 WR16

R168

1K

10.0K*

R166100K*

R165

470PF

C63

R164

10

U42:A

DAC7528

RFBA3

DGND5

OUTA2

VDD17

AGND1

WR16

CS15

DB014

DB113

DB212

DB311

DB410

DB59

DB68

DB77

DA/ DB6

REFA4

TLO74CN

U41:C

8

10

9

SWPOWERC1 C2

PLUGACM WP281

WP271

WP261

WP25

1

GND

10UF

C65

GND

10UF

C64

L1

10UF

C72

10UF

C71

GNDGND

10UF

C74

10UF

C75

GNDGND

1

RL1

1

RL2

-12V

TLO74CN

U41:A2

3

11

4

1

10

R152

R159

10

+12V

C61

.1

C62

.1

10UF

C38A

T1P1

P2

S1

S2

Q5

10N12L

GND

R142

10K

C55

.001MTM12P10

Q6G

SD

TLO74CN

U41:D

13

12

14

1M

R148

GND

R147

18K

C58

.0047

D17

IN914

C54

.0047

3.3M

R155

IN914

D19

GND

WP24

1

WP23

1

GND

R140

10.0K*

C59 .0047

R1442.2M*

R163

40.2K

GND

R1582.2M*

R139

2K

1M

R143

U41:B

TLO74CN

7

6

5

GND

470UF

C52

C53

.01

C51

.01

C49

.01

R156

1KCCW

W

CW

5.1K

R151

+12V

R161

3.22K*

C66

.1

C67

10UF

R1452.2M*

R149

2.2M*R150

2.2M*

R153

2.2M*R1542.2M*

R160

2.2M*R162

2.2M*

R157

2.2M*

C60

.01

GND

C76

.1

LM385BZX

D18

R170

1

R167

10.0K*

470PF

C73

U44:A

TLO74CN

2

3

11

4

1

U44:B

TLO74CN

5

6

7

U44:C

TLO74CN

9

10

8

U44:D

TLO74CN

13

12

14

+12V

FROM PIN 2

FROM PIN 6

FROM PIN 1

4

1

6

2,3

-12V

+12V

GND

COARSE ADJUST

FINE ADJUST

MHV CONN.

H.V. OUTO

R.S.S

3 3

1

UCS-20 POWER SUPPLIES

UCS-20.S03

05-05-00 (LAST 02-08-02)

+3.3V

GND

+5V

+5V

+5V

AD5D

A0AD7DAD6D

AD4DAD3DAD2DAD1DAD0DPCS5*WR*

AD5D

A0AD7DAD6D

AD4DAD3DAD2DAD1DAD0DPCS5*WR*

GND

+12V

-12V

+5V

-FV

+FV

GND

+5V

GND

+FV

-FV

GND

A B C D E F

4

3

2

1

FEDCBA

1

2

3

4

CRevNumber

Title

Size

Date

Filename Sheet of

Drawn by